Introduction to Modern Liquid Chromatography, Third Edition part 90 potx

Introduction to Modern Liquid Chromatography, Third Edition part 90 potx

Introduction to Modern Liquid Chromatography, Third Edition part 90 potx

... way to flush particulate matter from the top of the inlet frit and restore normal peak shapes. After reversing the column, flow 20 to 30 mL of solvent through the column to waste (not the detector), ... stream due to partially blocked column-inlet frit. (c) Distortion of sample stream due to void at head of column. 042681210 Time (min) (a) (b) Figure 17.19 Split peaks attributed to...

Ngày tải lên: 04/07/2014, 01:20

10 232 0
Introduction to Modern Liquid Chromatography, Third Edition part 2 potx

Introduction to Modern Liquid Chromatography, Third Edition part 2 potx

... 158 4.3 Introduction to Individual Detectors, 160 4.4 UV-Visible Detectors, 160 4.4.1 Fixed-Wavelength Detectors, 163 4.4.2 Variable-Wavelength Detectors, 164 4.4.3 Diode-Array Detectors, 165 4.4.4 ... 113 3.6 Autosamplers, 113 3.6.1 Six-Port Injection Valves, 114 3.6.1.1 Filled-Loop Injection, 114 3.6.1.2 Partial-Loop Injection, 115 3.6.2 Autosampler Designs, 116 3.6.2.1 Pull -to- Fill A...

Ngày tải lên: 04/07/2014, 01:20

10 369 0
Introduction to Modern Liquid Chromatography, Third Edition part 12 potx

Introduction to Modern Liquid Chromatography, Third Edition part 12 potx

... reasons: • to avoid an undesirable change in separation due to a sample size that is too large • to increase detection sensitivity for trace analysis, by using the largest possible sample size • to maximize ... 1 to 4, the peak begins to widen and then develops a flat top. For Equation (2.27) and the examples of Figure 2.22, we assume the delivery of an undistorted (i.e., cylindric...

Ngày tải lên: 04/07/2014, 01:20

10 277 0
Introduction to Modern Liquid Chromatography, Third Edition part 22 potx

Introduction to Modern Liquid Chromatography, Third Edition part 22 potx

... directed to a photodetector, where it is monitored and converted to an electronic signal for data processing. Because fluorescence is emitted in all directions, it is common to monitor the emitted ... DETECTORS 169 lamp filter or monochromator photocell sample in sample out Figure 4.14 Schematic of a fluorescence detector. Dashed lines show optical path. expensive fluorometers use filters...

Ngày tải lên: 04/07/2014, 01:20

10 308 0
Introduction to Modern Liquid Chromatography, Third Edition part 29 potx

Introduction to Modern Liquid Chromatography, Third Edition part 29 potx

... pack- ing particles. To prevent particle aggregation, the interaction of the particle with the slurry liquid should be stronger than interactions between particles. For example, C 8 -orC 18 -modified particles ... as illustrated by the cartoon of Figure 5.25a, the liquid may be acceptable. However, if the particles tend to aggregate as in Figure 5.25b, the liquid is likely a poor cho...

Ngày tải lên: 04/07/2014, 01:20

10 237 0
Introduction to Modern Liquid Chromatography, Third Edition part 58 potx

Introduction to Modern Liquid Chromatography, Third Edition part 58 potx

... METHOD ADJUSTMENT OR METHOD MODIFICATION, 561 12.8.1 pH Adjustments, 563 Introduction to Modern Liquid Chromatography, Third Edition, by Lloyd R. Snyder, Joseph J. Kirkland, and John W. Dolan Copyright ... UK, 1998. 2. L. R. Snyder and J. J. Kirkland, Introduction to Modern Liquid Chromatography, 2nd ed., Wiley, New York, 1974. 3. V. R. Meyer, J. Chromatogr. Sci., 33 (1...

Ngày tải lên: 04/07/2014, 01:20

10 229 0
Introduction to Modern Liquid Chromatography, Third Edition part 83 potx

Introduction to Modern Liquid Chromatography, Third Edition part 83 potx

... poly-dimethylsiloxane or a polyacrylate [32, 33]. The fiber is dipped into the solution to be analyzed, and analytes diffuse to and partition into the coating as a function of their distribution coefficients. ... or embedded into individual disks. The plate is analogous to a 8 × 12 array of miniaturized SPE cartridges. The plates can be handled by robotic instrumentation to completely a...

Ngày tải lên: 04/07/2014, 01:20

10 131 0
Introduction to Modern Liquid Chromatography, Third Edition part 95 pdf

Introduction to Modern Liquid Chromatography, Third Edition part 95 pdf

... rules, 583–584 structure vs. chromatography, 583–584 Proteomics, multidimensional liquid chromatography, 616–618 Protocol; see Validation, protocol Pseudocritical chromatography, 654 Pump(s), 104–113 active ... U-HPLC High-pressure liquid chromatography, 8 High-priced liquid chromatography; see U-HPLC High-speed liquid chromatography, 8 HILIC, see Hydrophilic interaction chr...

Ngày tải lên: 04/07/2014, 01:20

17 454 0
Introduction to Modern Liquid Chromatography, Third Edition part 1 pdf

Introduction to Modern Liquid Chromatography, Third Edition part 1 pdf

... Hybrid Systems, 111 INTRODUCTION TO MODERN LIQUID CHROMATOGRAPHY Third Edition LLOYD R. SNYDER LC Resources, Inc. Orinda, CA JOSEPH J. KIRKLAND Advanced Materials Technology Wilmington, DE JOHN W. ... Lloyd R. Introduction to modern liquid chromatography / Lloyd R. Snyder, Joseph J. Kirkland. – 3rd ed. / John W. Dolan. p. cm. Includes index. ISBN 978-0-470-16754-0 (cloth)...

Ngày tải lên: 04/07/2014, 01:20

10 630 0
Introduction to Modern Liquid Chromatography, Third Edition part 3 ppsx

Introduction to Modern Liquid Chromatography, Third Edition part 3 ppsx

... 651 13.10.3 Liquid- Chromatography Modes for Polymer Analysis, 653 13.10.3.1 Size-Exclusion Chromatography, 653 13.10.3.2 Interactive Liquid Chromatography, 653 13.10.3.3 Liquid Chromatography under Critical ... RPC- 5 Chromatography, 623 13.5.3 Hydrophobic Interaction Chromatography, 624 13.6 Separation of Carbohydrates, 625 13.6.1 Hydrophilic Interaction Chromatography, 625 1...

Ngày tải lên: 04/07/2014, 01:20

10 299 0
w