Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001 Nzs 3101 06 pt sl 001

Software Verification PROGRAM NAME: REVISION NO.: SAFE EXAMPLE NZS 3101-06 PT-SL-001 Post-Tensioned Slab Design PROBLEM DESCRIPTION The purpose of this example is to verify the slab stresses and the required area of mild steel strength reinforcing for a post-tensioned slab A one-way simply supported slab is modeled in SAFE The modeled slab is 254 mm thick by 915 mm wide and spans 9754 mm as, shown in shown in Figure Prestressing tendon, Ap Mild Steel, As 229 mm 254 mm 25 mm Length, L = 9754 mm 914 mm Section Elevation Figure One-Way Slab EXAMPLE NZS 3101-06 PT-SL-001 - Software Verification PROGRAM NAME: REVISION NO.: SAFE A 254 mm wide design strip is centered along the length of the slab and has been defined as an A-Strip B-strips have been placed at each end of the span, perpendicular to Strip-A (the B-Strips are necessary to define the tendon profile) A tendon with two strands, each having an area of 99 mm2, has been added to the A-Strip The self weight and live loads have been added to the slab The loads and post-tensioning forces are as follows: Loads: Live = 4.788 kN/m2 Dead = self weight, The total factored strip moments, required area of mild steel reinforcement, and slab stresses are reported at the midspan of the slab Independent hand calculations were compared with the SAFE results and summarized for verification and validation of the SAFE results GEOMETRY, PROPERTIES AND LOADING Thickness Effective depth Clear span T, h = d = L = Concrete strength Yield strength of steel Prestressing, ultimate Prestressing, effective Area of Prestress (single strand) Concrete unit weight Modulus of elasticity Modulus of elasticity Poisson’s ratio f 'c fy fpu fe Ap wc Ec Es ν = = = = = = = = = Dead load Live load wd wl = = 254 mm 229 mm 9754 mm 30 400 1862 1210 198 23.56 25000 200,000 MPa MPa MPa MPa mm2 kN/m3 N/mm3 N/mm3 self kN/m2 4.788 kN/m2 TECHNICAL FEATURES OF SAFE TESTED ¾ Calculation of the required flexural reinforcement ¾ Check of slab stresses due to the application of dead, live, and post-tensioning loads RESULTS COMPARISON Table shows the comparison of the SAFE total factored moments, required mild steel reinforcing, and slab stresses with the independent hand calculations EXAMPLE NZS 3101-06 PT-SL-001 - Software Verification PROGRAM NAME: REVISION NO.: SAFE Table Comparison of Results FEATURE TESTED INDEPENDENT RESULTS SAFE RESULTS DIFFERENCE 156.12 156.14 0.01% 14.96 15.07 0.74% −5.058 −5.057 0.02% 2.839 2.839 0.00% −10.460 −10.465 0.05% 8.402 8.407 0.06% −7.817 −7.817 0.00% 5.759 5.759 0.00% Factored moment, Mu (Ultimate) (kN-m) Area of Mild Steel req’d, As (sq-cm) Transfer Conc Stress, top (D+PTI), MPa Transfer Conc Stress, bot (D+PTI), MPa Normal Conc Stress, top (D+L+PTF), MPa Normal Conc Stress, bot (D+L+PTF), MPa Long-Term Conc Stress, top (D+0.5L+PTF(L)), MPa Long-Term Conc Stress, bot (D+0.5L+PTF(L)), MPa COMPUTER FILE: NZS 3101-06 PT-SL-001.FDB CONCLUSION The SAFE results show a very close comparison with the independent results EXAMPLE NZS 3101-06 PT-SL-001 - Software Verification PROGRAM NAME: REVISION NO.: SAFE HAND CALCULATIONS: Design Parameters: Mild Steel Reinforcing f’c = 30MPa fy = 400MPa φb = 0.85 α1 = 0.85 for f ′c ≤ 55 MPa β1 = 0.85 for f ′c ≤ 30, cb = εc ε c + f y Es Post-Tensioning fpu = 1862 MPa fpy = 1675 MPa Stressing Loss = 186 MPa Long-Term Loss = 94 MPa fi = 1490 MPa fe = 1210 MPa d = 214.7 amax = 0.75β1cb= 136.8 mm Prestressing tendon, Ap Mild Steel, As 229 mm 254 mm 25 mm Length, L = 9754 mm Elevation 914 mm Section Loads: Dead, self-wt = 0.254 m x 23.56 kN/m3 = 5.984 kN/m2 (D) x 1.2 = 7.181kN/m2 (Du) Live, = 4.788 kN/m2 (L) x 1.5 = 7.182 kN/m2 (Lu) Total = 10.772 kN/m2 (D+L) = 14.363 kN/m2 (D+L)ult ω =10.772 kN/m2 x 0.914 m = 9.846 kN/m, ωu = 14.363 kN/m2 x 0.914 m = 13.128 kN/m Ultimate Moment, M U = EXAMPLE NZS 3101-06 PT-SL-001 - wl12 = 13.128 x (9.754)2/8 = 156.12 kN-m Software Verification PROGRAM NAME: REVISION NO.: Ultimate Stress in strand, f PS = f SE + 70 + SAFE f'c 300 ρ P 30 300(0.00095) = 1385 MPa ≤ f SE + 200 = 1410 MPa = 1210 + 70 + Ultimate force in PT, Fult , PT = AP ( f PS ) = 2(99)(1385) /1000 = 274.23 kN Stress block depth, a = d − d − 2M * α f 'c φ b = 0.229 − 0.2292 − 2(156.12) (1e3) = 37.48 mm 0.85(30000)(0.85)(0.914) Ultimate moment due to PT, a 37.48 M ult , PT = Fult , PT ( d − )φ = 274.23(229 − )(0.85) /1000 = 49.01 kN-m 2 Net ultimate moment, M net = M U − M ult , PT = 156.1 − 49.10 = 107.0 kN-m Required area of mild steel reinforcing, M net 107.0 = (1e6) = 1496 mm AS = a 0.03748 ⎞ ⎛ φ f y (d − ) 0.85(400000) ⎜ 0.229 − ⎟ 2 ⎝ ⎠ Check of Concrete Stresses at Midspan: Initial Condition (Transfer), load combination (D+PTi) = 1.0D+0.0L+1.0PTI Tendon stress at transfer = jacking stress − stressing losses =1490 − 186 = 1304 MPa The force in the tendon at transfer, = 1304(197.4) /1000 = 257.4 kN Moment due to dead load, M D = 5.984(0.914)(9.754) / = 65.04 kN-m Moment due to PT, M PT = FPTI (sag) = 257.4(102 mm) /1000 = 26.25 kN-m F M − M PT −257.4 65.04 − 26.23 f = PTI ± D Stress in concrete, = ± A S 0.254(0.914) 0.00983 where S=0.00983m3 f = −1.109 ± 3.948MPa f = −5.058(Comp) max, 2.839(Tension) max EXAMPLE NZS 3101-06 PT-SL-001 - Software Verification PROGRAM NAME: REVISION NO.: SAFE Normal Condition, load combinations: (D+L+PTF) = 1.0D+1.0L+1.0PTF Tendon stress at normal = jacking − stressing − long-term = 1490 − 186 − 94 = 1210 MPa The force in tendon at normal, = 1210(197.4) /1000 = 238.9 kN Moment due to dead load, M D = 5.984(0.914)(9.754) / = 65.04 kN-m Moment due to live load, M L = 4.788(0.914)(9.754) / = 52.04 kN-m Moment due to PT, M PT = FPTI (sag) = 238.9(102 mm) /1000 = 24.37 kN-m Stress in concrete for (D+L+PTF), F M − M PT −238.8 117.08 − 24.37 f = PTI ± D + L = ± A S 0.254(0.914) 0.00983 f = −1.029 ± 9.431 f = −10.460(Comp) max, 8.402(Tension) max Long-Term Condition, load combinations: (D+0.5L+PTF(L)) = 1.0D+0.5L+1.0PTF Tendon stress at normal = jacking − stressing − long-term = 1490 − 186 − 94 = 1210 MPa The force in tendon at normal, = 1210(197.4) /1000 = 238.9 kN Moment due to dead load, M D = 5.984(0.914)(9.754) / = 65.04 kN-m Moment due to live load, M L = 4.788(0.914)(9.754) / = 52.04 kN-m Moment due to PT, M PT = FPTI (sag) = 238.9(102 mm) /1000 = 24.37 kN-m Stress in concrete for (D+0.5L+PTF(L)), M − M PT F −238.9 91.06 − 24.33 f = PTI ± D + 0.5 L = ± A S 0.254(0.914) 0.00983 f = −1.029 ± 6.788 f = −7.817(Comp) max, 5.759(Tension) max EXAMPLE NZS 3101-06 PT-SL-001 -

Ngày đăng: 18/09/2023, 20:43

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN