1. Trang chủ
  2. » Khoa Học Tự Nhiên

báo cáo hóa học:" Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique" pot

6 503 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 6
Dung lượng 1,46 MB

Nội dung

RESEA R C H ART I C L E Open Access Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique Matthias Jacobi * , Peter Wahl, Georges Kohut Abstract Background: A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. Methods: Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were followed prospectively during 24 months. Outcome measures included radiographic follow-up, range of motion, grip strength and score follow-up (VAS, Gartland-Werley score and patient-rated wrist evaluation). Results: Ten patients with intraarticular distal radius fractures with dislocation of the radial styloid process were treated with this technique. This resulted after 24 months in good clinical outcome (mean visual analog scale 0.9; almost symmetric range of motion; mean Gartland-Werley score 2 ± 3; mean patient-rated wrist evaluation 3.2 ± 2.4). Radiologic evaluation according to the Dresdner Score revealed anatomic reduction without secondary dislocation during the follow-up and uneventful consolidation. Conclusions: The described technique strongly facilitates anatomic reduction and stable fixation of intra-articular distal radius fractures with dislocation of the radial styloid process and leads to satisfactory clinical and radiographic outcome. Background During the last decade , open reduction-internal fixation (ORIF) has become increasingly popular, and is used more frequently for distal radius fractures [1-7]. It pro- vides some advantages over external percutaneous fixa- tion techniques. The functional (and therefore faster) rehabilitation is advantageous; it allows for an earlier return to work and less wound care is needed. Never- theless, final outcome is similar [8,9]. There has been a tendency during the last five years for ORIF to be done predominantly with volar implants and angular stability [10,11]. With this technique, most fracture types can be treated with good-to-excellent results. Functional outcome is similar to results obtained by a dorsal approach, avoiding tendon irritation [6,10,12]. Implant removal is therefore dispensable in many cases. A possible difficulty during reduction of distal radius fractures can be the proximal displacement and radial shift of the radial styloid process, due to the tension of the brachioradialis tendon (figure 1). This problem is often encountered in comminuted, intra-articular, and/ or osteoporotic fractures. Due to patient positioning (i.e., supine position with the arm abducted; elbow extended with the forearm supinated), tension in the brachioradialis tendon is increased, which in turn wor- sens dislocation. Tendon release (as suggested by Orbay), direct and indirect manipulation, ligamentotaxis, the Willenegger o r Kapandji technique and a change in arm position (to flexion of the elbow and pronation of the forearm) may ease repositioning [5,13,14]. * Correspondence: ortho@mjacobi.ch Department of Orthopaedic Surgery, Hôpital Cantonal Fribourg, 1708 Fribourg, Switzerland Jacobi et al . Journal of Orthopaedic Surgery and Research 2010, 5:55 http://www.josr-online.com/content/5/1/55 © 2010 Jacobi et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provide d the origin al work is properly cited. Nevertheless, this can be insu fficient to reduce the sty- loid process to an anatomic position. The three-column concept of the distal radius as proposed by Rikli respects radial dislocation of the styloid process and fixes the radial column with a separate plate [15,16]. A similar principle can also be used with volar fixation. One main difference is that the radial plate in the Riklis technique worksinthesagittalplaneandisnotonlyabuttress plate, but also fixes the fracture. In this report on single-approach radio-volar plating, we describe a simple technique to overcome the disloca- tion tendency of the radial styloid process and ease ana- tomic reduction. We deta il this surgical technique with clinical and radiological outcome of treated patients. Methods A consecutive series of patients treated with radio-volar double plate fixation (radial buttress plate and volar locked plate) for fractures of the distal radius between 1 January and 31 December 2006 at our institution were selected and controlled prospectively for this study. Patients requiring supplementary fixation (e.g., dorsal plating or a supplementary approach such as a dorsal approach) where excluded. Indication for volar and, if judged necessary, radial plating, was a choice of the surgeon on call based on standard recommendations in our depart ment. A radial plate was used only in cases of difficult repositioning with radial shift and proximal displacement of the sty- loid process if satisfactory reduction was not achieved otherwise (see background). The decision to add a radial plate was therefore taken intraoperatively. Preoperatively, plain radiographs were taken and in six cases CT was done (one patient was too obese, and in three cases the surgeon considered it to be unnecessary). Surgery was carried out immediately or once soft-tissue swelling was acceptably low. Surgical technique Patients were placed on the operating table in the supine position with abduction of the arm and supina- tion of the forearm. A tourniquet was used, and stan- dard disinfection and draping carried out. A distal Henry approach was carried out in the interval between the flexor carpi radialis tendon and the radial artery. The distal part of the pronator quadratus muscle was released from the radius. Care was taken to release only the amount of muscle necessary for fracture exposure and plate insertion. In most cases, the proximal part of the plate was placed under the main body of the prona- tor quadratus muscle. The brachioradialis tendon was partially released from the radial aspect of the styloid; fibers that insert proximally to the fracture remained intact, but most of the fibers that insert onto t he styloid fragment were sectioned, without Z-lengthening. We assumed that the remaining insertion o f the brachiora- dialis would be sufficient to hold this tendon in an appr opriate place during fracture healing. If needed , the sheath of the abductor l ongus and extensor brevis ten- dons was sectioned, but care was taken to avoid direct contact between these tendons and the plate on the radial side. Satisfactory anatomic repositioning and/or stabilization of the radial styloid process was not possi- ble in all patients, so a radial plate, through the same approach, was added. An AO 2.7-mm 1/3-tube plate (Synthes®, Oberdorf, Switzerland) or a straight Aptus Radius plate, 2.5 mm (Medartis®, Basel, Switzerland) was use d in all cases. The plate was fixed as a buttress plate with one or two screws in the radial aspect of the radial shaft, just proximal to the fracture line. With this, repo- sitioning of the fracture in the frontal plane was achieved (figure 1). The main volar plate (Aptus Radius, 2.5 mm; Medartis®) was added after definitive reposi- tioning of the fracture in the sagit tal plane. Screws with angular stability were used with this plate; we tried to place at least 2-3 screws in the radial styloid process. After fluoroscopic control, closure was by adaptation of the pronator quadratus muscle with absorbable sutures, and suture of the skin with non-resorbable sutures. Rehabilitation Active motion of fingers, elbow and f orearm in prona- tion and supination without weight bearing was started 2-3 days after surgery for all patients. The wrist was supported on a removable splint for 6 weeks, but gentle range-of-motio n exercises for flexion and extension were initiated. Weight bearing was allowed after 6 weeks if there was radiographic evidence of fracture healing. Figure 1 Rad ial styloid dislocation and reduction. Dislocation of the radial styloid process is favored by the traction of the brachioradialis tendon. The radial buttress plate reduces displacement and neutralizes brachioradialis traction. Jacobi et al . Journal of Orthopaedic Surgery and Research 2010, 5:55 http://www.josr-online.com/content/5/1/55 Page 2 of 6 Outcome evaluations Clinical and radiographic outcome evaluation s were doneat6weeks,3,6,12and24monthsaftersurgery. Range of motion was noted. Grip strength was measured with JAMAR hand dynamome ter (JAMAR TEC, Clifton, New Jersey). Pain was evaluated with the visual analog scale [17]. Additionally all patients completed the Gart- land and Werley score [18] and the patient-rated wrist evaluation [19]. Radiological analysis included fracture AO-classification. Preoperatively and postoperatively, joint inclination in the l ateral view, radial inclination in the anteroposterior view, loss of radial length, as well as intra-articular steps were evaluated according to the Dresdner Score (figure 2, table 1) [20]. Time until consolidation was determined evaluating callus formation, gap-filling and restoration o f bone architecture. Statistical Analysis Results were expressed as arithmetic mean (standard error of mean/and range). Calculations were performed using SPSS 15.0 LEAD Technologies, Inc Results Baseline data During the study period, 104 distal radius fractures were surgically treated at our institution. Of these, 53 were treated with a volar plate and, of these, 1 0 received an additional radial buttress plate and were therefore included in the study. Five patients were female and five were male; four left- and six right-sided fractures were involved. The mean age was 54 years (range, 20-82 years). Four patients were aged ≤36 ye ars (high-energy trauma) and six subjects were ≥55 years (low-energy trauma with osteoporosis). All but one (23C2) were AO type 23C3 fractures. Four fractures had a volar tilt, and six had a dorsal tilt. All patients were availabl e for com- plete follow-up. All patients underwent surgery by three surgeons experienced in treating patients who had undergone orthopaedic trauma. Clinical data The mean visual analog scale at 24 months was 0.9. Range of motion was: flexion 39° (± 14.6/range 15-60); extensi on 49° (± 8.1/range 10-60) pronation: 75° (± 8.3/ range 60-90); and supination: 75° (± 8.1/range 65-90). The mean Gartland and Werley score at 24-month fol- low-up was 2 (± 3/range 0-10) in which eight patients were rated as “ excellent” ,oneas“good” and one as “fair” . The mean patient-rated wrist evaluation was 3.2 (± 2.4/range 0-7) at 24-month follow-up. Grip strength was 90% (± 9/range 80-100) of the opposite side with seven dominant and three non-dominant wrists involved. The available clinical data between 6 months and 24 months were virtually unchanged. Five of the patients had slight DeQuervain’s tendonitis-like symp- toms caused by the radial plate, and benefited from implant removal. Radiological data The initial sagital tilt for the four v olar-tilted fractures was 20° (± 12/range 4-30), and -26.5°(± 6.7/range -20 to -60) for the six dorsal tilted fractures, and was equal Figure 2 Radiologic evaluation. Radiologic evaluation according to the Dresdner Score included (i) volar inclination; (ii) radial inclination; (iii) loss of radial length and (iv) intraarticular steps. Table 1 Radiologic evaluation according to the Dresdner Score Parameter Rating Points Preoperative (n) Postoperative (n) Volar inclination Norm 5-15° 0 - 8 Deviation 5- 10° 12 2 Deviation >10° 28 - Loss of radial length Till 2 mm 0 - 10 3-4 mm 1 2 - > 4 mm 2 8 - Radial inclination 20-25° 0 - 6 Deviation 5- 10° 15 4 Deviation >10° 25 - Joint line No steps 0 - 8 Steps till 2 mm 12 1 Steps >2 mm 28 1 Mean total points preoperative 6.9 Mean total points postoperative 0.9 Jacobi et al . Journal of Orthopaedic Surgery and Research 2010, 5:55 http://www.josr-online.com/content/5/1/55 Page 3 of 6 postoperatively and at 24 months for both groups 7.5°(± 3.5/range 0-12). Preoperative loss of radial length was 6.3 mm (± 3.7/range 2-12) and was equal postopera- tively and at 2 4 months (0.1 mm (± 0.8/range 1 to -2)). Preoperativ e ra dial inclination was 10°(± 7.2/range -6-22) and was equal postoperatively and at 24 months (± 18.5°(4/range 15-26)). Results according to the Dresd- ner score are presented in table 1. Secondary dislocation between the postoperative position and the 2 4-month control was not observed in any patient. All fractures were partially consolidated after six weeks and comple- tely consolidated after three months. One patient had evidence of osteoarthritic development on the 1- and 2-year radiograph. Illustrated case A 20-year-old male fell from about five meters onto his left upper extremity. Radiographic evaluation demon- strated an AO type-C3 multifragmentary dorsally tilted distal radius fracture (figure 3). He underwent surgery as described with a volar-radial double plate (figures 4 and 5). At two-year follow-up, he showed excellent out- come without p ain, with free function, but with slightly reduced mobility (flexion/extension 50/0/60° (60/0/70°)). Implant removal was not necessary. Discussion The presented double plating techniq ue, with the radial plate used as a buttress plate, is a very useful tool to reduce a displaced radial styloid fragment in the frontal plane, particularly in osteoporotic bone or if the styloid fracture is multifragmentary. In these cases, anatomic reduction without the support of the radial plate can be difficult. Secondary dislocation did not occur i n any of our patients. Biomechanical data for this fixation are not available, but it seems that sufficient stability was present to allow a functional rehabilitation protocol, even in osteoporotic fractures . The mechanical strength of this doub le-plating technique is mainly provided by the volar plate, whereas the radial plate acts as a but- tress plate holding the radial styloid fragments in place. Figure 3 Illustrate d case ( preoperative radiographs).Complex multifragmentary fracture of the distal radius with dorsal tilt. Figure 4 Illustrated case ( surgery).Intraoperativeimagewith partially detached pronator quadratus muscle over the volar plate. The radial plate is visible on the radial border of the radius. (the image has been flipped horizontally for better comparison with the X-ray). Figure 5 Illustrated case (postoperative radiographs).The fracture is anatomically reduced and stabilized. Jacobi et al . Journal of Orthopaedic Surgery and Research 2010, 5:55 http://www.josr-online.com/content/5/1/55 Page 4 of 6 In general, only 1-2 proximal screws were used on the radial plate for this purpose. In the pre sent study, flexion and extension fractures are included, but they are two separate entities. How- ever, the tendency for radial dislocation can be a com- mon factor in both fracture types, and the radial plate can be helpful in both types. Functional outcome for our study population reflect s what is reported in the literature for distal radius frac- tures (although less difficult fractures were involved in most reports) [3,6,10,21]. In the follow-up, the radial plate can cause some irritation to the first extensor compartment, which is why metal removal was done in five cases. In our series, standard plates were used as the radial plate. A specially designed radial buttress plate might reduce tendon irritation. In our country, the barrier to metal removal is low, and many patients request it due to minimal symptoms. However the pos- sibility of removal of the radial plate should be consid- ered before wound closure in selected cases with a sufficiently stabilized radial styloid process. This is favoured if the radial styloid process fragment is not a multifragmentary fracture or osteoporotic. The surgical approach is important. Most surgeons utilise the H enry approach to the volar side of the distal radius, entering between the flexor carpi radial is tendon and the radial artery [22]. This approach has been modi- fied by Orbay to include release of the distal osseous insertion of the brachioradialis tendon [4]. This permits better manipulation of the fracture fragments because the brachioradialis tendon is known to be an important deforming force in such injuries [23]. If visual control of the articular surface during reduc- tion is necessa ry, a single vo lar approach is contraindi- cated unless sufficient control of the articular surface can be provided by arthroscopy [24]. This can be the case in joint depression fractures, in fractures with com- pletely displaced joint fragments or in fractures of the dorsal rim. These fractures are therefore also i nap- propriate for the described technique. In the present study, polyaxial locking plates were exclusively used. The technique i s also suit able for uniaxial plates. This may be an advantage for stability, but is disadvantageous for optimal placement of screws. The present study had limitations. First, radiographic evaluations were done on standard X-rays, and only in 6 of 10 cases was an initial CT available. Se cond, the study population was relatively small because the num- ber of patients reflected only about 10% of t he radius fractures treated surgically at our hospital. Third, a fol- low-up period of two years is too short to draw defini- tive conclusions on osteoarthritic development. Conclusions The presented single-approach double plating technique with a radial buttress plate for multifragmentary distal radius fractures is useful because it facilitates anatomic repositioning and stable fixation. It is indicated only in a subgroup of patients with comminuted distal radius fractures in which displacement of the radial styloid process is difficult to manage. It leads to good clinical and radiological outcomes, as supported by our results. Authors’ contributions MJ designed the study, collected data, prepared the artwork, drafted the manuscript and performed the data analysis. PW participated in the design of the study, participated in data collection and drafting of the manuscript. GK participated in the design of the study and coordination and helped to draft the manuscript. All authors read and approved the final manuscript. Competing interests There was no personal or institutional financial support in relation to this study. Received: 25 October 2009 Accepted: 11 August 2010 Published: 11 August 2010 References 1. Kamano M, Honda Y, Kazuki K, Yasuda M: Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res 2002, 403-408. 2. Chung KC, Petruska EA: Treatment of unstable distal radial fractures with the volar locking plating system. Surgical technique. J Bone Joint Surg Am 2007, 89(Suppl 2 Pt 2):256-266. 3. Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM: Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 2006, 88:2687-2694. 4. Orbay JL, Fernandez DL: Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg [Am] 2004, 29:96-102. 5. Orbay JL, Touhami A: Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 2006, 445:58-67. 6. Zettl RP, Clauberg E, Nast-Kolb D, Ruchholtz S, Kuhne CA: [Volar locking compression plating versus dorsal plating for fractures of the distal radius: a prospective, randomized study]. Unfallchirurg 2009, 112:712-718. 7. Jakob M, Rikli DA, Regazzoni P: Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients. J Bone Joint Surg Br 2000, 82:340-344. 8. Westphal T, Piatek S, Schubert S, Winckler S: Outcome after surgery of distal radius fractures: no differences between external fixation and ORIF. Arch Orthop Trauma Surg 2005, 125:507-514. 9. Wright TW, Horodyski M, Smith DW: Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg [Am] 2005, 30:289-299. 10. Ruch DS, Papadonikolakis A: Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg [Am] 2006, 31:9-16. 11. Arora R, Lutz M, Fritz D, Zimmermann R, Oberladstatter J, Gabl M: Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures. Arch Orthop Trauma Surg 2005, 125:399-404. 12. Letsch R, Infanger M, Schmidt J, Kock HJ: Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position. Arch Orthop Trauma Surg 2003, 123:333-339. 13. Kapandji A: [Internal fixation by double intrafocal plate. Functional treatment of non articular fractures of the lower end of the radius (author’s transl)]. Ann Chir 1976, 30:903-908. 14. Willenegger H, Guggenbuhl A: [Operative treatment of certain cases of distal radius fracture.]. Helv Chir Acta 1959, 26:81-94. Jacobi et al . Journal of Orthopaedic Surgery and Research 2010, 5:55 http://www.josr-online.com/content/5/1/55 Page 5 of 6 15. Rikli DA, Regazzoni P: Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 1996, 78:588-592. 16. Rikli DA, Regazzoni P, Babst R: [Dorsal double plating for fractures of the distal radius–a biomechanical concept and clinical experience]. Zentralbl Chir 2003, 128:1003-1007. 17. Huskisson EC: Measurement of pain. J Rheumatol 1982, 9:768-769. 18. Gartland JJ Jr, Werley CW: Evaluation of healed Colles’ fractures. J Bone Joint Surg Am 1951, 33-A:895-907. 19. MacDermid JC, Turgeon T, Richards RS, Beadle M, Roth JH: Patient rating of wrist pain and disability: a reliable and valid measurement tool. J Orthop Trauma 1998, 12:577-586. 20. Schneiders W, Biewener A, Rammelt S, Rein S, Zwipp H, Amlang M: [Distal radius fracture. Correlation between radiological and functional results]. Unfallchirurg 2006, 109:837-844. 21. Rozental TD, Blazar PE: Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg [Am] 2006, 31:359-365. 22. Protopsaltis TS, Ruch DS: Volar approach to distal radius fractures. J Hand Surg Am 2008, 33:958-965. 23. Sarmiento A: The brachioradialis as a deforming force in Colles’ fractures. Clin Orthop Relat Res 1965, 38:86-92. 24. Varitimidis SE, Basdekis GK, Dailiana ZH, Hantes ME, Bargiotas K, Malizos K: Treatment of intra-articular fractures of the distal radius: fluoroscopic or arthroscopic reduction? J Bone Joint Surg Br 2008, 90:778-785. doi:10.1186/1749-799X-5-55 Cite this article as: Jacobi et al.: Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique. Journal of Orthopaedic Surgery and Research 2010 5:55. Submit your next manuscript to BioMed Central and take full advantage of: • Convenient online submission • Thorough peer review • No space constraints or color figure charges • Immediate publication on acceptance • Inclusion in PubMed, CAS, Scopus and Google Scholar • Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit Jacobi et al . Journal of Orthopaedic Surgery and Research 2010, 5:55 http://www.josr-online.com/content/5/1/55 Page 6 of 6 . this article as: Jacobi et al.: Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating. RESEA R C H ART I C L E Open Access Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating. strongly facilitates anatomic reduction and stable fixation of intra-articular distal radius fractures with dislocation of the radial styloid process and leads to satisfactory clinical and radiographic outcome. Background During

Ngày đăng: 20/06/2014, 04:20

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN