Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 24 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
24
Dung lượng
4,57 MB
Nội dung
TIEU LUAN MOI download : skknchat123@gmail.com POWER CONVERTER DESIGN AND ATS AUTO GENERATOR CONTROL (AUTOMATIC TRANSFER SWITCH ) • Phạm Hữu Thanh TEACHER: TS.Nguyễn Trí Cường TIEU LUAN MOI download : skknchat123@gmail.com CONTENT INTRODUCE ALGORITHM DESIGN RESULT CONCLUSIONS AND FUTUREWORK TIEU LUAN MOI download : skknchat123@gmail.com I INTRODUCE During operation, some common problems may occur such as: power failure, phase loss, voltage drop, overvoltage, phase difference, phase imbalance, noise on the line, TIEU LUAN MOI download : skknchat123@gmail.com I INTRODUCE When there is a power outage on the grid, special loads will require an alternate backup power source What is an ATS system? An automatic power transfer device, also known as ATS (Automatic Transfer Switch) is used to automatically transfer the load from the main power source to the backup source when the main source fails and vice versa when the main power is restored or switched intentionally TIEU LUAN MOI download : skknchat123@gmail.com II INTRODUCE ATS structure with main grid – backup generators This construction allows two generators to work alternately or in parallel, resulting in higher power generation efficiency and longer traction motor life TIEU LUAN MOI download : skknchat123@gmail.com II INTRODUCE The following requirements must be followed during operation:: Only startup one to three times each power outage After the engine has successfully operated for to seconds, the starter must be turned off Before putting oil into the combustion chamber of an engine, it must be dried It is vital to avoid repeated beginning when the mains voltage fluctuates or the grid voltage flickers Diesel generator When stopping, you'll need some time to cool off III TIEU LUAN MOI download : skknchat123@gmail.com ALGORITHM DESIGN Auto mode Manual mode TIEU LUAN MOI download : skknchat123@gmail.com III ALGORITHM DESIGN TIEU LUAN MOI download : skknchat123@gmail.com IV RESULT Time diagram in case of power on after hours 10 Time diagram in case of power on after hours Time diagram in case the generators not power up TIEU LUAN MOI download : skknchat123@gmail.com IV RESULT TIEU LUAN MOI download : skknchat123@gmail.com V CONCLUSION AND FUTUREWORK CONCLUSION The results of the performed test ensure the ATS-design’s functioning and compliance with requirements and constraints Our design is appropriate for the subject of Project II and at a cheaper cost FUTURE WORK In future work, we will broaden our approach by incorporating additional features such as display and monitoring on the webserver or the HMI 12 TIEU LUAN MOI download : skknchat123@gmail.com THANK YOU ! 13 Reference [1] E and R Meeks, ”Energy efficiency and electricity reliability,” Review of Economics and Statistics, pp.1-78, 2018 [2] D Stern “Energy quality,” Ecological Economics vol, 69 pp 1471-1478, 2010 [3] N Mohan, Electric Power Systems: A First Course Wiley, 2012 [4] D L Ransom, ”Choosing the Correct Transfer Switch,” IEEE Trans Ind Appl., vol 49, no 6, pp 2820-2824, 2013 [5] H Zheng, Y Cheng, B Gou, D Frank, A Bern, and W E Muston, ”Impact of automatic switches on power distribution system reliability,” Electr Power Syst Res., vol 83, no 1, pp 51-57, 2012 [6] P M Curtis, ”Automatic Transfer Switch Technology, Application, and Maintenance,” in Maintaining Mission Critical Systems in a 24/7 Environment, IEEE, 2007, pp 89-111 [7] B Tian et al., ”400 V/1000 kVA Hybrid Automatic Transfer Switch,” IEEE Trans Ind Electron., vol 60, no 12, pp 5422–5435, 2013 [8] FX3G SERIES PROGRAMMABLE CONTROLLERS HARDWARE MANUAL [9] Everlasting company, ”Operation and Maintenance Manual for Diesel Generator Sets ” [10] R A Simmons and F S Salem, “High voltage automatic transfer switch: going beyond normal distribution solutions”, 9Ih Inter Conf On Harmonics and Quality of Power, Vol 3,2000, pp 882-886 [11] R E Cousy, “Transfer switch ratings ‘without fuses or circuit breakers”, IEEE Trans on Power Delivery, San., 1990, pp.202203 [12] R E Cosse, J E Bowen and W H Nichols, “Is selectivity achieved in critical low-voltage UPS and standby generator power circuits?”, IEEE Trans On Industry Applications, Vol 37, Jul., 2001, pp 1140-1 151 [13] K T Erickson, ”Programmable logic controllers”, IEEE Potentials VoLlS, Feb., 1996, pp 14-17, [14] E A Parr, “Programmable controllers: an engineer’s guide”, Newnes, TIEU LUAN MOI download : skknchat123@gmail1997 com III ALGORITHM DESIGN TIEU LUAN MOI download : skknchat123@gmail.com III ALGORITHM DESIGN TIEU LUAN MOI download : skknchat123@gmail.com I INTRODUCE 16 Power outages have the greatest impact on all economic sectors from agriculture to industry to daily life TIEU LUAN MOI download : skknchat123@gmail.com .. .POWER CONVERTER DESIGN AND ATS AUTO GENERATOR CONTROL (AUTOMATIC TRANSFER SWITCH ) • Phạm Hữu Thanh TEACHER: TS.Nguyễn Trí Cường TIEU LUAN... a power outage on the grid, special loads will require an alternate backup power source What is an ATS system? An automatic power transfer device, also known as ATS (Automatic Transfer Switch) ... Diesel Generator Sets ” [10] R A Simmons and F S Salem, “High voltage automatic transfer switch: going beyond normal distribution solutions”, 9Ih Inter Conf On Harmonics and Quality of Power,