1. Trang chủ
  2. » Tất cả

iC5 e manual

20 1 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Drive Solution 0 4 2 2kW 1 phase 200 230Volts Variable Frequency Drive / Inverter Starvert iC5 �� Modbus communication (Option) �� PID control �� Sensorless vector control �� Motor parameter auto tuni[.]

Variable Frequency Drive / Inverter Starvert iC5 0.4 - 2.2kW phase 200- 230Volts Drive Solution “ Global standard iC5, serves a wide variety of applications to meet the majority of user needs ” � Modbus communication (Option) � PID control � Sensorless vector control � Motor parameter auto tuning Models 05 04 Features Wiring 07 06 Specifications Keypad 08 08 Terminal configuration Program parameters descriptions 11 09 Program Parameters Tips on Installation 18 16 Checking & Troubleshooting “ Compact iC5, is the best for a small and cost effective configuration” Features Sensorless vector control The iC5 adopts sensorless vector control algorithm, and it improves not only the torque control characteristics, but the speed controlability in an uncertain condition caused by the load variation as well LS Inverter iC5 Series Auto tuning The auto tuning algorithm in the iC5 sets the motor factors automatically that brings the traditional commissioning difficulties mainly in low speed by the load variation and the low torque generation to a settlement � Difficulty of measuring the motor constant � Input errors by an user � Low torque in low speed � Low speed by the load variation � Setup by an expert characteristic � � Setup by an user � Improving torque in low speed � Auto tuning of the motor characteristics � Optimized motor control PNP and NPN switchable dual signals The iC5 provides PNP and NPN signals for outside controllers It works with 24Vdc regardless of the type of PLC or control signals Communication interface, ModBus-RTU The iC5 provides the most popular communication interface, ModBus-RTU for remote control by PLC or other devices Programmable PID process control PID process control is used in iC5 to make speed corrections quickly with a minimal amount of overshoot and oscillation for the control of flow, temperature, pressure and etc 04 Models Applicable motor 220V, single phase 0.4kW (0.5HP) SV004iC5-1 0.75kW (1HP) SV008iC5-1 1.5kW (2HP) SV015iC5-1 2.2kW (3HP) SV022iC5-1 EMI filter optional Input voltage LS Starvert drive Motor rating (004 : 0.4kW ~ 022 : 2.2kW) Name of Series Model no of LS Starvert drive INPUT 200 ~ 230V 5.5A 1phase 50/60Hz OUTPUT ~ INPUT V 3phase 2.5A 0.1~400Hz 0.5HP/0.4kW Input : voltage, current, frequency and phase Output : voltage, current, capacity(FLA), frequency and phase Barcode and Serial no 05 Specifications � Specifications (200-230V class) Model Motor rating [HP] [kW] Capacity[kVA] FLA[A] Voltage Frequency Voltage Frequency Output ratings Input ratings SV004iC5-1 0.5 0.4 0.95 2.5 SV008iC5-1 SV015iC5-1 0.75 1.5 1.9 Three phase, 200 to 230V to 400Hz Single phase, 200 to 230V ( ±10% ) 50 to 60Hz ( ±5% ) SV022iC5-1 2.2 4.5 12 � Control Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost V/F control, Sensorless vector control ∙Digital reference : 0.01Hz ∙Analog reference : 0.06Hz/60Hz ∙Digital : 0.01% of Maximum output frequency ∙Analog : 0.1% of Maximum output frequency Linear, Squar pattern, User V/F 1min at 150%, 30sec at 200% ( with inverse characteristic ) Manual( to 15% adjustable ), Auto � Operation Input signal Operator control Frequency setting Start signal Multi-step Multi-step accel /decel time Output signal Emergency stop Jog Fault reset Operation status & Fault output Indicator Operation function Keypad / Terminal / Communications ∙Analog : 0~10V/4~20mA ∙Digital : Keypad ∙Communication : RS485 Forward / Reverse Setting up to speeds ( use multi-function terminal ) 0.1~6000 sec Max types available by multi-function terminal Selectable accel/decel patterns : Linear, U and S Interrupting the output of the drive Jog operation Reset the fault when protective function is active Frequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage, Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output ( Relay and Open collector output ) Choose one from output frequency, current, voltage and DC voltage.(Output voltage : 0~10V ) DC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control � Protection functions Drive trip Drive alarm Momentary power less Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload , External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error Stall prevention, Overload alarm ∙Less than 15 msec : keeping operation ∙More than 15 msec : auto restart available � Display keypad Operation information Trip information Output frequency, current and voltage, Set frequency value, Operation speed, DC voltage Display the trip cause when the protection function activates Recent faults records stored � Environment Operating ambient temp Storage temperature Humidity Altitude & Vibration Atmosphere Pressure -10℃ ~ 50℃ -20℃ ~ 65℃ 90%Rh max.(non condensing) 1000m max, 5.9m/sec2(0.6g) max No corrosive gas, flammable gas, oil mist or dust 70~106k Pa 06 Wiring short-circuit link (* reserved for DC reactor) P1 P N MCCB AC input Single phase 200 ~ 230V L1 U L2 V G W IM KNOB Ground Multi-function input terminals, P1 to P5 Analog output (0~10V) P1 (factory set : Forward) P2 (factory set : Reverse) AM P3 (factory set : Emergency stop) AM Multi-function Input terminal P4 (factory set : RST) CM P5 (factory set : JOG) P24 Multi-function relay output terminal 30A PNP DC24V output 30B 30C VR Power for speed signal (12V 10mA) MO Multi-function open collector output terminal EXTG VI I Speed signal input (0~10V) Speed signal input (4~20mA) CM Common Note : 1.●= Main circuit terminal ○ = Control circuit terminal Analog output voltage is adjustable upto 12V Speed command can be set by Voltage, Current, Voltage+Current, Keypad, Keypad knob+Voltage , and Keypad knob+current 07 Terminal configuration L1 L2 P Terminal L1, L2 U, V, W P, P1 G 30A 30B Terminal Input Output P1, P2 P3, P4, P5 P24 VR VI I CM AM-CM P1 N U Signal AC line input Drive output DC reactor Ground 30C V W G Description Single phase AC line input phase output terminals to motor Connecting DC reactor Chassis ground P4 P5 VR V1 CM I AM MO EXTG P24 P1 P2 CM P3 Signal Multi-function input PNP DC24V output Frequency setting power Frequency setting(Voltage) Frequency setting(Current) Common For monitoring 330A, 30C Multi-function relay and 30B Open collector output MO-EXTG Terminal Description Used for multi-function input Factory default settings are as follows P1 = FX, Forward P2 = RX, Reverse P3 = BX, Emergency stop P4=RST, Fault reset P5=JOG, Jog Operation Command DC24V power supply in case of PNP mode Power for Analog frequency setting, Maximum output is +12V 10mA Input DC to 10V to set frequency Input resistance is 20kΩ Input DC to 20mA to set frequency Input resistance is 250Ω Common terminal for the analog frequency setting signal and the FM(for monitoring) Output one out of Output frequency, Output current, Output voltage and DC voltage Factory default set is to Output frequency Maximum output voltage = to 12V, output current = 10mA To interrupt the output when the protection function activates or output multi-function signal Multi-function relay terminal : Max AC250V/1A, DC30V/1A Open collector output terminal : Max DC24V 50mA Keypad Key RUN STOP/RESET ● Function Run key Stop/Reset key Program/Enter Frequency Selection Up Down Left Right KNOB(Volume) NPN/PNP ▲ ▼ ◀ ▶ 08 Description To operate the drive To stop operating or reset in case of fault To change parameters and save them To change the frequency Mode selection between NPN and PNP To increase the parameter values To decrease the parameter values To move the cursor left To move the cursor right Program parameters � Parameter group There are parameter groups to set parameters properly for the operation Group Drive group Function group Function group Input/Output group Description Basic parameters such as Command frequency, Accel/Decel time, etc Basic functional parameters such as Max frequency, Torque boost, etc