w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Spec Sheet Solutions for OEM Lab Environments As part of their strategy for growth, carriers are working to deliver new video and data services as quickly as possible. This translates into more fibers to manage, integration issues and numerous other challenges that need to be addressed up front, not in the field. As Original Equipment Manufacturers (OEMs) develop the next generation network solutions to deliver services such as IPTV and WiMAX, it is crucial that testing protocols simulate actual environments as closely as possible. Network simulations such as these are necessary for several reasons: • The carrier end customer must be able to visualize the end-to- end network before it is built • It is often necessary to model and customize the network configuration to customer specifications • Interoperability testing must be addressed early in the process • Network migration must be demonstrated in a controlled setting For innovative connectivity solutions for the lab environment, look to ADC. ADC products are right on the mark because our customers are your customers. We work with them every day, and our solutions are located throughout their networks. Operational processes for thousands of craft personnel revolve around our market-leading connectivity and cable management products. The following pages detail ADC’s lab environment solutions that incorporate the robust functionality of our industry-standard products. The solutions allow you to perform nonintrusive testing and to simulate the interconnections between network equipment all the way from the central office through the outside plant to the end customer. In addition to the products found here, ADC offers a full range of products to support all your lab needs, including fiber cable raceways, fiber and copper patch panels and cable assemblies. Contact ADC to learn how we can help you develop, test and deliver outstanding solutions for your customer. 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 2 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Outside Plant Network Simulation Products OmniReach ™ FDH 3000 iFDH Rack Mount Solution ADC's NEW OmniReach FDH 3000 Cabinet is designed from the ground up to meet the needs of carriers. The FDH 3000 iFDH rack mount solution is flexible and modular, featuring standardized splitter modules and accessories. Description Catalog Number 72-fiber ribbon APC SC pigtails for spliced distribution, no splitters, 12-fiber ribbon APC SC pigtails feeder FD3-MK072J00XX0FXA 288-fiber ribbon APC SC pigtails for spliced distribution, no splitters, 12-fiber ribbon APC SC pigtails feeder FD3-MM288J00XX0FXA 432-fiber ribbon APC SC pigtails for spliced distribution, no splitters, 24-fiber ribbon APC SC pigtails feeder FD3-MN432J00XX0FXB O r d e r i n g I n f o r m a t i o n OmniReach ™ Rack Mount Plug and Play Chassis Provides a rack-mounted centralized point for various plug and play test applications within the lab environment. Description Catalog Number OmniReach rack mount plug and play chassis with front and rear cable management, splitters ordered separately FPS-MPPRACKMTKT O r d e r i n g I n f o r m a t i o n Features • High density plug and play splitter chassis • Features the same plug and play splitters used in outside plant distribution hubs. • 19/23" mounting • EIA or WECO • 24 splitters in 7" (4RU) rack height • Optional cable management available (3RU) • Allows splitter use with existing patch panels Features • Three sizes available: 72, 288, 432 • Scalable in counts of 72 • Uses standard FDH 3000 splitter • Mounts on rack or wall • Indoor rated • Lockable 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 3 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Outside Plant Network Simulation Products OmniReach ™ Mini Plug & Play Splitter Modules Catalog Number FPS-MPP 1 __ __ __ Output Connector Style N SC ultra polish J SC angled polish Splitter Type Loaded A 1x32 standard C 1x16 standard G 2x32 standard-power J 1x8 standard L Dual 1x8 standard M Dual 1x16 standard N 1x4 standard P 2x16 standard R Dual 2x16 standard U Dual 1x4 standard W 1x2 standard Input Connector Style N SC ultra polish J SC angled polish Features • Standardized splitter modules • Features bend-optimized fiber and ruggedized extreme temperature cabling rated for material handling in cold temperatures and superior loss performance at 1490 and 1550 wavelengths • Rated from -50° C to 140° F (60° C) • Splitter types supported: 1x32, 2x32, 1x16, dual 1x16, 1x8, dual 1x8, 1x4, dual 1x4, 1x2, dual 1x2 • Allows pass-through of up to two fibers per splitter set • Splitters are easy to insert and remove without affecting adjacent splitters • Reversible dust cap makes test and turn-up easy For optical specifications, please contact ADC Technical Assistance Center. 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 4 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Outside Plant Network Simulation Products OmniReach ™ Hardened Connector Test/Lab Cables ADC's OmniReach Hardened Connector Test/Lab Cables provide an easy, workable interface for lab and test environments. O r d e r i n g I n f o r m a t i o n Description Catalog Number Hardened connector to UPC SC, 10' FHD-HN1R-0010F Hardened connector to APC SC, 10' FHD-HJ1R-0010F Hardened connector to stub, 10' FHD-H01R-0010F Hardened connector to UPC SC, 40' FHD-HN1R-0040F Hardened connector to APC SC, 40' FHD-HJ1R-0040F OmniReach ™ Hardened Connector Test Kit A convenient case that provides everything you need to test and clean hardened circuits O r d e r i n g I n f o r m a t i o n Description Catalog Number Complete hardened connector test kit FHD-TKIT-1 Bag for hardened connector test kit FHD-TKIT-BAG Test cable, 10' 3.0mm, hardened connector to standard APC SC connector FHD-HJ1R-0010F Test cable, 10' 3.0mm, hardened connector to standard UPC SC connector FHD-HN1R-0010F Test cable, 10' 3.0mm hardened connector to stub FHD-H01R-0010F APC SC to APC SC jumper, 3 meters FPC-APSC-S-3M APC SC to UPC SC jumper, 3 meters FPC-SPSC/APSC-S-3M Hardened adapter – hardened to standard APC SC RC-ADP-SCA-SM Hardened drop cable/adapter cleaning kit; includes hardened connector cleaning cassette (1-150 uses) and fifty (50) hardened adapter cleaning sticks FHD-ACC-CLNKIT1 MST/Hardened Drop Cable User Manual ADCP-96-040 Features • Hardened connector is terminated on standard 3mm fiber singlemode cable • Designed for ease of handling in lab and test environments • Features the same design as the rugged optical connector for outside plant environments • Features quick-release optical connector 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 5 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Network Testing Products Fiber Spool Panel ADC’s Fiber Spool Panel allows you to simulate an external network accurately, neatly and efficiently. Featuring neatly organized spools and an integrated adapter packs on the front panel, this innovative product allows you to test for signal quality, system loss and margin. Description Catalog Number FMX-ALC-4SPLPNL: 6RU panel, accommodates 4 spools with 8 UPC SC adapters (other adapter styles available) FMX-ALC-4SPLPNL Test spool, singlemode, XXKM*, LC-LC SPAT-LSMF-XXKM Test spool, singlemode, XXKM*, SC-SC SPAT-CSMF-XXKM Test spool, singlemode, XXKM*, SC-LC SPAT-CLSMF-XXKM O r d e r i n g I n f o r m a t i o n *XX = Spool length Standard spool lengths up to 50Km Custom spools up to 100Km (double width). Contact ADC for details Examples: Test spool, SM, 50Km, LC-LC = SPAT-LSMF-50KM Test spool, SM, 40Km, LC-LC = SPAT-LSMF-40KM Features • 19"/23" mounting • 6 RU panel size • Features four spools per panel • Dividers between spools allow the inside fiber end to be routed out the pass-through and between the spools • One adapter plate per panel (8 adapters per plate). • Polycarbonate rear and front doors. • Mounting positions to 2", 5" and 7" recess • Long-distance fiber spool option also available 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 6 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Network Testing Products Fiber Optic Loopback ADC’s Fiber Optic Loopback is used for diagnostics and troubleshooting. This product simulates an optical signal with which the technician can test, measure, analyze, transmit and distribute. In loopback testing, a signal is sent from a piece of equipment through a loopback or cable and returned to the source, which simulates a complete network connection. With this information, functional tests and internal diagnostics can identify equipment issues prior to deployment in the field. Description Decibels Catalog Number Singlemode loopback SC UPC 5dB LBSC-SMUP-05dB 10dB LBSC-SMUP-10dB 15dB LBSC-SMUP-15dB 20dB LBSC-SMUP-20dB 25dB LBSC-SMUP-25dB LC UPC 5dB LBLC-SMUP-05dB 10dB LBLC-SMUP-10dB 15dB LBLC-SMUP-15dB 20dB LBLC-SMUP-20dB 25dB LBLC-SMUP-25dB Multimode loopback SC PC 50µm, 5dB LBSC-M5MM-05dB 50µm, 10dB LBSC-M5MM-10dB 50µm, 15dB LBSC-M5MM-15dB 50µm, 20dB LBSC-M5MM-20dB 50µm, 25dB LBSC-M5MM-25dB 50µm 10G @ 300m, 5dB LBSC-M5UM-05dB 50µm 10G @ 300m, 10dB LBSC-M5UM-10dB 50µm 10G @ 300m, 15dB LBSC-M5UM-15dB 50µm 10G @ 300m, 20dB LBSC-M5UM-20dB 50µm 10G @ 300m, 25dB LBSC-M5UM-25dB LC PC 50µm, 5dB LBLC-M5MM-05dB 50µm, 10dB LBLC-M5MM-10dB 50µm, 15dB LBLC-M5MM-15dB 50µm, 20dB LBLC-M5MM-20dB 50µm, 25dB LBLC-M5MM-25dB 50 Ultra, 5dB LBLC-M5UM-05dB 50 Ultra, 10dB LBLC-M5UM-10dB 50 Ultra, 15dB LBLC-M5UM-15dB 50 Ultra, 20dB LBLC-M5UM-20dB 50 Ultra, 25dB LBLC-M5UM-25dB O r d e r i n g I n f o r m a t i o n 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 7 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Network Testing Products Attenuators Fiber optic attenuators are optical devices that induce a calibrated fixed loss between two connectors, which dampens, or attenuates, the fiber optic signal. ADC’s full line of attenuators is manufactured to meet the demands of your network. ADC’s in-line attenuators are installed between an adapter and connector, and are fused, providing exceptional optical performance * Other attenuation values and connector styles are available upon request. Please contact ADC Technical Assistance Center. Description Catalog Number* LC ultra polish 05 dB FOA-INLC05 10 dB FOA-INLC010 15 dB FOA-INLC015 20 dB FOA-INLC020 SC ultra polish 05 dB FOA-INSC05 10 dB FOA-INSC10 15 dB FOA-INSC15 20 dB FOA-INSC20 SC angled polish 05 dB FOA-INASC05 10 dB FOA-INASC10 15 dB FOA-INASC15 20 dB FOA-INASC20 FC ultra polish 05 dB FOA-INFC05 10 dB FOA-INFC10 15 dB FOA-INFC15 20 dB FOA-INFC20 O r d e r i n g I n f o r m a t i o n In-Line FC Attenuator In-Line SC Attenuator Web Site: www.adc.com From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our Web site. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 104519AE 4/07 Original © 2007 ADC Telecommunications, Inc. All Rights Reserved Spec Sheet . deliver outstanding solutions for your customer. 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 2 w w. Long-distance fiber spool option also available 4 / 0 7 • 1 0 4 5 1 9 A E Solutions for OEM Lab Environments Solutions for OEM Lab Environments 6 w w w . a d c .