Phạm Nguyễn Vinh, Nguyễn Tri Thức, Kiều Ngọc Dũng (2018), “Hiệu quả của máy tái đồng bộ tim trong điều trị suy tim

Một phần của tài liệu NGHIÊN CỨU TỐI ƯU HÓA KHOẢNG DẪN TRUYỀN NHĨ THẤT BẰNG SIÊU ÂM DOPPLER TIM VÀ THÔNG TIM Ở BỆNH NHÂN ĐƯỢC ĐẶT MÁY TÁI ĐỒNG BỘ TIM .LUẬN ÁN TIẾN SĨ Y HỌC (Trang 27 - 30)

(2018), “Hiệu quả của máy tái đồng bộ tim trong điều trị suy tim ở Bệnh Viện Chợ Rẫy”. Tạp Chí Y Học Tp Hồ Chí Minh, phụ bản

HUE UNIVERSITY

HUE UNIVERSITY OF MEDICINE AND PHARMACY

THUC NGUYEN TRI

RESEARCH ON OPTIMIZATION OF ATRIOVENTRICULAR INTERVAL USING DOPPLER ECHOCARDIOGRAM AND INTERVAL USING DOPPLER ECHOCARDIOGRAM AND

CATHETERIZATION IN PATIENTS WITH CARDIAC RESYNCHRONIZATION THERAPY DEVICE RESYNCHRONIZATION THERAPY DEVICE

MEDICAL DOCTORATE THESIS SPECIALITY: INTERNAL MEDICINE SPECIALITY: INTERNAL MEDICINE

Number: 9720107

THESIS INSTRUCTORS: PhD.MD LONG NGUYEN CUU PhD.MD LONG NGUYEN CUU

ASSOCIATED PROFESSOR PhD.MD TIEN HOANG ANH

The thesis is conducted at:

HUE UNIVERSITY OF MEDICINE AND PHARMACY THESIS INSTRUCTORS: THESIS INSTRUCTORS:

PROFESSOR.LONG NGUYEN CUU PROFESSOR.TIEN HOANG ANH PROFESSOR.TIEN HOANG ANH

Reviewer 1:

Reviewer 2:

Reviewer 3:

The thesis will be defended before the Hue University Doctoral Dissertation Evaluation Council

Meeting at: No. 3, Le Loi, Hue City, Thua Thien-Hue Province At: ... hour ... minute, date ... month ... year 2020.

The thesis can be found at: - National Library of Vietnam - Learning materials center Hue

THESIS INTRODUCTION 1. Rationale and necessity of the study 1. Rationale and necessity of the study

Heart failure is a complex clinical syndrome resulting from damage or dysfunction of the heart that causes the ventricles not to receive (diastolic heart failure) or eject blood (systolic heart). Many studies have shown that cardiac resynchronization (CRT) improves heart function, prognosis, and quality of life in heart failure patients with cardiac dyssynchrony. However, 30% of patients still do not respond to CRT, and heart failure conditions do not improve. The study also shows that the leading cause of patients not responding to CRT is the atrioventricular conduction interval not being optimized, accounting for 47%. Therefore, the atrioventricular conduction interval optimization is a simple but essential and widely applicable method to increase the CRT response rate.

At Cho Ray Hospital, CRT has been implemented since 2008. However, research on CRT and research on optimizing atrioventricular conduction interval in our country is still limited. Therefore, to contribute to an objective assessment of the correlation and accuracy of the methods to optimize atrioventricular conduction intervals in patients with CRT, thereby helping clinicians to select doppler echocardiogram as a method for optimization and maximizing the effectiveness of heart failure treatment, we conducted the research:

"Study on optimizing the atrioventricular conduction interval

with Doppler echocardiogram and cardiac catheterization in

patients with cardiac resynchronization therapy device."

Một phần của tài liệu NGHIÊN CỨU TỐI ƯU HÓA KHOẢNG DẪN TRUYỀN NHĨ THẤT BẰNG SIÊU ÂM DOPPLER TIM VÀ THÔNG TIM Ở BỆNH NHÂN ĐƯỢC ĐẶT MÁY TÁI ĐỒNG BỘ TIM .LUẬN ÁN TIẾN SĨ Y HỌC (Trang 27 - 30)

Tải bản đầy đủ (PDF)

(54 trang)