Application parameters such as Frequency jump, Max./Min of limit of frequency, etc Parameters to construct the sequence such as Multi-function terminal setting, Auto operation, etc � Parameter group navigation Drive group DRV Gr FU1 Gr FU2 Gr I/O Gr Basic operation parameters such as Command frequency, Accel/Decel time, etc Function group Basic functional parameters for adjusting Output frequency, Voltage, etc Function group Application parameters of PID operation, The 2nd motor setting, etc Input/Output group Parameters to construct the sequence such as Multi-function terminal setting, etc ● Shifting between groups is possible only in the first code of each group ◀) Shift by using Left shift key (◀ ▶) Shift by using Right shift key (▶ (1) (1) (1) The value of the Command frequency will be displayed in the first code of the Drive group It will show the value set by the operator The factory set value is 0.0 09 Program parameters � Parameter navigation in Drive group � Procedure to set command frequency in Drive group To input new command frequency 30.05[Hz] from 0.0 set in the factory ∙The first code “0.0” displayed ∙Press pro/ent(● ●) key ∙The digit of the first decimal place can be changed ∙Press right (▶ ▶) key ∙The digit of the second decimal place can be changed ∙Press up(▲ ▲) key until the digit becomes ∙Press left(◀ ◀) key ∙The left digit can be set ∙Press left(◀ ◀) key ∙Press left(◀ ◀) key ∙Though 00.0 is displayed, the actual value remains at 0.05 ∙Make by pressing up(▲ ▲) key ∙Press pro/ent(● ●) key ∙30.0 is flickering ∙Press pro/ent(● ●) key to stop the flickering ∙Command frequency 30.0 is stored Note : (1) The LCD on the keypad of Drive iC5 displays only digits ◀ ▶) to monitor and set the parameters Use the shift keys (◀ (2) To cancel the parameter setting press the shift keys ◀ or ▶) while 30.0 is flickering in the procedure no (◀ 10 ∙The first code “0.0” displayed ∙Press up(▲ ▲) key once to move to next code ∙The second code “ACC” appears ∙Press up(▲ ▲) key once to move to next code ∙The third code “dEC” is shown ∙Press up(▲ ▲) key to move to next code ∙To move to the last code press up(▲ ▲) key until “drC” appears ∙Press up(▲ ▲) key once more to return to the first code ∙To move in reverse order use down(▼ ▼) key Program parameters descriptions Drive group Keypad display 0.00 ACC DEC Output frequency : during run Reference frequency : during stop Acceleration time Deceleration time Drv Drive mode Frq Frequency mode St1 St2 St3 Cur RPM DCL v0L/P0r/t0r n0n FU1 group Description Step frequency Step frequency Step frequency Output current Motor speed DC voltage User display selection Fault display drC Motor direction set FU1 FU2 I/O F0 Function Group selection Function Group selection I/O Group selection Jump to desired code # F3 Run prevention F5 Acceleration pattern F6 Deceleration pattern F7 Stop mode F8 F9 F10 F11 F12 F13 F14 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 DC injection braking frequency DC injection braking ON-delay DC injection braking voltage DC injection braking time Starting DC injection braking voltage Starting DC injection braking time Motor exciting time Jog frequency Maximum frequency Base frequency Starting frequency Frequency limit selection Frequency limit - high Frequency limit - low Manual/Auto torque boost selection Torque boost in forward direction Torque boost in reverse direction F30 Volts/Hz pattern Setting range Factory default Adjustable during run to Max frequency[Hz] 0.00 Yes to 6000 [sec] to 6000 [sec] 0(Keypad) 1(Fx/Rx-1) 2(Fx/Rx-2) 3(ModBus) 0(Keypad-1) 1(Keypad-2) 2(Volume) 3(V1) 4(I) 5(Volume+1) 6(V1+I) 7(Volume+V1) 8(ModBus) to Max frequency[Hz] to Max frequency[Hz] to Max frequency[Hz] *[A] *[rpm] *[V] * * F(Forward) R(Reverse) 10 Yes Yes No No 10.00 20.00 30.00 * * * * * Yes Yes Yes * * * * * F Yes * * * Yes Yes Yes Yes No No No No 0.1 50 50 10 60 60 0.5 60 0.5 5 No No No No No No No No No No No No No No No No No No to 60 0(None) 1(Forward disable) 2(Reverse disable) 0(Linear) 1(S-curve) 0(Linear) 1(S-curve) 0(Decel) 1(Dc-brake) 2(Free-run) F23 to 60[Hz] to 60 [sec] to 200[%] to 60 [sec] to 200[%] to 60 [sec] to 60 [sec] to 400 [Hz] 40 to 400 [Hz] 30 to Max frequency[Hz] to 10 [Hz] 0(No), 1(Yes) to High limit [Hz] Low limit to Max frequency[Hz] 0(Manual), 1(Auto) 0.0 to 15.0[%] 0.0 to 15.0[%] 0(Linear) 1(Square) 2(User V/F) 11 Program parameters descriptions FU1 group FU2 group Keypad display Description Setting range Factory default Adjustable during run F31 F32 F33 F34 F35 F36 F37 F38 F39 F40 F50 F51 F52 User V/F - frequency User V/F - voltage User V/F - frequency User V/F - voltage User V/F - frequency User V/F - voltage User V/F - frequency User V/F - voltage Output voltage adjustment Energy save Electronic thermal selection Electronic thermal level -1 Electronic thermal level -continuous 15 25 30 50 45 75 60 100 100 0 150 100 No No No No No No No No No Yes Yes Yes Yes F53 Motor cooling system Yes F54 F55 F56 F57 F58 Overload alarm level Overload alarm hold time Overload trip selection Overload trip level Overload trip delay time 150 10 180 60 Yes Yes Yes Yes Yes F59 Stall prevention mode selection 000 No F60 H0 H1 H2 H3 H4 H5 H6 H7 H8 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H20 H21 Stall prevention level Jump to desired code # Previous fault history Previous fault history Previous fault history Previous fault history Previous fault history Delete fault history Dwell frequency Dwell time Selection of jump frequency Jump frequency 1, low Jump frequency 1, high Jump frequency 2, low Jump frequency 2, high Jump frequency 3, low Jump frequency 3, high Inclination at the beginning of S curve Inclination at the end of S curve Output phase loss protection Power ON start selection Restart after fault reset to F33[Hz] to 100[%] F31 to F35[Hz] to 100[%] F33 to F37[Hz] to 100[%] F35 to Maximum frequency[Hz] to 100[%] 40.0 to 110.0[%] to 30[%] 0(No), 1(Yes) F52 to 200[%] 50 to F51[%] 0(self cool) 1(forced cool) 30 to 150[%] to 30[sec] 0(No), 1(Yes) 30 to 200[%] to 60[sec] 000 to 111(bit set) Bit : During accel Bit : During steady speed Bit : During decel 30 to 150[%] to 95 150 nOn nOn nOn nOn nOn 0 10 15 20 25 30 35 40 40 0 No Yes * * * * * Yes No No No No No No No No No No No Yes Yes Yes H22 Speed search selection No H23 H24 H25 H26 H27 H30 H31 H32 H33 H34 H36 Speed search current limitation level Speed search P gain Speed search I gain Number of auto restart attempt Delay time before auto restart Motor power rating selection Number of motor poles Rated motor slip Rated motor current in RMS No load motor current in RMS Motor efficiency 100 100 1000 * * * * * Yes Yes Yes Yes Yes No No No No No No 0(No), 1(Yes) to Max frequency[Hz] to 10[sec] 0(No), 1(Yes) to H12[Hz] H11 to Maximum frequency[Hz] to H14[Hz] H13 to Maximum frequency[Hz] to H16[Hz] H15 to Maximum frequency[Hz] to 100[%] to 100[%] 0(No), 1(Yes) 0(No), 1(Yes) 0(No), 1(Yes) 0000 to 1111(bit set) Bit : During accel Bit : After fault reset Bit : Restarted after instant power failure Bit : When H20 is set to 1(Yes) to 200[%] to 9999 to 9999 to 10 to 60[sec] 0.2, 0.75, 1.5, 2.2[kW] to 12 to 10[Hz] to 20[A] 0.1 to 20[A] 70 to 100[%] 12 Program parameters descriptions FU2 group Keypad display H37 H39 H40 H41 H42 H44 H45 H46 H50 H51 H52 H53 H54 H55 H70 H71 H72 H73 H74 H79 H81 H82 H83 H84 H85 H86 H87 H88 H89 H90 H93 H94 H95 Description Setting range Load inertia Carrier frequency to to 15[kHz] 0(V/F) 1(Slip compen) Control mode selection 2(PID) 3(Sensorless vector control) Auto tuning to Stator reristance to [ߟ] Leakage inductance to 300[mH] Sensorless P gain to 32767 Sensorless I gain to 32767 0(I) PID feedback signal selection 1(V1) P gain for PID control to 999.9[%] I gain for PID control 0.1 to 32.0[sec] D gain for PID control 0.1 to 30.0[sec] F gain for PID control to 999.9[%] Limit frequency for PID control to Max frequency[Hz] 0(Max freq.) Reference frequency for Accel/Decel 1(Delta freq.) 0(0.001sec) Accel/Decel time scale 1(0.01sec) 2(1sec) 0(Command frequency) 1(Accel Time) 2(Decel Time) 3(Drive mode) 4(Frequency mode) 5(Step frequency 1) 6(Step frequency 2) Power On display 7(Step frequency 3) 8(Current) 9(Speed) 10(DC link voltage) 11(User display) 12(Fault display) 13(Motor direction) 0(Voltage) User display selection 1(Watt) 2(Torque) Gain for motor speed display to 1000[%] Software version x.xx 2nd acceleration time to 6000 [sec] 2nd deceleration time to 6000 [sec] 2nd acceleration time 30 to Max frequency[Hz] 0(Linear) 2nd V/F pattern 1(Square) 2(User V/F) 2nd forward torque boost 0.0 to 15.0[%] 2nd reverse torque boost 0.0 to 15.0[%] 2nd stall prevention level 30 to 150[%] 2nd electronic thermal level -1 H89 to 200[%] 2nd electronic thermal level -continuous 50 to H88[%] 2nd motor rated current 0.1 to 20[A] 0(No) 1(All groups) 2(Drive) Parameter initializing 3(Function 1) 4(Function 2) 5(I/O) Parameter writing protection to FFF Parameter change protection to FFF 13 Factory default Adjustable during run 3.0 No Yes No 0 1000 100 Yes Yes Yes Yes Yes No 300 0 60 Yes Yes Yes Yes Yes Yes No Yes Yes 100 x.xx 10 60 Yes * Yes Yes No No 5 150 150 100 * No No No Yes Yes No No 0 Yes Yes Program parameters descriptions I/O group Keypad display Description Setting range Factory default Adjustable during run I0 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 Jump to desired code # Filtering time constant for V0 signal input V0 input minimum voltage Frequency corresponding to I2 V0 input maximum voltage Frequency corresponding to I4 Filtering time constant for V1 signal input V1 input minimum voltage Frequency corresponding to I7 V1 input maximum voltage Frequency corresponding to I9 Filtering time constant for I signal input I input minimum current Frequency corresponding to I12 I input maximum current Frequency corresponding to I14 10 0.0 10 60.0 10 0.0 10 60 10 20 60.0 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes I16 Criteria for analog speed signal loss Yes I20 Definition of multifunction input terminal P18, 9, 15, 20, 21, 22, 23, 24, 25, 26 ( - reserved - ) 0(FX) Yes I21 I22 I23 I24 I25 I26 I27 I30 I31 I32 I33 I34 I35 I36 I37 I38 I39 I40 I41 I42 Definition of multifunction input terminal P2 Definition of multifunction input terminal P3 Definition of multifunction input terminal P4 Definition of multifunction input terminal P5 Terminal input status Terminal output status Filtering time constant for multifunction input terminal Step frequency Step frequency Step frequency Step frequency Acceleration time Deceleration time Acceleration time Deceleration time Acceleration time Deceleration time Acceleration time Deceleration time Acceleration time to 63 to 9,999[msec] to 10V to 400 [Hz] to 10V to 400 [Hz] to 9,999[msec] to 10V to Max frequency[Hz] to 10V to Max frequency[Hz] to 9,999[msec] to 20[mA] to Max frequency[Hz] I12 to 20[mA] to Max frequency[Hz] 0(None) 1(Half of x1) 2(Below x1) 0(FX) 1(RX) 2(BX) 3(RST) 4(JOG) 5(Speed-L) 6(Speed-M) 7(Speed-H) 8(XCEL-L) 9(XCEL-M) 10(XCEL-H) 11(DC-Brake) 12(2nd function) 15(Up) 16(Down) 17(3 wire) 18(EXT-A) 19(EXT-B) 21(Open-loop) 22(Main drive) 23(Analog hold) 24(XCEL-stop) Same as above I20 Same as above I20 Same as above I20 Same as above I20 00000-11111[bit] 00-11[bit] to Max frequency[Hz] to Max frequency[Hz] to Max frequency[Hz] to Max frequency[Hz] to Max frequency[Hz] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] 1(RX) 2(EST) 3(RST) 4(JOG) * * 15 30 25 20 15 3 4 5 6 Yes Yes Yes Yes * * Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 14 Program parameters descriptions I/O group Keypad display I43 I44 I45 I46 I47 I50 I51 I52 I53 I54 I55 I56 I60 I61 I62 I63 Description Setting range Deceleration time Acceleration time Deceleration time Acceleration time Deceleration time to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] to 600 [sec] 0(Frequency) 1(Current) AM output 2(Voltage) 3(DC link voltage) AM output adjustment 100 to 200[%] Frequency detection level to Max frequency[Hz] Frequency detection bandwidth to Max frequency[Hz] 0(FDT-1) 1(FDT-2) 2(FDT-3) 3(FDT-4) 4(FDT-5) 5(OL) 6(IOL) 7(Stall) Definition of multifunction 8(OV) output terminal MO 9(LV) 10(OH) 11(Lost command) 12(Run) 13(Stop) 14(Steady) 15(Search) 16(Ready) 17(Fault select) Definition of relay functions Same as above I54 000 to 111(bit set) Fault relay setting Bit : Low voltage (30A, 30B, 30C) Bit : Trip Bit : Number of auto retry Inverter number to 32 0(1200bps) 1(2400bps) Baud rate 2(4800bps) 3(9600bps) 4(19200bps) 0(None) Operating selection at loss of freq reference 1(Free run) 2(Stop) Waiting time after loss of freq reference 0.1 to 12[sec] 15 Factory default Adjustable during run 8 9 Yes Yes Yes Yes Yes Yes 100 30 10 Yes Yes Yes 12 Yes 17 Yes 010 Yes Yes Yes Yes 1.0 Yes Checking & Troubleshooting Warning : If protection function activates due to error/fault in the inverter, corresponding alarm is displayed on the keypad as shown below Correct the error/fault before restarting or it may decrease the inverter’s life expectancy Display Fault/Error Overcurrent Ground fault Inverter overload Overload trip Coolingpin overheat Description Output current has been greater than 200% of the rated current The inverter output is interrupted Ground fault has been occurred at the load side of the inverter The inverter output is interrupted Output current greater than 150% of the rated current has been flowed over The inverter output is interrupted Output current has been greater than the set value (F57) of the rated current The inverter output is interrupted Cooling pin has been overheated due to high ambient temperature The inverter output is interrupted DC link condenser overload If the DC condenser of Inverter is in need of replacement the inverter output is interrupted Output phase loss One or more of output line U, V and W lost The inverter output is interrupted Overvoltage The inverter main voltage has been risen above the permissible limit 400V Check if deceleration time has been set too short or line input voltage is too high Undervoltage The inverter output is interrupted Electronic thermal Parameter store error Hardware error Communication error Coolingfan error Output instant interrupting The inverter output is interrupted according to the set time-inverse curve to prevent the overtemperature of the motor due to overloads Error has been occurred on the storing of the changed parameters It is displayed when power is on It is displayed in case of software error It is not possible to reset by STOP/RST key on the keypad or reset terminals Open the inverter power and make sure the keypad power is off and close the power again Communication error between controller and keypad It is not possible to reset by STOP/RST key on the keypad or reset terminals Open the inverter power and make sure the keypad power is off and close the power again Error has been occurred on the coolingfan The inverter output is interrupted in the case that BX terminal is ON Warning : To restart the drive make BX terminal OFF during the FX /RX is ON A contact fault signal input If I20/21/22/23/24 set to 18 is ON, the inverter output is interrupted B contact fault signal input If I20/21/22/23/24 set to 19 is ON, the inverter output is interrupted Frequency command loss If signal input is failed for the driving by using analog input or option(RS485), try to drive according to the setting at I62 16 Checking & Troubleshooting Fault/Error Solution Possibsle cause ● Accel/Decel time is not enough for the load inertia Overcurrent ● The load is greater than the rating of the inverter Ground fault Inverter overload Overload trip Output phase loss ▶ Verify the output wiring ● The motor brake operates too fast ▶ Verify the mechanical brake ● Ground fault at the load side of the inverter ▶ Check to see if there is something wrong with output wiring ● Insulation of the motor is broken ▶ Replace a motor ● The load is greater than the rating of the inverter ▶ Increase the ratings of a motor and an inverter ● Power rating is set to the lower value than the load ▶ Check to see if the setting is correct ● Torque boost is too great ▶ Reduce the torque boost ▶ Check to see if there is any alien substance in the ventilation ● The cooling fan is used beyond the life expectancy ● High ambient temperature Overvoltage ● Fault in the load side contactor ▶ Replace the contactor ● Wiring problem ▶ Verify the output wiring ▶ Check to see if there is any alien substance in the ● The cooling fan is used beyond the expectancy ventilation system ▶ Replace the cooling fan ● Decel time is not enough for the load inertia(GD2) ▶ Increase the Decel time ● There is a survived load in the load side ▶ Uase DB unit ● Higher voltage than rating is supplied ▶ Verify the power voltage ● Lower voltage than rating is supplied ● Power capacity is not enough for the additional Undervoltage loads like welders and direct-on-line starting motors ● Fault in the line side contactor ▶ Verify the power voltage ▶ Increase the power capacity ▶ Replace the contactor ▶ Reduce the load or operation times ● Overtemperature of the motor ● The load is greater than the rating of the inverter Electronic thermal system ▶ Replace the cooling fan ▶ Keep the ambient temperature below 40°… ● Alien substances are in the ventilator Coolingfan error in the output terminals ● Inverter output is assigned during the free run of the motor ● Fault in the cooling system Cooling fan overheat ▶ Replace the inverter with a higher rating ▶ Operate after the motor stops or use speed search(H22) in FU2 (GD2) Increase the Accel/Decel time ● Electronic thermal level is set lower than rating ● Inverter power rating is set to the lower value than the load ● Long operation at low speed ▶ Increase the ratings of the inverter ▶ Adjust the electronic thermal properly ▶ Adjust the inverter rating properly ▶ Replace the motor with the separated power cable for the cooling fan A contact fault signal input ● The terminal I20/21/22/23/24 set to18/19 is ON Verify the circuits connected to the external fault terminals B contact fault signal input Frequency command loss ● Frequency command loss at terminals V1 and I Parameter store error Output instant interrupting ● Refer to LS or distributors Communication error 17 Verify the wiring connected to V1 and I terminals Tips on Installation Warning : Carefully read the instruction for installation and wiring of inverters and relevant devices Normal operation is impossible in case of the improper system design and wiring These can shorten the life of the inverter and damage it at the worst INDUCTORS FOR VARIABLE SPEED DRIVES The inductors manufactured with special magneticcores are advisable for location: BETWEEN MAINS AND VARIABLE SPEED DRIVE, in order to protect the equipment from overvoltages, voltage surges and also to limit the line current and the harmonics generated by VSD BETWEEN VARIBLE SPEED DRIVE AND MOTOR, to absorb the voltage peaks in the motor terminals, when the connection cables are long or there are more than one motor in parallel, for having a better efficiency and to eliminate the humming noise of the motor POWER LINE FILTERS The family of filters manufactured by LIFASA has been specially developed and approved for its application with variable speed drives, to assure the compliance of the EMC (Electro Magnetic Compatibility) and the LV safety European Directives, in both industrial and domestic environments VARIABLE SPEED DRIVES �Powers from 0.37 to 375 kW �Sngle/three phase voltages 220/230 Vac �Three phase voltages 380/460 Vac �Sensorless vector control, V/F closed loop �Removable console with copy function �RS485 communication facilities as standard �Autotuning �Special parameters for special applications OUTPUT LC FILTERS The commutation of the IGBT's at high frequency (PWM) provokes an output voltage with peaks up to 1300 V The LC filter - low pass - reduce the dV/dt converting the voltage in a sinus waveform, eliminating all the isolation problems in the motor and the emission of interference from the cables M ※ Filter for use of LS Inverters : Vector Motor Control Ib’erica (VMC) C/Mar del Carib, 10 - Pol Ind La Torre del Rector 08130 - Santa Perp`etua de Mogoda (Barcelona) - SPAIN Tel: (+34) 935 748 206 - Fax: (+34) 935 748 248 e-mail: info@vmc.es - www.vmc.es 18 � For your safety, please read user's manual thoroughly before operating � Contact the nearest authorized service facility for examination, repair, or adjustment � Please contact qualified service technician when you need maintenance Do not disassemble or repair by yourself! Safety Instructions � Any maintenance and inspection shall be performed by the personnel having expertise concerned ⓒ 2003.2 LS Industrial Systems Co.,Ltd All rights reserved www.lsis.biz � HEAD OFFICE � Global Network LS Tower 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 431-848, Korea � Asia Pacific & America +82-2-2034-4901 / bonseongk@lsis.biz � Europe & CIS +82-2-2034-4376 / ywsohn@lsis.biz � Meddle East & Africa +82-2-2034-4645 / sungkyup@lsis.biz �LS Industrial Systems (Middle East) FZE � �Dubai, U.A.E �Dalian LS Industrial Systems Co., Ltd � �Dalian, China Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn �LS Industrial Systems (Wuxi) Co., Ltd � �Wuxi, China Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: xuhg@lsis.com.cn �LS-VINA Industrial Systems Co., Ltd � �Hanoi, Vietnam Worldwide Address: 1st Floor, Tupolevlaan 48, 1119NZ Schiphol-Rijk, The Netherlands Tel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: junshickp@lsis.biz Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O Box 114216, Dubai, United Arab Emirates Tel: 971-4-886 5360 Fax: 971-4-886-5361 e-mail: jungyongl@lsis.biz � �LS Industrial Systems Europe B.V � �Amsterdam, Netherland +82-2-2034-4672 / bskoo@lsis.biz Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: srjo@lsisvina.com �LS-VINA Industrial Systems Co., Ltd � �Hochiminh , Vietnam Address: 41 Nguyen Thi Minh Khai Str Yoco Bldg 4th Floor, Hochiminh City, Vietnam Tel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: sbpark@lsisvina.com �LS Industrial Systems Tokyo Office � �Tokyo, Japan Address: 16FL, Higashi-Kan, Akasaka Twin Tower 17-22, 2-chome, Akasaka, Minato-ku Tokyo 107-8470, Japan Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: jschuna@lsis.biz �LS Industrial Systems Shanghai Office � �Shanghai, China Address: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R China Tel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: jinhk@lsis.com.cn �LS Industrial Systems Beijing Office � �Beijing, China Address: B-Tower 17FL.Beijing Global Trade Center B/D No.36, BeiSanHuanDong-Lu, DongCheng-District, Beijing 100013, P.R China Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: cuixiaorong@lsis.com.cn �LS Industrial Systems Guangzhou Office � �Guangzhou, China Address: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R China Tel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: linsz@lsis.biz �LS Industrial Systems Chengdu Office � �Chengdu, China Address: Room 1701 17Floor, huanminhanjun internationnal Building, No1 Fuxing Road Chengdu, 610041, P.R China Tel: 86-28-8670-3101 Fax: 86-28-8670-3203 e-mail: yangcf@lsis.com.cn Specifications in this catalog are subject to change without notice due to continuous product development and improvement 2010 05 �LS Industrial Systems Qingdao Office � �Qingdao, China Address: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R China Tel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: lirj@lsis.com.cn Starvert iC5 (E) 2003 2/(12) 2010 05 Printed in Korea STAFF ... Filtering time constant for multifunction input terminal Step frequency Step frequency Step frequency Step frequency Acceleration time Deceleration time Acceleration time Deceleration time Acceleration... overheat ▶ Replace the inverter with a higher rating ▶ Operate after the motor stops or use speed search(H22) in FU2 (GD2) Increase the Accel/Decel time ● Electronic thermal level is set lower... To operate the drive To stop operating or reset in case of fault To change parameters and save them To change the frequency Mode selection between NPN and PNP To increase the parameter values To

Ngày đăng: 13/11/2022, 21:29

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN