1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Electrical Power Systems Quality, Second Edition phần 10 pptx

48 452 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 48
Dung lượng 1,03 MB

Nội dung

1. Nameplates of transformers, motors, etc. 2. Instrumentation setups 3. Transducer and probe connections 4. Key waveform displays from instruments 5. Substations, switchgear arrangements, arrester positions, etc. 6. Dimensions of key electrical components such as cable lengths Video cameras are similarly useful when there is moving action or ran- dom events. For example, they may be used to help identify the loca- tions of flashovers. Many industrial facilities will require special permission to take photographs and may place stringent limitations on the distribution of any photographs. 11.3.5 Oscilloscopes An oscilloscope is valuable when performing real-time tests. Looking at the voltage and current waveforms can provide much information about what is happening, even without performing detailed harmonic analysis on the waveforms. One can get the magnitudes of the voltages and currents, look for obvious distortion, and detect any major varia- tions in the signals. There are numerous makes and models of oscilloscopes to choose from. A digital oscilloscope with data storage is valuable because the waveform can be saved and analyzed. Oscilloscopes in this category often also have waveform analysis capability (energy calculation, spec- trum analysis). In addition, the digital oscilloscopes can usually be obtained with communications so that waveform data can be uploaded to a personal computer for additional analysis with a software package. The latest developments in oscilloscopes are hand-held instruments with the capability to display waveforms as well as performing some signal processing. These are quite useful for power quality investiga- tions because they are very portable and can be operated like a volt- ohm meter (VOM), but yield much more information. These are ideal for initial plant surveys. A typical device is shown in Figs. 11.10 and 11.11. This particular instrument also has the capability to analyze harmonics and permits connection with personal computers for further data analysis and inclusion into reports as illustrated. 11.3.6 Disturbance analyzers Disturbance analyzers and disturbance monitors form a category of instruments that have been developed specifically for power quality measurements. They typically can measure a wide variety of system Power Quality Monitoring 475 Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. disturbances from very short duration transient voltages to long-dura- tion outages or undervoltages. Thresholds can be set and the instru- ments left unattended to record disturbances over a period of time. The information is most commonly recorded on a paper tape, but many devices have attachments so that it can be recorded on disk as well. There are basically two categories of these devices: 1. Conventional analyzers that summarize events with specific infor- mation such as overvoltage and undervoltage magnitudes, sags and surge magnitude and duration, transient magnitude and duration, etc. 2. Graphics-based analyzers that save and print the actual waveform along with the descriptive information which would be generated by one of the conventional analyzers It is often difficult to determine the characteristics of a disturbance or a transient from the summary information available from conven- tional disturbance analyzers. For instance, an oscillatory transient cannot be effectively described by a peak and a duration. Therefore, it 476 Chapter Eleven Figure 11.10 A hand-held oscillographic monitoring instrument. (Courtesy of Fluke Corporation.) Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. is almost imperative to have the waveform capture capability of a graphics-based disturbance analyzer for detailed analysis of a power quality problem (Fig. 11.12). However, a simple conventional distur- bance monitor can be valuable for initial checks at a problem location. 11.3.7 Spectrum analyzers and harmonic analyzers Instruments in the disturbance analyzer category have very limited harmonic analysis capabilities. Some of the more powerful analyzers have add-on modules that can be used for computing fast Fourier transform (FFT) calculations to determine the lower-order harmonics. However, any significant harmonic measurement requirements will demand an instrument that is designed for spectral analysis or har- monic analysis. Important capabilities for useful harmonic measure- ments include Power Quality Monitoring 477 Figure 11.11 Demonstrating the use of a hand-held, three- phase power quality monitoring instrument to quickly evaluate voltages at the mains. Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. ■ Capability to measure both voltage and current simultaneously so that harmonic power flow information can be obtained. ■ Capability to measure both magnitude and phase angle of individual harmonic components (also needed for power flow calculations). ■ Synchronization and a sampling rate fast enough to obtain accurate measurement of harmonic components up to at least the 37th har- monic (this requirement is a combination of a high sampling rate and a sampling interval based on the 60-Hz fundamental). ■ Capability to characterize the statistical nature of harmonic distor- tion levels (harmonics levels change with changing load conditions and changing system conditions). There are basically three categories of instruments to consider for harmonic analysis: 1. Simple meters. It may sometimes be necessary to make a quick check of harmonic levels at a problem location. A simple, portable meter for this purpose is ideal. There are now several hand-held instruments of this type on the market. Each instrument has advan- tages and disadvantages in its operation and design. These devices generally use microprocessor-based circuitry to perform the necessary calculations to determine individual harmonics up to the 50th har- monic, as well as the rms, the THD, and the telephone influence factor (TIF). Some of these devices can calculate harmonic powers (magni- tudes and angles) and can upload stored waveforms and calculated data to a personal computer. 2. General-purpose spectrum analyzers. Instruments in this cate- gory are designed to perform spectrum analysis on waveforms for a 478 Chapter Eleven Figure 11.12 Graphics-based analyzer output. Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. wide variety of applications. They are general signal analysis instru- ments. The advantage of these instruments is that they have very pow- erful capabilities for a reasonable price since they are designed for a broader market than just power system applications. The disadvan- tage is that they are not designed specifically for sampling power fre- quency waveforms and, therefore, must be used carefully to assure accurate harmonic analysis. There are a wide variety of instruments in this category. 3. Special-purpose power system harmonic analyzers. Besides the general-purpose spectrum analyzers just described, there are also a number of instruments and devices that have been designed specifi- cally for power system harmonic analysis. These are based on the FFT with sampling rates specifically designed for determining harmonic components in power signals. They can generally be left in the field and include communications capability for remote monitoring. 11.3.8 Combination disturbance and harmonic analyzers The most recent instruments combine harmonic sampling and energy monitoring functions with complete disturbance monitoring functions as well. The output is graphically based, and the data are remotely gathered over phone lines into a central database. Statistical analysis can then be performed on the data. The data are also available for input and manipulation into other programs such as spreadsheets and other graphical output processors. One example of such an instrument is shown in Fig. 11.13. This instrument is designed for both utility and end-user applications, being mounted in a suitable enclosure for installation outdoors on utility poles. It monitors three-phase voltages and currents (plus neutrals) simultaneously, which is very important for diagnosing power quality problems. The instrument captures the raw data and saves the data in internal storage for remote downloading. Off-line analysis is performed with powerful software that can produce a variety of outputs such as that shown in Fig. 11.14. The top chart shows a typical result for a volt- age sag. Both the rms variation for the first 0.8 s and the actual wave- form for the first 175 ms are shown. The middle chart shows a typical wave fault capture from a capacitor-switching operation. The bottom chart demonstrates the capability to report harmonics of a distorted waveform. Both the actual waveform and the harmonic spectrum can be obtained. Another device is shown in Fig. 11.15. This is a power quality moni- toring system designed for key utility accounts. It monitors three-phase voltages and has the capability to capture disturbances and page power Power Quality Monitoring 479 Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. quality engineers. The engineers can then call in and hear a voice mes- sage describing the event. It has memory for more than 30 events. Thus, while only a few short years ago power quality monitoring was a rare feature to be found in instruments, it is becoming much more commonplace in commercially available equipment. 11.3.9 Flicker meters* Over the years, many different methods for measuring flicker have been developed. These methods range from using very simple rms meters with flicker curves to elaborate flicker meters that use exactly tuned fil- ters and statistical analysis to evaluate the level of voltage flicker. This section discusses various methods available for measuring flicker. Flicker standards. Although the United States does not currently have a standard for flicker measurement, there are IEEE standards that address flicker. IEEE Standards 141-1993 6 and 519-1992 7 both contain 480 Chapter Eleven Figure 11.13 A power quality monitoring instrument capable of monitoring disturbances, harmonics, and other steady-state phenomena on both utility systems and end-user sys- tems. (Courtesy of Dranetz-BMI.) * This subsection was contributed by Jeff W. Smith and Erich W. Gunther. Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. Power Quality Monitoring 481 Phase C-A Voltage RMS Variation Trigger Phase A Voltage Wave Fault Phase A Current SS Wave Trigger 80 85 90 95 100 105 110 115 –150 –1.5 –600 0 20 40 60 80 100 –400 –200 0 200 400 600 1.5 –0.5 0.5 0 –1 1 –100 –50 0 50 100 150 Voltage (%)Voltage (%)Voltage (pu)Current (Amps)Amps 0 0 0 0 0 1020304050 10 20 30 40 50 10 20 30 40 50 60 70 25 50 75 100 125 150 175 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Time (s) Time (ms) Time (ms) Time (ms) Harmonic Duration 0.150 s Min 81.38 Ave 96.77 Max 101.4 Max 1.094 Min –1.280 Fund 267.5 RMS 281.0 CF 1.772 Min –495.6 Max 498.0 THD 30.67 HRMS 86.19 TIF/IT 70249 BMI/Electrotek Uncalibrated Data Figure 11.14 Output from combination disturbance and har- monic analyzer. Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. flicker curves that have been used as guides for utilities to evaluate the severity of flicker within their system. Both flicker curves, from Standards 141 and 519, are shown in Fig. 11.16. In other countries, a standard methodology for measuring flicker has been established. The IEC flicker meter is the standard for measuring flicker in Europe and other countries currently adopting IEC stan- dards. The IEC method for flicker measurement, defined in IEC Standard 61000-4-15 8 (formerly IEC 868), is a very comprehensive approach to flicker measurement and is further described in “Flicker Measurement Techniques” below. More recently, the IEEE has been working toward adoption of the IEC flicker monitoring standards with an additional curve to account for the differences between 230-V and 120-V systems. Flicker measurement techniques RMS strip charts. Historically, flicker has been measured using rms meters, load duty cycle, and a flicker curve. If sudden rms voltage devi- ations occurred with specified frequencies exceeding values found in flicker curves, such as one shown in Fig. 11.16, the system was said to have experienced flicker. A sample graph of rms voltage variations is shown in Fig. 11.17 where large voltage deviations up to 9.0 V rms (⌬V/V ϭ ± 8.0 percent on a 120-V base) are found. Upon comparing this to the flicker curve in Fig. 11.16, the feeder would be experiencing flicker, regardless of the duty cycle of the load producing the flicker, because 482 Chapter Eleven Figure 11.15 A low-cost power quality monitor that can page power quality engi- neers when disturbances occur. Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. any sudden total change in voltage greater than 7.0 V rms results in objectionable flicker, regardless of the frequency. The advantage to such a method is that it is quite simple in nature and the rms data required are rather easy to acquire. The apparent disadvantage to such a method would be the lack of accuracy and inability to obtain the exact frequency content of the flicker. Fast Fourier transform. Another method that has been used to measure flicker is to take raw samples of the actual voltage waveforms and Power Quality Monitoring 483 IEEE 141 IEEE 519 0.01 0.1 1 10 100 1000 10000 Changes/min ⌬V/V (%) 0.1 1 10 Figure 11.16 Flicker curves from IEEE Standards 141 and 519. Figure 11.17 RMS voltage variations. Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. implement a fast Fourier transform on the demodulated signal (flicker signal only) to extract the various frequencies and magnitudes found in the data. These data would then be compared to a flicker curve. Although similar to using the rms strip charts, this method more accurately quan- tifies the data measured due to the magnitude and frequency of the flicker being known. The downside to implementing this method is asso- ciated with quantifying flicker levels when the flicker-producing load contains multiple flicker signals. Some instruments compensate for this by reporting only the dominant frequency and discarding the rest. Flicker meters. Because of the complexity of quantifying flicker levels that are based upon human perception, the most comprehensive approach to measuring flicker is to use flicker meters. A flicker meter is essentially a device that demodulates the flicker signal, weights it according to established “flicker curves,” and performs statistical analysis on the processed data. Generally, these meters can be divided up into three sections. In the first section the input waveform is demodulated, thus removing the carrier signal. As a result of the demodulator, a dc offset and higher-fre- quency terms (sidebands) are produced. The second section removes these unwanted terms using filters, thus leaving only the modulating (flicker) signal remaining. The second section also consists of filters that weight the modulating signal according to the particular meter specifications. The last section usually consists of a statistical analysis of the measured flicker. The most established method for doing this is described in IEC Standard 61000-4-15. 8 The IEC flicker meter consists of five blocks, which are shown in Fig. 11.18. Block 1 is an input voltage adapter that scales the input half-cycle rms value to an internal reference level. This allows flicker measure- ments to be made based upon a percent ratio rather than be dependent upon the input carrier voltage level. Block 2 is simply a squaring demodulator that squares the input to separate the voltage fluctuation (modulating signal) from the main voltage signal (carrier signal), thus simulating the behavior of the incandescent lamp. Block 3 consists of multiple filters that serve to filter out unwanted frequencies produced from the demodulator and also to weight the input signal according to the incandescent lamp eye-brain response. The basic transfer function for the weighting filter is H(s) ϭ и 1 ϩ s/␻ 2 ᎏᎏᎏ ( 1 ϩ s/␻ 3)( 1 ϩ s/␻ 4) k␻ 1 s ᎏᎏ s 2 ϩ 2␭s ϩ␻ 1 2 484 Chapter Eleven Power Quality Monitoring Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies. All rights reserved. Any use is subject to the Terms of Use as given at the website. [...]... of Use as given at the website Power Quality Monitoring 492 Chapter Eleven 1.08 1.06 RCF 1.04 1.02 1 0.98 0.96 10 100 100 0 100 00 Frequency in Hertz 100 000 100 0000 Figure 11.21 Frequency response of a standard VT with 1-M⍀ burden 1.08 1.06 RCF 1.04 1.02 1 0.98 0.96 10 100 100 0 100 00 Frequency in Hertz 100 000 100 0000 Figure 11.22 Frequency response of a standard VT with 100 -⍀ burden Installation considerations... at the website Power Quality Monitoring Power Quality Monitoring Vin 493 Vin Vout Vout Good Figure 11.23 Capacitively coupled voltage dividers Bad 1.05 1 1/RCF 0.95 0.9 0.85 Equivalent circuit for determining CT frequency response primary ideal secondary transformer winding winding Zp Zs Ze 0.8 0.75 0.7 10 N:5 100 Cs Zb exciting stray impedance capacitance burden 100 0 100 00 100 000 100 0000 Frequency... power quality analysis software programs Samples: Minimum: Average: Maximum: 1404 6873.0806 7284.7099 7600.3726 100 % 120 80 Count 80% 70% 60% 50% 60 40% 40 30% 20% 20 Cumulative Frequency 90% 100 10% 0% 7590 7550 7 510 7470 7430 7390 7350 7 310 7270 7230 7190 7150 7 110 7070 7030 6990 6950 6 910 6870 0 V RMS A Figure 11.27 Histogram representation of rms voltage indicates the statistical distribution of... InfoNodes 11.3.11 Transducer requirements Monitoring of power quality on power systems often requires transducers to obtain acceptable voltage and current signal levels Voltage monitoring on secondary systems can usually be performed with direct connections, but even these locations require current transformers (CTs) for the current signal Many power quality monitoring instruments are designed for input... analysis 11.5 Application of Intelligent Systems Many advanced power quality monitoring systems are equipped with either off-line or on-line intelligent systems to evaluate disturbances and system conditions so as to make conclusions about the cause of the problem or even predict problems before they occur The applications of intelligent systems or autonomous expert systems in monitoring instruments help... take place within the instrument itself Thus, a new breed of power quality monitor was developed with integrated intelligent systems to meet this new challenge This type of power quality monitor is an intelligent power quality monitor where information is directly created within the instrument and immediately available to the users A smart power Downloaded from Digital Engineering Library @ McGraw-Hill... monitoring equipment capabilities 11.4 Assessment of Power Quality Measurement Data As utilities and industrial customers have expanded their power quality monitoring systems, the data management, analysis, and interpretation functions have become the most significant challenges in the overall power quality monitoring effort In addition, the shift in the use of power quality monitoring from off-line benchmarking... most power systems, this expert system module can be a significant benefit to power systems engineers in identifying problems and correlating them with capacitor-switching events Successful capacitor bank energization is characterized by a uniform increase of kvar on each phase whose total corresponds to the capacitor kvar size For example, when a 1200-kvar capacitor bank is energized, reactive power. .. subject to the Terms of Use as given at the website Power Quality Monitoring 494 Chapter Eleven Primary wound CTs are available from a variety of CT manufacturers Reference 2 concludes that any primary wound CT with a single turn, or very few turns, should have a frequency response up to 10 kHz End-user (secondary) sites Transducer requirements at secondary sites are much simpler Direct connection for... Range selector ⌬V 0.5 V 1.0 2.0 5.0 10. 0 20.0 Block 4 Power Quality Monitoring 485 Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com) Copyright © 2004 The McGraw-Hill Companies All rights reserved Any use is subject to the Terms of Use as given at the website Power Quality Monitoring 486 Chapter Eleven (See IEC Standard 6100 0-4-15 for a description of the . Eleven 0.96 0.98 1 1.02 1.04 1.06 1.08 RCF 10 100 100 0 100 00 100 000 100 0000 Frequency in Hertz Figure 11.21 Frequency response of a standard VT with 1-M⍀ burden. 10 100 100 0 100 00 100 000 100 000 0 Frequency in Hertz 0.96 0.98 1 1.02 1.04 1.06 1.08 RCF Figure. on the secondary of a pad-mounted transformer. Power Quality Monitoring 493 V out V out V in V in Good Bad Figure 11.23 Capacitively coupled voltage dividers. 10 100 100 0 100 00 100 000 100 000 0 0.7 0.75 0.8 0.85 0.9 0.95 1 1.05 Equivalent. Wave Trigger 80 85 90 95 100 105 110 115 –150 –1.5 –600 0 20 40 60 80 100 –400 –200 0 200 400 600 1.5 –0.5 0.5 0 –1 1 100 –50 0 50 100 150 Voltage (%)Voltage (%)Voltage (pu)Current (Amps)Amps 0 0 0 0 0 102 0304050 10 20 30 40 50 10 20 30 40 50 60 70 25 50 75 100 125 150 175 0.1 0.2 0.3

Ngày đăng: 08/08/2014, 15:21

Nguồn tham khảo

Tài liệu tham khảo Loại Chi tiết
2. A. McEachern, “Roles of Intelligent Systems in Power Quality Monitoring: Past, Present, and Future,” Conference Record, Power Engineering Society Summer Meeting, 2001, Vol. 2, pp. 1103–1105 Sách, tạp chí
Tiêu đề: Roles of Intelligent Systems in Power Quality Monitoring: Past,Present, and Future,” "Conference Record
3. R. P. Bingham, “Recent Advancements in Monitoring the Quality of the Supply,”Power Engineering Society Summer Meeting, 2001, Vol. 2, pp. 1106–1109 Sách, tạp chí
Tiêu đề: Recent Advancements in Monitoring the Quality of the Supply
4. Dranetz Engineering Laboratories, “Series 606 Power-Line Disturbance Analyzer,”December 1975 Sách, tạp chí
Tiêu đề: Series 606 Power-Line Disturbance Analyzer
5. E. W. Gunther, J. Rossman, “Application of Advanced Characterization Algorithms, UCA and Internet Communications Technology at the Point of Power Quantity and Quality Measurement,” Conference Proceedings of EPRI PQA 1999 Sách, tạp chí
Tiêu đề: Application of Advanced Characterization Algorithms,UCA and Internet Communications Technology at the Point of Power Quantity andQuality Measurement
6. IEEE Standard 141-1993: Recommended Practice for Power Distribution in Industrial Plants Sách, tạp chí
Tiêu đề: Recommended Practice for Power Distribution in
7. IEEE Standard 519-1992: Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems Sách, tạp chí
Tiêu đề: Recommended Practices and Requirements for Harmonic
8. IEC 61000-4-15, Electromagnetic Compatibility (EMC). Part 4: Testing and Measuring Techniques. Section 15: Flickermeter—Functional and Design Specifications Sách, tạp chí
Tiêu đề: Electromagnetic Compatibility (EMC)
9. D. A. Douglass, Potential Transformer Accuracy at 60-Hz Voltages above and below Rating and at Frequencies above 60 Hz. Presented at the IEEE Power Engineering Society Summer Meeting, Minneapolis, Minn., July 13–18, 1980 Sách, tạp chí
Tiêu đề: Potential Transformer Accuracy at 60-Hz Voltages above and below"Rating and at Frequencies above 60 Hz
10. D. A. Douglass, “Current Transformer Accuracy with Asymmetric and High Frequency Fault Currents,” IEEE Transactions on Power Apparatus on Systems, Vol.PAS-100, No. 3, March 1981 Sách, tạp chí
Tiêu đề: Current Transformer Accuracy with Asymmetric and HighFrequency Fault Currents,” "IEEE Transactions on Power Apparatus on Systems
11. S. Santoso, J. D. Lamoree, “Answer Module: A Custom-Built Module to Meet Specific Power Monitoring Tasks,” Conference Proceedings of EPRI PQA 2001, Pittsburgh, Pa Sách, tạp chí
Tiêu đề: Answer Module: A Custom-Built Module to Meet SpecificPower Monitoring Tasks
12. U. Fayyad, G. Piatetsky-Shapiro, P. Smyth, “From Data Mining to Knowledge Discovery: An Overview,” in U. Fayyad, G. Piatetsky-Shapiro, P. Smyth, R.Uthurusamy, eds., Advances in Knowledge Discovery and Data Mining, MIT Press, 1996, pp. 471–494 Sách, tạp chí
Tiêu đề: From Data Mining to KnowledgeDiscovery: An Overview,” in U. Fayyad, G. Piatetsky-Shapiro, P. Smyth, R.Uthurusamy, eds., "Advances in Knowledge Discovery and Data Mining
13. S. Santoso, R. C. Dugan, J. D. Lamoree, A. Sundaram, “Distance Estimation Technique for Single Line-to-Ground Faults in a Radial Distribution System,”Conference Record, Power Engineering Society Winter Meeting, 2000 IEEE, Vol. 4, pp. 2551–2555 Sách, tạp chí
Tiêu đề: Distance EstimationTechnique for Single Line-to-Ground Faults in a Radial Distribution System,”"Conference Record
14. S. Santoso, J. D. Lamoree, M. F. McGranaghan, “Signature Analysis to Track Capacitor Switching Performance,” Conference Record, Transmission and Distribution Conference and Exposition, 2001 IEEE/PES, Vol. 1, pp. 259–263 Sách, tạp chí
Tiêu đề: Signature Analysis to TrackCapacitor Switching Performance,” "Conference Record
17. IEEE Draft Standard P1159.3, Recommended Practice for a Power Quality Data Interchange Format—An Extensible File Format for the Exchange of Power Quality Measurement and Simulation Data, SCC 22.11.8 Bibliography Sách, tạp chí
Tiêu đề: Recommended Practice for a Power Quality Data"Interchange Format—An Extensible File Format for the Exchange of Power Quality"Measurement and Simulation Data

TỪ KHÓA LIÊN QUAN