1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Iec 60603 7 7 2010

60 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

IEC 60603-7-7 ® Edition 3.0 2010-05 INTERNATIONAL STANDARD colour inside Connectors for electronic equipment – Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz IEC 60603-7-7:2010 Connecteurs pour équipements électroniques – Partie 7-7: Spécification particulière pour les fiches et les embases blindées voies pour la transmission de données des fréquences jusqu'à 600 MHz LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU NORME INTERNATIONALE THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright © 2010 IEC, Geneva, Switzerland All rights reserved Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IEC's member National Committee in the country of the requester If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information Droits de reproduction réservés Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies About IEC publications The technical content of IEC publications is kept under constant review by the IEC Please make sure that you have the latest edition, a corrigenda or an amendment might have been published ƒ Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…) It also gives information on projects, withdrawn and replaced publications ƒ IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications Just Published details twice a month all new publications released Available on-line and also by email ƒ Electropedia: www.electropedia.org The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages Also known as the International Electrotechnical Vocabulary online ƒ Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csc@iec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des normes internationales pour tout ce qui a trait l'électricité, l'électronique et aux technologies apparentées A propos des publications CEI Le contenu technique des publications de la CEI est constamment revu Veuillez vous assurer que vous possédez l’édition la plus récente, un corrigendum ou amendement peut avoir été publié ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence, texte, comité d’études,…) Il donne aussi des informations sur les projets et les publications retirées ou remplacées ƒ Just Published CEI: www.iec.ch/online_news/justpub Restez informé sur les nouvelles publications de la CEI Just Published détaille deux fois par mois les nouvelles publications parues Disponible en-ligne et aussi par email ƒ Electropedia: www.electropedia.org Le premier dictionnaire en ligne au monde de termes électroniques et électriques Il contient plus de 20 000 termes et définitions en anglais et en franỗais, ainsi que les termes ộquivalents dans les langues additionnelles Egalement appelé Vocabulaire Electrotechnique International en ligne ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du Service clients ou contactez-nous: Email: csc@iec.ch Tél.: +41 22 919 02 11 Fax: +41 22 919 03 00 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU IEC Central Office 3, rue de Varembé CH-1211 Geneva 20 Switzerland Email: inmail@iec.ch Web: www.iec.ch IEC 60603-7-7 ® Edition 3.0 2010-05 INTERNATIONAL STANDARD colour inside Connectors for electronic equipment – Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz Connecteurs pour équipements électroniques – Partie 7-7: Spécification particulière pour les fiches et les embases blindées voies pour la transmission de données des fréquences jusqu'à 600 MHz INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE PRICE CODE CODE PRIX ICS 31.220.10 ® Registered trademark of the International Electrotechnical Commission Marque déposée de la Commission Electrotechnique Internationale U ISBN 978-2-88910-967-8 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU NORME INTERNATIONALE –2– 60603-7-7 © IEC:2010 CONTENTS FOREWORD INTRODUCTION General 1.1 Scope 1.2 Normative references Terms and definitions .8 Common features and isometric view .8 3.1 General 3.2 Isometric view 3.3 Common features 3.4 Engagement (mating) information 3.5 Fixed connectors 10 3.6 Free connectors 12 Cable terminations and internal connections 14 4.1 General 14 4.1.1 Complete connectors (pairs) 14 4.1.2 Switch function 15 4.2 Termination types 15 Gauges 15 5.1 Fixed connectors 15 5.2 Free connectors 18 Characteristics 20 6.1 6.2 6.3 6.4 6.5 General 20 Pin and pair grouping assignment 21 Climatic category 22 Electrical characteristics 22 Transmission characteristics 22 6.5.1 General 22 6.5.2 Insertion loss 23 6.5.3 Return loss 23 6.5.4 Propagation delay 23 6.5.5 Delay skew 23 6.5.6 NEXT 23 6.5.7 Power sum NEXT (for information only) 24 6.5.8 FEXT 24 6.5.9 Power sum FEXT (for information only) 24 6.5.10 Transverse conversion loss 24 6.5.11 Transverse conversion transfer loss 24 6.6 Mechanical characteristics 25 6.6.1 Mechanical operation 25 6.6.2 Effectiveness of connector coupling devices 25 6.6.3 Insertion and withdrawal forces 25 Tests and test schedule 25 7.1 7.2 7.3 General 25 Arrangement for contact resistance test: 25 Arrangement for vibration test 25 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 60603-7-7 © IEC:2010 –3– 7.4 7.5 7.6 Test procedures and measuring methods 25 Preconditioning 25 Wiring and mounting of specimens 25 7.6.1 Wiring 25 7.6.2 Mounting 25 7.7 Test schedules 25 7.7.1 Basic (minimum) test schedule 25 7.7.2 Full test schedule 26 Bibliography 28 Figure – Isometric view, example of fixed and free connector, free connector shown with both switch positions .9 Figure – Physical interface, fixed connector, front view 11 Figure – Physical interface, fixed connector, side view 11 Figure – Physical interface, free connector 13 Figure – Fixed connector additional go gauge 16 Figure – Fixed connector additional no-go gauges 17 Figure – Free connector additional no-go gauges 19 Figure – Free connector additional go gauges 20 Figure 10 – Fixed connector pin and pair grouping assignment (front view of connector) 21 Figure 11 – Basic switch function (Note: colours stated are an example of colours which may be used) 21 Figure 12 – Additional switch function (Note: colours stated are an example of colours which may be used) 22 Table – Physical interface, contacts interface 10 Table – Fixed connector common dimensions 12 Table – Common dimensions – free connector 14 Table – Fixed connector, additional, gauge dimensions 18 Table – Free connector additional gauges dimensions 20 Table – Test group EP 26 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Figure – Contact interface dimensions with terminated free connector 10 –4– 60603-7-7 © IEC:2010 INTERNATIONAL ELECTROTECHNICAL COMMISSION CONNECTORS FOR ELECTRONIC EQUIPMENT – Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz FOREWORD 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter 5) IEC itself does not provide any attestation of conformity Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity IEC is not responsible for any services carried out by independent certification bodies 6) All users should ensure that they have the latest edition of this publication 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications 8) Attention is drawn to the Normative references cited in this publication Use of the referenced publications is indispensable for the correct application of this publication 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights IEC shall not be held responsible for identifying any or all such patent rights International Standard IEC 60603-7-7 has been prepared by subcommittee 48B: Connectors, of IEC technical committee 48: Electromechanical components and mechanical structures for electronic equipment This third edition of IEC 60603-7-7 cancels and replaces the second edition issued in 2006, and constitutes a technical revision The main technical changes with regard to the previous edition are as follows: – Removal of test methods that are now referenced to IEC 60512-26-100 – Addition of TCL and TCTL requirements – Removal of the electrical, mechanical, dimensional, environmental conditioning tests by reference to IEC 60603-7 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees) The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”) Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations 60603-7-7 © IEC:2010 –5– The text of this standard is based on the following documents: FDIS Report on voting 48B/2152/FDIS 48B/2187/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table This publication has been drafted in accordance with the ISO/IEC Directives, Part A list of all parts of IEC 60603 series, under the general title Connectors for electronic equipment, can be found on the IEC website • • • • reconfirmed, withdrawn, replaced by a revised edition, or amended IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents Users should therefore print this document using a colour printer LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific publication At this date, the publication will be –6– 60603-7-7 © IEC:2010 INTRODUCTION IEC 60603-7 is the base specification of the whole series Subsequent specifications not duplicate information given in the base document, but list only additional requirements For complete specification regarding a component of a higher number document all lower numbered documents shall be considered as well The following diagram shows the interrelation of the documents: Unshielded Shielded IEC 60603-7 IEC 60603-7-1 100 MHz IEC 60603-7-2 IEC 60603-7-3 250 MHz IEC 60603-7-4 IEC 60603-7-5 500 MHz IEC 60603-7-41 600 MHz Indicates reference for dimensions, mechanical and electrical characteristics, tests and test schedules 000 MHz IEC 60603-7-51 IEC 60603-7-7 IEC 60603-7-71 Indicates reference for transmission performance (backward compatibility) LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU MHz 60603-7-7 © IEC:2010 –7– CONNECTORS FOR ELECTRONIC EQUIPMENT – Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz General 1.1 Scope These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause of IEC 60603-7-1, 1.2 Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies IEC 60512-1-100: Connectors for electronic equipment – Part 1-100: General – Applicable publications IEC 60512-2-1, Connectors for electronic equipment – Tests and measurements – Part 2-1: Electrical continuity and contact resistance tests – Test 2a: Contact resistance – Millivolt level method IEC 60512-25-9, Connectors for electrical equipment – Tests and measurements – Part 25-9: Signal integrity tests – Test 25i: Alien crosstalk IEC 60512-27-100, Connectors for electronic equipment – Tests and measurements – Part 27-100: Signal integrity tests up to 500 MHz on IEC 60603-7 series connectors – Tests 27a to 27g IEC 60603-7:2008, Connectors for electronic equipment – Part 7: Detail specification for 8way, unshielded, free and fixed connectors IEC 60603-7-1:2009, Connectors for electronic equipment – Part 7: Detail specification for 8way, shielded, free and fixed connectors IEC 60603-7-71, Connectors for electronic equipment – Part 7-51: Detail specification for 8way, shielded, free and fixed connectors, for data transmissions with frequencies up to 000 MHz IEC 61156 (all parts): Multi-core and symmetrical pair/quad cables for digital communications ————————— To be published To be published LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU This part of IEC 60603 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for frequencies up to 600 MHz These connectors are typically used as category connectors in class F cabling systems specified in ISO/IEC 11801 –8– 60603-7-7 © IEC:2010 Terms and definitions For the purposes of this document, the terms and definitions given in Clause of IEC 60603-7 and Clause of IEC 60603-7-1 apply as well as the following 2.1 backward compatibility the backward compatibility requirement ensures that a free or fixed connector which is in compliance with this standard, mated with a fixed or free connector respectively in compliance with any lower frequency IEC 60603-7 series connector, fully complies with the requirements of the lower frequency IEC 60603-7 series connector Common features and isometric view Dimensions, views and requirements applicable to all IEC 60603-7-7 connectors are given herein for fixed connectors and free connectors 3.1 General The shape of the connectors may deviate from those given in the following drawings as long as the specified dimensions are not influenced Dimensions are given in millimetres Drawings are shown in first angle projection unless specifically stated otherwise in the figure LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU See Clause of IEC 60603-7 for dimensions, views and requirements applicable to all IEC 60603-7 connectors See Clause of IEC 60603-7-1 for dimensions, views and requirements applicable to all shielded IEC 60603-7 connectors – 44 – 5.1 60603-7-7 © CEI:2010 Calibres Embases Voir 5.1 de la CEI 60603-7-1 En plus des calibres décrits en 5.1 de la CEI 60603-7-1, les calibres suivants permettront la réalisation des essais des caractéristiques spécifiques de la CEI 60603-7-7 CQ3 CB3 IEC 1074/06 Figure – Calibre Entre supplémentaire – Embase LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CA3 CT3 60603-7-7 © CEI:2010 – 45 – CA5 CT5 CQ5 Calibre de largeur LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CA7 CT7 CQ7 Calibre de hauteur CA9 CT9 CQ9 Calibre de profondeur Figure – Calibres N’entrent pas supplémentaires – Embase IEC 1133/10 60603-7-7 © CEI:2010 – 46 – Tableau – Embase – dimensions des calibres supplémentaires Lettre 5.2 Minimum mm 2,03 2,03 2,3 2,03 2,08 5,55 5,55 5,55 6,0 12,81 13,0 12,81 12,81 Fiches Voir 5.2 de la CEI 60603-7-1 En plus des calibres décrits 5.1 de la CEI 60603-7-1, les calibres suivants permettront de réaliser les essais des caractéristiques spécifiques de la CEI 60603-7-7 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CA3 CA5 CA7 CA9 CB3 CQ3 CQ5 CQ7 CQ9 CT3 CT5 CT7 CT9 Maximum mm 2,17 2,17 2,31 2,17 2,27 5,7 5,7 5,7 6,01 12,87 13,01 12,87 12,87 60603-7-7 © CEI:2010 – 47 – CA4 CT4 CQ4 Calibre de largeur LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CA6 CT6 CQ6 Calibre de largeur CA8 CT8 CQ8 Calibre de hauteur IEC 1134/10 Figure – Fiche – Calibres N’entrent pas supplémentaires 60603-7-7 © CEI:2010 – 48 – CA2 CT2 IEC 1081/06 Figure – Fiche – Calibres Entrent supplémentaires Tableau – Fiche – dimensions des calibres supplémentaires Maximum Minimum mm mm CA2 2,22 2,21 CA4 2,22 2,21 CA6 2,22 2,21 CA8 2,0 1,99 CQ2 5,81 5,71 CQ4 5,81 5,71 CQ6 5,7 5,69 CQ8 5,81 5,71 CT2 12,96 12,86 CT4 12,85 12,84 CT6 12,96 12,86 CT8 12,96 12,86 Lettre 6.1 Caractéristiques Généralités L'ensemble des exigences et des programmes d'essais s'applique aux connecteurs accouplés y compris le commutateur sauf spécification contraire Les connecteurs conformes la CEI 60603-7-7 doivent aussi être conformes toutes les exigences applicables spécifiées par la CEI 60603-7 et la CEI 60603-7-1 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CQ2 60603-7-7 © CEI:2010 6.2 – 49 – Affectation de groupement des broches et des paires Pour les spécifications pour lesquelles les groupements de broches et de paires s’appliquent, sauf spécification contraire, les affectations de groupement de broches et de paires doivent être telles que représenté la Figure 10 3’ 4’ 5’ LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 6’ IEC 1082/06 Figure 10 – Affectation de groupement de broches et de paires d’embases (vue de face du connecteur) White-orange Orange 3′ White-green 4′ Blue 5′ White-blue 6′ Green White-brown Brown IEC 1083/06 NOTE Les couleurs indiquées donnent un exemple qui peut être utilisé Figure 11 – Fonction commutateur de base – 50 – 60603-7-7 © CEI:2010 White-orange Orange 3a White-green 4a Blue 5a 6a Green White-brown Brown IEC 1084/06 NOTE Les couleurs indiquées donnent un exemple qui peut être utilisé Figure 12 – Fonction commutateur supplémentaire 6.3 Catégorie climatique Les connecteurs conformes la CEI 60603-7-71 sont classés dans les mêmes catégories climatiques que celles définies par la CEI 60603-7 6.4 6.4.1 Caractéristiques électriques 6.4.8 Impédance de transfert Conditions: CEI 60512, Essai 26e Connecteurs accouplés, terminaison avec chaque construction de câble autorisée pour ces connecteurs Tous les types: ≤0,05f 0,3 Ω de MHz 10 MHz ≤0,01f Ω de 10 MHz 80 MHz 6.5 6.5.1 Caractéristiques de transmission Généralités La conformité la présente norme en ce qui concerne les caractéristiques de transmission, est déterminée conformément aux méthodes d’essai spécifiques décrites dans le groupe d’essai EP, voir Tableau L’interopérabilité des connecteurs conformes la présente norme doit être démontrée en soumettant les embases des essais avec toute la gamme des fiches LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU White-blue 60603-7-7 © CEI:2010 – 51 – conformes la CEI 60512-27-100 jusqu’à 500 MHz La conformité la présente norme en ce qui concerne la diaphonie exogène est déterminée conformément aux méthodes d’essai spécifiques décrites dans la CEI 60512-25-9 Les performances de transmission et la compatibilité amont doivent être démontrées en soumettant aux essais les embases avec toute la gamme des fiches décrite dans la CEI 60512-27-100 Toutes les exigences de performance de transmission s’appliquent entre les plans de référence spécifiés dans la CEI 60512-27-100 NOTE 6.5.2 Dans les paragraphes suivants, f désigne la fréquence exprimée en MHz Perte d'insertion CEI 60512,Essai 27a pour l’interface 60603-7-1 Une future norme CEI pour l’interface 60603-7-7 Connecteurs accouplés Toute les paires: ≤ 0,02 √f dB, de MHz 600 MHz Dès que l’exigence donne une valeur inférieure 0,1 dB, l'exigence doit revenir 0,1 dB 6.5.3 Affaiblissement de réflexion Conditions: CEI 60512, Essai 27b pour l’interface 60603-7-1 Une future norme CEI pour l’interface 60603-7-7 Connecteurs accouplés Toutes les paires: ≥ 68-20log (f) dB, de MHz 600 MHz Dès que l’exigence donne une valeur supérieure 30 dB, l'exigence doit revenir 30 dB 6.5.4 Temps de propagation Toutes les paires: ≤ 2,5 ns de MHz 000 MHz, où f est la fréquence en MHz La réalisation de l’essai de temps de propagation n’est pas nécessaire, dans la mesure où l’on estime que les connecteurs sont conformes de par leur conception 6.5.5 Dispersion du temps de propagation Toutes les combinaisons de paires: ≤ 1,25 ns NOTE Cette caractéristique est calculée partir des mesures individuelles du temps de propagation et, comme avec le temps de propagation (6.5.4), on estime que les connecteurs sont conformes de par leur conception 6.5.6 NEXT Conditions: CEI 60512, Essai 27c pour l’interface 60603-7-1 Une future norme CEI pour l’interface 60603-7-7 Connecteurs accouplés _ En ce qui concerne les performances de transmission, l’interopérabilité et la compatibilité amont, la CEI 6051226-100 peut aussi être utilisée comme alternative la CEI 60512-27-100 pour les matériels de connexion qui ont été qualifiés précédemment selon la CEI 60603-7-7, édition dans l’interface de la CEI 60603-7-1 Il doit être mentionné quand la CEI 60512-26-100 est utilisée Une future norme CEI 60512 pour les essais jusqu’à 600 MHz est l’étude LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Conditions: – 52 – 60603-7-7 © CEI:2010 Toutes les combinaisons de paires: ≥ 102,4 - 15log(f) dB, de MHz 600 MHz Dès que l’exigence donne une valeur supérieure 75 dB, l'exigence doit revenir 75 dB 6.5.7 Puissance cumulée de paradiaphonie (pour information uniquement) Conditions: Connecteurs accouplés PS NEXTk = −10 log n ∑10 − NEXTik 10 i =1, i ≠ k Toutes les paires: ≥ 99,4 -15log (f) dB, de MHz 600 MHz 6.5.8 FEXT Conditions: CEI 60512, Essai 27d pour l’interface 60603-7-1 Une future norme CEI pour l’interface 60603-7-7 Connecteurs accouplés Toutes les combinaisons de paires: ≥ 90-15log (f) dB, de MHz 600 MHz Dès que l’exigence donne une valeur supérieure 75 dB, l'exigence doit revenir 75 dB 6.5.9 Puissance cumulée de télédiaphonie (pour information uniquement) Conditions: Connecteurs accouplés PS FEXTk = −10 log n ∑10 − FEXTik 10 i =1,i ≠ k Toutes les paires: ≥ 87-15log (f) dB, de MHz 600 MHz NOTE Cette caractéristique est calculée partir des mesures individuelles de télédiaphonie et la conformité du connecteur est obtenue par conformité aux exigences de télédiaphonie (6.5.8) 6.5.10 Affaiblissement de symétrie Conditions: CEI 60512, Essai 27f pour l’interface 60603-7-1 Une future norme CEI pour l’interface 60603-7-7 Connecteurs accouplés Toutes les paires: ≥ 68-20log (f) dB, de MHz 600 MHz Dès que l’exigence donne une valeur supérieure 50 dB, l'exigence doit revenir 50 dB NOTE 6.5.11 Actuellement, la méthode d’essai est limitée 100 MHz (Voir la CEI 60512-27-100) Affaiblissement de symétrie l’extrémité distante Conditions: CEI 60512, Essai 27g pour l’interface 60603-7-1 Une future norme CEI pour l’interface 60603-7-7 Connecteurs accouplés LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU NOTE Cette caractéristique est calculée partir des mesures individuelles de paradiaphonie et la conformité du connecteur est obtenue par conformité aux exigences de paradiaphonie (6.5.6) 60603-7-7 © CEI:2010 – 53 – Toutes les paires: ≥ 68-20log (f) dB, de MHz 600 MHz Dès que l’exigence donne une valeur supérieure 50 dB, l'exigence doit revenir 50 dB 6.6 Caractéristiques mécaniques 6.6.1 Fonctionnement mécanique Voir 6.6.1 de la CEI 60603-7 6.6.2 Efficacité des dispositifs d’accouplement des connecteurs Voir 6.6.2 de la CEI 60603-7 6.6.3 Forces d’insertion et d’extraction Essais et programme d’essai 7.1 Généralités Voir 7.1 de la CEI 60603-7 7.2 Disposition pour l’essai de la résistance de contact Pour obtenir des informations utiles concernant les essais de résistance de contact, voir 7.2 de la CEI 60603-7-1 7.3 Disposition pour l’essai de vibration Pour obtenir des informations utiles concernant le principe des essais de vibration, voir 7.3 de la CEI 60603-7 7.4 Procédures d’essai et méthodes de mesure Voir 7.4 de la CEI 60603-7-1 7.5 Préconditionnement Voir 7.5 de la CEI 60603-7 7.6 7.6.1 Câblage et montage des spécimens Câblage Le câblage de ces connecteurs doit tenir compte du diamètre de fil et de câble, des câbles définis dans la série CEI 61156 selon ce qui est applicable d’après la spécification du fabricant 7.6.2 Montage Voir 7.6.2 de la CEI 60603-7-1 7.7 Programmes d’essais Les paramètres d’essai requis ne doivent pas être inférieurs ceux indiqués l’Article 7.7.1 Programme d’essais de base (minimal) Non applicable LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Voir 6.6.3 de la CEI 60603-7-1 60603-7-7 © CEI:2010 – 54 – 7.7.2 7.7.2.1 Programme d’essais complet Généralités En plus du programme d’essai de la CEI 60603-7 et de la CEI 60603-7-1, un groupe supplémentaire de deux jeux de connecteurs accouplés est exigé pour le groupe EP Les fiches pour le groupe EP doivent en plus satisfaire aux exigences de la CEI 60512-27-100 et de la CEI 60512-25-9 7.7.2.2 Groupe d’essais P – essais préliminaires Tous les spécimens du groupe d’essais doivent être soumis aux essais préliminaires du groupe P de la CEI 60603-7 et de la CEI 60603-7-1 7.7.2.3 Groupe d’essais AP 7.7.2.4 Groupe d’essais BP Voir 7.7.2.4 de la CEI 60603-7-1 et voir 7.7.2.4 de la CEI 60603-7-1 7.7.2.5 Groupe d’essais CP Voir 7.7.2.5 de la CEI 60603-7-1 et voir 7.7.2.5 de la CEI 60603-7-1 7.7.2.6 Groupe d’essais DP Voir 7.7.2.6 de la CEI 60603-7-1 et voir 7.7.2.6 de la CEI 60603-7-1 7.7.2.7 Groupe d’essais EP Tableau – Groupe d’essais EP Phase d’ essai EP1 Essai Titre CEI 60512 N° d’essai Mesure effectuer Sévérité ou condition d’essai Toutes les paires, une direction Titre Perte d'insertion CEI 60512 N° d’essai Essai 27a pour l’interface 60603-7-1 Exigences Selon 6.5.2 Future norme CEI pour l’interface 60603-7-7 EP EP EP EP EP Toutes les paires, dans les deux directions (paire paire) Paradiaphonie (NEXT) Toutes les paires, dans les deux directions Affaiblissement de réflexion Essai 27b pour l’interface 60603-7-1 Toutes les paires, dans les deux directions (paire paire) Télédiaphonie (FEXT) Essai 27d pour l’interface 60603-7-1 Toutes les paires, dans les deux directions TCL Toutes les paires, dans les deux directions TCTL Essai 27c pour l’interface 60603-7-1 Selon 6.5.6 Future norme CEI pour l’interface 60603-7-7 Selon 6.5.3 Future norme CEI pour l’interface 60603-7-7 Selon 6.5.8 Future norme CEI pour l’interface 60603-7-7 Essai 27f pour l’interface 60603-7-1 Selon 6.5.10 Future norme CEI pour l’interface CEI 60603-77 Essai 27g pour l’interface 60603-7-1 Future norme CEI pour l’interface CEI 60603-77 Selon 6.5.11 LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Voir 7.7.2.3 de la CEI 60603-7-1 et voir 7.7.2.3 de la CEI 60603-7-1 60603-7-7 © CEI:2010 Phase d’ essai EP7 EP8 – 55 – Essai Titre CEI 60512 N° d’essai Mesure effectuer Sévérité ou condition d’essai Résistance entrée / sortie en courant continu Points de mesure comme définis en 6.4.5 Résistance différentielle Points de mesure comme définis en 6.4.6 Titre CEI 60512 N° d’essai Exigences Méthode du niveau des millivolts Essai 2a Selon 6.4.5 Méthode du niveau des millivolts Essai 2a Selon 6.4.6 Tous les chemins d’entrées/sorties du connecteur Toutes les combinaisons entre entrées et sorties du connecteur Toutes les mesures doivent être réalisées sur les connecteurs accouplés NOTE Bien que la fiche accouplée puisse être différente, selon les exigences des normes d’essais, la même embase doit être utilisée pour chacun des essais 7.7.2.8 Groupe d’essais FP Voir 7.7.2.8 de la CEI 60603-7 7.7.2.9 Groupe d’essais GP Voir 7.7.2.9 de la CEI 60603-7-1 Pour la procédure d’évaluation de la continuité, le fonctionnement mécanique du dispositif de verrouillage, les exigences relatives aux calibres et les informations concernant le connecteur Keystone, les Annexes A, B, C et D de la CEI 60603-7 s’appliquent LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU NOTE – 56 – 60603-7-7 © CEI:2010 Bibliographie CEI 60512-26-100:2008, Connecteurs pour équipements électroniques – Essais et mesures – Partie 26-100: Montage de mesure, dispositifs d’essai et de référence et mesures pour les connecteurs conformes la CEI 60603-7 – Essais 26a 26g CEI 60603-7-51, Connecteurs pour équipements électroniques – Partie 7-51: Spécification particulière pour les fiches et les embases blindées voies pour la transmission de données des fréquences jusqu'à 000 MHz CEI 62153-4-12 : 2009, Méthodes d’essai des câbles métalliques de communication – Partie 4-12: Compatibilité Electromagnétique (CEM) – Affaiblissement d'écran et de couplage du matériel de connexion − Méthode de la pince absorbante (disponible en anglais seulement) _ _ A publier LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ISO/IEC 11801, Technologies de l'information – Câblage générique des locaux d’utilisateurs (disponible en anglais seulement) LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ELECTROTECHNICAL COMMISSION 3, rue de Varembé PO Box 131 CH-1211 Geneva 20 Switzerland Tel: + 41 22 919 02 11 Fax: + 41 22 919 03 00 info@iec.ch www.iec.ch LICENSED TO MECON LIMITED - RANCHI/BANGALORE, FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU INTERNATIONAL

Ngày đăng: 17/04/2023, 10:36

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN