Water Cooled Packaged Air Conditioners UC(P)J Series –– Cooling Only –– ED 46 – 1A ENGINEERING DATA Water Cooled Packaged Air Conditioners UCPJ 100N UCJ 500P 170P 670P 250P 850N 335P 1000P 1320P 1600N 2000N CONTENTS 1. Features 1 2. Specifications 2 3. Standard accessories 5 4. Optional accessories 5 5. Dimensions 6 6. Wiring diagrams 9 7. Capacity tables 15 8. Pressure drop 23 9. Fan performance 24 10. Operation limit 29 11. Sound level data 30 12. Electric characteristics 32 13. Center of gravity 33 14. Wiring connections 34 15. Service space 34 16. Caution 35 1 The Daikin Water Cooled Packaged Air Conditioners are available in 14 models from UCPJ100N(9.4/10.4kW, 50/60Hz) to UCJ2000N(193.5/213.9kW, 50/60Hz). The light and compact construction ensures easy installation in any building whether new or existing. They are ideally suited to cooling offices, banks theaters, restaurants, etc. In case an optional heater (listed on page 5) is fitted, comfortable heating is also possible. You can choose the model best suited to your requirements from the wide range available in this series. UC(P)J100N~670P : Designed for operation with ducting, but an optional plenum chamber (except UCPJ100N) is mounted on a unit, it can be installed directly in a room without ducting. UCJ850N~2000N : Designed for operation with ducting only. Easy installation: These self-contained units are assembled internally wired and charged with refrigerant in the factory and are subjected to a stringent test run before delivery. All that is required on the spot are water piping, wiring to the main power supply and ducting. The weight of the models smaller than UCJ2000N has been greatly reduced for easy handling. Economical operation: An electronic thermostat precisely controls compressor operation according to room temperature to save power. UCJ500P~2000N: Cooling is controlled in 2 or 4 steps by an unloader mechanism or on/off operation of a compressor in the 2 or 3 refrigerant circuits according to cooling load. Easy operation and maintenance: Operation is very easy and controlled centrally from the control panel fitted on the front of the units. A red pilot lamp indicates normal operation, and white lamp indicates abnormal operation. ln addition, various pressure gauges are connected to each refrigerant circuit for easy monitoring. ¡The switches, gauges, pilot lamps on the control panel are as follows: UCPJ100N~335P: Master control knob, selector switch for COOL/HEAT, thermostat knob, red pilot lamp, high pressure reset button. UCJ500P~2000N: Master control switch, selector switches for COOL/HEAT and LOCAL/REMOTE, thermostat knob, red pilot lamp, white pilot lamp, high pressure reset button, discharge pressure gauge (Except UCJ500P·670P), suction pressure gauge (Except UCJ500P·670P). ¡A selector switch and terminal for remote control are fitted to UCJ500P~2000N for remote operation. ¡A washable air filter is fitted on all models. It can be easily detached for cleaning. Quiet: Quiet multi-blade fans and hermetically sealed compressors mounted with vibration isolation rubber pads (Models smaller than UCJ2000N) ensure quiet operation. In addition, the air passage inside the unit is designed to minimize air resistance for quiet operation. Main components: ¡Daikin developed highly efficient and compact compressors that are equipped with various safety devices for additional reliability and durability. UCPJ100N: A hermetically sealed rotary compressor lubrication system with the eccentric hole is incorporated. UC(P)J170~670P, 1000P, 1320P: Adoption of scroll compressor UCJ850N, 1600N, 2000N: The hermetically sealed reciprocating type compressor is adopted. The lubrication method is of the eccentric hole system. ¡The eveporator is of the unique patented cross fin coil type. Waffle louver fins *1 or Waffle fins and Hi-X tubes *2 (with internal surface modified by serration) are used to greatly improve the heat exchange coefficient. ¡The condenser is also an usually efficient heat exchanger. UC(P)J100N~1320P: The double tube type condenser with corrugated and wire or needle shaped fin inner tubes are used to increase heat transfer efficiency. UCJ1600N~2000N: The shell and cross fin tube type condenser is used. The refrigerant can be pumped down by using the stop valves at the condenser outlet and the compressor discharge side. ¡The evaporator fan is of the dual suction multi-blade type and is V belt driven. Operative air flow range is widened for UC(P)J100N~2000N. In paticular, a variable pitch pulley is attached to UC(P)J100N~670P for ease of ducting. ¡The evaporator fan motor is equipped with a thermal protector or an overcurrent relay for safe operation. Water Cooled Packaged Air Conditioners UC(P) Series 1. Features Waffle louver fins Hi-X tube 2 2. Specifications Model Cooling capacity 50/60Hz (*1) Cooling capacity 50/60Hz (*2) Capacity steps Casing/Color Compressor Refrigeration oil Condenser Evaporator Evaporator fan Refrigerant Air filter (Factory set) Electronic thermostat Pipe connections Dimensions Weight (Operating weight) Weight with optional plenum chamber (Operating Conversion formulae kcal/h=kW҂860 Btu/h=kW҂3414 cfm=m 3 /min҂35.3 NOTES: 1. (*1) Cooling capacities are based on the following operating conditions: Indoor air temp·······27°C DB, 19.5°C WB (*2) Cooling capacities are based on the following operating conditions: Indoor air temp·······27°C DB, 19.0°C WB Leaving Condenser water temperature : 35°C 2. Cooling capacities are gross capacities which do not include a deduction for evaporator fan motor heat. kW Btu/h kcal/h kW Btu/h kcal/h % r.p.m. R R/min. mm m 2 m 3 /min. cfm kW kg mm kg kg UCPJ100N 9.4/10.4 32,100/35,500 8,100/8,900 9.2/10.2 31,400/34,800 7,900/8,800 100–0 Hermetically sealed rotary 1iRC112 –– 2,850/3,400 SUNISO 3GSD 0.9 Double tube 1iCDW-UC3J 30/35 3i18 2.5 0.274 D1 1 / 2 D 25 880 0.4 R22 1.1 Capillary tube 1 Resin net 1 step FPT 3 / 4 B FPS1B/FPS 1 / 2 B 1,700i750i380 125(128) –– UCPJ170P 17.5/18.5 59,700/63,200 15,100/15,900 17.1/18.1 58,400/61,800 14,700/15,600 100–0 1iJT150BYE –– 2,900/3,450 1.0 1iCDW-UC5J 55/61 2i26 2.0 0.443 2D1 5 / 8 A 53 1,870 0.75 1.2 1 FPT1B FPS1B/FPS 1 / 2 B 1,640i950i510 180(184) 195(199) UCPJ250P 24.6/27.3 84,000/93,200 21,200/23,500 24.1/26.8 82,300/91,500 20,700/23,000 100–0 1iJT224AYE –– 2,900/3,450 2.0 1iCDW-UC8J 80/92 2i26 2.0 0.575 2D1 3 / 4 G2 80 2,820 0.75 1.9 1 FPT 1 / 4 B FPS1B/FPS 1 / 2 B 1,640i1,170i510 220(226) 236(242) UCPJ335P 34.5/36.5 117,800/124,600 29,700/31,400 33.8/35.8 115,400/122,200 29,100/30,800 100–0 1iJT280AYE –– 2,900/3,450 2.0 1iCDW-UC10J 112/123 2i26 2.0 0.746 2D1 3 / 4 G3 107 3,780 1.5 2.1 1 FPT 1 / 4 B FPS1B/FPS 1 / 2 B 1,640i1,470i510 260(268) 277(285) UCJ500P 50.2/52.8 171,400/180,300 43,200/45,400 49.2/51.7 168,000/176,500 42,300/44,500 100–50–0 Cold rolled steel plate/Ivory white 2iJT224AYE –– 2,900/3,450 2҂2.0 1iCDW-UC15J 160/175 3i32 2.0 0.894 2D2E 135 4,770 2.2 2i2.0 2 2 step FPT1 1 / 2 B FPS1B/FPS1B 1,870i1,470i720 445(457) 472(484) Type No. i Model No. of cylinders Speed 50/60Hz Model Charge Type No. i Model *1 Water flow rate 50/60Hz Coil Row i stage Fin pitch Face area Type Model Drive Air flow rate 50/60Hz Motor output Model Charge Control No. of circuits Condenser water inlet/outlet Drain-Upper/lower HiWiD Hermetically sealed Scroll SUNISO 4GSDID-K Cold rolled steel plate/Casing: Ivory white, Air suction grille:Light camel Cross fin coil (waffle louver fins and Hi-X tubes) Dual suction multi-blade Belt with adjusting pulley [50/60Hz] 3 Model Cooling capacity 50/60Hz (*1) Cooling capacity 50/60Hz (*2) Capacity steps Casing/Color Compressor Refrigeration oil Condenser Evaporator Evaporator fan Refrigerant Air filter (Factory set) Electronic thermostat Pipe connections Dimensions Weight (Operating weight) Weight with optional plenum chamber (Operating weight) Conversion formulae kcal/h=kW҂860 Btu/h=kW҂3414 cfm=m 3 /min҂35.3 NOTES: 1. (*1) Cooling capacities are based on the following operating conditions: Indoor air temp·······27°C DB, 19.5°C WB (*2) Cooling capacities are based on the following operating conditions: Indoor air temp·······27°C DB, 19.0°C WB Leaving Condenser water temperature : 35°C 2. Cooling capacities are gross capacities which do not include a deduction for evaporator fan motor heat. UCJ670P 66.6/70.7 227,400/241,400 57,300/60,800 65.3/69.3 222,900/236,600 56,200/59,600 100–50–0 Hermetically sealed scroll 2iJT280AYE –– 2,900/3,450 2i2.0 Double tube 1iCDW-U20J 214/236 3i32 2.0 1.133 2D2E 180 6,360 3.7 R22 2i2.0 Capillary tube 2 Resin net 2 steps FPT2B FPS1B/FPS1B 1,870i1,810i720 495(510) 527(542) UCJ850N 84.6/89.7 288,800/306,300 72,800/77,100 82.9/87.9 283,000/300,100 71,300/75,600 100–60–0 Hermetically sealed reciprocating 1i6T55FA 1i3T55RF 1i6.1i3 2,900/3,450 6.1e2.7 1iCDN-UC25J 266/293 3i48 2.0 1.63 D3C 225 7,940 3.7 4.2e2.8 2 FPT2B FPS1 1 / 4 B/FPS1B 1,850i1,600i1,050 700(722) –– UCJ1000P 101.0/106.1 344,800/362,200 86,900/91,200 99.0/104.0 338,000/355,100 85,100/89,400 100–50–0 3iJT280AYE –– 2,900/3,450 5.4e2.7 1iCDN-UCJ1000PA 324/354 3i48 2.0 1.83 D3C 270 9,530 5.5 5.6e2.8 2 FPT2 1 / 2 B FPS1 1 / 4 B/FPS1B 1,850i1,760i1,050 735(760) –– UCJ1320P 133.4/140.5 455,500/479,700 115,800/120,800 130.7/137.7 446,200/470,100 112,400/118,400 100–50–0 4 i JT280AYE –– 2,900/3,450 2i5.4 1iCDW-UC40JA 430/472 3i56 2.0 2.39 2D2 1 / 2 D 360 12,700 7.5 2i5.6 2 FPT2 1 / 2 B FPS1 1 / 4 B/FPS1B 1,850i1,960i1,200 974(1002) –– UCJ1600N 150.3/170.7 513,200/582,800 129,300/146,800 147.3/167.3 502,900/571,200 126,700/143,900 100–50–0 Hermetically sealed reciprocating 2i6T55WACS 2i6 2,900/3,450 2i6.1 Shell and cross fin tube 1iCXCD2418 478/548 4i64 2.0 2.73 2D2 1 / 2 D 420 14,800 11 2i9.6 Thermal expansion valve 2 FPT3B FPS1 1 / 2 B/FPS1B 1,850i1,960i1,200 1,150(1,174) –– kW Btu/h kcal/h kW Btu/h kcal/h % r.p.m. R R/min. mm m 2 m 3 /min. cfm kW kg mm kg kg Type No. i Model No. of cylinders Speed 50/60Hz Model Charge Type No. i Model *1 Water flow rate 50/60Hz Coil Row i stage Fin pitch Face area Type Model Drive Air flow rate 50/60Hz Motor output Model Charge Control No. of circuits Condenser water inlet/outlet Drain-Upper/lower HiWiD SUNISO 4GSDID-K Cold rolled steel plate/Ivory white Hermetically sealed scroll Cross fin coil (waffle louver fins and Hi-X tubes) Dual suction multi-blade Belt with adjusting Belt pulley [50/60Hz] 4 Model Cooling capacity 50/60Hz (*1) Cooling capacity 50/60Hz (*2) Capacity steps Casing/Color Compressor Refrigeration oil Condenser Evaporator Evaporator fan Refrigerant Air filter (Factory set) Electronic thermostat Pipe connections Dimensions Weight (Operating weight) Conversion formulae kcal/h=kW҂860 Btu/h=kW҂3414 cfm=m 3 /min҂35.3 kW Btu/h kcal/h kW Btu/h kcal/h % r.p.m. R R/min. mm m 2 m 3 /min. cfm kW kg mm kg UCJ2000N 193.5/213.9 660,650/730,300 166,400/184,000 189.6/209.6 647,300/715,600 163,100/180,300 100–67–0 Hermetically sealed reciprocating 3i6T55TACS 3i6 2,900/3,450 3i6.1 Shell and cross fin tube 1iCXCD2422 617/708 4i64 2.0 3.38 2D3C 540 19,100 11 R22 3i8.5 Thermal expansion valve 3 Resin net 2 steps FPT3B FPS1 1 / 4 B/FPS1B 1,850i2,360i1,200 1,360(1,391) Unit size Compressor thermal protector Overcurrent relay (Comp.) Overcurrent relay (Fan motor) High pressure switch Fusible plug Reverse phase protector 100 Ț Ț – Ț Ț Ț 170 Ț Ț Ț Ț Ț Ț 250 Ț Ț Ț Ț Ț Ț 335 Ț Ț Ț Ț Ț Ț 500 Ț Ț Ț Ț Ț Ț 670 Ț Ț Ț Ț Ț Ț 850 Ț Ț Ț Ț Ț – 1000 Ț Ț Ț Ț Ț Ț 1320 Ț Ț Ț Ț Ț Ț 1600 Ț Ț Ț Ț Ț – 2000 Ț Ț Ț Ț Ț – Safety devices The following safety devices are standard. NOTES: 1. (*1) Cooling capacities are based on the following operating conditions: Indoor air temp·······27°C DB, 19.5°C WB (*2) Cooling capacities are based on the following operating conditions: Indoor air temp·······27°C DB, 19.0°C WB Leaving Condenser water temperature : 35°C 2. Cooling capacities are gross capacities which do not include a deduction for evaporator fan motor heat. Type No. i Model No. of cylinders Speed 50/60Hz Model Charge Type No. i Model *1 Water flow rate 50/60Hz Coil Row i stage Fin pitch Face area Type Model Drive Air flow rate 50/60Hz Motor output Model Charge Control No. of circuits Condenser water inlet/outlet Drain-Upper/lower HiWiD Cold rolled steel plate/Ivory white SUNISO 4GS DID-K Cross fin coil (Waffle louver fins and Hi-X tubes) Dual suction multi-blade Belt [50/60Hz] 5 { Power supply SYMBOL YE Power supply 3C, 380~415/400~440V, 50/60Hz (3 wires) Available model UCPJ100N UCPJ170P UCPJ250P UCPJ335P UCJ500P UCJ670P UCJ850N UCJ1000P UCJ1320P UCJ1600N UCJ2000N 3. Standard accessories 1. Operation manual 2. Installation manual 3. Bolts, nuts for duct flange (UC(P)J170~2000) 4. V-pulley for fan motor (UCJ850~2000) 5. V-belt (UCJ850~2000) 4. Optional accessories * 1. Electric heater (UC(P)J100~670) 2. Hot Water heater 3. Steam heater 4. Evaporating pan type humidifier (UC(P)J100~1600) 5. Steam spray type humidifier 6. Water spray type humidifier * 7. Fan motor pulley change [Evaporator fan]Ƞ * 8. Fan motor 1 size larger [Evaporator fan] Ƞ(except UCPJ100) 9. Fresh air intake (UC(P)J100~670) 10.Rear suction inlet (UC(P)J100~670) 11.Plenum chamber (UC(P)J170~670) 12.Side discharge grille for plenum chamber (UC(P)J100~670) 13.Pressure gauge (UC(P)J100~670) 14.Condenser water interruption relay Note: * These options should be attached in DAlKIN factory. Field modification are not available. Ƞ In case ordering these modifications, inform "Air flow rate (m 3 /min)"&"External static pressure (mmH2O)" 6 5. Dimensions UCPJ100N UCPJ170P·250P·335P Model UCPJ170P UCPJ250P UCPJ335P F 974 1194 1494 E 924 1144 1444 D 27.5 35 20 C 280 330 430 B 695 870 1140 A 950 1170 1470 q Condenser water inlet UCPJ170P: FPT1B UCPJ250P: FPT1 1 /4B UCPJ335P: FPT1 1 /4B w Condenser water outlet UCPJ170P: FPT1B UCPJ250P: FPT1 1 /4B UCPJ335P: FPT1 1 /4B e Upper drain FPS1B r Lower drain FPS 1 /2B t Power supply intake C 45 hole y Grounding terminal in M6 bolt switch box u Anchor bolt set plate 4-C15 hole (detachable) Note:q~t can be provided either on the left or the right side of the unit. (Unit: mm) (Unit: mm) 7 UCJ500P·670P UCJ850N·1000P Model UCJ850N UCJ1000P D 1400 1560 C 1620 1780 B 1570 1730 A 1600 1760 q Condenser water inlet UCJ850N: FPT2B UCJ1000P: FPT2 1 /2B w Condenser water outlet UCJ850N: FPT2B UCJ1000P: FPT2 1 / 2 B e Upper drain FPS1 1 /4B r Lower drain FPS1B t Power supply intake C58 hole y Grounding terminal in M6 bolt switch box u Anchor bolt set plate 4-C17 hole (detachable) Note: q~t can be provided either on the left or the right side of the unit. (Unit: mm) (Unit: mm) Model UCJ500P UCJ670P E 1445 1785 D 1470 1810 C 1495 1835 B 115 180 A 540 680 q Condenser water inlet UCJ500P: FPT1 1 /2 B UCJ670P: FPT2B w Condenser water outlet UCJ500P: FPT1 1 /2B UCJ670P: FPT2B e Upper drain FPS1B r Lower drain FPS1B t Power supply intake C58 hole y Grounding terminal in M6 bolt switch box u Anchor bolt set plate 4-C17 hole (detachable) Note: q~t can be provided either on the left or the right side of the unit. 8 UCJ1320P UCJ1600N· 2000N (Unit: mm) (Unit: mm) [...]... size҂No Air flow rate range UCPJ100N UCPJ170P UCPJ250P 3 phase, 4 pole, E class insulation 1410/1700 1420/1700 1420/1700 0.4 0.75 0.75 –– 1.5 2.2 1500 1600 1600 AR9 9-6 5-1 4 (Variable dia.) A16 9-2 5 (Fixed dia.) A28҂1 m3/min 20~33 AL12 9-1 0 0-1 9 (Variable dia.) A19 5-2 5 (Fixed dia.) A42҂1 36~64 AL10 4-7 5-1 9 (Variable dia.) A14 9-2 5 (Fixed dia.) A43҂1 54.5~96 UCPJ335P 1420/1700 1.5 2.2 1600 AL12 9-1 0 0-2 4 (Variable... 50Hz:2B16 1-2 8 60Hz:2B13 6-2 8* Fan pulley 2B32 6-4 5 50Hz:B73҂2 V belt size҂No 60Hz:B71҂2* m3/min 150~300 Air flow rate range UCJ1000P UCJ1320P UCJ1600N 3 phase, 4 pole, B class insulation 1440/1730 5.5 7.5 1100 1440/1730 7.5 15 1300 1450/1740 11 18.5 1300 50Hz:2B16 1-3 8 60Hz:2B13 6-3 8* 2B32 6-4 5 50Hz:B73҂2 60Hz:B71҂2* 180~360 50Hz:2B17 1-3 8 60Hz:2B14 3-3 8* 3B29 1-3 5 50Hz:B70҂3 60Hz:B68҂3* 240~480 50Hz:3B19 1-4 2 60Hz:3B16 1-4 2*... Secondary 380V 200V Transformer 400, 440V 200, 220V 415V 200V ––– Reverse phase 380V protection ––– 400, 415, 440V Terminal *U-V1 U-V2 U-V3 *R-S-T1 R-S-T2 UCJ1320P UCJ1600N Symbols 2C 2CX, 3X 6C 10 10X 20RS 23A 30FX 30FY 42C 43CH 47 49C 51C 51F 52C 52F 63H BS Timing relay ( - Change) Magnetic relay Magnetic relay Magnetic contactor (MC) Timing relay (5 sec) Magnetic relay Solenoid valve (start) Thermostat... Max replaceable output kW Max fan speed r.p.m Pulley size Motor pulley Fan pulley V belt size҂No Air flow rate range UCJ670P UCJ500P 3 phase, 4 pole, E class insulation 1420/1710 1420/1710 3.7 2.2 5.5* 3.7 1600 1600 BR15 1-1 1 5-2 8 (Variable dia.) B23 5-3 5 B40҂1 m3/min 90~165 BR16 1-1 2 5-2 8 (Variable dia.) 2B23 5-3 5 B41҂1 120~220 Remarks: *The number of V belts to be used should be changed from one to two when... (m3/min)i(1-BF)i(DB-EDB)/860 5 Direct interpolation is permissible Do not extrapolate 22 8 Pressure drop UCPJ100NYE UCPJ170PYE UCPJ250PYE UCPJ335PYE UCJ500PYE UCJ670PYE UCJ850NYE UCJ1000PYE UCJ1320PYE UCJ1600NYE UCJ2000NYE Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow... (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) Water flow rate (R/min) Pressure Drop (kPa) 23 10 20 30 32 37 40 45 2.9 10.8 23.5 27.4 37.2... Variable resistor (23A) VR Pilot lamp (Alarm-White) WL Field supply: Auxiliary contact (lnterlock) AXP Notes: 1 : Terminal of TeS : Jumper : Additional wiring for remote control 2 : The wiring to interlock with condenser water pump (Remove the jumper wire between (1) and (2) on TeS2 and connect "AXP".) 3 Connection of transformer is as follows Terminals U-V1 U-V2 U-V3 Primary/Secondary YE Model 380V/200V... lamp (Operation-Red) RL Selector switch (Local-Remote) SS1 Selector switch (Cool-Heat) SS2 TeS1·2 Terminal strip Thermistor (23A) Th Transformer Tr Variable resistor (23A) VR WL1·2 Pilot lamp (Alarm-White) Field wiring and optional Accessories Auxiliary contact (lnterlock) AXP Notes: 1 : Terminal : Field wire : Jumper : Printed circuit board 2 The wiring to interlock with the cooling water pump (Remove... 189.3 125.5 581 : Air flow rate : Bypass factor : Entering wet bulb temp : Total capacity : Sensible heat capacity : Condenser water flow rate : Pressure drop (Cooling water) : Power input (compressor) PD 27.6 31.2 33.2 40.3 46.3 32.2 36.6 38.9 47.0 54.6 36.1 45.8 43.5 53.2 61.3 (m3/min) (°CWB) (kW) (kW) (l/min.) (kpa) Notes: 1.Figures in show nominal capacities 2.Capacity and condenser water flow rate... 302.8 191.8 – : Air flow rate : Bypass factor : Entering wet bulb temp : Total capacity : Sensible heat capacity : Condenser water flow rate : Pressure drop (Cooling water) : Power input (compressor) (m3/min) (°CWB) (kW) (kW) (l/min.) (kpa) (kW) PD 28.1 32.6 35.0 42.8 49.8 33.7 38.3 40.7 50.2 58.5 37.5 42.4 45.0 55.9 – Notes: 1.Figures in show nominal capacities 2.Capacity and condenser water flow rate . Water Cooled Packaged Air Conditioners UC(P)J Series –– Cooling Only –– ED 46 – 1A ENGINEERING DATA Water Cooled Packaged Air Conditioners UCPJ 100N UCJ 500P 170P. phase protection Power source 3 phase 380~415/400~440V 50/60Hz Voltage Terminal *U-V1 U-V2 U-V3 *R-S-T1 R-S-T2 Table1 Table2 Primary 380V 400, 440V 415V 380V 400, 415, 440V Secondary 200V 200,. thermal protector or an overcurrent relay for safe operation. Water Cooled Packaged Air Conditioners UC(P) Series 1. Features Waffle louver fins Hi-X tube 2 2. Specifications Model Cooling capacity 50/60Hz