... Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-FOTP-85 Cable length twisted: 2m No. ... ENVIRONMENTAL PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this specification, the following temperature ranges apply: Operation : -2 0°C to +60°C Inst...

Ngày tải lên: 24/01/2014, 02:20

7 185 0
Tài liệu Datasheet - FO - Cable - MultiMode cable Specification pdf

Tài liệu Datasheet - FO - Cable - MultiMode cable Specification pdf

... protection in different environmental conditions. Excellent dimensional control for low splice loss. APPLICATIONS Suitable media for short distance transmission, such as local area network (Ethernet, ... (550 meter for 1000BaseSX and 1000BaseLX application) Numerical Aperture @ 0.200 ± 0.015 Optical Parameters • Attenuation (dB/km) Typical @ 850nm ≤ 3.5 @1300nm ≤ 1.0 • Bandwidth (MHz-km) Typ...

Ngày tải lên: 21/12/2013, 19:15

2 242 0
Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables pdf

Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables pdf

... Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts Flexing: EIA-FOTP-104A 1000 Cycles ... Passes @ 0°C and 70°C Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C -2 0°C to +70°C (OFNR) -2 0°C t...

Ngày tải lên: 16/01/2014, 20:21

2 363 0
Tài liệu Datasheet - FO - Cable - In & Outdoor pdf

Tài liệu Datasheet - FO - Cable - In & Outdoor pdf

... Resistance (EIA-FOTP-41A): 1500 N/cm 1500 N/cm Impact Resistance (EIA-FOTP-25A): 1000 impacts 1000 impacts Flexing (EIA-FOTP-104A): 1000 cycles 1000 cycles Maximum Pulling Load (EIA-FOTP-33A): 1000 ... x cable O.D. 20 x cable O.D. Unloaded: 10 x cable O.D. 10 x cable O.D. Maximum Vertical Rise: 325 meters 325 meters Fiber Proof Test: 100 KPSI 100 KPSI Operating Temperature: -4 0°...

Ngày tải lên: 16/01/2014, 20:21

2 243 0
Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf

Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf

... specification covers the general requirements for fiber optic telecommunication cables used for inter-building backbone in duct installation and lashed aerial use. 1.2 Cable Description 1) Single Jacket/Non ... this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM). Table 5. The Mechanical and Environmental Performance of the Cable ITE...

Ngày tải lên: 24/01/2014, 02:20

7 264 0
Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc

Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc

... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable

Ngày tải lên: 09/12/2013, 15:15

2 430 1
Tài liệu Datasheet - FO - Cable - ThinLITE Zipcord doc

Tài liệu Datasheet - FO - Cable - ThinLITE Zipcord doc

... Pass Pass Pass Cable Knot Test: EIA-FOTP-87B Pass Pass Pass Fiber Proof Test: 100 KPSI 100 KPSI 100 KPSI High/Low Temp. Bend Test: EIA-FOTP-37A — — — Cable Twist Test: EIA-FOTP-85A — — — Operating ... SOLUTIONS ThinLITE™ CABLES Mechanical & Environmental Characteristics Test Single Fiber Duplex Cable Zipcord Crush Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm Impact Resistance...

Ngày tải lên: 09/12/2013, 15:15

2 332 0
Tài liệu Datasheet - FO - Cable - ThinLITET Cables pptx

Tài liệu Datasheet - FO - Cable - ThinLITET Cables pptx

... Pass Pass Pass Cable Knot Test: EIA-FOTP-87B Pass Pass Pass Fiber Proof Test: 100 KPSI 100 KPSI 100 KPSI High/Low Temp. Bend Test: EIA-FOTP-37A — — — Cable Twist Test: EIA-FOTP-85A — — — Operating ... SOLUTIONS ThinLITE™ CABLES Mechanical & Environmental Characteristics Test Single Fiber Duplex Cable Zipcord Crush Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm Impact Resistance...

Ngày tải lên: 10/12/2013, 02:15

2 332 0
Tài liệu Datasheet - FO - Wallmount Module_Box pdf

Tài liệu Datasheet - FO - Wallmount Module_Box pdf

... Fibre-optic Module Box FO- MB 12/24 KRONE GmbH Beeskowdamm 3-1 1 D-14167 Berlin Phone +49 30 845 3-1 422 Telefax +49 30 845 3-1 412 http://www.krone.com vertrieb@krone.com KRONE FiberPLUS ® ■ ... or in-house demarcation point ■ Box with double cover and two locks for seperate access of carrier and customer ■ Pre-assembled FO modules significantly reduce installation time ■ Low costs...

Ngày tải lên: 10/12/2013, 02:15

2 384 0
Tài liệu Datasheet - FO - Cable - 10 Gbs Multi Mode Fiber docx

Tài liệu Datasheet - FO - Cable - 10 Gbs Multi Mode Fiber docx

... Multimode Fiber 850 nm Laser-Optimised 50 µm Multimode Fiber for 10Gb/s Application over 300m KRONE 10 Gb/s multimode fibers are produced by the proprietary Plasma- activated Chemical Vapour ... specified by laser-based launch Specifications: * 10 Gigabit Ethernet distance guarantees at 1300nm are achieved via four 3.125 Gbps channels * multiplexed with WWDM technology (10GBASE-LX4) Guarantee...

Ngày tải lên: 11/12/2013, 13:15