... concentrating solar power dish and trough systems, micro-hydropower, and biomass systems for electricity generation. Special attention is given to under- standing the physics of fuel cells and their potential ... in the electric power industry, worldwide. New tech- nologies on both sides of the meter leading to structural changes in the way that power is provided and used, an emerging demand for electricity ... Stein and Reynolds (1992). Average power w t in p a , p b or p c p a p b p c Power Total power p a + p b + p c is constant Figure 2.16 The sum of the three phases of power in balanced delta and...
Ngày tải lên: 24/03/2014, 13:20
Ngày tải lên: 03/01/2014, 19:36
System and load points reliability evaluation for electric power systems
Ngày tải lên: 03/01/2014, 19:39
direct methods for stability analysis of electric power systems theoretical foundation, bcu methodologies, and applications
... gura- tion of power networks. Load disturbances, on the other hand, are the sudden large load changes and the small random fl uctuations in load demands. The confi guration of power networks ... accurately modeling power system components such as synchronous generators, excitation systems, and loads has received a great deal of attention from the power industry. Standard generator and excitation ... between the excitation system and the rest of the power system, and (3) the degree of saturation and equipment aging, and so on. Also, the parameter values of excitation systems provided by manufacturers...
Ngày tải lên: 30/05/2014, 23:38
Tài liệu ELECTRIC POWER SYSTEMS A CONCEPTUAL INTRODUCTION pptx
... Multiple Generators: Real Power 107 4.3.4 Multiple Generators: Reactive Power 112 viii CONTENTS ELECTRIC POWER SYSTEMS including reactive power, I had seen. That manual proved to me that it ... the amount of power transmitted by a line is given by the product of the current flowing through it and 1.4 RESISTIVE HEATING 17 ELECTRIC POWER SYSTEMS A CONCEPTUAL INTRODUCTION Alexandra von Meier A ... complex subject of electric power. I envision two main audiences for this book. The first consists of students and researchers who are learning about electric circuits and power system engineering in...
Ngày tải lên: 18/02/2014, 22:20
Electric Power Systems docx
... expected to start and stop about 40 times a day as well as Figure 1.12 Wave power generation (Figure adapted from Pelamis) Introduction 19 Electric Power Systems Electric Power Systems B.M. ... system is operated and controlled to give secure and economic power supplies. c. Analysis, the calculation of voltage, power, and re active power in the system under normal and abnormal conditions. ... updated edition will ensure that Electric Power Systems continues to be an invaluable resource for senior undergraduates in electrical engineering. Electric Power Systems FIFTH EDITION B.M. WEEDY,...
Ngày tải lên: 07/03/2014, 10:20
Modern Optimization Techniques with Applications in Electric Power Systems pdf
... Soliman Department of Electrical Power and Machines Misr University for Science and Technology 6th of October City, Egypt Abdel-Aal Hassan Mantawy Department of Electrical Power and Machines Ain Shams ... rule-based systems with fuzzy logic, fuzzy logic controllers, and fuzzy decision systems. The broadest class of problems within power system planning and operation is decision making and optimization, ... Operation of Electric Power Systems. Academic, New York (1979) 2. Horst, R., Pardalos, P.M. (eds.): Handbook of Global Optimization. Kluwer, Netherlands (1995) 3. Kuo, B.C.: Automatic Control Systems, ...
Ngày tải lên: 30/03/2014, 07:20
Electric Machinery Fundamentals (Solutions Manual) Part 1 pdf
... necessary to supply 300 kW of 60-Hz power. The only power sources available operate at 50 Hz. It is decided to generate the power by means of a motor-generator set ... 50-Hz power to 60-Hz power? S OLUTION The speed of a synchronous machine is related to its frequency by the equation m n = 120 f e P To make a 50 Hz and ... has a synchronous reactance of 1.1 & and an armature resistance of 0.15 & . At 60 Hz, its friction and windage losses are 24 kW, and its core losses are 18 kW. The field circuit...
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 2 ppt
... now supplying power to the system, an increase in field current increases the reactive power supplied to the loads, and a decrease in field current decreases the reactive power supplied ... the output power will be given by P A V E sin = 3 ⎞ ™ X S and the output power is proportional to sin ™ . Since sin 11.4 °= 0.198 , and sin ... diagrams and by means of phasor diagrams what happens to the generator. How much reactive power does the generator supply now? (d) With the diesel generator now supplying real power...
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 3 docx
... of 0.75 & and an armature resistance of 0.04 & . Generators 1 and 2 have a characteristic power- frequency slope s P of 2.5 MW/Hz, and generators 2 and 3 have a ... direction of power flow reverses in Generator C. (c) The power sharing in (a) is not acceptable, because Generator 2 has exceeded its power limits. (d) To improve the power ... be adjusted to get them supplying a power factor of 0.85 lagging. At that point, each generator will be supplying its rated real and reactive power. (d) Under the conditions...
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 4 ppsx
... load current and power factor. If the field current and the magnitude of the load current are held constant, how will the terminal voltage change as the load power factor ... rated current and internal generated voltage of this generator? (b) What field current does this generator require to operate at the rated voltage, current, and power factor? ... know R A , X S , and the current angle ⎝ , we know enough to find the phase voltage ⎞ V , and therefore the terminal voltage T V . At lagging power factors, ⎞ V can ...
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 5 ppsx
... power and power factor to the bus. You may ignore the armature resistance R A when answering the following questions. (a) What would happen to the real and reactive power ... lagging, and 60 Hz. Its synchronous reactance is 0.9 & , and its resistance may be ignored. (a) What is its voltage regulation? (b) What would the voltage and apparent power ... voltage E A = 13,590 V, and the torque angle ™ = 23 ° . (c) Ignoring losses, the input power would equal the output power. Since ( )( ) and OUT P 0.85 ...
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 6 ppt
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 7 pdf
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 8 pps
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 9 ppt
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 10 ppt
Ngày tải lên: 06/08/2014, 11:20
Electric Machinery Fundamentals (Solutions Manual) Part 11 ppsx
Ngày tải lên: 06/08/2014, 11:20
TÌM HIỂU VỀ HỆ THỐNG ĐIỆN CỦA IEEE (Understanding Electric Power Systems)
Ngày tải lên: 23/08/2014, 10:23
Bạn có muốn tìm thêm với từ khóa: