Function code schedule graph especially for drawing machine

Một phần của tài liệu Tài liệu biến tần ENC EDS1000 manual (Trang 149 - 154)

Appendix 1 EDS1100 drawing machine inverter manual

4.1 Function code schedule graph

4.1.1 Function code schedule graph especially for drawing machine

Telecommunication serial No. is the function code address when computer communicates.

F0 Basic run function parameter group Function

code Name Parameter setting Unit Factory

default Modificati

on

F0.00 Frequency input channel selection

0 keyboard analog potentiometer setting 1 operation keyboard digital setting

2 terminal UP/DOWN adjust setting frequency(stored after power off)

3 Serial port setting 4 VCI analog setting VCI-GND 5 CCI analog setting CCI-GND 6 YCI analog setting YCI-GND

7 terminal pulse PULSE frequency setting 8 combination setting

9 terminal UP/DOWN adjust setting frequency(not stored after power off)

1 0

F0.02 Run command channel selection

0 operation keyboard run control

1 terminal run command control(keypad STOP command ineffective )

2 terminal run command control(keypad STOP command effective )

3 serial port run command control ((keypad STOP command ineffective)

4 serial port run command control ((keypad STOP command effective)

1 0

F0.03 Run direction setting

Unit’s digit 0 forward run, 1 reverse run Tens place 0 reverse run allowed

1 reverse run banned

1 00

F0.08 Acce. time 1 0.1 6000.0 0.1 20.0

F0.09 Dece. time 1 0.1 6000.0 0.1 20.0

F0.10 Upper limit freq. Lower limit freq. 400.00Hz 0.01Hz 50.00Hz ×

F0.14 Torque boost 0.0 20.0(%) 0.1(%) 2.0(%)

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual

F1 Start-up, stop, brake function parameter group Function

code Name Set range Unit Factory

default Modificat

ion F1.05 Stop mode

0 Deceleration stop 1 free stop

2 Deceleration DC brake stop

1 0 ×

F1.06 DC brake initiative freq.

when stop running 0.0 15.00Hz 0.01Hz 0.00Hz

F1.07 DC brake time when stop

running 0.0 20.0s 0.1s 0.0s

F1.08 DC brake voltage when stop

running 0 15 1 0

F2 Auxiliary run function parameter group Function

code Name Set range Unit Factory

default Modific

ation

F2.00 Analog filter time constant 0.00 30.00s 0.01s 0.20s

F2.06 Jog run frequency 0.10 50.00Hz 0.01Hz 5.00Hz

F2.07 Jog acceleration time 0.1 60.0s 0.1s 20.0s

F2.08 Jog deceleration time 0.1 60.0s 0.1s 20.0s

F2.18 Acce.time2(Smoothly start-up

Acce.time) 0.1 6000.0 0.1 20.0

F2.19 Dece.time 2(Smoothly start-up

Dece.time) 0.1 6000.0 0.1 20.0

F2.21 Interval time 1 of retracting volume

diameter calculation 0~500ms 1ms 300ms

F2.22 Empty diameter gain(retracting and

releasing gain) 0.0~800.0% 0.1% 40.0

F2.23 PID adjustor gain 0.0~800.0% 0.0% 30.0

F2.24 Start-up volume diameter calculation gain selection

0 F2.25

1 F2.26 1 0

F2.25

Start-up volume diameter calculation gain( volume diameter calculation gain 4)

0.0~20.0% 0.1% 0.8

F2.26 Volume diameter calculation gain 3 0.0~20.0% 0.1% 0.4 F2.27 Volume diameter calculation gain 2 0.0~20.0% 0.1% 0.0 F2.28 Volume diameter calculation gain 1 0.0~20.0% 0.1% 0.0 F2.29 Upper limit of retracting volume gain 0.0~200.0% 0.1% 100.0 F2.30 Start-up retracting and releasing gain

control

0 calculation

1 with out change 1 1

F2.31 Retracting and releasing speed gain +/- control

0 0~F2.30

1 -F2.30~F2.30 1 0

F2.32 Retracting and releasing recombination control

0 externally input

1 interiorly input 1 0

F2.33 Interval time 0 of retracting volume

diameter calculation 0~500ms 1 800

F2.34 Dead zone of of retracting volume

diameter calculation 0.01~1.00V 0.01V 0.10

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual

F2.35 Range 1 of retracting volume diameter

calculation F2.34~F2.36 1 0.70

F2.36 Range 2 of retracting volume diameter F2.35~F2.37 0.01V 1.20 F2.37 Range 3 of retracting volume diameter F2.36~F2.38 1 1.70 F2.38 Range 4 of retracting volume diameter F2.37~5.00V 0.01V 2.20

F2.39 Smoothly start-up time 100~1500ms 1 2000

F2.40 Start-up PID gain control

0 K2=F2.39 1 T<F2.39 K2=0

T>F2.39 K2=T/F2.44*F2.39

1 1 F2.41 Smoothly start-up PID selection 0 PID

1 PD 1 1

F2.42 Volume diameter reset control 0 Stop with automatically reset

1 X6 terminal manual reset 1 0 F2.43 Wire disconnecting and delay PID

control

0 PID

1 PD 1 1

F2.44 Time of wire disconnecting delay 0~32000Vms 1 5000

F3 Closed-loop run function parameter group Function

code Name Set range Unit Factory

default Modificat

ion

F3.00

Closed-loop run control selection

0 closed-loop run control ineffective 1 PI closed-loop run control effective 2 reserved

3 Special for drawing machine VCI provision,

VCI ordinary PID closed-loop effective 4 Special for drawing machine VCI

provision VCI+PID closed-loop effective 5 Special for drawing machine VCI

provision, feed forward control VCI PID closed-loop effective

1 0 ×

F3.08 Proportion gain KP 0.000 9.999 0.001 0.250

F3.09 Integral gain KI 0.000 9.999 0.001 0.010

F3.12 Deviation margin 0.0 20.0(%) percentage relative to max.value

of closed-loop provision 0.1(%) 1.0(%)

F3.20 PID proportion gain2 0.000~9.999 0.001 0.300 ×

F3.21 PID integral gain 2 0.000~9.999 0.001 0.000

F3.22 ID Automatically parameter adjustment basis

0 Only use the first PID parameter 1 Automatic adjustment base on volume

diameter(that is to select from two group of PID parameters according to the place of tension bar )

1 1

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual

F3.30

Failure relay TA,TB,TC function selection

0 inverter running RUN 1 frequency arriving signal FAR 2 frequency level detecting signal FDT1 3 reserved

4 Over load warning alarm signal OL 5 Output frequency reach high limit

FHL

6 Output frequency reach low limit FLL 7 inverter under voltage blockage stop (LU) 8 external failure stop running EXT 9 inverter zero speed running 10 PLC running

11 simple PLC section running finished 12 PLC finish a cycle running 13 reserved

14 inverter ready to run (RDY) 15 inverter malfunction

16 Swing frequency high and low limit restriction

17 interior counter reach final value 18 interior counter reach specified value 19 set run time arriving

20 interior timing arriving 21 reserved

22 reserved 23 reserved 24 reserved

15

F5 Terminal correlative function parameter group Function

code Name Set range Unit Factory

default Modifica

tion

F5.00 Input terminal X1 function selection

31 Run command channel selection 3 32 Swing frequency jump-in 33 External interruption input 34: Interior counter reset end 35 Interior counter triggering end 36 Interior timer reset end 37 Interior timer triggering end 38 Pulse frequency input Only effective for

X7,X8 39 Reserved 40 Reserved 41 Reserved 42 Reserved

1 0 ×

F5.01 Input terminal X2 function

selection Same as above F5.02 Input terminal X3 function

selection Same as above

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual

F5.10

Open circuit electric collector output terminal OC1 output setting

0 inverter running RUN 1 frequency arriving signal FAR 2 frequency level detect signal FDT1 3 Reserved

4 Over load warning alarm signal OL 5 Output frequency reach high limit FHL 6 Output frequency reach low limit FLL 7 inverter under voltage blockage stop (LU) 8 external failure stop running EXT 9 inverter zero speed running 10 PLC running

11 simple PLC section running finished 12 PLC finish a cycle running 13 Reserved

14 inverter ready to run (RDY) 15 inverter malfunction

16 Swing frequency high and low limit restriction

17 interior counter reach final value 18 interior counter reach specified value 19 set run time arriving

20 interior timing arriving

21 OC1- the first pump of variable frequency OC2- the first pump of bypass frequency

OC3- the second pump of variable frequency

OC4- the second pump of bypass frequency

22 Reserved 23 Reserved 24 Reserved F5.15 FDT1(frequency level)

electric level 0.00 Upper limit frequency 0.01Hz 10.00Hz

F5.16 FDT1 lag 0.00 50.00Hz 0.01Hz 1.00Hz

F5.17

Analog output (AO1)selection 0 output frequency (0 high limit frequency) 1 set frequency (0 high limit frequency) 2 output current (0 2×rated current ) 3 output voltage (0 1.2×load motor rated

voltage)

4 Busbar voltage (0 800V) 5 PID provision (0.00 10.00V) 6 PID feedback (0.00 10.00V) 7 Reserved

8 Reserved 9 Reserved

1 0

F5.18 Analog (AO1)gain 0.50 2.00 0.01 1.00

F5.19 Analog output (AO1) offset 0.00 10.00V 0.01 0.00

F5.20 Analog output (AO2) selection Same as F5.17 1 0

F5.21 Analog output (AO2) gain 0.50 2.00 0.01 1.00

F5.22 Analog output (AO2) offset 0.00 10.00V 0.01 0.00

www.enc.net.cn/en Tel/Fax:86-755-26984485/26985120 Appendix 1 EDS1100 Drawing machine Inverter Manual

F7 Frequency provision function parameter group Function

code Name Set range Unit Factory

default Modifica

tion F7.03 VCI max.provision

corresponding frequency 0.00 high limit frequency 0.01 Hz 50.00Hz