Hướng dẫn sử dụng EC20 series PLC

51 752 6
Hướng dẫn sử dụng  EC20 series PLC

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Hướng dẫn sử dụng

EC20 Series PLC User Manual Version V1.1 Revision date June 26, 2006 BOM 31011166 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Copyright © 2005 by Emerson Network Power Co., Ltd. All rights reserved. The contents in this document are subject to change without notice. Emerson Network Power Co., Ltd. Address: No.1 Kefa Rd., Science & Industry Park, Nanshan District 518057, Shenzhen China Homepage: www.emersonnetworkpower.com.cn E-mail: support@emersonnetwork.com.cn Safety Precautions To reduce the chance of accident, please read the safety precautions very carefully before operation. The "Caution, Notice, Warning, Danger" symbols in this manual do not represent all the safety points to be observed, and are only used as a supplement to various operation safety points. Therefore, the installation and operation personnel must be strictly trained and master the correct operations and all the safety points before actual operation. When operating Emerson PLC products, the safety rules in the industry, the general safety points and special safety instructions specified in this manual must be strictly observed. These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger: Danger: indicates that death, severe personal injury, or substantial property damage will result if proper precautions are not taken. Warning: indicates that death, severe personal injury, or substantial property damage could possibly result if proper precautions are not taken. Caution: indicates that minor personal injury or property damage can result if proper precautions are not taken. Notes for designing The programming must include safety circuit to ensure the safe application of the PLC (Programmable Logic Controller) system upon power off or the PLC malfunction. Note the following when programming: z The external circuit of the PLC must include the emergency braking circuit, protection circuit, mutual interlock circuit of forward/reverse rotation, and the interlock switch of position upper/lower limit for preventing equipment from damage. z For the safe operation of the equipment and output signals of the serious accident, please design the external protection circuit and the safety mechanism. z All the outputs may be shutdown when the CPU of the PLC detects the abnormity of the system; the failure of part PLC circuit may result in uncontrolled PLC output. A suitable external control circuit must be designed to ensure the normal operation of the equipment. z When the PLC output unit such as the relay or the transistor is damaged, the PLC output cannot be controlled as ON or OFF state. z The PLC is designed to be used in the electrical environment of indoor area B and C ☆ . However, to prevent the high lightning voltage from damaging the equipment through the ports of power input, signal input or control output, a SPD should be installed in the power supply system. ☆: According to IEC61131-2, section 8.3.1 classification declaration Notes for installation z Units should not be installed in areas subject to the following conditions: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Electric shock, fire hazard and mishandling may also damage the product. z Take special care not to allow metal debris and wire lead to fall inside the vent of the PLC during the screw hole processing and wiring. Otherwise there is a danger of fire, damage or faulty operation of equipment. z Once the installation of the new PLC is complete, remove everything on the surface of the vent, including packing goods such as protective paper. Otherwise the poor ventilation during the operation may result in fire, damage or faulty operation of equipment. z Do not wire, inset or pull out the cable plug with power applied. Otherwise there is a danger of electric shock or circuit damage. z Installation and wiring must be fastening and reliable. Bad contact may result in faulty operation of equipment. z The input/output cable of high frequency signal should use the shielding cable to improve the interference rejection of the system. Notes for wiring z Installation and wiring can be done only after the external power supplies are all disconnected. Otherwise there is a danger of electric shock or equipment damage. z Once the installation and wiring of the PLC is complete, cleanup the spot at once. To prevent the electric shock, replace the port cover of the product before power is on. z When wiring AC supplies, the ‘Live’ cable should be connected to the ‘L’ terminal and the ‘Neutral’ cable should be connected to the ‘N’ terminal. Otherwise the PLC will be damaged. z Don’t power +24V port of the main module by the external power supply. Otherwise the PLC will be damaged. z Do not lay I/O signal cables of the PLC next to other power cables or strong interference circuits. z Do not make the earth port (PG) of the main module and the heavy current power system share the same earthing. Notes for operation and maintenance z Do not touch the ports when the power is applied, otherwise there is a danger of an electric shock or faulty operation of equipment. z The cleaning and the fastening work can be done only after the power supply has been disconnected; otherwise there is a danger of electric shock. z Only after the power supply has been disconnected, can the communication signal cables and the cables of the expansion module or control unit be connected or removed. Otherwise there is a danger of equipment damage or faulty operation of equipment. z Do not disassemble the PLC. Otherwise it may destroy the inner electrical components. z Read through this manual carefully before operating the PLC. Safe and efficient operation of the product, such as program alternation, trial operation, start and stop, is only based on correct operation and maintenance. z Do not replace the button cell battery with power applied. If the battery replacement is indeed to be done with power applied, it shall always be carried out by adequately trained electric technical personnel wearing insulated gloves. Notes for the product disposal Note the following when disposing the PLC: z Explosive of the electrolytic capacity: The capacities on the circuit board may explode when burning. z Exhaust gas when burning: The main body of the PLC is plastic, and it may produce poisonous gas when burning. z Disposal of button cell battery: Classified collecting and disposing, and separating from the daily-life rubbish. Follow the local environmental regulations to dispose the PLC or dispose it as industrial waste. Contents Chapter 1 Preface 1 Chapter 2 Product Introduction 2 2.1 Outline 2 2.2 Maximum Configuration 2 2.3 Internal Memory Capacity Of User Program 2 2.4 Resource Configuration Of System Soft-device 2 2.5 High-speed Input/Output Function 3 2.6 Filter Function Of Input Port 3 2.7 Interrupt Source 3 2.8 Subroutine Call 3 2.9 Reinforced Debugging Function 3 2.10 Support Online Modification 3 2.11 Multiple Password Protection Function 4 2.12 Expansion Module 4 2.13 RUN And STOP Control 4 2.14 User Program Developing And Debugging 4 2.15 Communication And Networking 4 Chapter 3 Installation 5 3.1 Notes For Installation 5 3.2 Requirements For Installation Position 5 3.3 Installation Method 5 3.4 Installation Dimensions 6 Chapter 4 Product Specifications 8 4.1 Model Legend 8 4.2 Product Model And Configuration 8 4.2.1 Main Module 8 4.2.2 I/O Expansion Module 8 4.2.3 Special Function Module 9 4.3 Product Size 9 4.4 Environmental Requirements 9 4.5 Electric Insulation Specifications 9 4.6 Reliability 10 4.7 Power Supply Specifications 10 4.7.1 Inner Power Supply Of Main Module 10 4.7.2 Use Of Each Circuit Output Power 10 4.7.3 Power Specifications Provided By Main Module To Expansion Module 11 4.7.4 Derating Design Of Power Supply Circuit 11 4.7.5 Power Consumption Of Expansion Module 12 4.7.6 Power Capacity Calculation In Expansion Connection 12 4.8 Programming Tool Of User Program 12 Chapter 5 Input Characteristic 13 5.1 User Ports Of Main Module 13 5.2 Input Port Characteristic And Signal Specification 14 5.3 Inner Equivalent Circuit Of Input Port 15 5.4 Input Connection Of High-speed Counter 16 5.5 Interrupt Input Connection 17 5.6 Input Signal Status Indication 17 5.7 Analog Potentiometer And Application 17 5.8 Example Of Input Connection 17 Chapter 6 Output Characteristic 19 6.1 Output Port Application 19 6.2 Electric Specifications Of Output Port 19 6.3 Output Port Connection 20 6.4 Output Port Status Indication 22 6.5 Example Of Output Connection 22 Chapter 7 Expansion Module 23 7.1 Model 23 7.2 Expansion Busbar Connection 23 7.3 Expansion Module Addressing 23 7.3.1 I/O Point Addressing Number Principle 24 7.3.2 Special Function Module Addressing Number Principle 24 Chapter 8 Communication And Networking 25 8.1 Communication Port 25 8.2 Programming Environment 26 8.3 Programming Cable 26 Chapter 9 Cable Specification And Wiring 27 9.1 Connecting Power Supply Cable 27 9.2 Connecting Ground Cable 27 9.3 Connecting Common Port 28 9.4 Cable Specification 28 Chapter 10 First Operation And Maintenance 29 10.1 Notes For Application 29 10.2 Check Before Power On 29 10.3 Startup 29 10.4 RUN/STOP Switchover 29 10.4.1 How To Startup (STOP → RUN) 30 10.4.2 How To Stop (RUN → STOP) 30 10.5 Routine Maintenance 30 Chapter 11 Troubleshooting 32 Chapter 12 Instruction List 33 Chapter 13 Special Register 38 13.1 Special Intermediate Register 38 13.2 Special Data Register 42 Chapter 1 Preface 1 EC20 Series PLC User Manual Chapter 1 Preface Thank you for using EC20 series Programmable Logic Controller (PLC) made by Emerson Network Power Co., Ltd. This book contains text, diagrams and explanations that will guide the reader in the correct installation and operation of the EC20 series PLC and should be read and understood before attempting to install or use the product. The book describes the hardware, features and applications of the EC20 series PLC, also includes the options introduction, troubleshooting guide and instruction quick reference. For the information about how to setup an EC20 programming system and the customer programming application, please refer to ControlStar Programming Software User Manual or EC20 series PLC Programming Manual printed by Emerson Network Power Co., Ltd. For ordering the above user manuals, contact your Emerson distributor or sales office. This manual is designed for the engineer who is studying, programming, installing, or servicing the EC20 series PLC. Definitions of specific terms PLC: Programmable Logic Controller Main module: Refer to basic module or CPU module; it is the basic unit of the PLC. It includes master CPU, I/O ports and power supply. Expansion module: Generally refer to the modules except for the main module. I/O expansion module: The expansion module for the digital signal input/output. Special function module: Other function expansion modules except for the I/O expansion module, such as analog signal input/output module, and busbar module. Points: The sum of channel number of the input/output digital signal. Digital signal: Refer to the input/output signals that only have two states: “ON” and “OFF”. Analog signal: Continuously changed electric signal, such as 4~20mA output signal of pressure transmitter. Unipolar signal: Generally refer to the continuously changed signal with positive polarity. Bipolar signal: Generally refer to the continuously changed signal, which may be positive polarity or negative polarity. High-speed pulse: Refer to the square-wave signal with higher frequency. Counter: Refer to the counter whose counting value increases or decreases by per pulse input according to the increasing/decreasing control signal. Two-phase counter: refer to the counter that has two-pulse input ports, one is for counting up, and the other is for counting down. AB-phase counter: refer to the counter that has two input ports of quadrature phase pulse, and counts up or down according to the frequencies and phase differences of the two signals. 2 Chapter 2 Product Introduction EC20 Series PLC User Manual Chapter 2 Product Introduction 2.1 Outline The outline of EC20 main module is shown in Figure 2-1. 123 4 5 6 7 8 9101112 13 14 15 Figure 2-1 Outline of EC20 main module The name and function of the components in the figure are as follows: 1. The installation position of a button cell battery (CR2032 lithium battery) for data backup. 2. Power supply input ports 3. Signal input ports 4. Input signal status LEDs 5. 26pin busbar socket, used for connecting the expansion module 6. Output signal status LEDs 7. Fix screws, used for tightening the top/bottom cover of the PLC 8. Mounting holes, used for installing screws 9. Locking device of 35mm DIN, used for DIN rail installation mode. 10. Signal output ports 11. System operation status LEDs 12. Communication port COM1, providing RS485 and RS232 at the same time 13. Communication port COM0, RS232, Mini DIN8 socket 14. System operation control switch, with three positions: ON, TM and OFF. 15. Analog potentiometers (two) 2.2 Maximum Configuration The main module and the I/O expansion modules can achieve the most 512 logic points (256 in/256 out maximum). And eight special function modules can be expanded at most. 2.3 Internal Memory Capacity Of User Program The user program is 8K words (16K byte) at most and supports 8,000 data blocks of D register. 2.4 Resource Configuration Of System Soft-device Component Name Quantity Serial No. Note X Input relay 256 X000~X377 The soft-device numbering is octal code Y Output relay 256 Y000~Y377 The soft-device numbering is octal code M Auxiliary relay 2000 M0~M1999 LM Local relay 64 LM0~LM63 Chapter 2 Product Introduction 3 EC20 Series PLC User Manual Component Name Quantity Serial No. Note SM Special auxiliary relay 256 SM0~SM255 S State relay 992 S0~ S991 T Timer 256 T0~T255 100ms precision: T0~T209 10ms precision: T210~T251 1ms precision: T252~T255 C Counter 256 C0~C255 16 bit common increasing counter: C0~C199 32 bit common decreasing counter: C200~C235 32 bit high-speed counter: C236~C255 D Data register 8000 D0~D7999 V Local data register 64 V0~V63 Z Indexed addressing register 16 Z0~Z15 SD Special data register 256 SD0~SD255 2.5 High-speed Input/Output Function High-speed port name High-speed port type Input/output mode Max. frequency of input/output signal X0, X1 Input High-speed pulse count Single input: 50KHz; X0~X5 input at the same time: frequency sum is 80KHz X2~X5 Input High-speed pulse count Single input: 10KHz Y0, Y1 (only suitable for transistor output) Output High-speed pulse output Two ports output independently: 100KHz 2.6 Filter Function Of Input Port Function Description Digital filter function X0~X17 provide digital filter function, and filter time is within 0~60mS, set by user’s program Hardware filter function Other X input ports 2.7 Interrupt Source Provide eight external interrupt inputs, the interrupt edge can be set by users and is corresponding to X0~X7 ports; six high-speed counter interrupts; three inner timing interrupt sources. 2.8 Subroutine Call At most 64 subroutines and 6-level subroutine nesting can be used. Support local variables and variable-alias, and every subroutine can provide 16 parameters to be called at most. 2.9 Reinforced Debugging Function Provide register-forced function, convenient for debugging and analyzing the user program, improving debugging efficient. Permit the most 128 bit-registers and 16 word-registers. 2.10 Support Online Modification Users can modify the program online during operation, which is greatly convenient for modifying and upgrading the user program in important production situation. 4 Chapter 2 Product Introduction EC20 Series PLC User Manual 2.11 Multiple Password Protection Function The product provides three password authorities, which is convenient for user program access control and protecting the intelligence property. 2.12 Expansion Module The expansion module such as I/O module, analog signal input/output module, network expansion module, and position control module can be connected to the PLC main module. Every module is address allocation automatically and identification automatically. 2.13 RUN And STOP Control RUN or STOP of the EC20 can be controlled through the following methods: the RUN/STOP switch, ControlStar program system, communication port (i.e. Modbus), and standard input ports X0~X7, which are convenient for controlling system operation 2.14 User Program Developing And Debugging Provide the integrated ControlStar program system compatible with IEC61131-3 standard, and uses ladder diagram, instruction list, and sequential function diagram to program. The unit has such functions as monitoring, debugging, and modifying on-line. The program system also provides strong instruction guide and on-line help. 2.15 Communication And Networking The main module has two asynchronism serial communication ports (COM1 provides RS232 and RS485 level), for communication with personnel computer, HMI and other equipment; and the main module has an inner standard Modbus protocol to compose 1:N network; and supports freedom protocol. Provide Profibus module to compose the Profibus network. [...]... 4-2 I/O expansion module and configuration of EC20 series PLC Model Power Supply Vac Input/output points Output type EC20- 0808ERN - 8/8 Relay No EC20- 0808ETN - 8/8 Transistor No EC20- 1616ERA 220Vac 16/16 Relay Yes EC20- 1616ETA 220Vac 16/16 Transistor Yes EC20- 1600ENN - 16/00 - No EC20- 0016ERN - 00/16 Relay No EC20- 0016ETN - 00/16 Transistor No EC20 Series PLC User Manual Inner power supply Chapter 4... the outline and mounting holes of the analog signal expansion module such as EC20- 4AD, EC20- 4DA, EC20- 4AM, and EC20- 4TC are the same with that of EC20- 0808ER EC20 Series PLC User Manual Chapter 3 Installation Figure 3-6 Dimensions of outline and mounting holes of EC20- 0808ER and the analog signal expansion module EC20 Series PLC User Manual 7 8 Chapter 4 Product Specifications Chapter 4 Product Specifications... equipment PLC Best Other equipment PLC Better Figure 9-2 Other equipment PLC Worst Earthing wiring example of PLC and other equipment When using a PLC expansion module, you should connect the earthing line of each module with earthing object separately, as shown in Figure 9-3: EC20 Series PLC User Manual 28 Chapter 9 Cable Specification And Wiring Expansion module 1 PLC main module Expansion module 2 PLC. .. output capacity and work temperature EC20 Series PLC User Manual 12 4.7.5 Chapter 4 Product Specifications Power Consumption Of Expansion Module Table 4-11 Power consumption of each expansion module Max current consumption Model 5V/GND 24V/GND EC20- 0808ER 30mA 50mA 24V/COM 50mA EC20- 0808ET 80mA 0 50mA EC20- 4AD 50mA 0 25mA EC20- 4DA 50mA 0 120mA ☆ EC20- 4AM 50mA 0 90mA ☆ EC20- 4TC 50mA 0 25mA ☆: Refer to the... X1 X2 X3 X4 X5 Switch power supply X6 X7 X10 X11 X36 X37 Xn Xm Xn Xm +24V +5V GND EC20- 3232BT Figure 5-7 electric connection of EC20- 3232BT and EC20- 0808ER EC20 Series PLC User Manual 0808ER Chapter 6 Output Characteristic 19 Chapter 6 Output Characteristic 6.1 Output Port Application 1 The output type of EC20 series PLC can be divided into relay type and transistor type Both types are greatly different... Module Table 4-3 Special function module of EC20 series Model Function EC20- 4AD 4-channel analog signal input module EC20- 4DA 4-channel analog signal output module EC20- 4TC 4-channel thermocouple temperature input module EC20- 4AM 4.3 9 2-channel analog signal input module, 2-channel analog signal output module Product Size The main modules of EC20 series PLC have the same height and width, but their... X14 X16 X20 X22 X5 X7 X11 X13 X15 X17 X21 X23 Wiring of EC20- 2012BR and EC20- 2012BT +24V Y0 Y2 Y4 Y6 COM COM COM COM Y5 Y3 0 1 2 3 COM Figure 5-1 Y1 Y10 Y12 Y7 COM Y11 Y13 4 The outline and the port of EC20- 2012BR and EC20- 2012BT The pin definitions of EC20- 2012BR and EC20- 2012BT are listed in Table 5-1: Table 5-1 Pin functions of EC20- 2012BR and EC20- 2012BT Pin L/N Function Note 220Vac AC power input... Product size Model Width (mm) Height (mm) Net weight 158 90 82 680g EC20- 2012BT 158 90 82 680g EC20- 3232BR 227 90 82 950g EC20- 3232BT 227 90 82 880g EC20- 0808ER, 4AD, 4DA, 4AM, 4TC 4.4 Length (mm) EC20- 2012BR 58 90 82 240g Environmental Requirements Table 4-5 Requirements of operation, storage, and transport environments of EC20 series PLC Environmental parameters Type Parameter Climate Humidity Air pressure**... together with the main module At present, expansion modules provided by EC20 series are shown in Table 7-1 Table 7-1 Type I/O expansion module Model EC20- 0808ERN EC20- 0808ETN EC20- 4AD EC20- 4DA Special module EC20- 4AM EC20- 4TC 7.2 Expansion module provided by EC20 series Function Digital signal 8-channel input, 8-channel relay output Digital signal 8-channel input, 8-channel transistor output 4-channel analog... and monitoring the user program of the EC20 series PLC The system also provides abundant help information, which can use ladder diagram, instruction list and sequence functional diagram to program EC20 Series PLC User Manual Chapter 5 Input Characteristic 13 Chapter 5 Input Characteristic 5.1 User Ports Of Main Module The outline and the ports of EC20- 2012BR and EC20- 2012BT are the same Their port wirings . signal expansion module such as EC20- 4AD, EC20- 4DA, EC20- 4AM, and EC20- 4TC are the same with that of EC20- 0808ER. Chapter 3 Installation 7 EC20 Series PLC User Manual Figure 3-6 Dimensions. Specifications 9 EC20 Series PLC User Manual 4.2.3 Special Function Module Table 4-3 Special function module of EC20 series Model Function EC20- 4AD 4-channel analog signal input module EC20- 4DA. Data Register 42 Chapter 1 Preface 1 EC20 Series PLC User Manual Chapter 1 Preface Thank you for using EC20 series Programmable Logic Controller (PLC) made by Emerson Network Power Co.,

Ngày đăng: 29/03/2014, 22:34

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan