[...]... 9.8) © BSI 07-1999 Licensed copy:RMJM, 07/09/2005, Uncontrolled Copy, © BSI blank BS EN 5266 : Part 5 : 1999 List of references (see clause 2) Normative references BSI publications BRITISH STANDARDS INSTITUTION, London BS 381C : 1996 BS 4066 : BS 4066 : Part 1 : 1980 BS 4066 : Part 2 : 1989 BS 5266 : BS 5266 : Part 1 : 1988 BS 5266 : Part 4 : 1999 BS 5378 : BS 6290 : BS 6290 : Part 4 : 1997 BS 6387... copy:RMJM, 07/09/2005, Uncontrolled Copy, © BSI BS 6425 : BS 6425 : Part 1 : 1990 BS 7622 : BS 7622 : Part 1 : 1993 BS 7622 : Part 2 : 1993 BS 7671 : 1992 PD 2379 : 1994 BS EN 60073 : 1997 BS EN 60285 : 1995 BS EN 60529 : 1992 BS EN 60598 : BS EN 60598-1 : 1997 BS EN 60598-2 : BS EN 60598-2-22 : 1999 BS EN 60622 : 1996 BS EN 60896 : BS EN 60896-1 : 1992 BS EN 61032 : 1998 12 Specification for colours... requirements Luminaires for emergency lighting Sealed nickel-cadmium prismatic rechargeable single cells Stationary lead-acid batteries General requirements and methods of test Vented types Protection of persons and equipment by enclosures Probes for verification © BSI 07-1999 BS EN 5266 : Part 5 : 1999 Informative references BSI publications BRITISH STANDARDS INSTITUTION, London BS 1915 : 1968 Specification... Specification for still projectors BS 4120 : 1968 BS 5550 : BS 5550 : Part 2 : BS 5550 : Part 2 : Section 2.7 BS 5550 : Part 2 : Subsection 2.7.2 : 1982 Methods for the measurement of performance of still projectors Cinematography 16 mm film Projection Specification for the performance of 16 mm sound-film projectors Other publication Licensed copy:RMJM, 07/09/2005, Uncontrolled Copy, © BSI [1] GREAT BRITAIN The... and shall conform to BS EN 60528, BS EN 60622 or BS EN 60896-1 and BS 6290 : Part 4, according to its construction The battery shall be chosen to have a minimum working life of 10 years or the assigned working life of the light source whichever is the shorter The battery shall have the capacity to: a) maintain the lamps operational for the rated duration as given in 6.12 of BS 5266 Part 1 : 1988; b)... and use pictograms contained in, BS 5378 All marking shall be legible, durable, and permanently attached 9 BS 5266 : Part 5 : 1999 9.12 Information to be provided by the manufacturer The manufacturer shall make available the following information in a catalogue or the like: a) such data as may be required to carry out the design calculations given in BS 5266 : Part 1 and BS 7671; b) information to enable... appropriate 9.4.2.2 Single lamp In this arrangement, a single lamp shall provide the full light output required to give the minimum illuminance necessary for the emergency lighting system (see 5.3 of BS 5266 : Part 1 : 1988 and annexes A and B of BS 5266 : Part 4 : 1999) 9.4.2.3 Dual lamp Two lamps shall operate together, their combined light output being twice that required to give the minimum illuminance... Office © BSI 07-1999 Licensed copy:RMJM, 07/09/2005, Uncontrolled Copy, © BSI BS 5266 : Part 5 : 1999 BSI 389 Chiswick High Road London W4 4AL | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BSI Ð British... 7400 BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services Tel: 020 8996 9001 Fax: 020 8996 7001 In response to orders for international standards, it is BSI policy to supply the BSI... used 7 BS 5266 : Part 5 : 1999 9.5 Controlgear Licensed copy:RMJM, 07/09/2005, Uncontrolled Copy, © BSI 9.5.1 General It shall be permissible to place the controlgear (including the battery in the case of a self contained system) in the light source enclosure, unless the heat from the lamp would be detrimental to it in which case it shall be placed in a separate enclosure conforming to 22.15 of BS EN . cable BS 4066 : Part 2 : 1989 Method of test on a single small vertical insulated wire or cable BS 5266 : Emergency lighting BS 5266 : Part 1 : 1988 Code of practice for the emergency lighting. purposes of this Part of BS 5266 the definitions given in BS 5266 : Part 1 : 1988 and BS 5266 : Part 4 : 1999 apply. 4 General NOTE. The components specified in this Part of BS 5266 are suitable for. back cover. Licensed copy:RMJM, 07/09/2005, Uncontrolled Copy, © BSI BSI 07-1999 1 BS 5266 : Part 5 : 1999 1 Scope This Part of BS 5266 specifies requirements for optical fibres, lightguides, connectors,