1. Trang chủ
  2. » Công Nghệ Thông Tin

Tài liệu ADC KRONE - Datasheet - Cat 5e - HIGHBAND - 8pr Module doc

2 348 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 2
Dung lượng 90,78 KB

Nội dung

TrueNet ® HighBand® voice and data cross connect modules ADC KRONE’s HighBand modules provide maximum headroom in transmission performance for LAN and WAN Ethernet traffic whether it be voice or data. Modules can be either patched or jumpered and used in a Patch-by-Exception structured cabling solution. HighBand utilises the silver plated, world renowned LSA-PLUS ® technolgy – trademark by ADC KRONE. This technology has become the industry standard in over 60 countries. The gas tight contacts ensure a reliable and long lasting connection. Features: · Category 5e component compliance. · Modules can be jumpered or patched (or both). · Allows user to test/monitor access to a hardwired circuit without disrupting the signal. · Integrates easily with all of ADC KRONE’s solutions. · Silver plated LLSA-PLUS ® contacts made from superior spring copper alloy. · Upper and lower shell mouldings made from high quality PBT plastic. Application and Benefits: · Offers superior high speed connections for voice and data in backbone cabling. · Ideal in a Patch-by-Exception solution where more than 100 cross connects are required (8 and 10 pair only). · Mountable on standard ADC KRONE Profil ® mounting frames, backmount frames and 19” backmount style frames. SPEC SHEET adckrone.com/au • 1800 801 298 • helpdesk.au@adckrone.com ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting your local ADC KRONE office. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer. 6266 7/05 © 2002, 2004 ADC Telecommunications, Inc. All Rights Reserved. www.adckrone.com/au AUSTRALIA 2 Hereford Street, Berkeley Vale NSW 2261 Mailing Address: PO Box 335, Wyong NSW 2259, Australia TECH SUPPORT 1800 801 298 helpdesk.au@adckrone.com www.adckrone.com/nz NEW ZEALAND 2 Nevis Street, Petone, Wellington Mailing Address: PO Box 38-177, Wellington Mail Centre 6008, New Zealand HighBand ® High speed voice and data cross connect modules Specifications MECHANICAL Wire range for solid and stranded copper conductors: 0.4mm to 0.65mm (26 to 22 AWG)* Wire insulation diameter range (PE,PVC): 0.7mm to 1.4mm Number of wire terminations: ≥200 Wire insertion force (0.5mm conductor dia): 6N Wire pull out force, radial (0.5mm conductor dia): ≥5N Wire pull out force, axial (0.5mm conductor dia): ≥35N Number of patching cycles: 750 for modules and 200 for patch plugs *A maximum of 2 equal diameter solid conductors only, of up to 0.5mm conductor diameter can be terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any conductors >0.5mm diameter have been terminated, reversal to smaller conductors is no longer possible. ELECTRICAL Transmission, performance and reliability: ANSI/EIA/TIA 568A Cat. 5 ISO/IEC 11801 Cat. 5 ACA Compliant UL Certified Cat. 5 Change of contact interface resistance after reliability testing to EIA568A and ISO/IEC 11801 per through connection. That is, 2 insulation displacement and 1 disconnection contact joints: Typically <5mΩ Voltage/current rating at 25°C ambient: 150 VAC at 2.5A max. Dielectric strength: ≥ 1.5kVAC Surge voltage strength (1.2/50 μsec wave shape): ≥ 2.5kV Surge current strength (8/20 μsec wave shape): ≥ 3kA for modules ≥ 0.5kA for patch plugs Insulation resistance: ≥500,000 MΩ at 500 VDC ENVIRONMENTAL AND SAFETY Safety Compliance: UL 1863 Flammability rating of plastic housing: UL 94 VO Environment for use: Indoors or in dry enclosure rated IP54 or greater Operating temperature range: -40°C to +80°C Maximum relative humidity: ≤93% non-condensing SPEC SHEET Description Part Number HighBand 8 Pair Disconnection Module (box 10) 6468 5 060-00 HighBand 10 Pair Disconnection Module (box 10) 6468 5 061-00 HighBand Compact 8 Pair Disconnection Module (box 10) 6468 5 061-08 Also available switching modules (not for Patch-by-Exception solutions) HighBand 16 Pair Switching Module (box 10) 6468 5 080-00 HighBand 20 Pair Switching Module (box 10) 6468 5 081-00 Ordering Information . switching modules (not for Patch-by-Exception solutions) HighBand 16 Pair Switching Module (box 10) 6468 5 08 0-0 0 HighBand 20 Pair Switching Module (box. 10) 6468 5 06 0-0 0 HighBand 10 Pair Disconnection Module (box 10) 6468 5 06 1-0 0 HighBand Compact 8 Pair Disconnection Module (box 10) 6468 5 06 1-0 8 Also available

Ngày đăng: 24/01/2014, 03:20

TỪ KHÓA LIÊN QUAN