1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 61784 5 10 2012 + a1 2015

24 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Nội dung

BS EN 61784-5-10:2012+A1:2015 BS EN 61784-5-10:2012 BSI Standards Publication Industrial communication networks — Profiles Part 5-10: Installation of fieldbuses — Installation profiles for CPF 10 BS EN 61784-5-10:2012+A1:2015 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 61784-5-10:2012+A1:2015 It is identical to IEC 61784-5-10:2010, incorporating amendment 1:2015 It supersedes BS EN 61784-5-10:2012 which is withdrawn The start and finish of text introduced or altered by amendment is indicated in the text by tags Tags indicating changes to IEC text carry the number of the IEC amendment For example, text altered by IEC amendment is indicated by  The UK participation in its preparation was entrusted to Technical Committee AMT/7, Industrial communications: process measurement and control, including fieldbus A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2015 Published by BSI Standards Limited 2015 ISBN 978 580 90355 ICS 25.040.40; 35.100.40 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2012 Amendments/corrigenda issued since publication Date Text affected 31 October 2015 Implementation of IEC amendment 1:2015 with CENELEC endorsement A1:2015 Annex ZA updated BS BS ENEN 61784-5-10:2012+A1:2015 61784-5-10:2012 61784-5-10 EN 61784-5-10:2012+A1 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM April 2012 2015 September ICS 25.040.40; 35.100.40 Supersedes EN 61784-5-10:2008 English version Industrial communication networks Profiles Part 5-10: Installation of fieldbuses Installation profiles for CPF 10 (IEC 61784-5-10:2010) Réseaux de communication industriels Profils Partie 5-10: Installation des bus de terrain Profils d'installation pour CPF 10 (CEI 61784-5-10:2010) Industrielle Kommunikationsnetze Profile Teil 5-10: Feldbusinstallation Installationsprofile für die Kommunikationsprofilfamilie 10 (IEC 61784-5-10:2010) This European Standard was approved by CENELEC on 2011-10-19 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 61784-5-10:2012 E EN 61784-5-10:2012 BS EN 61784-5-10:2012 EN 61784-5-10:2012 BS EN 61784-5-10:2012 EN 61784-5-10:2012 BS EN 61784-5-10:2012+A1:2015 EN 61784-5-10:2012 EN 61784-5-10:2012+A1:2015 -2-2-2-2–2– Foreword Foreword Foreword The text of document 65C/602/FDIS, future edition of IEC 61784-5-10, prepared by SC 65C, "Industrial Foreword The text of document 65C/602/FDIS, future edition of IEC 61784-5-10, prepared by SC 65C, "Industrial networks", IEC/TC 65, "Industrial-process measurement, and automation" to the The text of of document 65C/602/FDIS, future edition of IEC control 61784-5-10, prepared bywas SCsubmitted 65C, "Industrial networks", IEC/TC 65, "Industrial-process measurement, control and automation" to the The text of of document 65C/602/FDIS, futureby edition of IEC 61784-5-10, prepared bywas SCsubmitted 65C, "Industrial IEC-CENELEC parallel vote and approved CENELEC as control EN 61784-5-10:2012 networks", of IEC/TC 65, "Industrial-process measurement, and automation" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61784-5-10:2012 networks", of IEC/TC 65, "Industrial-process and automation" was submitted to the IEC-CENELEC parallel vote and approved bymeasurement, CENELEC as control EN 61784-5-10:2012 IEC-CENELEC parallel vote and approved by CENELEC as EN 61784-5-10:2012 The following dates are fixed: The following dates are fixed: The following dates are fixed: The following are fixed: (dop) 2012-10-20 • latest datedates by which the document has (dop) 2012-10-20 • latest date by which the document has to be implemented at national level by (dop) 2012-10-20 • to latest date by whichatthe document has be implemented national level by (dop) 2012-10-20 • publication latest date by which the document has of an identical national to be implemented at national level by publication of an identical national to be implemented at national level by standard or by endorsement publication identical national standard orof byan endorsement of an identical national (dow) 2014-10-19 • publication latest dateorby which the national standard by endorsement (dow) 2014-10-19 • standard latest dateorby the national bywhich endorsement standards conflicting with the (dow) 2014-10-19 • standards latest date conflicting by which the national with the (dow) 2014-10-19 • document latest date conflicting by which national have to bethe withdrawn standards with the document have to be withdrawn standards conflicting with the document have to be withdrawn document have to be withdrawn This document supersedes EN 61784-5-10:2008 This document supersedes EN 61784-5-10:2008 This document supersedes EN 61784-5-10:2008 This document standard issupersedes to be usedEN in 61784-5-10:2008 conjunction with IEC 61918, second edition (2010-07), together with the This standard is to be used in conjunction with IEC 61918, second edition (2010-07), together with the European Common Modification published with 61918:2008 This standard is to be used in conjunction withEN IEC 61918, second edition (2010-07), together with the European Common Modification published with EN 61918:2008 This standard is to be used in conjunction with IEC 61918, second edition (2010-07), together with the European Common Modification published with EN 61918:2008 European published with EN 61918:2008 Attention isCommon drawn toModification the possibility that some of the elements of this document may be the subject of Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for document identifying may any or all such patent Attention is drawn to the[and/or possibility that some of the elements of this beall thesuch subject of patent rights CENELEC CEN] shall not of bethe held responsible for document identifying may any or patent Attention is drawn to the possibility that some elements of this be the subject of rights patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights patent rights rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights EN 61784-5-10:2012/A1:2015 EN 61784-5-10:2012/A1:2015 Endorsement Endorsement notice notice Endorsement notice The text of the International Standard IEC 61784-5-10:2010 was approved by CENELEC as a European Endorsement notice EN 61784-5-10:2012/A1:2015 The text of the International Standard IEC 61784-5-10:2010 was approved by CENELEC as a European Standard without any modification EN 61784-5-10:2012/A1:2015 The text of the International Standard IEC 61784-5-10:2010 was approved by CENELEC as a European Standard without any modification The text of the International Standard IEC 61784-5-10:2010 was approved by CENELEC as a European Standard without any modification Standard without any modification In the official version, for Bibliography, the following note has to be added for the standard indicated: European foreword In the official version, for Bibliography, the following note has to be added for the standard indicated: In the official version, for Bibliography, the following note has to be added for the standard indicated: European foreword IEC/TRversion, 61158-1 NOTE Harmonized as CLC/TRnote 61158-1 In the official the following has to be added for the standard indicated: IEC/TR 61158-1 for Bibliography, NOTE Harmonized as CLC/TR 61158-1 IEC/TR 61158-1 European NOTE Harmonized as CLC/TRforeword 61158-1 61158-1 NOTE Harmonized as CLC/TR 61158-1 The textIEC/TR of document 65C/768/CDV, future IEC 61784-5-10:2010/A1, prepared by SC 65C "Industrial European foreword The text ofofdocument 65C/768/CDV, future IEC by SC 65C "Industrial networks" IEC/TC 65 "Industrial-process measurement, controlA1 andprepared automation" was submitted to Foreword to61784-5-10:2010/A1, amendment networks" of IEC/TC 65 "Industrial-process measurement, automation" was submitted to the IEC-CENELEC parallel vote and approved by CENELECcontrol as EN and 61784-5-10:2012/A1:2015 The text of document 65C/768/CDV, future IEC prepared by SC 65C "Industrial the IEC-CENELEC parallel vote and approved by61784-5-10:2010/A1, CENELEC as EN 61784-5-10:2012/A1:2015 networks" ofdocument IEC/TC 65 "Industrial-process measurement, control andprepared automation" was submitted to The text of 65C/768/CDV, future IEC 61784-5-10:2010/A1, by SC 65C "Industrial The following dates are fixed: the IEC-CENELEC parallel vote and approved by CENELEC as EN 61784-5-10:2012/A1:2015 networks" of IEC/TC 65 "Industrial-process measurement, control and automation" was submitted to The following dates are fixed: the IEC-CENELEC parallel vote and approved by CENELEC as EN 61784-5-10:2012/A1:2015 (dop) 2016-04-23 • latest date by which the document has to be implemented at The following dates are fixed: (dop) 2016-04-23 • latest date by by which the document has to be implemented at national level publication of an identical national The national followinglevel dates are fixed: of an identical national publication standard or byby endorsement (dop) 2016-04-23 • latest dateorby the document has to be implemented at standard bywhich endorsement national level by publication of an identical national (dop) 2016-04-23 •• latest has to beconflicting implemented (dow) 2018-07-23 latest date date by by which which the the document national standards with at standard or byby endorsement national level publication of an identical national (dow) 2018-07-23 • latest date by which the standards conflicting with the document have to benational withdrawn standard or byhave endorsement the document to be withdrawn (dow) 2018-07-23 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-07-23 • latest date by which the national standards conflicting with the document have to be withdrawn Attention is drawn to the possibility that some of the elements of this document may be the subject of Attention is drawn to the possibility that some of the of this document may be theorsubject of patent rights CENELEC [and/or CEN] shall not be elements held responsible for identifying any all such patent rights rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights patent rights CENELEC [and/or CEN] shall not be elements held responsible for identifying any all such Attention is drawn to the possibility that some of the of this document may be theorsubject of patent rights rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights Endorsement notice Endorsement notice Endorsement notice The text of the International Standard Endorsement IEC 61784-5-10:2010/A1:2015 notice The text of the International IEC 61784-5-10:2010/A1:2015 a European Standard withoutStandard any modification a European Standard without any modification The text of the International Standard IEC 61784-5-10:2010/A1:2015 a European Standard withoutStandard any modification The text of the International IEC 61784-5-10:2010/A1:2015 a European Standard without any modification was approved by CENELEC as was approved by CENELEC as was approved by CENELEC as was approved by CENELEC as (normative) Annex ZA BS EN 61784-5-10:2012+A1:2015 (normative) Annex Normative references to– 3international publications – ZA EN 61784-5-10:2012+A1:2015 BS EN 61784-5-10:2012 (normative) with their corresponding - -European publications EN 61784-5-10:2012 Normative references to international publications with their references corresponding European publications Normative to international publications Annex ZA with their corresponding Europeanreferenced publications The following documents, in whole or in part, are normatively in this document and are (normative) indispensable for its application For dated references, only the edition cited applies For undated references, thedocuments, latest edition the referenced (including any amendments) applies and are Normative references to publications The following inofwhole or in part,document areinternational normatively referenced in this document indispensable for itswith application For dated references, only thepublications edition cited applies For undated their corresponding European NOTE When an International Publication has been by common indicated by (mod), The following inofwhole or in part, are modified normatively referenced in this document are references, thedocuments, latest edition the referenced document (including any modifications, amendments) applies and the relevant EN/HD indispensable for applies its application For dated references, only the edition cited applies For undated The following referenced documents are indispensable for the application of this document For dated references, thedocuments, latest editioninofwhole the referenced document (including any modifications, amendments) applies.by The or in For part, are normatively referenced this document and are NOTEfollowing When an International has been modified by common indicated (mod), references, only the edition citedPublication applies undated the Standards latestin edition NOTE Up-to-date information on the latest versions ofreferences, the European listedofin the thisreferenced annex is the relevant EN/HD applies indispensable for its application For dated references, only the edition cited applies For undated document (including any amendments) applies available www.cenelec.eu NOTE here: When an International has been modified (including by commonany modifications, indicated by (mod), references, the latest edition ofPublication the referenced document amendments) applies the relevant EN/HD applies NOTEWhen Up-to-date information latest versions of themodifications, European Standards annex is NOTE an international publication on hasthe been modified by common indicated by listed (mod), in thethis relevant EN/HD NOTE 1  here: When an International Publication has been modified by common modifications, indicated by (mod), available www.cenelec.eu applies NOTE Up-to-date information on the latest versions of the European Standards listed in this annex is the relevant EN/HD applies available here: www.cenelec.eu Publication Year Title Title EN/HD Year Publication Year EN/HD Year NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available IEC 61918here: www.cenelec.eu 2010 Industrial communication networks - Replacement in Annex ZA of EN 61784-5-10:2012: Publication Year Title Installation of communication networks in industrial premises IEC 61918 (mod) 2013 Industrial communication networks Publication Year Title Replacement in Annex ZA ofInstallation EN 61784-5-10:2012: of communication networks in industrial premises IEC 61918 (mod) 2013 communication networks Replacement in Annex ZA ofIndustrial EN 61784-5-10:2012: Installation of communication networks in -IEC 61918to(mod) -2013 Industrial communication networks Addition Annex ZA of EN 61784-5-10:2012: industrial premises Installation of communication networks in IEC 60793-2-50 -Optical fibres industrial premises Addition to Annex ZA of EN 61784-5-10:2012: Part 2-50: Product specifications Sectional specification for class B singleIEC 60793-2-50 - of EN 61784-5-10:2012: Optical fibres Addition to Annex ZA mode fibres Part 2-50: Product specifications IEC 60793-2-50 Optical fibres Sectional specification for class B singlePart 2-50: Product specifications mode fibres Sectional specification for class B singlemode fibres EN/HD Year EN 61918 EN/HD 2013 Year + AC EN 61918 2014 2013 + AC EN 61918 2014 2013 + AC EN 60793-2-50 -2014 EN 60793-2-50 - EN 60793-2-50 - 3 BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 –4– –2– BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) CONTENTS INTRODUCTION Scope .6 Normative references .6 Terms, definitions and abbreviated terms CPF 10: Overview of installation profiles Installation profile conventions 6 Conformance to installation profiles Annex A (normative) CP 10/1 (Vnet/IP™) specific installation profile Bibliography 19 Figure – Standards relationships Table A.1 – Network characteristics for balanced cabling based on Ethernet 10 Table A.2 – Network characteristics for optical fibre cabling 10 Table A.3 – Information relevant to copper cable: fixed cables 11 Table A.4 – Information relevant to copper cable: cords 12 Table A.5 – Information relevant to optical fibre cables 12 Table A.6 – Connectors for balanced cabling CPs based on Ethernet 13 Table A.7 – Optical fibre connecting hardware 14 13 BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 –5– BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) –5– INTRODUCTION This International Standard is one of a series produced to facilitate the use of communication networks in industrial control systems IECIEC 61918:2010 provides the common requirements for for thetheinstallation  61918:2013  provides the common requirements installationofof communication communication networks ininindustrial industrial control systems This installation profile standard provides the networks control systems This installation profile standard provides the installation installation profiles of the communication profiles (CP)communication of a specific communication profile profiles of the communication profiles (CP) of a specific profile family (CPF) by family (CPF) stating which of IEC 61918 apply and, where necessary, by stating which by requirements of requirements IEC 61918 fully apply and, fully where necessary, by supplementing, modifying, or replacing the other requirements (seerequirements Figure 1) supplementing, modifying, or replacing the other (see Figure 1) For general background on fieldbuses, their profiles, and relationship between the installation profiles specified in this standard, see IEC/TR 61158-1 Each CP installation profile is specified in a separate annex of this standard Each annex is structured exactly as the reference standard IEC 61918 for the benefit of the persons representing the roles in the fieldbus installation process as defined in IEC 61918 (planner, installer, verification personnel, validation personnel, maintenance personnel, administration personnel) By reading the installation profile in conjunction with IEC 61918, these persons immediately know which requirements are common for the installation of all CPs and which are modified or replaced The conventions used to draft this standard are defined in Clause The provision of the installation profiles in one standard for each CPF (for example IEC 61784-5-10 for CPF 10), allows readers to work with standards of a convenient size PLANNING AND INSTALLATION DESIGN ISO/IEC 11801 Offices Annex HOMES ISO/IEC 15018 Home Annex DATA CENTRES ISO/IEC 24764 OFFICE PREMISES GENERIC CABLING BETWEEN AUTOMATION ISLANDS INDUSTRIAL PREMISES BETWEEN AUTOMATION ISLANDS WITHIN AUTOMATION ISLANDS ISO/IEC 14763-2 Data centre Annex Industrial Annex ISO/IEC 24702 IEC 61158 series and IEC 61784-1, -2 Installation Profiles IEC 61918 IEC 61784-5 series (Selection + Add/Repl/Mod) APPLICATION-SPECIFIC CABLING Figure – Standards relationships (Common requirements) Common structure BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 –6– –6– –6– BS EN 61784-5-10:2012 BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) 61784-5-10 © IEC:2010(E) BS EN 61784-5-10:2012 NETWORKS – © IEC:2010(E) 61784-5-10 INDUSTRIAL COMMUNICATION –6– INDUSTRIAL COMMUNICATION NETWORKS – PROFILES – PROFILES – INDUSTRIAL COMMUNICATION NETWORKS – Part 5-10: Installation PROFILESof– fieldbuses – PartInstallation 5-10: Installation fieldbuses profilesoffor CPF 10 – Installation profiles for CPF 10 Part 5-10: Installation of fieldbuses – Installation profiles for CPF 10 1 Scope Scope This part of IEC 61784 specifies the installation profile for CPF 10 (Vnet/IP™) 1 Scope This part of IEC 61784 specifies the installation profile for CPF 10 (Vnet/IP™) The installation profile is in This installation profilespecifies is specified specified in the annex This part of IEC 61784 the installation profile for   is specified in the annex This TheIEC 61918:2013 installation profile IEC 61918:2010 IEC 61918:2010 The installation profile is specified in the annex This IEC Normative 61918:2010.references 2 read in in conjunction with annex read with 1conjunction CPF 10 is(Vnet/IP™) annex is read in conjunction with annex is read in conjunction with Normative references The following referenced documents are indispensable for the application of this document Normative references The following referenced for the application this document For dated references, onlydocuments the edition are citedindispensable applies For undated references,ofthe latest edition For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies The referenced documents the application of this document of thefollowing referenced document (including are any indispensable amendments) for applies For dated references, only the edition cited applies For undated references, the latest edition  IEC 60793-2-50, Optical fibres – Partany 2-50: Product –specifications – Sectional specification for IEC 61918:2010, Industrial communication networks Installation communication networks of the referenced document (including amendments) applies of IEC 61918:2010, Industrial class B single-mode fibrescommunication networks – Installation of communication networks in industrial premises in industrial premises IECIEC 61918:2010, Industrial communication networks – Installation ofofcommunication  61918:2013 , Industrial networks Installation communication networks networks The normative references of IECcommunication 61918:2010, Clause 2, –apply in industrial industrial premises in premises The normative references of IEC 61918:2010, Clause 2, apply The normative references IEC 61918:2013terms , Clause 2, apply normative referencesof of IEC 61918:2010, Clause 2, apply Terms, definitions and abbreviated Terms, definitions and abbreviated terms For the purposes of this the terms terms, definitions and abbreviated terms of Terms, definitions anddocument, abbreviated For 61918:2010, the purposes of this document, the specific terms, terms, definitions and abbreviated terms of IEC Clause 3, apply For profile definitions and abbreviated terms IEC Clause 61918:2010, A.3 Clause 3, apply For profile specific terms, definitions and abbreviated terms see For purposes this document, document, the the terms, terms, definitions definitions and abbreviated abbreviated terms of the purposes of this A.3 see Clause  61918:2013 , Clause 3, apply For profile definitions and abbreviated IECIEC 61918:2010, Clause 3, apply For profile specificspecific terms, terms, definitions and abbreviated terms terms see 10: Clause A.3 A.3 see CPF Clause Overview of installation profiles CPF 10: Overview of installation profiles CPF 10 consists of one communication profile as specified in IEC 61784-2 CPF 10: Overview of installation profiles CPF 10 consists of one communication profile as specified in IEC 61784-2 The for CP 10/1 (Vnet/IP™) are specified in Annex A CPF installation 10 consistsrequirements of one communication profile as specified in IEC 61784-2 The installation requirements for CP 10/1 (Vnet/IP™) are specified in Annex A The installation requirements for CP 10/1 (Vnet/IP™) are specified in Annex A Installation profile conventions Installation profile conventions The numbering of profile the clauses and subclauses in the annexes of this standard Installation conventions Thenumbering numberingofofIEC the 61918 clauses andclauses subclauses in the annexes of this standard the main and subclauses the numbering of IEC 61918 main clauses and subclauses The numbering of the clauses and subclauses in the annexes of this standard The annex clauses subclauses of this standard supplement, modify, the numbering of IEC and 61918 main clauses and subclauses The annexclauses clausesand and subclauses of this standard supplement, modify, respective subclauses in IEC 61918 respective clauses and subclauses in IEC 61918 The annex clauses and subclauses of this standard supplement, modify, respective clauses and subclauses in IEC 61918 _ _ corresponds to corresponds to corresponds to or replace the or replace the or replace the Vnet/IP™ is a trade name of Yokogawa Electric Corporation This information is given for the convenience of users of this International and does not Corporation constitute anThis endorsement by isIEC of the holder or Vnet/IP™ is a trade nameStandard of Yokogawa Electric information given for trademark the convenience of _ any products Compliance to this not require use of the by trade of the usersofofitsthis International Standard andstandard does not does constitute an endorsement IECname of theVnet/IP™ trademarkUse holder or requires permission of Yokogawa Electric Corporation trade any ofname its products to this standard does not require use of the trade namefor Vnet/IP™ Use of the Vnet/IP™ isVnet/IP™ a tradeCompliance name of Yokogawa Electric Corporation This information is given the convenience of trade name requires permission of Yokogawa Electric Corporation by IEC of the trademark holder or users of thisVnet/IP™ International Standard and does not constitute an endorsement any of its products Compliance to this standard does not require use of the trade name Vnet/IP™ Use of the trade name Vnet/IP™ requires permission of Yokogawa Electric Corporation –7– BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 –7– Where there is no corresponding subclause of IEC 61918 in the normative annexes in this standard, the subclause of IEC 61918 applies without modification The annex heading letter represents the installation profile assigned in Clause The annex (sub)clause numbering following the annex letter shall represent the corresponding (sub)clause numbering of IEC 61918 EXAMPLE “Annex B.4.4” in IEC 61784-5-3 means that CP 3/2 specifies the Subclause 4.4 of IEC 61918 All main clauses of IEC 61918 are cited and apply in full unless otherwise stated in each normative installation profile annex If all subclauses of a (sub)clause are omitted, then the corresponding IEC 61918 (sub)clause applies If in a (sub)clause it is written “Not applicable”, then the corresponding IEC 61918 (sub)clause does not apply If in a (sub)clause it is written “Addition”, then the corresponding IEC 61918 (sub)clause applies with the additions written in the profile If in a (sub)clause it is written “Replacement”, then the text provided in the profile replaces the text of the corresponding IEC 61918 (sub)clause NOTE A replacement can also comprise additions If in a (sub)clause it is written “Modification”, then the corresponding IEC 61918 (sub)clause applies with the modifications written in the profile If all (sub)clauses of a (sub)clause are omitted but in this (sub)clause it is written “(sub)clause x has addition:” (or “replacement”) or is “(Sub)clause x is not applicable.”, then (sub)clause x becomes valid as declared and all the other corresponding IEC 61918 (sub)clauses apply Conformance to installation profiles installationprofile profilewithin within this standard includes ofIEC IEC61918:2013 61918:2010 Each installation this standard includes part part of  .ItIt may may also include defined definedadditional additionalspecifications specifications include A statement of compliance to an installation profile of this standard shall be stated as either and for CPAm.1 10/1for or or Compliance to IEC 61784-5-10:2010  Compliance to IEC 61784-5-10:2010 CP 10/m Compliance and for CP 10/m  Compliance to to IEC IEC61784-5-10 61784-5-10(Ed.2.0 (Ed.2.0) forAm.1) CP 10/1 where the name within the angle brackets < > is optional and the angle brackets are not to be included NOTE The name may be the name of the profile, for example Vnet/IP If the name is a trade name then the permission of the trade name holder shall be required Product standards shall not include any conformity assessment aspects (including quality management provisions), neither normative nor informative, other than provisions for product testing (evaluation and examination) _ In accordance with ISO/IEC Directives The date should not be used when the edition number is used BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 –8– –8– BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) Annex A (normative) CP 10/1 (Vnet/IP™) specific installation profile A.1 Installation profile scope Addition: This standard specifies the installation profile for for Communication Profile CP 10/1 (Vnet/IP) The CP 10/1 is specified in IEC 61784-2 A.2 Normative references A.3 Installation profile terms, definitions, and abbreviated terms A.3.1 Terms and definitions Addition: A.3.1.1 Repeater HUB concentrator device such as 1000BASE-T common type HUB A.3.2 Abbreviated terms A.3.3 Conventions for installation profiles Not applicable A.4 Installation planning A.4.1 Introduction A.4.1.1 Objective A.4.1.2 Cabling in industrial premises A.4.1.3 The planning process A.4.1.4 Specific requirements for CPs Not applicable –9– BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) A.4.1.5 A.4.2 A.4.2.1 BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 –9– Specific requirements for generic cabling in accordance with ISO/IEC 24702 Planning requirements Safety A.4.2.1.1 General A.4.2.1.2 Electrical safety A.4.2.1.3 Functional safety Not applicable A.4.2.1.4 Intrinsic safety Not applicable A.4.2.1.5 Safety of optical fibre communication systems Not applicable A.4.2.2 Security Addition: The automation island network shall be isolated from the office environment and the internet, provided however, if the planner provides appropriate security through the use of gateways, firewalls, routers and/or appropriate security software, this shall not apply Careful consideration should be given to the placement of ports to prevent unauthorized connection of devices into the automation island network Cabling components should be protected from damage by machinery or tampering A.4.2.3 Environmental considerations and EMC A.4.2.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 A.4.3 A.4.3.1 Network capabilities Network topology A.4.3.1.1 Common description A.4.3.1.2 Basic physical topologies for passive networks Not applicable A.4.3.1.3 Basic physical topologies for active networks A.4.3.1.4 Combination of basic topologies A.4.3.1.5 Specific requirements for CPs Addition: Redundant network, network,which whichhas has any topology specified inIEC IEC61918:2013 61918:2010, Redundant any topology specified in  ,4.3.1.3, 4.3.1.3, shall shall be used BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 10 – BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) – 10 – A.4.3.1.6 A.4.3.2 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Network characteristics A.4.3.2.1 General A.4.3.2.2 Network characteristics for balanced cabling not based on Ethernet Not applicable A.4.3.2.3 Network characteristics for balanced cabling based on Ethernet Replacement: Table the template given in  IEC 61918:2010, 61918:2013 , Table Table A.1 A.1provides providesvalues valuesbased basedonon the template given in IEC Table 2 Table A.1 – Network characteristics for balanced cabling based on Ethernet Characteristics CP 10/1 Supported data rates (Mbit/s) 100/1 000 Supported channel length (m) b 100 Number of connections in the channel (max.) a b Patch cord length (m) 80 Channel class per ISO/IEC 24702 (min.) a D Cable category per ISO/IEC 24702 (min.) b Connecting HW category per ISO/IEC 24702 c Cable types Application dependent a See See IECA.4.4.3.2. 61918, 4.4.3.2 b For the purpose of this table the channel definitions of ISO/IEC 24702 are applicable c For additional information see IEC 61156 series A.4.3.2.4 Network characteristics for optical fibre cabling Replacement: –4– IEC 61784-5-10:2010/AMD1:2015 Table the template given in  IEC 61918:2010, 61918:2013 , Table Table A.2 A.2provides providesvalues valuesbased basedonon the template given in IEC Table 3  IEC 2015  Table A.2 – Network characteristics for optical fibre cabling CP 10/1 Optical fibre Optical type fibre type Description Description Single mode silica Standard Single mode silica a A.4.4.1.4 Bandwidth (MHz) or 200 at 310 equivalent at λ (nm) Attenuation coefficient at 310 nm 0,5 dB/km Minimum length (m) Bandwidth or equivalent at 310 nm 200 MHz × km Maximum length a (m) 000 Alternative description Maximum channel 10 Mode field diameter (μm) loss/optical power Insertion budget (dB) 125 Outer diameter (μm) Connecting hardware See A.4.4.2.5 Minimum length (m) This value is reduced by connections, splices and bends in accordance with formula (1) in 4.4.3.4.1 of IEC 61918:2013 Optical fibre cables  BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 11 – – 11 – Maximum length (m) A.4.3.2.5 000 Specific network characteristics Addition: Any repeater HUB shall not be used for CPF 10/1 network A.4.3.2.6 A.4.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Selection and use of cabling components A.4.4.1 Cable selection A.4.4.1.1 Common description A.4.4.1.2 Copper cables A.4.4.1.2.1 Copper cables for Ethernet based CPs Replacement: Table the template given in  IEC 61918:2010, 61918:2013 , Table Table A.3 A.3provides providesvalues valuesbased basedonon the template given in IEC Table 4 Table A.3 – Information relevant to copper cable: fixed cables Characteristic CP 10/1 Nominal impedance of cable (tolerance) 100 Ω ± 15 Ω DCR of conductors < 9,38 Ω/100 m DCR of shield < 62,5/D Ω/km where D is the outside diameter of the shield (mm) Number of conductors Shielding UTP Colour code for conductor WH/OG, OG, WH/GN, BU, WH/BU, GN, WH/BN, BN Jacket colour requirements —a Jacket material Application dependent Resistance to harsh environment (e.g UV, oil Application dependent resist, LS0H) Agency ratings No requirement Other characteristics — a See A.4.4.6.3 Replacement: Table the template given in  IEC 61918:2010, 61918:2013 , Table Table A.4 A.4provides providesvalues valuesbased basedonon the template given in IEC Table 5 BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 12 – BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) – 12 – Table A.4 – Information relevant to copper cable: cords Characteristic CP 10/1 Nominal impedance of cable (tolerance) 100 Ω ± 15 Ω DCR of conductors < 9,38 Ω/100 m DCR of shield < 62,5/D Ω/km where D is the outside diameter of the shield (mm) Number of conductors Length 100 Shielding UTP –4– Colour code for conductor A.2 – Network JacketTable colour requirements IEC 61784-5-10:2010/AMD1:2015  IEC 2015 WH/OG, OG, WH/GN, BU, WH/BU, GN, WH/BN, BN characteristics — fora optical fibre cabling Jacket material Application dependent CP 10/1 Resistance to harsh environment (e.g UV, oil Application dependent Optical fibre type Description resist, LS0H) Single mode silica Agency ratings a See A.4.4.6.3 A.4.4.1.2.2 Bandwidth (MHz) or No requirement 200 at 310 equivalent at λ (nm) Minimum length (m) Maximum length a (m) 000 Copper cables for Maximum non Ethernet channel based CPs Insertion loss/optical power budget (dB) Not applicable Connecting hardware See A.4.4.2.5 A.4.4.1.3 Cable for wireless installation a requirements This value is reduced by connections, splices and bends in A.4.4.1.4 Optical fibre cables accordance with formula (1) in 4.4.3.4.1 of IEC 61918:2013 Replacement: A.4.4.1.4 Optical fibre cables Table A.5 A.5the provides values based the template given in IEC Table 6 Table provides values based onon the template given in  IEC 61918:2010, 61918:2013 , Table Replace existing Table A.5 with the following Table A.5: Table A.5 – Information relevant to optical fibre cables Characteristics Characteristic Standard Attenuation per km (650 nm) 50/125 50/125 μm µm multimode multimode silica silica 62,5/125 μm step 000 000 μm µm200/230 62,5/125 µm980/1 980/1 200/230 µm μm hard clad stepstep index multimode index index step index silicaclad POFPOF multimode silica hard silica silica IEC — 60793-2-50 Type B1.1 — – — – — – — – – — – — – — – — – 10/125 µm μm 10/125 singlemode mode single silica silica Attenuation per km per km Attenuation (650 nm) (820 nm) — Attenuation per km per km Attenuation (820 nm) (1 310 nm) – 0,5 dB/km — – — – — – — – Number of optical Attenuation per km (1 310 nm) fibres ≤ 0,5 dB — – — – — – — – NumberConnector of optical fibres type (duplex or simplex) Jacket colour Jacket colour requirements requirements Jacket material Jacket material SC Duplex, LC a —a — – — – — – — – Resistance to harsh Resistance to oil environment (e.g UV, resist, LS0H) harsh environment UV, oil resist, a See (e.g A.4.4.6.3 A.4.4.2.2 Application dependent Application dependent Application Application dependent dependent — — — – – – — — — – – – — — — – – – — — — Connecting hardware for balanced cabling CPs based on Ethernet – – –  single mode silica silica LS0H) LS0H) Breakout Breakout a See A.4.4.6.3 a See A.4.4.6.3 Yes Yes multimode silica silica — — μm multimode multimode silica silica – 13 – — — step index POF POF indexsilica hard clad silica BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 — — — — A.4.4.1.5 A.4.4.1.5 Special purpose balanced and optical fibre cables Special purpose balanced and optical fibre cables A.4.4.1.6 A.4.4.1.6 Specific cable requirements for CPs Specific cable requirements for CPs Not applicable Not applicable A.4.4.1.7 A.4.4.1.7 A.4.4.2 A.4.4.2 Specific requirements for generic cabling in accordance with Specific requirements for generic cabling in accordance with ISO/IEC 24702 ISO/IEC 24702 Connecting hardware selection Connecting hardware selection A.4.4.2.1 A.4.4.2.1 Common description Common description A.4.4.2.2 A.4.4.2.2 Connecting hardware for balanced cabling CPs based on Ethernet Connecting hardware for balanced cabling CPs based on Ethernet Replacement: Replacement: IEC 61784-5-10:2010/AMD1:2015 –5– Table A.6 A.6provides providesvalues valuesbased basedonon the template given in IEC Table 7 Table the template given in  IEC 61918:2010, 61918:2013 , Table  IECA.6 2015 Table provides values based on the template given in IEC 61918:2010, Table Table Table A.6 A.6 –– Connectors Connectors for for balanced balanced cabling cabling CPs CPs based based on on Ethernet Ethernet Table A.6 – Connectors for balanced cabling CPs based on Ethernet IEC 60603-7 series a IEC 60603-7-x a IEC 60603-7-x a shielded unshielded IEC 61076-3-106 b IEC 61076-3-117 b IEC 61076IEC 61076IEC 61076-3-106 IEC 61076-3-117 IEC 61076-2-101 2-101 2-109 b b IEC 61076-3-106 IEC 61076-3-117 IEC 61076-2-101 b b Var Var Var 14 M12-4 with M12-8 with M12-4 with D-coding X-coding M12-4 with (shielded) (unshielded) Variant Variant Variant 14 D-coding (shielded) (unshielded) Variant 6No Variant 14 No D-coding CP Yes Yes No VariantNo No CP 10/1 Yes Yes No No No No 10/1 CP 10/1 Yes Yes No No No No aa For IEC 60603-7-x the connector selection is based on the desired channel performance For IEC IEC 60603-7-x 60603-7 series, the connector selection is based on the desired channel performance a For the connector selection is based on the desired channel performance b Housings to protect connectors bb Housings Housings to to protect protect connectors connectors A.4.4.2.3 Connecting hardware for copper cabling CPs not based on Ethernet A.4.4.2.3 Connecting hardware for copper cabling CPs not based on Ethernet A.4.4.9.5 Cable routing outside buildings Not applicable Not applicable Replace the existing title of A.4.4.9.5 with the following title: A.4.4.2.4 Connecting hardware requirements for wireless installation A.4.4.2.4 hardware for wireless installation Cable routingConnecting outside and betweenrequirements buildings A.4.4.2.5 Optical fibre connecting hardware A.4.4.2.5 Optical fibre connecting hardware Replacement: Replacement: _ BS EN 61784-5-10:2012 Table A.7 provides values based on the template given in IEC 61918:2010, Table – 14 – 61784-5-10 © IEC:2010(E) Table the template given in  IEC 61918:2010, 61918:2013 , Table Table A.7 A.7provides providesvalues valuesbased basedonon the template given in IEC Table Table A.7 – Optical fibre connecting hardware IEC 61754-2 IEC 61754-4 IEC 61754-24 IEC 61754-20 IEC 61754-22 BFOC/2,5 SC SC-RJ LC F-SMA No Yes No Yes No CP 10/1 Others No NOTE IEC 61754 series defines the optical fibre connector mechanical interfaces; performance specifications for optical fibre connectors terminated to specific fibre types are standardised in IEC 61753 series A.4.4.2.6 Specific requirements for CPs Not applicable A.4.4.2.7 A.4.4.3 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Connections within a channel/permanent link  BFOC/2,5 SC SC-RJ LC F-SMA 10/1 No Yes No Yes No BSCP EN 61784-5-10:2012+A1:2015 – 14 – IEC 61784-5-10:2012+A1:2015 NOTE IEC 61754 series defines the optical fibre connector mechanical interfaces; performance No specifications for optical fibre connectors terminated to specific fibre types are standardised in IEC 61753 series A.4.4.2.6 Specific requirements for CPs Not applicable A.4.4.2.7 Specific requirements for generic cabling in accordance with ISO/IEC 24702 A.4.4.3 Connections within a channel/permanent link A.4.4.4 Terminators Not applicable A.4.4.5 Device location and connection A.4.4.5.1 Common description A.4.4.5.2 Specific requirements for CPs Not applicable A.4.4.5.3 Specific requirements for wireless installation A.4.4.5.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 A.4.4.6 Coding and labelling A.4.4.6.1 Common description A.4.4.6.2 Additional requirements for CPs A.4.4.6.3 Specific requirements for CPs Addition: The planner shall request to use redundancy cables of different colours and identify each of the two cables with labelling A.4.4.6.4 A.4.4.7 Specific requirements for generic cabling cabling in accordance with ISO/IEC 24702 Earthing and bonding of equipment and devices and shielded cabling A.4.4.7.1 Common description A.4.4.7.2 Bonding and earthing of enclosures and pathways A.4.4.7.3 Earthing methods A.4.4.7.4 Shield earthing – 15 – BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) A.4.4.7.5 BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 15 – Specific requirements for CPs Addition: If a device has a direct connection to earth at the communications port, then the cable shield shall be opened at the device end A.4.4.7.6 Specific requirements for generic cabling in accordance with ISO/IEC 24702 A.4.4.8 Storage and transportation of cables A.4.4.9 Routing of cables A.4.4.9.1 Common description A.4.4.9.2 Cable routing of assemblies A.4.4.9.3 Detailed requirements for cable routing inside enclosures A.4.4.9.4 Cable routing inside buildings A.4.4.9.5  Cable routing outside and between buildings Cable routing outside buildings A.4.4.9.6 Installing redundant communication cables Addition: See also the requirements described in A.4.4.6.3 for cables used for redundancy A.4.4.10 Separation of circuits A.4.4.11 Mechanical protection of cabling components A.4.4.11.1 Common description A.4.4.11.2 Specific requirements for CPs Not applicable A.4.4.11.3 A.4.4.12 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Installation in special areas A.4.4.12.1 Common description A.4.4.12.2 Specific requirements for CPs Not applicable BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 16 – – 16 – A.4.4.12.3 A.4.5 BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) Specific requirements for generic cabling in accordance with ISO/IEC 24702 Cabling planning documentation A.4.5.1 Common description A.4.5.2 Cabling planning documentation for CPs A.4.5.3 Network certification documentation A.4.5.4 Cabling planning documentation for generic cabling in accordance with ISO/IEC 24702 A.4.6 A.5 Verification of cabling planning specification Installation implementation A.5.1 General requirements A.5.2 Cable installation A.5.2.1 General requirements for all cabling types A.5.2.2 Installation and routing A.5.2.3 Specific cable installation requirements for CPs Not applicable A.5.2.4 Specific requirements for wireless installation A.5.2.5 Specific requirements for generic cabling in accordance with ISO/IEC 24702 A.5.3 Connector installation A.5.3.1 Common description A.5.3.2 Shielded connectors A.5.3.3 Unshielded connectors Not applicable A.5.3.4 Specific requirements for CPs Not applicable A.5.3.5 Specific requirements for wireless installation A.5.3.6 Specific requirements for generic cabling in accordance with ISO/IEC 24702 A.5.4 Terminator installation Not applicable A.5.4.1 Common description A.5.4.2 Specific requirements for CPs Not applicable – 17 – BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) A.5.5 BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 17 – Device installation A.5.5.1 Common description A.5.5.2 Specific requirements for CPs Not applicable A.5.6 Coding and labeling A.5.6.1 Common description A.5.6.2 Specific requirements for CPs Addition: The installer shall use redundancy cables of different colours and identify each of the two cables with labelling (see A.4.4.6.3 of this standard) A.5.7 Earthing and bonding of equipment and devices and shield cabling A.5.7.1 Common description A.5.7.2 Bonding and earthing of enclosures and pathways A.5.7.3 Earthing methods A.5.7.4 Shield earthing methods A.5.7.5 Specific requirements for CPs Addition: If a device has a direct connection to earth at the communications port, then the cable shield shall be opened at the device end A.5.7.6 A.5.8 A.6 Specific requirements for generic cabling in accordance with ISO/IEC 24702 As-implemented cabling documentation Installation verification and installation acceptance test A.6.1 Introduction A.6.2 installation verification A.6.2.1 General A.6.2.2 Verification according to cabling planning documentation A.6.2.3 Verification of earthing and bonding A.6.2.4 Verification of shield earthing A.6.2.5 Verification of cabling system A.6.2.6 Cable selection verification A.6.2.6.1 Common description BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 18 – – 18 – A.6.2.6.2 BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) Specific requirements for CPs Not applicable A.6.2.6.3 Specific requirements for wireless installation A.6.2.7 Connector verification A.6.2.7.1 Common description A.6.2.7.2 Specific requirements for CPs Not applicable A.6.2.7.3 Specific requirements for wireless installation A.6.2.8 Connection verification A.6.2.9 Terminators verification Not applicable A.6.2.10 Coding and labelling verification A.6.2.10.1 Common description A.6.2.10.2 Specific coding and labelling verification requirements Addition: It shall be confirmed that two cables for redundancy are labelled for discrimination A.6.2.11 A.6.3 Verification report Installation acceptance test A.6.3.1 General A.6.3.2 Acceptance test of Ethernet based cabling A.6.3.3 Acceptance test of non Ethernet based cabling Not applicable A.6.3.4 Specific requirements for wireless installation A.6.3.5 Acceptance test report A.7 Installation administration Subclause 7.8 is not applicable A.8 Installation maintenance and installation troubleshooting Subclause 8.4 is not applicable – 19 – BS EN 61784-5-10:2012 61784-5-10 © IEC:2010(E) BS EN 61784-5-10:2012+A1:2015 IEC 61784-5-10:2012+A1:2015 – 19 – Bibliography Addition: [1] IEC/TR 61158-1, Industrial communication networks – Fieldbus specifications – Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series This page deliberately left blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 15/04/2023, 10:23

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN