low voltage wiring techniques

Tài liệu Low Voltage Wiring - Dây điện áp thấp docx

Tài liệu Low Voltage Wiring - Dây điện áp thấp docx

... Lockswitches 1.00 1.50 2.00 2.50 Low- voltage cable, 2/c (per 1000 ft) 8.50 12.00 14.00 16.00 Low- voltage cable, 3/c (per 1000 ft) 9.50 14.00 16.00 18.00 Low- voltage cable, 4/c (per 1000 ft) 10.50 ... start or grow a business, and how to work in other areas of the low- voltage systems industry It then covers installation methods, techniques, and requirements to comply with the 1999 National Electrical ... Review other low- voltage systems work year What businesses can we launch easily? ➣ Check out computers ➣ Check out photovoltaics Explore markets for consulting business to raise total cash flow by...

Ngày tải lên: 26/01/2014, 08:20

417 339 0
DUAL LOW VOLTAGE POWER AMPLIFIER

DUAL LOW VOLTAGE POWER AMPLIFIER

... unless otherwise specified) PARAMETER Operating Supply Voltage Quiescent Circuit Current SYMBOL TEST CONDITIONS VCC ICC VIN=0 Stereo Closed Loop Voltage Gain Bridge Channel Balance DIP-8 SOP-8 Output ... QW-R107-006.E TDA2822 LINEAR INTEGRATED CIRCUIT ABSOLUTE MAXIMUM RATINGS (Ta=25°C) PARAMETER Supply Voltage Output Peak Current SYMBOL VCC IO(peak) RATINGS UNIT 15 V A DIP-8 1.0 Power Dissipation ... www.unisonic.com.tw -1 0.4 0.28 VCC=3V,RL=4Ω, THD=10% DIP-8 SOP-8 DIP-8 SOP-8 Ripple Rejection Output Noise Voltage Cross Talk Input Resistance MIN 1.8 24 100 TYP 40 40 0.65 0.45 0.11 0.07 1.35 0.94 0.35...

Ngày tải lên: 12/09/2013, 10:00

5 291 0
Distribution in low-voltage installations

Distribution in low-voltage installations

... E - Distribution in low- voltage installations A distinction is made between: b Traditional distribution switchboards in ... Electrical installation guide 2010 EIG_chap_E-2010.indb 17 04/12/2009 11:52:13 E - Distribution in low- voltage installations b Type tests and routine tests They ensure compliance of each distribution ... Conductor marking Conductor identification must always respect the following three rules: b Rule The double colour green and yellow is strictly reserved for the PE and PEN protection conductors b...

Ngày tải lên: 28/10/2013, 03:15

10 653 1
Tài liệu Ecodial V3.38 Low-voltage electrical installation design software Fupact and variable speed drive ppt

Tài liệu Ecodial V3.38 Low-voltage electrical installation design software Fupact and variable speed drive ppt

... standard allows it v The maximum voltage drop authorised by the IEC60364 standard is for information only In Ecodial V3.38, the users are allowed to enter their own value However, if the voltage ... modifying the circuit-breaker settings The new curves are calculated and displayed immediately w -voltage electrical installations Step-by-step calculation Determine the source power Just enter ... devices, Isc max (1, or 3-phase), Isc (1 or 2-phase), earth fault current, R, X, trip unit settings b voltage drops, earth-fault protection Different simulations can be carried out at this stage to...

Ngày tải lên: 12/12/2013, 13:15

4 769 2
Tài liệu Building a Better Hospital with Low-Voltage Convergence pdf

Tài liệu Building a Better Hospital with Low-Voltage Convergence pdf

... was insufficient to accommodate the amount of low- voltage cabling or anticipated growth,” continues Byers “The smaller diameter of the TrueNet cable allowed us to run 96 cables through the fire-stopping ... Over million feet of TrueNet Category 5e provides over 20,000 connections to support all the low- voltage systems throughout the facility, including network and Internet access, VoIP telephones, ... strategy for the new Children’s Hospital was to have a single cabling infrastructure for all low voltage systems, including security, data, voice, nurse call, wireless, and monitoring systems...

Ngày tải lên: 21/12/2013, 07:17

4 340 0
iec 60269-1 low-voltage fuses - general requirements

iec 60269-1 low-voltage fuses - general requirements

... transient voltage exists (see 2.3.23.1) followed by a second one during which only the power frequency or d.c recovery voltage (see 2.3.23.2) exists 2.3.23.1 transient recovery voltage recovery voltage ... recovery voltage recovery voltage after the transient voltage phenomena have subsided NOTE - The power frequency or d.c recovery voltage may be referred to as a percentage of the rated voltage ... usually stated for low- voltage fuses are: voltage, current, breaking capacity, power dissipation and acceptance and frequency, where applicable In the case of a.C., rated voltage and rated current...

Ngày tải lên: 25/12/2013, 10:53

145 468 1
iec 60269-2 low-voltage fuses - supplementary requirements for fuses for use by authorized person

iec 60269-2 low-voltage fuses - supplementary requirements for fuses for use by authorized person

... amendment has been prepared by subcommittee 32B: Low- voltage fuses, of IEC technical committee 32: Fuses The text of this amendment is based on the following documents: FDIS Report on voting 32Bl384lFD ... amendment has been prepared by sub-committee 328: Low- voltage fuses, technical committee 32: Fuses o f IEC The text of this amendment is based on the following documents: I FDIC I Report on voting ... below Note -If fuses that are designed for use by authorized persons are intended to be used by unskilled persons they should also comply with the requirements of I E C Publication 269-3: Low- voltage...

Ngày tải lên: 25/12/2013, 10:53

30 315 3
iec 60269-4-1 low-voltage fuses - supplementary requirements for fuse-links for the protection of

iec 60269-4-1 low-voltage fuses - supplementary requirements for fuse-links for the protection of

... devices according to the following sections shall comply with all subclauses of • IEC 60269-1: Low- voltage fuses – Part 1: General requirements; and • IEC 60269-4: Low- voltage fuses – Part 4: Supplementary ... 60269-4-1 has been prepared by subcommittee 32B: Low- voltage fuses, of IEC technical committee 32: Fuses The text of this standard is based on the following documents: FDIS Report on voting 32B/387/FDIS ... Group at 303-397-2295 60269-4-1 © IEC:2002 –7– INTERNATIONAL ELECTROTECHNICAL COMMISSION _ LOW- VOLTAGE FUSES – Part 4-1: Supplementary requirements for fuse-links for the protection of semiconductor...

Ngày tải lên: 25/12/2013, 10:54

42 420 2
iec 60269-4 low-voltage fuses - supplementary requirements for fuse-links for the protection of s

iec 60269-4 low-voltage fuses - supplementary requirements for fuse-links for the protection of s

... Page 15 5.2 Rated voltage Replace the existing subclause by the following: For rated a.c voltages up to 690 V and d.c voltages up to 750 V, IEC 60269-1 applies; for higher voltages, the values ... operation in service 3.4 Voltage 3.4.1 Rated voltage For a.c., the rated voltage of a fuse-link is related to the applied voltage; it is based on the r.m.svalue of a sinusoidal a.c voltage It is further ... power-frequency recovery voltage For all cases other than the sinusoidal a.c voltage, it is necessary to know the applied voltage as a function of time For a unidirectional voltage, the important...

Ngày tải lên: 25/12/2013, 10:55

87 405 1
iec 60439-1 low-voltage switchgear and controlgear assemblies - type-tested and partially ty

iec 60439-1 low-voltage switchgear and controlgear assemblies - type-tested and partially ty

... typetested assemblies (PTTA) of low- voltage switchgear and controlgear IEC 60947-1:1988, Low- voltage switchgear and controlgear Part 1: General rules IEC 60947-4-1:1990, Low- voltage switchgear and controlgear ... 2.9.6 transient overvoltages the transient overvoltages in the sense of this standard are the following [2.5.54 of IEC 60947-1] 2.9.6.1 switching overvoltage a transient overvoltage at a given ... defined by the following electrical characteristics 4.1 Rated voltages An ASSEMBLY is defined by the following rated voltages of its various circuits 4.1.1 Rated operational voltage (of a circuit...

Ngày tải lên: 25/12/2013, 11:00

212 889 10
iec 60439-2 low-voltage switchgear and controlgear assemblies - particular requirements for busba

iec 60439-2 low-voltage switchgear and controlgear assemblies - particular requirements for busba

... following standards: IEC 60269 (all parts), Low- voltage fuses IEC 60332-3:1992, Tests on electric cables under fire conditions - Part Tests on bunched : wires or cables IEC 60439-1 1999 ,Low- voltage ... the highest rated insulation voltage of any parts of the system stated by the manufacturer NOTE A double insulation system between low- voltage circuits and extra -low- voltage communication circuits ... having passed the glow-wire test if - there is no visible flame and no sustained glowing; - flames and glowing of the specimen extinguish within 30 s after the removal of the glow wire There shall...

Ngày tải lên: 25/12/2013, 11:05

74 825 14
iec 60439-3 low-voltage switchgear and controlgear assemblies - particular requirements for iow-v

iec 60439-3 low-voltage switchgear and controlgear assemblies - particular requirements for iow-v

... barriers may be omitted if circuits at lower voltages are wired in cables insulated according to the phase-to-earth voltage of the main circuits Safety extra -low voltage circuit conductors shall be ... +A2:2001 INTERNATIONAL ELECTROTECHNICAL COMMISSION LOW- VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES Part 3: Particular requirements for low- voltage switchgear and controlgear assemblies intended ... corresponding clauses in IEC 60439-3 - First edition (1990): Low voltage switchgear and controlgear assemblies - Part 3: Particular requirements for low- voltage switchgear and controlgear assemblies intended...

Ngày tải lên: 25/12/2013, 11:06

49 488 4
iec 60439-4 low-voltage switchgear and controlgear assemblies - particular requirements for assem

iec 60439-4 low-voltage switchgear and controlgear assemblies - particular requirements for assem

... consist of an incoming unit and may include a low voltage/ extra -low voltage (LV/ELV) transformer unit and, possibly, one or more low voltage /low voltage (LV/LV) transformer units 9.4.2 Incoming ... following types: a) either with rated operational voltages not less than the nominal supply voltages and rated frequencies in accordance with the national regulations; b) or lower operational voltages ... Design and construction 7.1 Mechanical design 7.1.1 General Add the following paragraphs: ACS shall be type-tested low- voltage switchgear and controlgear assemblies (TTA) All the apparatus shall...

Ngày tải lên: 25/12/2013, 11:07

56 514 5
iec 60439-5 low-voltage switchgear and controlgear assemblies - particular requirements for assem

iec 60439-5 low-voltage switchgear and controlgear assemblies - particular requirements for assem

... cycle) IEC 60238:1991, Edison screw lampholders IEC 60269-1:1986, Low- voltage fuses - Part 7: General requirements IEC 60439-1:1992, Low- voltage switchgear and controlgear assemblies and partially ... Definitions The definitions of part apply with the following additions and modifications: 2.1 General 2.1.1.2 partially type-tested low- voltage switchgear and controlgear assembly (PTTA): Not ... such patent rights International Standard IEC 60439-5 has been prepared by subcommittee 17D: Low- voltage switchgear and controlgear assemblies, of IEC technical committee 17: Switchgear and controlgear...

Ngày tải lên: 25/12/2013, 11:08

56 785 6
Electrical Equipment (implementing the Low Voltage Directive) ppt

Electrical Equipment (implementing the Low Voltage Directive) ppt

... mailto:customer.services@tso.co.uk Low Voltage Directive - the law in brief BACKGROUND On 19 February 1973, the Council of Ministers adopted Council Directive 73/23/EEC (“the Low Voltage Directive”) on the ... The Regulations replace, with certain savings, the Low Voltage Electrical Equipment (Safety) Regulations 1989 which implemented the original Low Voltage Directive Electrical equipment which complies ... mailto:customer.services@tso.co.uk 22 Availability of the Text of the Low Voltage Directive and CE Marking Directive: The complete texts of the Low Voltage Directive (2006/95/EC) have been published in the...

Ngày tải lên: 17/03/2014, 14:20

41 235 0
IEC 60947 6 2 low voltage switchgear and controlgear   multiple function equipment   control and

IEC 60947 6 2 low voltage switchgear and controlgear multiple function equipment control and

... 2-10: Glowing/hot-wire based test methods – Glow-wire apparatus and common test procedure IEC 60695-2-11:2000, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-wire ... 60695-2-13:2000, Fire hazard testing – Part 2-13: Glowing/hot-wire based test methods – Glow-wire ignitability test method for materials IEC 60947-1:1999, Low- voltage switchgear and controlgear – Part ... 5.7.2 Characteristic values Shunt release, under voltage (under current) relay or release: – rated voltage (current); – rated frequency; – operating voltage (current) Over-current relay or release:...

Ngày tải lên: 04/04/2014, 12:00

216 541 5
Low Voltage Products User manual Masterpact NW08-63 IEC potx

Low Voltage Products User manual Masterpact NW08-63 IEC potx

... minimum voltage and minimum frequency protection in Trip mode and the control unit powered b closing order not executed by the XF closing release b MN undervoltage release supply voltage too low ... voltage and the supply circuit (0.7 - 1.1 Un) If the problem persists, replace the MX release b drop in voltage insufficient or residual voltage (> 0.35 Un) across the terminals of the undervoltage ... resistance, cooling capacity) lower the following characteristics E51264B Test altitude (m) dielectric resistance voltage (V) average insulation level (V) maximum utilisation voltage (V) average thermal...

Ngày tải lên: 05/07/2014, 01:20

54 376 0
w