1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Iec 61076 3 112 2006

80 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

NORME INTERNATIONALE INTERNATIONAL STANDARD CEI IEC 61076-3-112 Première édition First edition 2006-04 Partie 3-112: Connecteurs rectangulaires – Spécification particulière pour connecteurs rectangulaires quatre contacts pour bus série haute performance utilisés dans les équipements audio/vidéo grand public Connectors for electronic equipment – Part 3-112: Rectangular connectors – Detail specification for rectangular connectors with four contacts for high performance serial bus for consumer audio/video equipment Numéro de référence Reference number CEI/IEC 61076-3-112:2006 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Connecteurs pour équipements électroniques – Publication numbering Depuis le 1er janvier 1997, les publications de la CEI sont numérotées partir de 60000 Ainsi, la CEI 34-1 devient la CEI 60034-1 As from January 1997 all IEC publications are issued with a designation in the 60000 series For example, IEC 34-1 is now referred to as IEC 60034-1 Editions consolidées Consolidated editions Les versions consolidées de certaines publications de la CEI incorporant les amendements sont disponibles Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent respectivement la publication de base, la publication de base incorporant l’amendement 1, et la publication de base incorporant les amendements et The IEC is now publishing consolidated versions of its publications For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorporating amendment and the base publication incorporating amendments and Informations supplémentaires sur les publications de la CEI Further information on IEC publications Le contenu technique des publications de la CEI est constamment revu par la CEI afin qu'il reflète l'état actuel de la technique Des renseignements relatifs cette publication, y compris sa validité, sont disponibles dans le Catalogue des publications de la CEI (voir ci-dessous) en plus des nouvelles éditions, amendements et corrigenda Des informations sur les sujets l’étude et l’avancement des travaux entrepris par le comité d’études qui a élaboré cette publication, ainsi que la liste des publications parues, sont également disponibles par l’intermédiaire de: The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology Information relating to this publication, including its validity, is available in the IEC Catalogue of publications (see below) in addition to new editions, amendments and corrigenda Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as the list of publications issued, is also available from the following: • Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch) • Catalogue des publications de la CEI • Catalogue of IEC publications Le catalogue en ligne sur le site web de la CEI (www.iec.ch/searchpub) vous permet de faire des recherches en utilisant de nombreux critères, comprenant des recherches textuelles, par comité d’études ou date de publication Des informations en ligne sont également disponibles sur les nouvelles publications, les publications remplacées ou retirées, ainsi que sur les corrigenda • IEC Just Published The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to search by a variety of criteria including text searches, technical committees and date of publication Online information is also available on recently issued publications, withdrawn and replaced publications, as well as corrigenda • Ce résumé des dernières publications parues (www.iec.ch/online_news/justpub) est aussi disponible par courrier électronique Veuillez prendre contact avec le Service client (voir ci-dessous) pour plus d’informations • Service clients IEC Just Published This summary of recently issued publications (www.iec.ch/online_news/justpub) is also available by email Please contact the Customer Service Centre (see below) for further information • Customer Service Centre Si vous avez des questions au sujet de cette publication ou avez besoin de renseignements supplémentaires, prenez contact avec le Service clients: If you have any questions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserv@iec.ch Tél: +41 22 919 02 11 Fax: +41 22 919 03 00 Email: custserv@iec.ch Tel: +41 22 919 02 11 Fax: +41 22 919 03 00 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Numérotation des publications NORME INTERNATIONALE INTERNATIONAL STANDARD CEI IEC 61076-3-112 Première édition First edition 2006-04 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Connecteurs pour équipements électroniques – Partie 3-112: Connecteurs rectangulaires – Spécification particulière pour connecteurs rectangulaires quatre contacts pour bus série haute performance utilisés dans les équipements audio/vidéo grand public Connectors for electronic equipment – Part 3-112: Rectangular connectors – Detail specification for rectangular connectors with four contacts for high performance serial bus for consumer audio/video equipment  IEC 2006 Droits de reproduction réservés  Copyright - all rights reserved Aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch Com mission Electrotechnique Internationale International Electrotechnical Com m ission Международная Электротехническая Комиссия CODE PRIX PRICE CODE W Pour prix, voir catalogue en vigueur For price, see current catalogue –2– 61076-3-112  CEI:2006 SOMMAIRE AVANT-PROPOS Informations générales 10 1.1 Domaine d’application 10 1.2 Méthode recommandée pour le montage 10 1.3 Valeurs nominales et caractéristiques 10 1.4 Références normatives 12 1.5 Marquage 12 1.6 Désignation de type CEI 14 1.7 Informations relatives aux commandes 14 Données techniques 14 2.1 Définitions 14 2.2 Description des modèles de connecteurs (voir Tableau 1) 16 2.3 Informations concernant l’application 16 2.4 Arrangements des contacts 18 Informations relatives aux dimensions 18 3.1 Généralités 18 3.2 Vue isométrique (voir Figure 3) 20 3.3 Informations concernant l'insertion (l'accouplement) 20 3.4 Embases (voir Figures et 10) 30 3.5 Fiches (voir Figures 11 et 12) 32 3.6 Accessoires 34 3.7 Informations concernant le montage des embases 34 3.8 Calibres 36 Caractéristiques 36 4.1 Catégorie climatique (voir Tableau 4) 36 4.2 Caractéristiques électriques 36 4.3 Caractéristiques mécaniques 38 Programme d’essais 40 5.1 Généralités 40 5.2 Programmes d’essais 44 Procédures d’assurance de la qualité 58 Annexe A (normative) Essai de flexion de câble 60 Annexe B (normative) Impédance de signal 62 Annexe C (normative) Diaphonie 66 Figure – Fiche 18 Figure – Embase 18 Figure – Vue isométrique 20 Figure – Fiche 22 Figure – Détails concernant la fiche 24 Figure – Embase 26 Figure – Section A-A de l'embase 26 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 61076-3-112  IEC:2006 –3– CONTENTS FOREWORD General information 11 1.1 Scope 11 1.2 Recommended method of mounting 11 1.3 Ratings and characteristics 11 1.4 Normative references 13 1.5 Marking 13 1.6 IEC type designation 15 1.7 Ordering information 15 Technical information 15 2.1 Definitions 15 2.2 Survey of connector styles (see Table 1) 17 2.3 Information on application 17 2.4 Contact arrangements 19 Dimensional information 19 3.1 General 19 3.2 Isometric view (see Figure 3) 21 3.3 Engagement (mating) information 21 3.4 Fixed connectors (see Figures and 10) 31 3.5 Free connectors (see Figures 11 and 12) 33 3.6 Accessories 35 3.7 Mounting information for fixed connectors 35 3.8 Gauges 37 Characteristics 37 4.1 4.2 4.3 Test 5.1 General 41 5.2 Test schedules 45 Quality assessment procedures 59 Climatic category (see Table 4) 37 Electrical characteristics 37 Mechanical characteristics 39 schedule 41 Annex A (normative) Cable flexing test 61 Annex B (normative) Signal impedance 63 Annex C (normative) Crosstalk 67 Figure – Free connector 19 Figure – Fixed connector 19 Figure – Isometric view 21 Figure – Free connector 23 Figure – Free connector section details 25 Figure – Fixed connector 27 Figure – Fixed connector cross section A-A 27 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU –4– 61076-3-112  CEI:2006 Figure – vue en coupe des contacts libres et fixes 28 Figure – Embase, modèle A 30 Figure 10 – Embase, modèle B 30 Figure 11 – Fiche mâle, modèle C 32 Figure 12 – Fiche mâle, modèle D 32 Figure 13 – Plan de perỗage pour embase, modốle A 34 Figure 14 Plan de perỗage pour embase, modèle B 36 Figure 15 – Arrangement pour la mesure de la résistance de contact 40 Figure 16 – Arrangement pour les essais de vibrations et de chocs 42 Figure 17 – Arrangement de câblage pour la tension de tenue et la résistance d'isolement 42 Figure B.1 – Etalonnage du montage d'impédance des paires de signaux 62 Figure B.2 – Configuration de mesure d'impédance des paires de signaux 64 Figure C.1 – Etalonnage du montage de l'essai de diaphonie 66 Figure C.2 – Mesure de la diaphonie 68 Tableau – Modèles de connecteur 16 Tableau – Type de sortie sur embase 30 Tableau – Types de sorties sur embase 34 Tableau – Niveaux de performance 36 Tableau – Lignes de fuite et distances d’isolement minimales 38 Tableau – Groupe d'essais A 44 Tableau – Groupe d’essais B 46 Tableau – Groupe d'essais C 48 Tableau – Groupe d’essais D 50 Tableau 10 – Groupe d’essais E 52 Tableau 11 – Groupe d’essais F 54 Tableau 12 – Groupe d'essais G 56 Tableau 13 – Groupe d'essais H 58 Tableau B.1 – Matrice de connexion pour essais d'impédance de paires de signaux 64 Tableau C.1 – Matrice de connexion pour les essais de diaphonie entre les paires de signaux 70 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Figure A.1 – Dispositif pour essai de flexion de câble 60 61076-3-112  IEC:2006 –5– Figure – Cross-section of free and fixed contacts 29 Figure – Fixed connector, style A 31 Figure 10 – Fixed connector, style B 31 Figure 11 – Free male connector, style C 33 Figure 12 – Free male connector, style D 33 Figure 13 – Hole pattern for fixed connector, style A 35 Figure 14 – Hole pattern for fixed connector, style B 37 Figure 15 – Arrangement for contact resistance measurement 41 Figure 16 – Arrangement for vibration and shock tests 43 Figure 17 – Wiring arrangement for voltage proof and insulation resistance 43 Figure A.1– Fixture for cable flexing test 61 Figure B.2 – Signal pairs impedance measurement configuration 65 Figure C.1 – Crosstalk setup calibration 67 Figure C.2 – Crosstalk measurement 69 Table – Connector styles 17 Table – Type of termination on fixed connector 31 Table – Types of terminations on free connector 35 Table – Performance levels 37 Table – Minimum creepage and clearance distances 39 Table – Test group A 45 Table – Test group B 47 Table – Test group C 49 Table – Test group D 51 Table 10 – Test group E 53 Table 11 – Test group F 55 Table 12 – Test group G 57 Table 13 – Test group H 59 Table B.1 – Connection matrix for signal pairs impedance tests 65 Table C.1 – Connection matrix for crosstalk tests between signal pairs 71 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Figure B.1 – Signal pairs impedance setup calibration 63 61076-3-112  CEI:2006 –6– COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE CONNECTEURS POUR ÉQUIPEMENTS ÉLECTRONIQUES – Partie 3-112: Connecteurs rectangulaires – Spécification particulière pour connecteurs rectangulaires quatre contacts pour bus série haute performance utilisés dans les équipements audio/vidéo grand public AVANT-PROPOS 2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI intéressés sont représentés dans chaque comité d’études 3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées comme telles par les Comités nationaux de la CEI Tous les efforts raisonnables sont entrepris afin que la CEI s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final 4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la mesure possible, appliquer de faỗon transparente les Publications de la CEI dans leurs publications nationales et régionales Toutes divergences entre toutes Publications de la CEI et toutes publications nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières 5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa responsabilité pour les équipements déclarés conformes une de ses Publications 6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication 7) Aucune responsabilité ne doit être imputée la CEI, ses administrateurs, employés, auxiliaires ou mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de toute autre Publication de la CEI, ou au crédit qui lui est accordé 8) L'attention est attirée sur les références normatives citées dans cette publication L'utilisation de publications référencées est obligatoire pour une application correcte de la présente publication 9) L’attention est attirée sur le fait que certains éléments de la présente publication peuvent faire l’objet de droits de propriété intellectuelle ou de droits analogues La CEI ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence La Norme internationale CEI 61076-3-112 a été établie par le sous-comité 48B, Connecteurs, du comité d'études 48 de la CEI: Composants électromécaniques et structures mécaniques pour équipements électroniques Le texte de cette norme est issu des documents suivants: FDIS Rapport de vote 48B/1620/FDIS 48B/1670/RVD Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant abouti l'approbation de cette norme LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI) La CEI a pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de l'électricité et de l'électronique A cet effet, la CEI – entre autres activités – publie des Normes internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI") Leur élaboration est confiée des comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer Les organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux travaux La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations 61076-3-112  IEC:2006 –7– INTERNATIONAL ELECTROTECHNICAL COMMISSION CONNECTORS FOR ELECTRONIC EQUIPMENT – Part 3-112: Rectangular connectors – Detail specification for rectangular connectors with four contacts for high performance serial bus for consumer audio/video equipment FOREWORD 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication 6) All users should ensure that they have the latest edition of this publication 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications 8) Attention is drawn to the Normative references cited in this publication Use of the referenced publications is indispensable for the correct application of this publication 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights IEC shall not be held responsible for identifying any or all such patent rights International Standard IEC 61076-3-112 has been prepared by subcommittee 48B: Connectors, of IEC technical committee 48: Electromechanical components and mechanical structures for electronic equipment The text of this standard is based on the following documents: FDIS Report on voting 48B/1620/FDIS 48B/1670/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees) The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”) Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations –8– 61076-3-112  CEI:2006 Cette publication a été rédigée selon les Directives ISO/CEI, Partie La liste de toutes les parties de la série CEI 61076, présentées sous le titre général Connecteurs pour équipements électroniques – Exigences de produit, peut être consultée sur le site web de la CEI Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les données relatives la publication recherchée A cette date, la publication sera • • • • reconduite; supprimée; remplacée par une édition révisée, ou amendée LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 61076-3-112  CEI:2006 – 64 – TDR TDR 50 Ω tr = 500 ps TpB* TDR TpA TDR* TDR TpA* Dispositif d’essai diff TDR TpB Dispositif d’essai diff TpB TpA* DES TDR TpB* TpA Légende : TpA: Paire torsadée A, TpB: Paire torsadée B, *: signal négatif, DES: Dispositif en essai (câble assemblé fiches) Figure B.2 – Configuration de mesure d'impédance des paires de signaux Tableau B.1 – Matrice de connexion pour essais d'impédance de paires de signaux Valeur mesurée Mode différentiel Dispositif (différentiel) Dispositif (différentiel) Ω Ω TpA TpA* TpB TpB* TpA TpA* TpB TpB* TDR TDR 50 50 50 50 50 50 50 50 TDR TDR 50 50 50 50 TpA (ZTpA conn ) Mode différentiel TpB (ZTpB conn ) * signal négatif B.3 Limites d'impédance des paires de signaux Les limites d'essai, pour la fenêtre d'exception de 100 ps, sont les suivantes: ZTpA conn = (110 ± 25) Ω ZTpB conn = (110 ± 25) Ω LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU IEC 506/06 61076-3-112  IEC:2006 – 65 – TDR TDR 50 Ω tr = 500 ps TpB* TDR TpA TDR* TDR TpA* Test fixture diff TDR TpB Test fixture diff TpB TpA* DUT TDR TpB* TpA Key: TpA: Twist pair A, TpB: Twist pair B, *: negative signal, DUT: Device under test (cable assembled free connectors) Figure B.2 – Signal pairs impedance measurement configuration Table B.1 – Connection matrix for signal pairs impedance tests Measured value Differential mode Fixture (differential) Fixture (differential) Ω Ω TpA TpA* TpB TpB* TpA TpA* TpB TpB* TDR TDR 50 50 50 50 50 50 50 50 TDR TDR 50 50 50 50 TpA (ZTpA conn ) Differential mode TpB (ZTpB conn ) * negative signal B.3 Signal pairs impedance limits The test limits, for the 100 ps exception window, are the following: ZTpA conn = (110 ± 25) Ω ZTpB conn = (110 ± 25) Ω LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU IEC 506/06 61076-3-112  CEI:2006 – 66 – Annexe C (normative) Diaphonie C.1 Etalonnage du montage pour l'essai de diaphonie L'étalonnage direct peut être réalisé comme représenté la Figure C.1 L'atténuation introduite par la connexion directe d'étalonnage qui remplace le DES doit être maintenue au niveau minimal En pratique, elle peut être assurée en utilisant un connecteur adaptateur SMA RFout 20 dB Rin Ain Bin 20 dB 20 dB Séparateur Séparateur 20 dB 20 dB IEC 507/06 Figure C – Etalonnage du montage de l'essai de diaphonie Légendes: L'analyseur de réseaux doit utiliser le montage suivant: Format Amplitude log Balayage Fréquence log Moyennage 16 Ouverture de lissage 10 % Puissance 25 dBm Démarrage MHz Arrêt 500 MHz Mesure A/B Affichage Données LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Analyseur de réseau 61076-3-112  IEC:2006 – 67 – Annex C (normative) Crosstalk C.1 Crosstalk setup calibration The through calibration can be performed as shown in Figure C.1 The attenuation introduced by the calibration interconnect that replaces the DUT shall be kept to a minimum Practically, it can be implemented using an SMA adaptor connector RFout 20 dB Rin Ain Bin 20 dB 20 dB splitter splitter 20 dB 20 dB IEC 507/06 Figure C.1 – Crosstalk setup calibration The network analyzer shall use the following setup: Format Log magnitude Sweep Log frequency Averaging 16 Smoothing aperture 10 % Power 25 dBm Start MHz Stop 500 MHz Measure A/B Display Data LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Network analyzer 61076-3-112  CEI:2006 – 68 – C.2 Procédure d'essai de diaphonie En utilisant la configuration d'essai décrite la Figure C.2 et la matrice de connexion représentée au Tableau C.1, la diaphonie entre les paires de signaux doit être mesurée dans le domaine de fréquences en utilisant un analyseur de réseaux dans la plage de fréquences de MHz – 75 MHz NOTE Bien que décrites comme une mesure de diaphonie paire paire, les configurations d'essai ont une seule extrémité équipée L'indication paire paire fait uniquement référence l'emplacement de la ligne conduite désignée et de la ligne inactive Analyseur de réseau RFout Ain Bin 20 dB 20 dB Séparateur Séparateur TpB* TpA TDR 20 dB Input Output TDR TpA* TDR TpB Dispositif d’essai Dispositif d’essai 20 dB TpB TpA* DES TDR TpB* TpA IEC 508/06 Légende : TpA: Paire torsadée A, TpB: Paire torsadée B, *: signal négatif, DES: Dispositif en essai (câble assemblé fiches) Figure C – Mesure de la diaphonie LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 20 dB Rin 61076-3-112  IEC:2006 C.2 – 69 – Crosstalk test procedure Using the test configuration described in Figure C.2 and the connection matrix shown in Table C.1, the crosstalk between signal pairs shall be measured in the frequency domain using a network analyzer in the frequency range of MHz – 75 MHz NOTE Although described as a measurement of pair-to-pair crosstalk, the test configurations are single-ended The phrase pair-to-pair refers only to the location of the designated driven line and quiet line Network analyzer RFout Ain Bin 20 dB 20 dB splitter splitter TpB* TpA TDR 20 dB Input Output TDR TpA* TDR TpB Test fixture Test fixture 20 dB TpB TpA* DUT TDR TpB* TpA IEC 508/06 Key: TpA: Twist pair A, TpB: Twist pair B, *: negative signal, DUT: Device under test (cable assembled free connectors) Figure C.2 – Crosstalk measurement LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 20 dB Rin 61076-3-112  CEI:2006 – 70 – Tableau C – Matrice de connexion pour les essais de diaphonie entre les paires de signaux Dispositif Ω Valeur mesurée Dispositif Ω TpA TpA* TpB TpB* TpA TpA* TpB TpB* Diaphonie entre TpA et TpB( X AB ) Sortie 50 50 50 Entrée 50 50 50 Diaphonie entre TpA et TpB*( X AB* ) Sortie 50 50 50 50 Entrée 50 50 Diaphonie entre TpA* et TpB( X A*B ) 50 Sortie 50 50 Entrée 50 50 50 Diaphonie entre TpA* et TpB*( X A*B* ) 50 Sortie 50 50 50 Entrée 50 50 C.3 Limites de diaphonie Les limites d'essai sont les suivantes: X AB ≤ –26 dB X AB* ≤ –26 dB X A*B ≤ –26 dB X A*B* ≤ –26 dB _ LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU * signal négatif 61076-3-112  IEC:2006 – 71 – Table C.1 – Connection matrix for crosstalk tests between signal pairs Fixture Ω Measured value Fixture Ω TpA* TpB TpB* TpA TpA* TpB TpB* Crosstalk between TpA and TpB( X AB ) Out 50 50 50 In 50 50 50 Crosstalk between TpA and TpB*( X AB* ) Out 50 50 50 50 In 50 50 Crosstalk between TpA* and TpB( X A*B ) 50 Out 50 50 In 50 50 50 Crosstalk between TpA* and TpB*( X A*B* ) 50 Out 50 50 50 In 50 50 * negative signal C.3 Crosstalk limits The test limits are the following: X AB ≤ –26 dB X AB* ≤ –26 dB X A*B ≤ –26 dB X A*B* ≤ –26 dB _ LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU TpA LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Standards Survey The IEC would like to offer you the best quality standards possible To make sure that we continue to meet your needs, your feedback is essential Would you please take a minute to answer the questions overleaf and fax them to us at +41 22 919 03 00 or mail them to the address below Thank you! Customer Service Centre (CSC) or Fax to: IEC/CSC at +41 22 919 03 00 Thank you for your contribution to the standards-making process Nicht frankieren Ne pas affranchir A Prioritaire Non affrancare No stamp required RÉPONSE PAYÉE SUISSE Customer Service Centre (CSC) International Electrotechnical Commission 3, rue de Varembé 1211 GENEVA 20 Switzerland LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU International Electrotechnical Commission 3, rue de Varembé 1211 Genève 20 Switzerland Q1 Please report on ONE STANDARD and ONE STANDARD ONLY Enter the exact number of the standard: (e.g 60601-1-1) Q6 standard is out of date R standard is incomplete R standard is too academic R standard is too superficial R title is misleading R I made the wrong choice R other Q2 Please tell us in what capacity(ies) you bought the standard (tick all that apply) I am the/a: Q3 Q7 I work for/in/as a: (tick all that apply) manufacturing R consultant R government R test/certification facility R public utility R education R military R other timeliness quality of writing technical contents logic of arrangement of contents tables, charts, graphs, figures other Q8 Q4 Q5 This standard meets my needs: (tick one) not at all nearly fairly well exactly R R R R I read/use the: (tick one) French text only English text only both English and French texts This standard will be used for: (tick all that apply) general reference R product research R product design/development R specifications R tenders R quality assessment R certification R technical documentation R thesis R manufacturing R other Please assess the standard in the following categories, using the numbers: (1) unacceptable, (2) below average, (3) average, (4) above average, (5) exceptional, (6) not applicable Q9 R R R Please share any comment on any aspect of the IEC that you would like us to know: LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU purchasing agent R librarian R researcher R design engineer R safety engineer R testing engineer R marketing specialist R other If you ticked NOT AT ALL in Question the reason is: (tick all that apply) Enquête sur les normes La CEI ambitionne de vous offrir les meilleures normes possibles Pour nous assurer que nous continuons répondre votre attente, nous avons besoin de quelques renseignements de votre part Nous vous demandons simplement de consacrer un instant pour répondre au questionnaire ci-après et de nous le retourner par fax au +41 22 919 03 00 ou par courrier l’adresse ci-dessous Merci ! Centre du Service Clientèle (CSC) ou Télécopie: CEI/CSC +41 22 919 03 00 Nous vous remercions de la contribution que vous voudrez bien apporter ainsi la Normalisation Internationale Nicht frankieren Ne pas affranchir A Prioritaire Non affrancare No stamp required RÉPONSE PAYÉE SUISSE Centre du Service Clientèle (CSC) Commission Electrotechnique Internationale 3, rue de Varembé 1211 GENÈVE 20 Suisse LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Commission Electrotechnique Internationale 3, rue de Varembé 1211 Genève 20 Suisse Q1 Veuillez ne mentionner qu’UNE SEULE NORME et indiquer son numéro exact: ( ex 60601-1-1) Q5 pas du tout peu près assez bien parfaitement Q2 En tant qu’acheteur de cette norme, quelle est votre fonction? (cochez tout ce qui convient) Je suis le/un: Q6 Je travaille: (cochez tout ce qui convient) dans l’industrie R comme consultant R pour un gouvernement R pour un organisme d’essais/ certification R dans un service public R dans l’enseignement R comme militaire R autre(s) Veuillez évaluer chacun des critères cidessous en utilisant les chiffres (1) inacceptable, (2) au-dessous de la moyenne, (3) moyen, (4) au-dessus de la moyenne, (5) exceptionnel, (6) sans objet publication en temps opportun qualité de la rédaction contenu technique disposition logique du contenu tableaux, diagrammes, graphiques, figures autre(s) Q8 Cette norme sera utilisée pour/comme (cochez tout ce qui convient) ouvrage de référence R une recherche de produit R une étude/développement de produit R des spécifications R des soumissions R une évaluation de la qualité R une certification R une documentation technique R une thèse R la fabrication R autre(s) Si vous avez répondu PAS DU TOUT Q5, c’est pour la/les raison(s) suivantes: (cochez tout ce qui convient) la norme a besoin d’être révisée R la norme est incomplète R la norme est trop théorique R la norme est trop superficielle R le titre est équivoque R je n’ai pas fait le bon choix R autre(s) Q7 Q4 R R R R Je lis/utilise: (une seule réponse) uniquement le texte franỗais uniquement le texte anglais les textes anglais et franỗais Q9 R R R Veuillez nous faire part de vos observations éventuelles sur la CEI: LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU agent d’un service d’achat R bibliothécaire R chercheur R ingénieur concepteur R ingénieur sécurité R ingénieur d’essais R spécialiste en marketing R autre(s) Q3 Cette norme répond-elle vos besoins: (une seule réponse) LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ISBN 2-8318-8593-0 -:HSMINB=] Z^X : ICS 31.220.10 Typeset and printed by the IEC Central Office GENEVA, SWITZERLAND

Ngày đăng: 17/04/2023, 10:46

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN