1. Trang chủ
  2. » Ngoại Ngữ

In Situ Measurements of the Coefficient of Friction and Drag Forces during Chemical Mechanical Planarization

8 4 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Nội dung

In Situ Measurements of the Coefficient of Friction and Drag Forces during Chemical Mechanical Planarization *, James Vlahakis Caprice Gray*, Chris Barns+, Moinpour Monsour+, Sriram Anjur`, Ara Philliposian^, Vincent Manno*, and Chris Rogers* * Tufts University, Medford, MA Intel Corporation, Santa Clara, CA `Cabot Microelectronics, Aurora, IL ^University of Arizona, Tucson, AZ + Principal Contact: James Vlahakis, Tufts University Email: James.Vlahakis@tufts.edu Abstract The semiconductor industry utilizes chemical mechanical planarization (CMP) as an essential component in wafer processing We employ a new technique for determining the friction forces that develop during CMP using an AMTI MC12 force platform sensor and custom LabView software, allowing in situ measurements of interfacial drag forces and the coefficient of friction (COF) Spectrum analysis of the drag forces and coefficient of friction reveal interesting features that vary depending upon rotational speed, pad type, and process downforce The essential elements of CMP are the polishing pad, the wafer, and the slurry The friction measurements result from the interaction of all three elements, both through direct loading and shear loading Introduction The semiconductor industry utilizes chemical mechanical planarization (CMP) as an essential component in wafer processing As microelectronic feature sizes continue to shrink, the ability to planarize various substrates over wide ranging length scales becomes an essential element of the manufacturing process In order to gain some insight and understanding into the material removal mechanisms and planarization performance, we examine the forces generated during CMP These interfacial shear forces have a direct influence on material removal rates, temperature variations, and failure modes Consequently, the investigation of these forces as a function of these, and other, parameters has been an area of keen interest to researchers in the last few years Shear force measurements present several advantages Primarily, these interfacial forces are measured in situ, rather than through indirect means This gives a clearer picture of the mechanisms involved Our technique allows us to sample the forces at sampling frequencies of 2kHz Most previous studies examined time-averaged, mean shear force These time averaging techniques not capture the interfacial forces generated by stick/slip phenomena and other vibrational modes In addition, the instantaneous, in situ shear force measurements allow us to determine the instantaneous, in situ coefficient of friction (COF) We describe a technique for measuring interfacial forces and determining the COF In addition, we explore how variations in slurry flow, process downforce, and polishing pad effect the data Our technique utilizes an AMTI axis force platform, a Struers ½ scale laboratory polisher, and custom LabView software Experimental Overview Various polishing parameters are adjusted to account for laboratory research scaling and the optical measurements required for our concurrent DELIF experiments.[1], [2] It is necessary to replace the traditional opaque silicon wafer with a transparent BK-7 glass wafer to enable our DELIF measurements The slurry used during conditioning is a 9:1 water dilution of Cabot Microelectronics’ Cab-O-Sperse SC-1 3.1 wt% abrasive The dilution of the slurry is necessary to maintain a consistent shape of the BK-7 wafer during the polishing run A magnetic stir bar constantly stirs the slurry in order to discourage aggregation of the silica nano-particles and a peristaltic pump delivers the slurry to the pad at a rate of 50 cc per minute The laboratory CMP equipment is scaled down from an industrial CMP system by a factor of A summary of these adjustments are listed in Table Table Industrial to Laboratory Scaling Adjustments Adjustment Parameter Held Constant Wafer Diameter (Pad area)/ (Wafer area) Pad and Wafer (Relative Industrial Linear Velocity)/ Rotation Velocity (Relative Laboratory Linear Velocity) Slurry Flow Rate Flow rate/[(Pad Area)*(wafer position)*(pad rotation velocity)] Lab Scale Dimensions 3” 60 RPM 50cc/min AMTI Force Platform [2] The force platform measures the forces on the surface of the platform and decomposes the loading into orthogonal component forces and moments – Fx, Fy, Fz, Mx, My, and Mz A right handed coordinate system is utilized with the positive z-axis pointing downwards The platform surface measures 12” x 12” consists of 7075-T6 aluminum and is equipped with numerous threaded inserts to facilitate attachment to various experimental set-ups The transducer incorporates strain gages and four precision elements in a patented design to isolate and measure applied forces and moments Multiple channel bridge excitation and signal amplification are provided by an AMTI amplifier We utilize our own custom LabView software to control the force platform/amplifier settings and collect data See Figure Figure – Force Platform CMP Polisher We employ a Struers RotoPol 31 as our table top polisher It rests directly on top of the force platform and allows real time measurements of the forces of the wafer and pad interacting, whether in the Z (applied pressure) or the X and Y directions (friction due to polishing) The polisher's platen is fitted with 12 inch diameter polishing pads Again, our experiments require a inch by ½ inch thick BK-7 glass wafer in place of the industry standard silicon wafer The wafer's applied pressure and rotation are controlled by an aluminum shaft pressing the wafer into the pad The shaft is held in place by two linear bearings that allow the shaft to rotate as well as slide to apply pressure A 1/2 hp Dayton motor rotates the shaft, and a series of weights can be utilized to vary the process downforce The shaft and motor are held above the polisher by a custom 80/20 extruded aluminum support frame The entire structure is mounted on a 136kg solid steel isolation table Figure summarizes the experimental setup Motor Wafer Platen Steel Table RotoPol-31 Force Table Figure - Experimental setup The experimental work presented here builds on CMP research conducted at Tufts since 1995 If the reader desires a more detailed description of the experimental set-up, please refer to [3] In the experiments under consideration, we varied several parameters; Downforces - 2.5psi (low Fz) and 5psi (high Fz) Polishing speeds - 30rpm and 60rpm Polishing pads – an ungrooved FX9, an FXP with circular grooves and an IC1000 with xy grooves In addition, the IC1000 was tested for both normal and low slurry flow rate conditions Each pad was conditioning for at least 20 minutes before data logging We sampled forces and moments at a rate of 2kHz In addition, a 500Hz Bessel filter was employed to reduce aliasing The standard slurry flow rate was maintained at 50cc/min In the low slurry flow rate case, we set the rate to 25cc/min Results and Discussion Data set summary; • • • • Data Set – ungrooved Freudenberg FX9 pad Data Set – circular grooved Freudenberg FX9 pad Data Set – xy grooved Rodell IC1000 pad Data Set – xy grooved Rodell IC1000 pad at a lower slurry flow rate Overall, the COF values are in agreement with previous data collected here at Tufts.[4] The ungrooved FX9 exhibits much higher coefficient of friction (COF) values, and much higher standard deviations, than the grooved pads In fact, even though the average COF values are ~0.8, instantaneous COF values can range has high as 3.0 and as low as 0.0 These widely disparate values indicate different lubrication regimes – lower values are clearly hydrodynamic, while higher values could be interpreted as a mixed or boundary lubrication regime The grooved pads at the standard slurry flow rate exhibit some common features, the most prominent being much smaller COF’s, varying from 0.36 to 0.47 In addition, the COF standard deviations are much smaller than the ungrooved pad, varying from 0.05 to 0.08 It appears the venting allowed by the grooved pads serves to limit the swings between different lubrication regimes that we saw in the ungrooved pad The low slurry flow rate appears to have some features of both the grooved and ungrooved data First of all, we see greater COF’s, 0.42 to 0.62, than in the grooved pads However, we not see large, instantaneous COF values that approach 3.0 as we did in the ungrooved pad In addition, the standard deviations in the COF data, 0.04 to 0.10, are similar to the grooved pads, indicating that, once again, the venting serves to “damp out” radical variations in the COF In the meantime, the relative lack of slurry slightly increases the average COF in the low downforce cases In the high downforce cases, the average COF’s are essentially the same Future Work We plan to continue exploring various parameter regimes using our existing experimental setup In addition, we hope to apply other analytical techniques to the data, specifically, frequency analysis References C Gray, et al, Instantaneous, High Resolution, In-situ Imaging of Slurry Film Thickness During CMP, 2004 CMP-MIC Symposium paper D Apone, Instantaneous Fluid Film Imaging in CMP, Master’s Thesis, Tufts University, April 2005 Force Platform specifications provided by AMTI, Watertown Massachusetts C Gray, et al, In-Situ Friction and Pad Topography Measurements During CMP, Spring 2004 Materials Research Society Symposium paper J Lu, et al, Measurements of Slurry Film Thickness and Wafer Drag During CMP, Journal of the Electrochemical Society, 151 (4) 2004 Data Set – Ungrooved FX9 pad Data Set – circular grooved FX9 pad Data Set – xy grooved IC1000 pad Data Set – xy grooved pad, low slurry flow rate ... and allows real time measurements of the forces of the wafer and pad interacting, whether in the Z (applied pressure) or the X and Y directions (friction due to polishing) The polisher's platen... once again, the venting serves to “damp out” radical variations in the COF In the meantime, the relative lack of slurry slightly increases the average COF in the low downforce cases In the high... large, instantaneous COF values that approach 3.0 as we did in the ungrooved pad In addition, the standard deviations in the COF data, 0.04 to 0.10, are similar to the grooved pads, indicating that,

Ngày đăng: 20/10/2022, 04:21

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN

w