Tổng quan về tổng đài điện thoại panasonic

246 495 0
Tổng quan về tổng đài điện thoại panasonic

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Advanced Hybrid System Installation Manual MODEL This manual was printed with soy based ink KX-TA308 KX-TA616 Please read this manual before connecting the Advanced Hybrid System System Highlights System Capacity Basic System Expansion Extensions Outside (CO) lines Maximum extensions 24 Maximum outside (CO) lines 16 24 Special System Points System Expansion Direct Backup Power Supply This system can expand the outside (CO) lines (KX-TA308 only) and extension capacity by installing an optional card  2– 24 Car batteries can be connected directly to this system as a backup power supply in the event of a power failure This system does not need an optional battery adaptor  2– 23 Hybrid This system can accept Panasonic analog proprietary telephones Also, single line devices such as single line telephones, facsimiles and data terminals can be connected Calling from the outside (Direct Inward System Access) External callers can call extensions in the system If you install an optional card, an outgoing message will greet the caller and give information about how to access an extension  3– 13 Precautions • Keep the unit away from heating appliances and electrical noise generating devices such as fluorescent lamps, motors and televisions These noise sources can interfere with the performance of the Advanced Hybrid System • This unit should be kept free of dust, moisture, high temperature (more than 40˚C) and vibration, and should not be exposed to direct sunlight • Never attempt to insert wires, pins, etc into the vents or other holes of this unit • If there is any trouble, disconnect the unit from the telephone line Plug the telephone directly into the telephone line If the telephone operates properly, not reconnect the unit to the line until the trouble has been repaired If the telephone does not operate properly, chances are that the trouble is in the telephone system, and not in the unit • Do not use benzine, thinner, or the like, or any abrasive powder to clean the cabinet Wipe it with a soft cloth WARNING THIS UNIT MAY ONLY BE INSTALLED AND SERVED BY QUALIFIED SERVICE PERSONNEL WHEN A FAILURE OCCURS WHICH RESULTS IN THE INTERNAL PARTS BECOMING ACCESSIBLE, DISCONNECT THE POWER SUPPLY CORD IMMEDIATELY AND RETURN THIS UNIT TO YOUR DEALER DISCONNECT THE TELECOM CONNECTION BEFORE DISCONNECTING THE POWER CONNECTION PRIOR TO RELOCATING THE EQUIPMENT, AND RECONNECT THE POWER FIRST THIS UNIT IS EQUIPPED WITH AN EARTHING CONTACT PLUG FOR SAFETY REASONS THIS PLUG MUST ONLY BE CONNECTED TO AN EARTHING CONTACT SOCKET WHICH HAS BEEN INSTALLED ACCORDING TO REGULATIONS THE POWER SUPPLY CORD IS USED AS THE MAIN DISCONNECT DEVICE, ENSURE THAT THE SOCKET-OUTLET IS LOCATED/INSTALLED NEAR THE EQUIPMENT AND IS EASILY ACCESSIBLE TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE Precautions For your future reference SERIAL NO DATE OF PURCHASE (found on the bottom of the unit) NAME OF DEALER DEALER’S ADDRESS Note • This Installation Manual does not show complete model number that indicate the country where your models should be used The model number of your unit is found on the label affixed to the unit MODEL NO – – – – – – – – (label) Introduction Structure of the Manual This manual consists of the following sections: Section Basic System Construction Provides general information on the system including connection diagrams Section Installation Contains the system installation and wiring instructions, as well as how to install the optional card Section Features Describes the optional and programmable features in alphabetical order It also provides information about the conditions, required System Programming, connection references, related features and operating instructions references for every feature Section System Programming Describes the steps required to assign features to extensions or to the system Section Appendix Provides specifications and the default values of the System Programming Section Troubleshooting Provides information for system and telephone troubleshooting Section Programming Tables Provides programming tables for user-programmed data Description of the Symbols Mainly Used in this manual !  Additional information and conditions The feature or program references Contents Section Basic System Construction Section Installation 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 Section 2-2 2-4 2-4 2-5 2-6 2-6 2-7 2-9 2-10 2-11 2-12 2-13 2-14 2-17 2-17 2-19 2-23 2-24 2-29 2-29 2-30 2-31 2-33 2-34 Features A B C Before Installation Unpacking Names and Locations Wall Mounting Frame Ground Connection Opening the Top Front Cover Outside (CO) Line Connection Extension Connection External Pager (Paging Equipment) Connection External Music Connection Paralleled Telephone Connection Polarity Sensitive Telephone Connection Printer and PC Connection Location of Optional Cards OGM/FAX Detection Card Installation Doorphone and Door Opener Connection Backup Batteries Connection Installing a 3-CO Line & Ext Expansion Card (KX-TA30877) and SLT Extn Expansion Card (KX-TA30874) Auxiliary Connection for Power Failure Transfer Securing the Cords Closing the Front Cover Starting the System for the First Time System Restart System Data Clear Absent Message Capability Account Code Entry Alternate Calling – Ring/Voice (Voice to Ring only) Automatic Callback Busy (Camp-On) Automatic Outside (CO) Line Access Number Busy Station Signaling (BSS) Call Forwarding Calling Party Control (CPC) Signal Detection Call Park Call Pickup Call Splitting Call Transfer – to Extension Call Transfer – to Outside (CO) Line Call Waiting 3-2 3-2 3-3 3-3 3-4 3-4 3-5 3-5 3-6 3-7 3-7 3-8 3-8 3-9 Contents C D E F H I L M O Conference (3-Party) Conference (5-Party) Data Line Security Date and Time Setting Direct In Line (DIL) Direct Inward System Access (DISA) Display Contrast Adjustment (KX-T7330/KX-T7030/KX-T7130/KX-T7033 only) Distinctive Dial Tone Do Not Disturb (DND) Door Opener Doorphone Call DSS Console Emergency Call Executive Busy Override Extension Button Confirmation (KX-T7330/KX-T7030/KX-T7130/KX-T7033 only) Extension Group Extension Password / System Password External Feature Access Flash Flexible Buttons Handset/Headset Selection (KX-T7330/KX-T7030/KX-T7130/KX-T7033 only) Handsfree Answerback Handsfree Operation Hold Hookswitch Flash Host PBX Access Intercept Routing Intercom Calling Language Selection Limited Call Duration Line Access Buttons Log-In/Log-Out Message Waiting Microphone Mute Music on Hold / Background Music (BGM) One-Touch Dialing Operator / Manager Extension Operator Call Outgoing Message (OGM) Outside Calling Outside (CO) Line Ringing Selection 3-10 3-11 3-11 3-12 3-12 3-13 3-20 3-20 3-21 3-21 3-22 3-23 3-23 3-24 3-24 3-25 3-25 3-26 3-26 3-27 3-28 3-28 3-28 3-29 3-30 3-30 3-31 3-31 3-32 3-32 3-33 3-34 3-34 3-35 3-35 3-35 3-36 3-36 3-37 3-40 3-41 Contents P R S T U V W Section 4.1 4.2 Paging Paralleled Telephone Connection Personal Speed Dialing Pickup Dialing Polarity Reverse Detection Power Failure Transfer Preferred Line Assignment — Incoming Preferred Line Assignment — Outgoing Proprietary Telephone setting Data Default Set Pulse to Tone Conversion Receiving Calls Redial Ringing Pattern Selection Room Monitor Secret Dialing Self-Extension Number Confirmation (KX-T7330/KX-T7030/KX-T7130/KX-T7033 only) Station Feature Clear Station Hunting Station Lock Station Message Detail Recording (SMDR) System Data Default Set System Speed Dialing Timed Reminder Time (Day/Night/Lunch) Service Toll Restriction Toll Restriction for System Speed Dialing Toll Restriction Override by Extension Password Toll Restriction – Station Lock Boundary Class Uniform Call Distribution (UCD) Voice Mail Integration Volume Control Walking COS 3-41 3-42 3-42 3-43 3-43 3-44 3-44 3-45 3-45 3-46 3-46 3-46 3-47 3-48 3-48 3-49 3-49 3-50 3-51 3-52 3-53 3-54 3-54 3-55 3-56 3-58 3-59 3-60 3-60 3-64 3-67 3-67 System Programming Before System Programming System Programming [000] Date and Time Setting [001] System Speed Dialing Entry [002] System Password [003] DSS Console Port Assignment [004] Paired Telephone Assignment for DSS Console [005] One-Touch Transfer Using a DSS Button [006] Time (Day/Night/Lunch) Service Changing Mode 4-2 4-5 4-5 4-5 4-6 4-7 4-7 4-8 4-8 Contents [007] [008] [009] [010] [100] [101] [102] [103] [104] [105] [106] [107] [108] [109] [110] [111] [112] [113] [114] [115] [116] [117] [118] [119] [120] [121] [122] [123] [124] [125] [200] [201] [202] [203] [204] [205] [206] [207] [208] [210] [211] [212] [213] [300] Time (Day/Night/Lunch) Service Start Time Operator Assignment Extension Number Assignment LCD Time Display Selection Hunting Group Set Hunting Type Voice Mail Port DTMF Integration Hold Mode Selection Conference Tone External Paging Access Tone DTMF Receiver Check Flash Mode for a Station Locked Extension CO Indicator Assignment Flash Key Mode Hold Music Selection DSS Console Indication Mode Automatic Redial Repeat Automatic Redial Interval Time Extension Ringing Pattern Selection Conference Pattern Selection Call Pickup Tone Pulse Restriction Redialing after Pulse to Tone Conversion Bell Frequency Automatic Outside (CO) Line Access Number Selection Automatic Rotation for Outside (CO) Line Access Break Ratio SLT Ringing Mode Selection Toll Restriction Check for and # Hold Recall Time Transfer Recall Time Call Forwarding Start Time Pickup Dial Delay Time Call Duration Count Start Time Outside-to-Outside (CO-to-CO) Line Duration Time Limit Dialing Start Time Hookswitch Flash Timing Range Selection Interdigit Time DTMF Time No Dial Disconnection Outside (CO) Line Duration Time Limit Bell Off Detection Carrier Code Assignment 4-9 4-10 4-10 4-11 4-12 4-12 4-13 4-13 4-15 4-15 4-16 4-16 4-16 4-17 4-17 4-18 4-18 4-19 4-19 4-20 4-20 4-21 4-21 4-21 4-22 4-22 4-22 4-23 4-23 4-23 4-24 4-24 4-24 4-25 4-25 4-26 4-26 4-27 4-27 4-28 4-28 4-29 4-29 4-30 Contents [301] Toll Restriction — System Speed Dialing Boundary Class [302]–[305] Toll Restriction — Classes through Denied Codes [306] Toll Restriction — Exception Codes [309] Emergency Dial Number Set [310] Account Codes [311] Automatic Pause Insertion Codes [312] Toll Restriction — Station Lock Boundary Class [400] Outside (CO) Line Connection Assignment [401] Dial Mode [402] Pulse Speed Selection [403] Host PBX Access Codes [404] Outside (CO) Line Group Assignment [405]–[407] Flexible Outward Dialing Assignment — Day/Night/Lunch [408]–[410] Flexible Ringing Assignment — Day/Night/Lunch [411]–[413] Delayed Ringing Assignment — Day/Night/Lunch [414]–[416] Outside (CO) Line Mode — Day/Night/Lunch [417] Pause Time [418] Flash Time [419] Automatic Designated Outside (CO) Line Access [420] Calling Party Control (CPC) Signal [421] CPC Detection for Outgoing Calls [422] Disconnect Time [423] Outside (CO) Line Ringing Pattern Selection [424] Reverse (Polarity) Circuit Assignment [500] DISA Incoming Dialing Mode Selection [501] DISA Built-in Auto Attendant [502] OGM Mode Selection [503] FAX Connection [504] DISA Delayed Answer Time [505] DISA Waiting Time after OGM [506] DISA Busy Mode [507] DISA Intercept Mode [508] DISA Ringing Time before Intercept [509] DISA Ringing Time after Intercept [510] DISA No Dial Mode [511] DISA Security Type [512] DISA Security Codes [513] Cyclic Tone Detection [514] Fax Tone Detection [515] Intercept Time for Internal DISA [516] DISA Incoming Assignment [517] DISA AA Wait Time [518] DISA Tone Selection after the Security Code 10 4-30 4-31 4-32 4-32 4-33 4-33 4-34 4-35 4-35 4-36 4-36 4-37 4-38 4-39 4-40 4-41 4-42 4-43 4-43 4-44 4-45 4-45 4-46 4-47 4-48 4-49 4-50 4-51 4-51 4-51 4-52 4-52 4-53 4-53 4-54 4-54 4-55 4-55 4-56 4-56 4-57 4-57 4-58 Programming Tables [414] Outside (CO) Line Mode — Day Outside line no Default: All * [415] Outside (CO) Line Mode [416] Outside (CO) Line Mode — Night — Lunch …24), D1: DISA1, D2: DISA2, U: UCD Selection — N: Normal, DIL + Extension jack no (01 N DIL Extn no D1 D2  U N DIL Extn no D1 D2  [417] Pause Time Outside line no Default: All * 1.5  Selection (seconds) 2.5 3.5 4.5 U 80 100 Selection (milliseconds) 160 300 600  Default: All * 7-20 [420] Calling Party Control (CPC) Signal Selection Selection: 00 (Disable), 06 (62 msec)…75 (614 msec) 42 (350 milliseconds) Enable  Programming Tables Disable U [418] Flash Time [419] Automatic Designated Outside (CO) Line Access Outside line no N DIL Extn no D1 D2  900 1200 [421] CPC Detection for Outgoing Calls Selection Enable Disable  Programming Tables [422] Disconnect Time Outside line no Default: All * 0.5 [423] Outside (CO) Line Ringing Pattern Selection Selection (seconds) 1.5 4.0  [424] Reverse (Polarity) Circuit Assignment Selection Double Selection Enable Disable  Single  Triple [500] DISA Incoming Dialing Mode Selection Selection Default Change Without AA  With AA [501] DISA Built-in Auto Attendant Auto attendant no Default Selection Jack: Extension jack no (01…24) GRP: Extension group no (1…8) All: Not stored Programming Tables 7-21 Programming Tables [502] OGM MODE Selection Selection Default Change MODE  MODE MODE MODE MODE Disable (Not assigned) [504] DISA Delayed Answer Time Selection Default Change sec sec  sec [506] DISA Busy Mode Selection Default Change [503] FAX Connection Extension jack no (01…24) / Disable [505] DISA Waiting Time after OGM 12 sec sec [507] DISA Intercept Mode 10 sec 15 sec [508] DISA Ringing Time before Intercept Disconnect Call Waiting DISA Intercept Disconnect 10 sec 20 sec 30 sec 40 sec 60 sec 120 sec    [509] DISA Ringing Time after Intercept Selection  [511] DISA Security Type Selection Default Trunk  All DISA Intercept Disconnect  [512] DISA Security Codes 0…9, digit None All codes = 0000 DISA Intercept Disconnect  [513] Cyclic Tone Detection Disable Times Times Times  CODE=01 CODE=02 CODE=03 CODE=04 Change [514] FAX Tone Detection Selection Default Change [510] DISA No Dial Mode 10 sec 20 sec 30 sec 40 sec 60 sec 120 sec Default Change 7-22 sec  Time  Times Programming Tables [515] Intercept Time for Internal DISA sec  sec sec [517] DISA AA Wait Time sec sec  sec sec sec Programming Tables [516] DISA Incoming Assignment Extension jack no Default: All 01 02 03 04 05 06 07 08 09 10 11 12 Selection Enable  [518] DISA Tone Selection after the Security Code Selection Default Change Selection Default Change Enable  Disable [521] UCD Busy Waiting Time 01…32 minutes sec sec  Disable sec [520] UCD Group sec Extension group no (1…8) [522] UCD OGM Message Interval Time 30 sec 10 minutes Intercept  Enable [519] DISA OGM Mute Time  [524] UCD Intercept Mode Selection Default Change Selection Extension jack no 13 14 15 16 17 18 19 20 21 22 23 24 Disable Disconnect 1.5 min [523] UCD Busy Mode Intercept  Disconnect [525] UCD Ringing Time before Intercept 10 sec 20 sec  30 sec 40 sec 60 sec 120 sec [526] UCD Ringing Time after Intercept Selection Default Change 10 sec 20 sec  30 sec 40 sec 60 sec 120 sec Programming Tables 7-23 Programming Tables Extension jack no Default: All 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 * 7-24 [601] TRS – Class of Service Assignment — Day COS no (1…5) [602] TRS – Class of Service Assignment — Night COS no (1…5) [603] TRS – Class of Service Assignment — Lunch COS no (1…5)    Programming Tables 5 Programming Tables [605] Account Code Entry Mode Extension jack no Default: All 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 * Option  Selection Forced Verify-All [606] Call Transfer to an Outside (CO) Line Verify-Toll [607] Call Forwarding to an Outside (CO) Line Selection Enable Disable  Selection Enable Disable  Programming Tables 7-25 Programming Tables [608] Executive Busy Override Extension jack no Default: All 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 * 7-26 [609] Do not Disturb Override [610] Paralleled Telephone Connection [611] TAM Extension Selection Enable Disable  Selection Enable Disable  Selection Enable Disable  Selection Enable Disable  Programming Tables Programming Tables [612] Room Monitor Assignment Extension jack no Default: All 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 * [613] Outside (CO) Line Duration Time Limit Selection [614] Internal Pulse Detection [615] LCD Language Assignment Selection Enable Disable  Selection Enable Disable  Selection Enable Disable  Selection English Spanish Portuguese Russian  Programming Tables 7-27 Programming Tables [700] Doorphone Ringing Assignment — Day Extension jack no Default: All 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 * 7-28 E  D E  D E  Programming Tables D [701] Doorphone Ringing Assignment — Night [702] Doorphone Ringing Assignment — Lunch 1…4: Doorphone no., E: Enable / D: Disable 4 E D E D E D E D E D E D       E  D E  D E  D Programming Tables [703] Door Opener Assignment — Day Extension jack no E Default: All 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 * D  E D  E D  [704] Door Opener Assignment — Night [705] Door Opener Assignment — Lunch 1…4: Door opener no., E: Enable / D: Disable 4 E D E D E D E D E D E D       E D  E D  E D  [706] Doorphone Ringing / Tone Pattern Selection Doorphone no Default: All * Single [707] Doorphone Access Tone Selection [708] Doorphone Ringing Time Selection Double Triple  Selection Enable Disable  Selection 15 sec 30 sec  S-Double Programming Tables 7-29 Programming Tables [709] Door Opener Time Door opener no Default: All * sec sec sec Selection sec sec  sec sec sec [800] SMDR RS-232C Communication Parameters New line code Selection Default Change Word length Baud rate CR+LF CR 150  300 600 1200 2400 4800 9600  [801] SMDR Parameter Default Page length (4…99) Selection Incoming calls Outgoing calls [803] Secret Speed Dialing / One-Touch Dialing Printing Selection Default Change 7-30 No Printing  Programming Tables Mark Space Even Odd None    [802] Incoming/Outgoing Call Selection for Printing 66 Skip perforation (0…95) Stop bit Parity bit Printing On Off On Off Toll Default  Selection  [805] SMDR Account Code Selection CODE  INDEX Memo Memo 169 mm Install a screw here Install a screw here 92.5 mm 236 mm TEMPLATE FOR THE WALL MOUNTING Copy this template and place it on the wall Install a screw here Install the screws If you mount the unit on a concrete or mortar wall, place the anchor plugs flush to the wall with a hammer beforehand Hook the unit on the screw heads ƒ Please see 2.4, “Wall Mounting” 118 mm 185 mm NOTE You can identify the data of manufacturing by serial number which is marked on the right side of the main unit Serial number : X X XXXXXXXXX First digit : year (last digit of the year in number) 8-1998, 9-1999, 0-2000 Second digit : month (in alphabetical) A-January, B-February, L-December Matsushita Electric Industrial Co., Ltd Central P O Box 288, Osaka 530-91, Japan Printed in Japan PSQX1574ZA KF0898CM0 ... Panasonic Cordless Phone (one pair) KX-T7050 (two pair) KX-T7055 (two pair) Panasonic Telephone Answering Machine with Facsimile Panasonic (one pair) KX-T7320 KX-T7330 (two pair) (two pair) Panasonic. .. Panasonic Cordless Phone (one pair) KX-T7050 (two pair) KX-T7055 (two pair) Panasonic Telephone Answering Machine with Facsimile Panasonic (one pair) KX-T7320 KX-T7330 (two pair) (two pair) Panasonic. .. Yellow Red Black Green Panasonic Panasonic Doorphone (KX-T30865) Doorphone (KX-T30865) 4-conductor wiring is required Yellow Red Panasonic Doorphone (KX-T30865) Black Green Panasonic Doorphone (KX-T30865)

Ngày đăng: 19/06/2014, 22:17

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan