1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Iec 60864 1 1986 amd1 1987 scan

14 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 14
Dung lượng 578,64 KB

Nội dung

NORME INTERNATIONALE INTERNATIONAL STAN DARD CEI IEC 60864 1 1986 AMENDEMENT 1 AMENDMENT 1 1987 05 Amendement 1 Normalisation des interconnexions entre les émetteurs ou les systèmes d''''émetteurs de rad[.]

NORME INTERNATIONALE CEI IEC 60864-1 INTERNATIONAL STAN DARD 1986 AMENDEMENT AMENDMENT 1987-05 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Amendement Normalisation des interconnexions entre les émetteurs ou les systèmes d'émetteurs de radiodiffusion et les systèmes de télésurveillance Première partie: Normes d'interface pour les systèmes interconnexions câblées Amendment Standardization of interconnections between broadcasting transmitters or transmitter system and supervisory equipment Part 1: Interface standards for systems using dedicated interconnections © IEC 1987 Droits de reproduction réservés —Copyright - all rights reserved International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch IEC• Commission Electrotechnique Internationale International Electrotechnical Commission McJl yHapol3HaH 3neHTpoTexHH4eCHaR HOMHCCHH • CODE PRIX PRICE CODE ^ V Pour prix, voir catalogue en vigueur For price, see current catalogue – – 864-1 mod © CEI 1987 PRÉFACE La présente modification a été établie par le Sous-Comité 12 C: Matériels émetteurs, du Comité d'Etudes n° 12 de la C E I: Radiocommunications Le texte de cette modification est issu des documents suivants: Règle des Six Mois Rapports de vote 12C(BC)183 12C(BC)184 12C(BC)192 12C(BC)193 Les rapports de vote indiqués dans le tableau ci-dessus donnent toute information sur le vote ayant abouti l'approbation de cette modification 11 Techniques opto-isolateurs Remplacer le titre et A l'étude par le texte suivant: 11 Techniques photocoupleurs Le principe de la technique photocoupleurs est illustré par la figure 5, page Les précautions d'usage doivent être prises pour empêcher les défauts de fonctionnement dus aux tensions indésirées induites dans les liaisons entre l'émetteur et l'équipement de télésurveillance ou l'unité du système logique 11.1 Commandes Les ordres sont envoyés l'émetteur au moyen de dispositifs de commutation photocoupleur ou de contacts flottants situés dans l'équipement de télésurveillance ou dans l'unité du système logique Le système logique de l'émetteur doit être compatible avec l'une ou l'autre des techniques suivantes: 1) Fermeture permanente du circuit de commande au moyen du dispositif approprié de l'équipement de surveillance ou de l'unité du système logique pendant la durée de maintien de l'ordre L'ordre contraire est obtenu par l'ouverture du circuit et, dans ce cas, un seul circuit de commande suffit 2) Fermeture momentanée pendant une durée de 20 ms 500 ms Dans ce cas, l'ordre contraire est assuré au moyen d'un circuit de commande supplémentaire La fermeture permanente intempestive de circuits prévus pour fonctionner en fermeture momentanée ne doit pas empêcher le fonctionnement normal des émetteurs 11.1.1 Dispositions relatives aux circuits Les circuits de commande peuvent avoir un retour commun connecté la terre et au pôle négatif de l'alimentation dans l'émetteur LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Page 14 864-1 Amend © IEC 1987 –3PREFACE This amendment has been prepared by Sub-Committee 12 C: Transmitting Equipment, of I E C Technical Committee No 12: Radiocommunications The text of this amendment is based upon the following documents: Six Months' Rule Repo rt on Voting 12C(CO)183 12C(CO)184 12C(CO)192 12C(CO)193 Full information on the voting for the approval of this Amendment can be found in the Reports on Voting indicated in the above table 11 Opto-isolator techniques Replace title and Under consideration by the following text: 11 Photocoupler techniques The principle of photocoupler techniques is illustrated in Figure 5, page Appropriate precautions shall be taken to prevent misoperation as a result of unwanted voltages induced on the interconnections between the transmitter and supervisory equipment or system logic unit 11.1 Commands Commands are sent to the transmitter by means of photocoupled switching devices or floating contacts located in the supervisory equipment or system logic unit The transmitter logic shall be compatible with one or the other of the following two techniques: 1) Continuous closure of the command circuit by the appropriate switching device in the supervisory equipment or system logic unit for the duration of the required state The opposite state is achieved by opening the circuit and in this case, only a single command circuit is required 2) Momentary closure of the circuit with a duration between 20 ms and 500 ms In this case, the opposite command requires an additional command circuit Unintentional continuous closure of circuits which are intended for momentary closure shall not interfere with the normal operation of the transmitters 11.1.1 Circuit requirements Command circuits may employ a common return connected to the earthed negative of the power supply in the transmitter LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Page 15 864-1 mod © CEI 1987 – – Les bornes d'interface des circuits de commande ne doivent pas être reliées la terre dans l'équipement de surveillance ou l'unité du système logique 11.1.2 Niveau de tension et niveau de courant des signaux Les deux états des tensions ou des courants continus binaires doivent se trouver dans les limites données dans le tableau I ci-après TABLEAU I Tension sur les bornes (V) Commande ou indication Min Nom Courant au niveau des bornes (mA) Max Nom Max 10 Circuit fermé —1 Circuit ouvert 18 24 30 — 0,6 11.1.3 Protection contre les impulsions Les circuits de commande doivent être protégés contre les effets destructifs des impulsions parasites Cela peut être vérifié en déchargeant un condensateur de 3311F, chargé au préalable 250 V, dans chaque circuit de commande 11.2 Indications Comme on peut le voir la figure 5, page 6, les indications sont envoyées l'équipement de télésurveillance ou l'unité du système logique au moyen de dispositifs de commutation photocoupleur situés dans l'émetteur 11.2.1 Dispositions relatives aux circuits Le fonctionnement du circuit d'indication doit être continu pour la durée de l'état signalé Les circuits d'indication peuvent avoir un retour commun Les bornes d'interface des circuits d'indication ne doivent pas être reliées la terre dans l'émetteur 11.2.2 Niveau de tension et niveau de courant des signaux Les deux états des tensions ou de courants continus binaires doivent se trouver dans les limites données dans le tableau I 11.2.3 Protection contre les impulsions Les circuits d'indication doivent être protégés contre les effets destructifs des impulsions parasites Cela peut être vérifié en déchargeant un condensateur de 33 µF, chargé au préalable à250 V, dans chaque circuit d'indication, le circuit étant successivement dans l'un des deux états: ouvert ou fermé LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Min 864-1 Amend 1© I E C 1987 – 5– The command circuit terminals on the supervisory equipment or system logic unit shall be earth free 11.1.2 Signal voltage and signal current levels The two states of the binary d.c voltage or current shall be within the limits given in Table I below TABLE I Terminal voltage (V) Command or indication Min Nom Terminal current (mA) Max Min Nom —1 Circuit open 18 24 30 — 10 0.6 11.1.3 Transient protection Command circuits shall be protected against damage from transients This may be verified by discharging a 33 tiF capacitor charged at 250 V across each command circuit 11.2 Indications As can be seen from Figure 5, page 7, indications are sent to the supervisory equipment or system logic unit by means of photocoupled switching devices located in the transmitter 11.2.1 Circuit requirements The indication circuit shall operate continuously for the duration of the indicated status Indication circuits may or may not employ a common return The indication circuit terminals on the transmitter shall be earth free 11.2.2 Signal voltage and signal current levels The two states of the binary d.c voltage or current shall be within the limits given in Table I 11.2.3 Transient protection Indication circuits shall be protected against damage from transients This may be verified by discharging a 33 µF capacitor charged at 250 V across each indication circuit in both states, i.e open and closed LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Circuit closed Max -6 864-1 mod 1O CEI 1987 o Commande Logique semiconducteurs ou photocoupleur o o I Commande o Ver entrée ^Vers entrée Logique semiconducteurs ou photocoupleur ^ L- O Indication Logique semiconducteurs ou photocoupleur Dep uis sortie o o Indication o Logique semiconducteurs ou photocoupleur Depuis sortie f ^ 350/87 FIG — Principe des techniques d'interface semiconducteurs et photocoupleur LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Emetteur 864-1 Amend © IEC 1987 —7— I Command Command o f Semiconductor logic or phôtocoupler - To i nput Semiconductor logic or photocoupler ^ To input L- O Indication Semiconductor logic or photocoupler From output O Indication o Semiconductor logic or photocoupler From output ^ 350/37 FIG — Principle of semiconductor logic and photocoupler interface techniques LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Transmitter — 864-1 mod © CEI 1987 Page 24 SECTION QUATRE Remplacer le titre et A l'étude par le texte suivant: SECTION QUATRE — TECHNIQUES NORMALISÉES D'INTERFACE (ANALOGUES) 18 Introduction Dans un système utilisant les techniques analogiques, les commandes sont envoyées depuis l'équipement de surveillance l'émetteur, et les indications sont envoyées en sens inverse, au moyen de tensions ou de courants variables Les configurations générales illustrant les deux techniques sont montrées la figure 7, page 12 19 Dispositions relatives aux circuits Les dispositions sont les mêmes pour les circuits de commande et d'indication Les bornes d'interface ne doivent pas être reliées la terre et le câblage doit être fait au moyen de paires blindées, le blindage ộtant reliộ la terre de faỗon appropriộe Le tableau VII montre les dispositions relatives au fonctionnement en tension ou en courant TABLEAU VII Caractéristiques Fonctionnement en tension Fonctionnement en courant V +10 V mA 20 mA Résistance de charge (R i ) 000 S2 000 12 max Résistance de source (R ;) 100 S2 max Dynamique du signal (B) Tension maximale positive ou négative en mode commun * Voir la Publication 864-1 de la CEI 25 V grande, comparée la résistance de charge plus la résistance de boucle LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Les commandes et les indications de hors tolérances relatives aux systèmes analogiques peuvent également utiliser la technique binaire décrite dans la section deux Par exemple, la commande «augmenter/diminuer» peut être une commande binaire avec une indication sous forme analogique ou la commande peut être analogique avec une indication de hors tolérances sous forme binaire (Voir également figure 1*.) 864-1 Amend © IEC 1987 Page 25 SECTION FOUR Replace title and Under consideration by the following text: SECTION FOUR — STANDARD INTERFACE TECHNIQUES (ANALOGUE) 18 Introduction In systems using analogue techniques, commands are sent from the supervisory equipment to the transmitter and indications are sent in the reverse direction by means of va riable voltage or current levels General system configurations illustrating these techniques are shown in Figure 7, page 13 19 Circuit requirements The requirements are the same for both command and indication circuits The interface terminals shall be earth-free and the circuit wiring shall be by means of shielded pairs, with the shield earthed as required Table VII shows the circuit requirements for voltage or current operation TABLE VII Characteristics Range of signal (B) Load resistance (R ) Source resistance (Rh) Voltage operation Current operation V to +10 V mA to 20 mA l 000 Q 000 Q, max high, compared to load plus loop resistance 100 Q max ll Maximum positive or negative common mode voltage * See IEC Publication 864-1 25 V LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Commands and out-of-limit indications relating to analogue systems may also use the binary techniques described in Section Two For example, the command raise/lower can be a binary command with the indication in analogue form or the command can be analogue with the out-of-limit indications being binary (See also Figure 1*.) — 10 — 864-1 mod © CEI 1987 SECTION CINQ — COMMANDES ET INDICATIONS ANALOGIQUES Remplacer le texte (A l'étude) par le texte suivant: 20 Introduction Cette section concerne les commandes et indications qui peuvent prendre de nombreux états, c'est-à-dire être continûment variables entre deux limites 21 Dispositions relatives l'émetteur Le tableau VIII ci-dessous donne un exemple de dispositions analogiques habituellement utilisées Disposition Niveau de puissance de sortie Commande Indication x x x Tension continue d'alimentation de l'étage final x Courant continu de l'étage final Niveau de modulation Note x x I) L'indication est sous forme analogique Des contacts d'alarme peuvent être prévus pour signaler les fonctionnements hors tolérances LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU TABLEAU VIII 864-1 Amend © I E C 1987 — 11 — SECTION FIVE — ANALOGUE COMMANDS AND INDICATIONS Replace the text (Under consideration) by the following text: 20 Introduction This section deals with commands and indications which are in one of many possible states, i.e continuously variable between two limits 21 Transmitter facilities Table VIII below shows examples of typical analogue facilities Facility Power output level Command Indication x x x Final amplifier d.c supply voltage Final amplifier d.c current Modulation level Note x x x "The indication is an analogue presentation Alarm contacts may be provided for out-of-limit conditions o LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU TABLE VIII — 12 — 864-1 mod © CEI 1987 Système en tension o ^ o Commande — Os- ^ C ^ CO Q) = Q) Q > En o — (I) O E Ri o J ^ mmilli■ • o + Commande o • Ri •a) (1) ^ E ,^ a a) a) ^ -o Ç ^ â c -p -ơ o o o • E ,,Q)Q a) CO • ^ o m Q^^ ^ ^ D o O o o Indication O _ Indication o E • I +o • r" E Rs o o - _■► ^ o ^J ^ Emetteur Bornes d'interface 351/87 Système en courant o ^ Commande ^ o^ ,- a) (0 a) o o o > (1) c:o E o ^ ,a) Q) E a, o ^,^ O o c -6 ■141111•- o • o V + Commande • O Ri • — a) N -0 ?+-^ (/) O N O E ^o O O O fl- V ^ C a) E – Da 6m C -cs o o + Indication o o V r^ + • o o Indication o o • Rs o O >—° • Rs ■110► O ^ o Bornes d'interface • Emetteur 352/87 FIG — Exemple de la technique d'interface analogique LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ^ Rs —^ o ^.! O • r-7 +o 864-1 Amend © I E C 1987 — 13 — Voltage system o O Command a) ÿ Ç U E U co p_ ` o (1) E— co ?"- c > co v) g_) co Command a, a o O o J n O • O • ô O >0 >0 o + O E Rs o ^ ã o Indication o o ^ o ỗõ^ U_ o o a) U W Ri o ^ n O + o E Rs o o o o v Transmitter Inte rf ace terminals 351/87 Current system o n Command o o a) O ^ U _c ỗ E " ô — E a) â,) o Q) ^ U1 ^ /\ + o a ^ ^ ô 0 ^ O ^ O + • T YYY O I O Indication • RS o O O • RS o N N >-0 o o Indication C (J) ` m • O o U- i n Command E Ec a ^ ^ ^ >0 ^ O a) • R^ V Interface terminals o T Transmitter 352/87 FIG — Example of analogue interface technique LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Indication LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ICS 33.060.20 ; 33.200 Typeset and printed by the IEC Central Office GENEVA, SWITZERLAND

Ngày đăng: 17/04/2023, 10:43