balloon valvotomy in infants with critical pulmonary stenosis or membranous pulmonary atresia with intact ventricular septum J Am Coll Cardiol 1995;25:460–465 63 McCrindle BW Independent predictors of longterm results after balloon pulmonary valvuloplasty: Valvuloplasty and Angioplasty of Congenital Anomalies (VACA) Registry Investigators Circulation 1994;89:1751–1759 64 Robida A, Pavcnik D Perforation of the heart in a newborn with critical valvar pulmonary stenosis during balloon valvoplasty Int J Cardiol 1990;26:111–112 65 Burrows PE, Benson LN, Moes CA, Freedom RM Pulmonary artery tears following balloon valvotomy for pulmonary stenosis Cardiovasc Intervent Radiol 1989;12:38–42 66 Stanger P, Cassidy SC, Girod DA, et al Balloon pulmonary valvuloplasty: results of the Valvuloplasty and Angioplasty of Congenital Anomalies Registry Am J Cardiol 1990;65:775–783 67 Harrild DM, Powell AJ, Tran TX, et al Longterm pulmonary regurgitation following balloon valvuloplasty for pulmonary stenosis risk factors and relationship to exercise capacity and ventricular volume and function J Am Coll Cardiol 2010;55(10):1041–1047 68 Petit CJ, Glatz AC, Qureshi AM, et al Outcomes after decompression of the right ventricle in infants with pulmonary atresia with intact ventricular septum are associated with degree of tricuspid regurgitation: results from the Congenital Catheterization Research Collaborative Circ Cardiovasc Interv 2017;10(5) 69 Bonhoeffer P, Boudjemline Y, Saliba Z, et al Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction Lancet 2000;356:1403–1405 70 Martin MH, Shahanavaz S, Peng LF, et al Percutaneous transcatheter pulmonary valve replacement in children weighing less than 20 kg Catheter Cardiovasc Interv 2017 [Nov 29] 71 Shahanavaz S, Qureshi AM, Levi DS, et al Transcatheter pulmonary valve replacement with the melody valve in small diameter expandable right ventricular outflow tract conduits JACC Cardiovasc Interv 2018;11(6):554–564 72 Cheatham SL, Holzer RJ, Chisolm JL, Cheatham JP The medtronic melody® transcatheter pulmonary valve implanted at 24-mm diameter– it works Catheter Cardiovasc Interv 2013;82(5):816–823 73 Haas NA, Moysich A, Neudorf U, et al Percutaneous implantation of the edwards SAPIEN(™) pulmonic valve: initial results in the first 22 patients Clin Res Cardiol 2013;102(2):119–128 74 Kenny D, Hijazi ZM, Kar S, et al Percutaneous implantation of the edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position: early phase 1 results from an international multicenter clinical trial J Am Coll Cardiol 2011;58(21):2248–2256 75 Morray BH, McElhinney DB, Cheatham JP, et al Risk of coronary artery compression among patients referred for transcatheter pulmonary valve implantation: a multicenter experience Circ Cardiovasc Interv 2013;6(5):535–542 76 McElhinney DB, Cheatham JP, Jones TK, et al Stent fracture, valve dysfunction, and right ventricular outflow tract rein-tervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial Circ Cardiovasc Interv 2011;4(6):602–614 77 Cabalka AK, Hellenbrand WE, Eicken A, et al Relationships among conduit type, Pre-stenting,