1. Trang chủ
  2. » Giáo án - Bài giảng

Applicability of retention modelling in hydrophilic-interaction liquid chromatography for algorithmic optimization programs with gradient-scanning techniques

8 11 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 8
Dung lượng 1,48 MB

Nội dung

Computer-aided method-development programs require accurate models to describe retention and to make predictions based on a limited number of scouting gradients. The performance of five different retention models for hydrophilic-interaction chromatography (HILIC) is assessed for a wide range of analytes.

Journal of Chromatography A, 1530 (2017) 104–111 Contents lists available at ScienceDirect Journal of Chromatography A journal homepage: www.elsevier.com/locate/chroma Full length article Applicability of retention modelling in hydrophilic-interaction liquid chromatography for algorithmic optimization programs with gradient-scanning techniques Bob W.J Pirok a,b,∗ , Stef R.A Molenaar a , Rianne E van Outersterp a , Peter J Schoenmakers a a b University of Amsterdam, van ‘t Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, Science Park 904, 1098 XH, Amsterdam, The Netherlands TI-COAST, Science Park 904, 1098 XH, Amsterdam, The Netherlands a r t i c l e i n f o Article history: Received 29 September 2017 Received in revised form November 2017 Accepted 10 November 2017 Available online 11 November 2017 Keywords: Hydrophilic-interaction chromatography Retention model Gradient scanning Method development Gradient equations a b s t r a c t Computer-aided method-development programs require accurate models to describe retention and to make predictions based on a limited number of scouting gradients The performance of five different retention models for hydrophilic-interaction chromatography (HILIC) is assessed for a wide range of analytes Gradient-elution equations are presented for each model, using Simpson’s Rule to approximate the integral in case no exact solution exists For most compound classes the adsorption model, i.e a linear relation between the logarithm of the retention factor and the logarithm of the composition, is found to provide the most robust performance Prediction accuracies depended on analyte class, with peptide retention being predicted least accurately, and on the stationary phase, with better results for a diol column than for an amide column The two-parameter adsorption model is also attractive, because it can be used with good results using only two scanning gradients This model is recommended as the first-choice model for describing and predicting HILIC retention data, because of its accuracy and linearity Other models (linear solvent-strength model, mixed-mode model) should only be considered after validating their applicability in specific cases © 2017 The Author(s) Published by Elsevier B.V This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/) Introduction Hydrophilic interaction chromatography (HILIC) has become increasingly important for the analysis of highly polar analytes, such as antioxidants [1], sugars (e.g glycomics [2–4]), (plant) metabolites [5–7], foodstuffs [8], and environmental pollutants [9] The exact mechanism of retention in HILIC has been intensively investigated and it is thought to be rather complex The currently accepted mechanism is a combination of (i) partitioning processes of the analytes between a water-poor organic mobile phase and a water-rich layer absorbed on a polar stationary-phase material [10], and (ii) electrostatic interactions between the analytes and the stationary-phase surface [11] Therefore, HILIC can best be described as a mixed-mode retention mechanism ∗ Corresponding author at: University of Amsterdam, van ‘t Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, Science Park 904, 1098 XH, Amsterdam, The Netherlands E-mail address: B.W.J.Pirok@uva.nl (B.W.J Pirok) To describe retention in HILIC, several retention models have been investigated The model most commonly used in reversedphase LC (RPLC) involves a linear relationship between the logarithm of the retention factor (k) and the volume fraction of strong solvent (ϕ) When a linear gradient is used in RPLC this results in so-called linear-solvent-strength conditions [12] Already in 1979, LSS conditions have been studied and described in detail by Snyder et al [12] and equations were also derived for situations in which analytes elute before the gradient commences or after it has been completed [12,13] However, due to the mixed-mode retention mechanism, this linear model may be less suitable to accurately model retention in HILIC To describe retention more accurately across a wider ϕ-range, Schoenmakers et al introduced a quadratic model [13], including relations for the retention factor for analytes eluting within and after a gradient However, an error function was required to allow partial integration of the gradient equation This is an impractical aspect of the relationship Moreover, the model may show deviations from the real values when predicting outside the scanning range An empirical model proposed by Neue and Kuss circumvented the integration problems, allowing analytical expressions to https://doi.org/10.1016/j.chroma.2017.11.017 0021-9673/© 2017 The Author(s) Published by Elsevier B.V This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/) B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 be obtained for retention under gradient conditions [14] A retention model based on surface adsorption has also been proposed for HILIC, predicting retention across narrow ranges of water concentrations in the eluent To account for the observed mixed-mode behaviour found in HILIC, Jin et al introduced a three-parameter model [15], which was found to precisely describe retention factors in isocratic mode [16] However, similar to the quadratic model, integration of the corresponding gradient equation was significantly complicated, involving a gamma function and potentially yielding complex numbers For efficient method development, an underlying accurate description of the retention mechanism is crucial Because gradient elution is an essential tool for analysing or scanning samples, accurate description of gradient-elution patterns is also essential Computer-aided-optimization tools, such as Drylab [17] for 1D-LC, or PIOTR [18] for 1D and 2D-LC, utilize the concept of so-called “scouting” or “scanning” runs to establish retention parameters [19], from which the optimal conditions and the optimal chromatogram can be predicted Method development in HILIC following these principles has extensively been studied by Tyteca et al [20,21] However, the currently employed retention models for HILIC not allow accurate prediction of retention times of analytes eluting during or after the completion of gradients based on a very limited number of scouting measurements This hampers the application of such optimization tools for HILIC In this work, we present the results of an evaluation study of each of the five above-listed models for predicting retention times in gradient-elution HILIC based on a limited number of scouting runs for a wide range of applications First, the equation for each retention model is addressed in the context of gradient-elution chromatography We use Simpson’s Rule [22] to approximate the integration of resulting gradient equations when an exact solution does not exist, i.e for the quadratic and mixed-mode models The performance of each of these models in computer-aided methoddevelopment programs is assessed Theory In the case that a solute elutes before the start of the gradient, the retention time (tR,before ) can be calculated from tR,before = t0 (1 + kinit ) (1) where kinit depicts the retention factor at the start of the gradient and t0 the column dead time The general equation of linear gradients allows calculation of the retention time if a compound elutes during the gradient B ϕinit +B(tR − ) dϕ t + tD = t0 − init k (ϕ) kinit (2) 105 Here, tG represents the gradient time The application of some of the proposed HILIC retention models is complicated, because the integrals in Eqs (2) and (3) cannot be analytically solved The application of each of the HILIC models for gradient-elution separations is the main topic of this paper and this will be described in detail in the following sections 2.1 Exponential model In the exponential model (Eq (4)), k0 accounts for the extrapolated retention factor for ϕ = and S denotes the change in the retention factor with increasing mobile phase strength ln k = ln k0 − Sϕ (4) This equation is often referred to as the linear-solvent-strength (LSS) equations, because it corresponds to LSS conditions in combination with linear gradients (ϕ = ϕinit + Bt) Schoenmakers et al derived equations for a compound eluting during (tR,gradient ) and after (tR,after ) the gradient [13] tR,gradient = t + tD ln + SB · kinit t0 − init SB kinit tR,after = kfinal t0 − tD + tinit kinit − BS 1− kfinal kinit + (5) + tG + (6) Here, kfinal represents the retention factor at the end of the gradient and tG the duration of the gradient 2.2 Neue-Kuss empirical model The empirical model introduced by Neue and Kuss [14] is given by ln k = ln k0 + ln (1 + S2 ϕ) − S1 ϕ + S2 ϕ (7) where the coefficients S1 and S2 represent the slope and curvature of the equation, respectively Integration of the gradient equation yields tR,gradient = ln F ϕ − init + B B(S2 − S1 lnF) (8) with F defined as F = S2 Bk0 t0 − tinit − tD kinit S2 ϕinit + e 1−S1 ϕinit (9) Similarly, introducing Eq (7) into Eq (3) and rewriting yields tR,after = kfinal t0 − tinit + tD kinit S2 ϕinit S2 ϕfinal +S2 Bk0 (e 1+S1 ϕinit − e 1+S1 ϕfinal )) + tG + (10) ϕinit In this equation k (ϕ) is the retention model, denoting the variation of the retention factor k with the composition parameter ␸ The change in ϕ as a function of time (i.e the slope of the gradient) is depicted Bϕ = ϕinit + Bt) and ␶ is the sum of the system dwell time tD , the waiting time before the gradient is programmed to start tinit , and t0 ( ≈ tD + tinit + t0 ) For useful application of gradient-elution retention prediction models in real cases, it is essential that the retention time cannot only be established if the analyte elutes during the gradient, but also if it elutes after the gradient is completed In this case, the retention is obtained by integrating the retention model in the following equation B ϕfinal ϕinit tR − − tG t + tD dϕ + = t0 − init k (␸) kfinal kinit (3) 2.3 Adsorption model The adsorption model is based on confined surface adsorption as used in normal-phase chromatography and is given by ln k = ln k0 − n ln ϕ (11) where n depicts the ratio of surface areas occupied by a water and a solute molecule [16] In the events that the compound elutes during or after the gradient retention can be calculated from [23] k0 t0 − tR,gradient = ϕ − init + B tinit +tD kinit n+1 B (n + 1) + ϕinit n+1 B (12) 106 B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 2.5 Quadratic model tR,after = kfinal − t + tD t0 − init kinit kfinal n+1 n+1 ϕfinal − ϕinit + tG + Bk0 (n + 1) (13) ln k = ln k0 + S1 ϕ + S2 ϕ2 2.4 Mixed-mode model The mixed-mode aspect of HILIC led Jin et al to propose a tailored model [15] ln k = ln k0 + S1 ϕ + S2 ln ϕ (14) where S1 is said to account for the interaction of solutes with the stationary phase and S2 for the interaction of solutes with solvents While seemingly attractive because of its ability to account for the mixed-mode character of HILIC retention, the relation does pose a practical problem upon integration of the gradient equation The calculation of the retention time using Eq (14), requires a gamma function and may possibly result in complex numbers To circumvent this, we apply Simpsons’ Rule [22] to approximate the integral (Eq (15)) ⎧ϕ +B t ⎨ final ( R,gradient − ) Simpsons ⎩ eS1 ϕ · eS2 dϕ ϕinit = Bk0 t0 − ⎫ ⎬ ⎭ tinit + tD kinit (15) ϕfinal ϕ f (ϕinit ) + 4f m ϕ + ϕinit ϕinit +2f m +4f m−1 m ϕ + ϕinit + + 2f ϕ + ϕinit m−2 m + f (ϕfinal ) ϕ − ϕinit (16) Of course, the approximation is accompanied by an error With the Simpsons’ Rule, the maximum error depends on m and can be calculated from |E| ≤ D(ϕfinal − ϕinit )5 180m4 (17) where D represents the maximum value of the fourth derivative of the retention model in the integration range from ϕinit to ϕfinal In this study, we set the acceptable calculation error to 0.001, which is much smaller than the typical experimental error Rewriting the equation yieldsm ≥ | f (ϕx ) · ϕ5 |(18) 0.18 In the case of the mixed-mode model, ϕx equals ϕinit Likewise, the mixed-mode retention model can be applied in conjunction with Eq (3), resulting in tR,after = kfinal t0 − ⎧ϕ ⎨ final Simpsons ⎩ ϕinit tinit + tD − kinit Bk0 ⎫⎞ ⎬ eS1 ϕ · eS2 dϕ ⎠ + tG + ⎭ (20) Where S1 and S2 represent the influences of the volume fraction of strong solvent Similar to the mixed-mode model, integration of the gradient-elution equation is complex Effectively, the gradient equations become ⎧ϕ +B t ⎨ final ( R,gradient −tG − ) Simpsons ⎩ eS1 ϕ · eS2 ϕ dϕ ϕinit = Bk0 t0 − tinit + tD kinit tR,after = kfinal t0 − ⎧ϕ ⎨ final Simpsons This rule divides the integral over a function, f, in our case f (ϕ) = eS1 ϕ · eS2 in m segments of width ϕ Subsequently, each segment is approximated by a solvable quadratic equation such that, in essence, the complex integral is replaced by m solvable quadratic equations (Eq (16)) f (ϕ) dϕ ≈ In comparison with the exponential (“LSS”) model, the quadratic model offers a more flexible solution across a broader range of the volume fraction of the strong solvent Retention is given by ⎩ ϕinit ⎫ ⎬ ⎭ (21) tinit + tD − kinit Bk0 ⎫⎞ ⎬ eS1 ϕ · eS2 ϕ dϕ ⎠ + tG + ⎭ (22) For calculating the number of partitions m for the Simpson’s approximation from (Eq (18)),]zϕx now equals ϕfinal , because the fourth derivative is largest at the final solvent strength Experimental 3.1 Chemicals Aqueous solutions were prepared using deionized water (Arium 611UV; Satorius, Germany; R=18.2 M cm) Acetonitrile (ACN, LC–MS grade) was obtained from Avantor Performance Chemicals (Deventer, The Netherlands) Ammonium formate, formic acid (reagent grade, ≥95%) and the peptide mix (HPLC peptide standard mixture, H2016) were obtained from Sigma-Aldrich (Darmstadt, Germany) The earl-grey tea was obtained from Maas International (Eindhoven, The Netherlands) The dyes used in this study were authentic dyestuffs obtained from the reference collection of the Cultural Heritage Agency of the Netherlands (RCE, Amsterdam, The Netherlands) 3.2 Instrumental All experiments were carried out on an Agilent 1100 LC system equipped with a quaternary pump (G1311A), an autosampler (G1313A), a column oven (G1316A) and a 1290 Infinity diode-array detector (G4212A) (Agilent, Waldbronn, Germany) In front of the column, an Agilent 1290 Infinity In-Line Filter (G5067-4638) was installed to protect the column The dwell volume was approximately 1.1 mL The injector needle was set to draw and eject at a speed of 10 ␮L·min−1 with two seconds equilibration time Two columns were used, a Waters Acquity BEH Amide (150 × 2.1 mm i.d., 1.7-␮m particles, 130-Å pore size; Waters, Milford, MA, USA) and a Phenomenex Luna HILIC column (50 × mm, ␮m, 200 Å; Phenomenex, Torrance, CA, USA), further referred to as diol column 3.3 Procedures (19) 3.3.1 Analytical methods The mobile phase consisted of acetonitrile/buffer [v/v] 97:3 (Mobile phase A) and acetonitrile/buffer [v/v] 1:1 (Mobile phase B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 B) The buffer was 10 mM ammonium formate at pH For all experiments recorded on the amide column, five different scouting gradient programs were used All gradients started from 0.0 until 0.5 isocratic at 100% A, followed by a linear gradient from 100% A to 100% B in 10 (Gradient A1), 17 (Gradient A2), 30 (Gradient A3), 52 (Gradient A4) and 90 (Gradient A5) minutes In all cases, 100% B was maintained for min, after which a linear gradient of brought the mobile phase back to the initial composition of 100% A, which was maintained for 20 to thoroughly re-equilibrate the column The flow rate was 0.25 mL min−1 For the experiments carried out on the diol column, the five different scout gradients each started with 0.0–0.5 isocratic at 100% A, followed by a linear gradient from 100% A–100% B in 0.67 (Gradient D1), 1.33 (Gradient D2), 2.0 (Gradient D3), 4.0 (Gradient D4) and 6.0 (Gradient D5) minutes The flow rate was 1.0 mL min−1 3.3.2 Sample preparation The peptide mix was used at a concentration of 1000 ppm in deionized water, and was diluted five times with ACN before analysis The injection volume was ␮L The metabolites were individually prepared as stock solutions in ACN/water with ratios (varying between 9:1 or 8:2 [v/v]) and resulting concentrations depending on the solubility of each compound (see Supplementary Material section S-1) For analysis, mixtures of seven or eight metabolites were prepared with effective metabolite concentrations in these mixtures between 100 and 500 ppm The injection volume of each mixture was ␮L The peaks in the chromatograms were identified using individual injections, clearly distinguishable peak patterns and UV–vis spectra The dyes were prepared as individual stock solutions of approximately 5000 ppm in water/MeOH (1:1) [v/v] Mixtures of 20 dyes were prepared and the resulting solution was diluted four times in ACN The mixtures were injected at a volume of ␮L with effective individual dye concentrations of approximately 25 ppm The peaks in the chromatograms were identified using the UV–vis spectra For the preparation of the earl-grey-tea sample, 200 mL of deionized water was heated until the boiling point was reached The heating was turned off and the earl-grey-tea bag was submerged in the water for After cooling, the resulting solution was diluted five times with ACN prior to analysis The injection volume was ␮L Results and discussion 4.1 Goodness-of-fit To establish a good representation of HILIC behaviour, a set of 57 analytes was compiled comprising organic acids, peptides, synthetic and natural dyes and components found in black tea (Table 1) The set mainly comprises acidic, basic, zwitterionic and neutral compounds with varying polarity and, in most cases, aromatic functionality The retention times for all analytes on the amide column were recorded with five different gradient programs (see Experimental section, gradients A1-A5) Using the obtained retention times (see Supplementary Material section S-2 for all retention time data), all retention parameters were determined for each retention model by using the nonlinear-programming-solver fminsearch function of MATLAB to fit the retention model to the data The resulting retention parameters are displayed in Table For most analytes, reasonable values were found Peptide component exhibited no retention and thus was excluded from this study To assess the ability of the different models to describe the retention behaviour, the Akaike Information Criterion (AIC) [24] was used This criterion provides a measure for the mean-squared error in describing the retention behaviour based on information 107 theory and it can be regarded as a goodness-of-fit indicator The criterion has been used before to study retention behaviour in HILIC [16] and partition coefficients [25] One attractive feature of the AIC criterion is that it allows comparison of models with different numbers of terms For example, a three-parameter model is expected to describe the data better than a two-parameter model The AIC criterion accounts for this by penalizing the model for each additionally employed parameter, allowing an unbiased comparison For calculation the AIC, the number of parameters, p, the number of experiments, n, and the sum-of-squares error (SSE) from the fit of the retention model are used AIC = 2p + n In SSE n +1 (23) Table lists the AIC values obtained Lower AIC values generally indicate a better description of the retention behaviour Generally, the adsorption and Neue-Kuss models show favourable AIC values In the case of the Neue-Kuss model, this is in agreement with previous studies [16] This is also reflected in Fig 1, where the number of found compounds with a given AIC value are grouped in a histogram per retention model It can be seen that the LSS model performs poorly in most cases and that both the mixed-mode and quadratic models are not robust across the range of compounds Conversely, the plot suggests that the adsorption and Neue-Kuss models perform more reliably, in particular for the metabolites and dyes (see Supplementary Material section S-3 for histograms per class of analytes) 4.2 Prediction errors With this insight, the ability of the models to reliably predict retention times based on a smaller number of gradients was studied to allow automatic gradient optimization To simulate such a situation, the retention times from gradients A2 and A4 were excluded, and the retention parameters were determined once more using exclusively the data from gradients A1, A3 and A5 The obtained retention parameters were used to predict the retention times for gradients A2 and A4 The results are plotted in Fig 2A for the amide column, where the errors in prediction of the retention times of all analytes in gradient A2 are reflected by the solid bars and the dashed bars reflect the prediction errors for gradient A4 Most models perform very similarly, with an average prediction error of approximately 2% for retention times of gradient A2 and 2.5% for retention times of gradient A4 A significant deviation of this impression is the performance of the Neue-Kuss model, which is surprising because of the low AIC values found for this model This can be explained by realizing that this is an empirical model now using just three points (A1, A3 and A5) instead of all five such, was the case for Fig To investigate to which extent the observations obtained thus far also pertain to other stationary phases, the retention times for 17 of the analytes (peptides and metabolites) were also recorded on a cross-linked diol column, using a similar set of scanning gradients (see Supplementary Material section S-4 for the obtained retention times, determined retention parameters and the calculated AIC values; see Section 3.3.1 for gradient programs and conditions) Again, using exclusively data from gradients D1, D3 and D5, the retention times of gradient D2 and D4 were predicted and the prediction errors are shown in Fig 2B Interestingly, the prediction errors across the range of models is much better with, with prediction error values of approximately 0.5% for D2 and 1.0% for D4 Noteworthy is, however, the dramatic performance of the Neue-Kuss model for which the box-and-whisker plots are off-scale The lower prediction errors suggest a more-regular behaviour of the diol column It is worth to point out that the obtained retention factors for both columns were rather similar To rule out that this significantly better performance 108 Table Overview of determined retention parameters and calculated AIC values for all 57 analytes and five studied retention models based on five scanning gradients Mixed-Mode LSS * ** ln k0 3.322 3.781 3.975 4.830 4.604 5.251 2.245 2.626 2.746 2.731 2.783 3.064 3.228 3.672 3.131 3.906 4.511 4.374 3.658 4.248 4.330 −42.339 4.247 4.279 4.169 4.597 4.541 4.569 3.717 3.682 3.581 3.238 3.115 2.990 2.871 2.554 2.407 2.267 5.497 5.251 3.863 3.039 2.193 1.610 2.546 2.931 3.112 3.299 3.660 3.829 5.117 2.866 4.218 4.452 3.769 4.008 4.402 S 18.069 18.941 15.981 20.493 17.599 13.292 11.175 12.234 10.943 10.730 10.090 12.556 12.835 15.929 10.230 14.159 17.591 15.552 12.611 14.714 12.909 108.595 17.496 16.309 14.040 12.198 9.651 11.542 9.580 10.073 11.043 10.439 10.174 9.708 9.144 7.575 6.478 5.580 14.754 15.050 17.934 21.244 11.969 4.453 6.260 9.448 9.765 10.441 9.765 10.041 15.874 12.606 17.305 18.409 15.093 15.194 12.318 AIC 7.386 8.570 6.959 9.618 11.171 15.366 5.807 2.614 4.915 8.425 4.831 9.744 7.439 6.827 7.552 9.265 10.704 8.972 11.412 12.319 13.198 −27.618 12.144 12.836 13.190 16.158 13.864 13.475 14.081 13.518 11.842 9.920 9.162 8.447 7.611 4.480 3.309 1.369 7.222 7.731 5.116 0.845 −7.432 −44.498 10.792 10.724 10.239 9.778 10.972 11.667 16.530 8.217 9.678 11.015 5.753 11.364 14.317 ln k0 −2.217 −2.790 −2.290 −3.726 −2.867 −2.011 −0.699 −0.991 −0.708 −0.709 −0.559 −1.170 −1.307 −1.639 −0.686 −1.834 −2.892 4.344 −1.356 −2.071 −1.636 −31.941 4.220 4.252 4.148 4.568 −0.734 −1.329 −0.586 −0.716 −0.956 −0.744 −0.661 −0.533 −0.388 0.000 0.256 0.464 −2.613 −2.611 −2.670 −2.772 0.870 1.012 0.352 −0.440 −0.514 −0.753 −0.640 −0.742 −2.661 1.892 −2.689 −3.039 −2.010 −1.666 −0.927 Two well−separated peaks were systematically observed for tyramine Excluded from study due to lack of retention S1 0.708 0.000 0.006 0.001 0.088 0.000 0.000 0.000 0.143 0.000 0.095 0.000 0.002 1.524 0.000 0.000 0.000 15.242 0.000 0.000 0.000 414.976 17.174 16.009 13.815 11.945 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 6.579 1.561 0.000 0.000 0.130 0.000 0.000 0.000 0.000 9.524 0.000 0.000 0.000 1.209 1.280 AIC 5.225 5.768 2.875 7.156 8.560 13.394 5.681 −2.923 0.966 5.485 0.812 6.508 2.110 1.995 1.425 4.011 7.775 11.235 7.164 9.176 9.610 −25.618 14.132 14.817 15.164 18.118 8.973 9.714 10.585 9.910 7.795 5.061 4.208 3.473 2.606 −0.123 −0.174 −0.943 −1.268 0.066 −2.887 −4.985 −8.782 −41.591 12.198 11.070 10.199 9.939 9.304 9.562 15.854 10.154 6.049 8.624 −2.113 12.239 15.275 ln k0 3.325 3.765 3.981 7.831 8.625 8.272 2.296 2.637 2.784 2.781 2.809 3.069 3.965 3.680 3.660 5.000 4.477 5.784 3.673 6.302 6.107 −36.800 4.224 4.276 4.201 4.654 5.624 5.973 4.573 4.573 4.453 3.923 3.735 3.548 3.363 2.582 2.412 2.268 7.303 7.018 3.865 4.090 2.208 1.656 2.868 3.533 3.147 3.334 4.376 4.676 9.443 2.888 4.203 4.415 3.792 4.002 5.021 Neue-Kuss Adsorption Quadratic S2 1.564 1.940 1.951 2.801 2.456 2.753 0.764 0.977 0.956 0.953 0.939 1.207 1.321 1.596 1.126 1.807 2.414 0.000 1.551 2.063 2.018 0.489 0.000 0.000 0.000 0.000 1.953 2.112 1.398 1.411 1.415 1.190 1.111 1.024 0.936 0.711 0.593 0.491 3.105 2.907 1.969 1.553 0.338 0.146 0.617 0.971 1.071 1.221 1.382 1.503 2.769 0.269 2.183 2.402 1.769 1.791 1.842 S1 −18.253 −18.717 −16.211 −62.722 −72.020 −40.755 −12.574 −12.644 −11.849 −11.851 −10.809 −12.842 −29.081 −16.197 −21.394 −32.352 −17.211 −35.798 −13.027 −44.134 −35.822 −66.500 −17.219 −16.372 −14.625 −12.952 −20.692 −27.111 −22.314 −23.882 −25.940 −24.121 −23.304 −22.129 −20.640 −8.359 −6.640 −5.608 −31.694 −33.179 −18.121 −53.446 −12.507 −6.546 −14.500 −23.285 −10.562 −11.215 −20.954 −22.322 −61.174 −13.227 −17.198 −17.996 −15.647 −15.209 −20.213 S2 1.952 0.165 1.880 133.254 164.111 56.057 3.847 3.064 3.511 3.505 3.707 2.479 68.844 2.022 43.706 62.068 0.000 62.181 2.318 89.891 62.602 48.000 0.112 1.162 2.514 2.459 23.549 36.704 36.988 41.868 49.730 51.448 51.597 50.565 48.243 3.876 0.799 0.130 36.209 41.868 1.992 198.823 3.972 19.859 35.601 57.890 3.471 3.383 33.942 35.226 107.417 3.392 0.862 0.001 2.944 0.921 21.190 AIC 9.400 10.719 8.983 −5.245 −3.301 7.373 7.781 4.402 6.654 10.254 6.420 11.619 1.422 8.813 2.507 2.399 12.920 0.924 13.271 0.722 3.062 −25.618 14.132 14.827 15.209 18.199 8.624 7.987 10.200 9.245 6.909 4.284 3.633 3.172 2.645 5.869 5.195 3.355 −14.046 −11.468 7.174 −18.434 −5.732 −45.932 11.405 9.400 11.956 11.512 6.924 6.668 5.178 10.211 11.817 13.210 7.588 13.398 15.605 ln k0 −2.373 −2.790 −2.300 −3.729 −2.930 −2.008 −0.693 −0.991 −0.771 −0.709 −0.598 −1.173 −1.304 −2.148 −0.688 −1.837 −2.889 −2.367 −1.360 −2.070 −1.636 5.784 −2.867 −2.612 −2.002 −1.654 −0.735 −1.328 −0.590 −0.721 −0.961 −0.747 −0.663 −0.534 −0.387 0.005 0.264 0.473 −2.615 −2.610 −2.671 −2.774 −0.756 0.708 0.360 −0.439 −0.550 −0.757 −0.644 −0.747 −2.657 −1.184 −2.685 −3.035 −2.012 −2.172 −1.567 n 1.604 1.940 1.955 2.802 2.482 2.752 0.763 0.977 0.975 0.953 0.950 1.208 1.319 1.745 1.127 1.807 2.413 2.219 1.552 2.062 2.018 −14.031 2.268 2.235 2.029 2.244 1.953 2.111 1.400 1.413 1.417 1.191 1.112 1.024 0.935 0.709 0.590 0.488 3.106 2.907 1.969 1.554 0.754 0.220 0.614 0.971 1.081 1.222 1.384 1.504 2.768 1.128 2.182 2.401 1.770 1.955 2.070 AIC 2.940 3.767 0.870 5.156 6.518 11.394 3.687 −4.921 −1.172 3.488 −1.231 4.503 0.097 −1.174 −0.581 2.009 5.775 1.674 5.159 7.176 7.610 −27.618 12.988 13.811 14.500 17.441 6.973 7.714 8.581 7.906 5.790 3.055 2.203 1.472 0.610 −2.097 −2.140 −2.910 −3.267 −1.935 −4.888 −6.996 −17.922 −37.989 10.197 9.070 8.178 7.939 7.304 7.562 13.854 8.736 4.050 6.625 −4.116 10.249 13.291 ln k0 7.430 9.177 6.379 8.452 8.557 5.297 4.871 4.403 4.139 5.527 3.773 7.528 5.562 6.876 4.476 4.236 7.989 8.010 7.228 7.713 6.732 −48.236 4.544 4.559 3.853 4.118 4.872 6.872 5.378 6.258 6.671 5.395 5.000 4.610 4.228 3.379 3.065 2.757 7.940 4.647 7.390 5.858 3.217 1.639 2.967 4.057 4.188 3.670 5.084 4.027 4.536 2.895 8.124 4.661 6.185 5.406 4.134 S1 249.896 282.120 96.118 121.672 132.038 14.315 239.184 125.560 88.312 187.602 61.007 278.750 120.642 147.934 67.053 23.672 121.060 122.006 152.984 120.650 74.771 −61.782 24.902 22.906 6.795 4.013 15.431 60.775 57.857 95.731 127.455 102.156 94.415 85.555 75.597 54.331 46.820 38.480 54.203 6.697 159.770 201.297 94.330 9.853 29.745 62.526 54.802 23.892 52.909 15.236 7.258 14.030 151.117 23.962 102.375 56.080 7.430 S2 19.696 18.957 7.975 7.762 8.858 0.160 26.905 14.849 10.965 19.457 8.018 22.807 11.979 12.188 7.857 1.472 8.521 8.780 12.749 9.115 6.107 58.202 1.002 0.902 −1.317 −1.481 0.861 4.861 5.904 9.034 11.420 10.706 10.465 10.096 9.542 8.216 7.783 7.058 3.287 −1.194 12.244 18.063 13.759 2.002 4.983 8.015 6.711 2.407 5.564 0.922 −1.233 0.312 10.798 0.787 8.910 4.741 −0.818 AIC 0.578 −0.045 1.096 5.553 5.938 17.142 2.576 −8.292 −0.413 −3.392 0.743 −3.007 −1.056 −3.958 0.491 9.022 5.547 −0.288 −0.196 5.696 7.647 −25.618 14.271 14.991 15.008 17.816 13.786 8.670 9.509 7.434 4.745 1.888 1.261 0.866 0.448 −1.060 −0.570 −0.921 −0.654 13.088 −23.321 −17.595 −43.011 −49.004 11.920 10.550 9.669 10.116 8.605 12.236 19.873 10.213 1.792 12.229 −6.772 12.376 17.011 B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 Compound tea component tea component tea component tea component tea component tea component nicotinic acid benzyltrimethylammonium adenine hypoxanthine adenosine benzylamine tyramine component 1* tyramine component 2* cytosine dopamine rutin tryptophan deoxyguanosine phenylalanine thiamine peptide component 1** peptide component peptide component peptide component peptide component Indigo Carmine Azo Fuchsine 6B Indigo Carmine Orange GG Crystal Ponceau 6R Auramine component Auramine component Auramine component Auramine component Rhodamine B Crystal Violet Diamond Green G Taetrazine Cochineal Red A Ponceau RR Gongo Red Patent Blue V Rhodamine Safranine T component Safranine T component Cotton Scarlet Orcein component Orcein component Fast Acid Magenta B Yellowish Light Green SF Orcein component Orcein component Orcein component Orcein component Orcein component Rutin B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 109 Fig Quality of fit of 56 retained analytes based on the obtained AIC values for each retention model The analytes were classified within distinct ranges of AIC values for clarity See Supplementary Material section S-3 for quality-of-fit histograms per analyte class Fig Box-and-whisker plot showing the errors of prediction for (A) 56 analytes on the amide column, (B) 17 analytes on the diol column (C) 17 analytes on the amide and diol column For each column/model combination a plot is provided for the prediction errors of both the second and fourth gradient (A2 and A4 for amide and D2 and D4 for the diol) Plot C reflects results exclusively for gradient for both columns Note the different scales on the y-axes of specific models is caused by the absence of the dyes and/or tea components in the data set, the plot shown as Fig 2C compares exclusively the prediction errors for the 17 selected analytes The observed trends support those found in Figs 2A and 2B 4.3 Repeatability To study the robustness of fitting the retention parameters and predicting retention times, ten analytes were selected and mea- 110 B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 Fig Retention curves of 10 selected analytes for the (A): LSS, (B) mixed-mode, (C) quadratic, (D) adsorption and (E) Neue-Kuss models Each curve represents the average of five sets of retention parameters derived from five sets of gradient retention data The error bars shown represent the uncertainty sured five times with all five gradients on the amide column The resulting retention curves are shown in Fig The error bars signify the spread based on the five determinations Narrow spreads in the retention curves were observed for the LSS and mixed-mode models, but especially for the adsorption model The spread was larger for a number of components with the Neue-Kuss model, despite the use of five data points for fitting, and it was dramatic for the quadratic model One trend that can be observed is that for specific (mostly earlyeluting) analytes the spread is larger towards higher fractions of water The typical HILIC conditions may no longer be applicable in this range Earlier-eluting compounds are generally more difficult to fit with the relatively limited gradient range used for scouting.To study the influence of the number of scanning gradients on the error in prediction, retention parameters were determined for each possible combination of gradients where the predicted gradient would fall within the scanning range For example, gradients A1, A2 and A4 could be combined to predict A3 as the latter falls within the scanning range, whereas this was not the case for predicting gradient A4 from gradients A1, A2 and A3 The results are shown in Fig 4, with the plot showing the prediction errors for all 56 retained analytes plotted against the number of used scanning gradients Note that the mixed-mode, quadratic and Neue-Kuss models were not investigated for the use with two scanning gradients as they are three-parameter models Not surprisingly, a larger number of scanning gradients improves the accuracy of the predictions However, we can see that for some models this trend is more significant than for other ones Using four scanning gradients instead of two provides just minor improvements in prediction accuracy for the adsorption model, which appears to perform solidly for the amide column It should also be noted that the effect of additives, which have been shown to influence the type of interactions in HILIC, have not been evaluated here [26] B.W.J Pirok et al / J Chromatogr A 1530 (2017) 104–111 Fig Plot showcasing the mean error in prediction for all 56 retained analytes as a function of the number of scanning gradients used To establish this plot, all possible combinations of scanning gradients (A1–A5) were used with the restriction that the predicted gradient must fall within the scanning range Concluding remarks We have investigated the quality-of-fit and prediction accuracies for five retention models and a wide array of compounds from different classes For most compound classes, the adsorption model provides the most robust performance in terms of its ability to describe and accurately predict HILIC retention based on a limited number of scanning gradients Prediction accuracies were generally better for a diol column than for an amide column, with the exception of the Neue-Kuss model which performed poorly when using three scouting runs on either column While the adsorption model was found to perform robustly for most of the investigated analytes, the data suggest a strong effect of the combination of analyte class and stationary-phase chemistry on model performance The two-parameter model is also attractive, because it can be used with good results using only two scanning gradients We recommend that the adsorption model should be the first-choice model for describing and predicting HILIC retention data, unless data are available to demonstrate that other models (“LSS” model, mixed-mode model) perform adequately in specific situations Based on the present data, we cannot recommend the quadratic and Neue-Kuss models for use in HILIC Acknowledgement The MANIAC project is funded by the Netherlands Organisation for Scientific Research (NWO) in the framework of the Programmatic Technology Area PTA-COAST3 of the Fund New Chemical Innovations (Project 053.21.113) Agilent Technologies is acknowledged for supporting this work The Dutch Institute for Cultural Heritage (RCE) is kindly acknowledged for providing the aged synthetic and natural dye samples Appendix A Supplementary data Supplementary data associated with this article can be found, in the online version, at https://doi.org/10.1016/j.chroma.2017.11 017 References [1] K.M Kalili, S De Smet, T Van Hoeylandt, F Lynen, A De Villiers, Comprehensive two-dimensional liquid chromatography coupled to the ABTS radical scavenging assay: a powerful method for the analysis of phenolic antioxidants, Anal Bioanal Chem 406 (2014) 4233–4242, http://dx.doi.org/ 10.1007/s00216-014-7847-z [2] M Wuhrer, A.R de Boer, A.M Deelder, Structural glycomics using hydrophilic interaction chromatography (HILIC) with mass spectrometry, Mass Spectrom Rev 28 (2009) 192206, http://dx.doi.org/10.1002/mas.20195 111 ă [3] L.R Ruhaak, C Huhn, W.-J Waterreus, A.R de Boer, C Neususs, C.H Hokke, et al., Hydrophilic interaction chromatography-based high-throughput sample preparation method for N-glycan analysis from total human plasma glycoproteins, Anal Chem 80 (2008) 6119–6126, http://dx.doi.org/10.1021/ ac800630x [4] G Zauner, A.M Deelder, M Wuhrer, Recent advances in hydrophilic interaction liquid chromatography (HILIC) for structural glycomics, Electrophoresis 32 (2011) 3456–3466, http://dx.doi.org/10.1002/elps 201100247 [5] T Zhang, D.J Creek, M.P Barrett, G Blackburn, D.G Watson, Evaluation of coupling reversed phase, aqueous normal phase, and hydrophilic interaction liquid chromatography with orbitrap mass spectrometry for metabolomic studies of human urine, Anal Chem 84 (2012) 1994–2001, http://dx.doi.org/ 10.1021/ac2030738 [6] S.U Bajad, W Lu, E.H Kimball, J Yuan, C Peterson, J.D Rabinowitz, Separation and quantitation of water soluble cellular metabolites by hydrophilic interaction chromatography-tandem mass spectrometry, J Chromatogr A 1125 (2006) 76–88, http://dx.doi.org/10.1016/j.chroma.2006.05.019 [7] V.V Tolstikov, O Fiehn, Regular article analysis of highly polar compounds of plant origin: combination of hydrophilic interaction chromatography and electrospray ion trap mass spectrometry, Anal Biochem 301 (2002) 298–307, http://dx.doi.org/10.1006/abio.2001.5513 [8] J Bernal, A.M Ares, J Pól, S.K Wiedmer, Hydrophilic interaction liquid chromatography in food analysis, J Chromatogr A 1218 (2011) 7438–7452, http://dx.doi.org/10.1016/j.chroma.2011.05.004 [9] A.L.N van Nuijs, I Tarcomnicu, A Covaci, Application of hydrophilic interaction chromatography for the analysis of polar contaminants in food and environmental samples, J Chromatogr A 1218 (2011) 5964–5974, http:// dx.doi.org/10.1016/j.chroma.2011.01.075 [10] A.J Alpert, Hydrophilic-interaction chromatography for the separation of peptides, nucleic acids and other polar compounds, J Chromatogr A 499 (1990) 177–196, http://dx.doi.org/10.1016/S0021-9673(00)96972-3 [11] P Hemström, K Irgum, Hydrophilic interaction chromatography, J Sep Sci 29 (2006) 1784–1821, http://dx.doi.org/10.1002/jssc.200600199 [12] L.R Snyder, J.W Dolan, J.R Gant, Gradient elution in high-performance liquid chromatography, J Chromatogr A 165 (1979) 3–30, http://dx.doi.org/10 1016/S0021-9673(00)85726-X [13] P.J Schoenmakers, H a H Billiet, R Tijssen, L Degalan, Gradient selection in reversed-Phase liquid-Chromatography, J Chromatogr 149 (1978) 519–537, http://dx.doi.org/10.1016/s0021-9673(00)81008-0 [14] U.D Neue, H.J Kuss, Improved reversed-phase gradient retention modeling, J Chromatogr A 1217 (2010) 3794–3803, http://dx.doi.org/10.1016/j.chroma 2010.04.023 [15] G Jin, Z Guo, F Zhang, X Xue, Y Jin, X Liang, Study on the retention equation in hydrophilic interaction liquid chromatography, Talanta 76 (2008) 522–527, http://dx.doi.org/10.1016/j.talanta.2008.03.042 ˇ ˇ N Vanková, J Kˇrenková, J Fischer, Comparison of isocratic retention [16] P Cesla, models for hydrophilic interaction liquid chromatographic separation of native and fluorescently labeled oligosaccharides, J Chromatogr A 2016 (1438) 179–188, http://dx.doi.org/10.1016/j.chroma.2016.02.032 ® [17] J.W Dolan, D.C Lommen, L.R Snyder, Drylab computer simulation for high-performance liquid chromatographic method development, J Chromatogr A 485 (1989) 91–112, http://dx.doi.org/10.1016/S00219673(01)89134-2 [18] B.W.J Pirok, S Pous-Torres, C Ortiz-Bolsico, G Vivó-Truyols, P.J Schoenmakers, Program for the interpretive optimization of two-dimensional resolution, J Chromatogr A 2016 (1450) 29–37 ((Accessed 26) May 2016) http://www.sciencedirect.com/science/article/pii/S0021967316305039 [19] P.J Schoenmakers, Á Bartha, H.A.H Billiet, Gradien elution methods for predicting isocratic conditions, J Chromatogr A 550 (1991) 425–447, http:// dx.doi.org/10.1016/S0021-9673(01)88554-X [20] E Tyteca, D Guillarme, G Desmet, Use of individual retention modeling for gradient optimization in hydrophilic interaction chromatography: separation of nucleobases and nucleosides, J Chromatogr A 1368 (2014) 125–131, http://dx.doi.org/10.1016/j.chroma.2014.09.065 [21] E Tyteca, A Périat, S Rudaz, G Desmet, D Guillarme, Retention modeling and method development in hydrophilic interaction chromatography, J Chromatogr A 1337 (2014) 116–127, http://dx.doi.org/10.1016/j.chroma 2014.02.032 [22] E Süli, D.F Mayers, An Introduction to Numerical Analysis, Cambridge University Press, Cambridge, 2003, http://dx.doi.org/10.1017/ CBO9780511801181 [23] P Jandera, J Churáˇcek, Gradient elution in liquid chromatography II, J Chromatogr A 91 (1974) 223–235, http://dx.doi.org/10.1016/S00219673(01)97902-6 [24] H Akaike, A new look at the statistical model identification, IEEE Trans Automat Contr 19 (1974) 716–723, http://dx.doi.org/10.1109/TAC.1974 1100705 [25] M.H Abraham, W.E Acree, A.J Leo, D Hoekman, J.E Cavanaugh, Water–Solvent partition coefficients and log P values as predictors for Blood?Brain distribution; application of the akaike information criterion, J Pharm Sci 99 (2010) 2492–2501, http://dx.doi.org/10.1002/jps.22010 [26] D.V McCalley, Effect of mobile phase additives on solute retention at low aqueous pH in hydrophilic interaction liquid chromatography, J Chromatogr A 1483 (2017) 71–79, http://dx.doi.org/10.1016/j.chroma.2016.12.035 ... nicotinic acid benzyltrimethylammonium adenine hypoxanthine adenosine benzylamine tyramine component 1* tyramine component 2* cytosine dopamine rutin tryptophan deoxyguanosine phenylalanine thiamine... determined for each retention model by using the nonlinear-programming-solver fminsearch function of MATLAB to fit the retention model to the data The resulting retention parameters are displayed in. .. completed In this case, the retention is obtained by integrating the retention model in the following equation B ϕfinal ϕinit tR − − tG t + tD dϕ + = t0 − init k (␸) kfinal kinit (3) 2.3 Adsorption

Ngày đăng: 31/12/2022, 09:39

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN