Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 Guideline for Upgrading Projects incl IEC 61850 to DIGSI V6.xx or higher From DIGSI V6.00 onwards, the complete IEC 61850 engineering is done with the Siemens IEC 61850 System Configurator (similar to recent DIGSI versions) Due to the separation of the IEC 61850 engineering, additional steps must be executed with the previous DIGSI installation before starting with V6.xx or higher So if you want to upgrade existing projects including IEC 61850 (created with V5.00 or previous) to DIGSI V06.xx or higher, read the guideline carefully and follow the steps described in the following sections Note: You have to follow the described steps for each of your projects! This guideline applies only if you are using IEC 61850 in your project If not, the upgrade workflow has not changed and you only have to perform step as usual Short summary: Open the previous DIGSI version, for example V5.00, open the project you want to upgrade to V6.xx or higher, and export it in SCD format Close DIGSI Install DIGSI V6.xx or higher and import all required DDDs (used in the old DIGSI project plus new V6.xx or higher DDDs) Open the IEC 61850 System Configurator (automatically installed with DIGSI V6.xx or higher) and select to open a project Select the SCD file from step and confirm the dialog with Open In order to create a new IEC project, you now have to select a target path Close the IEC 61850 System Configurator Start DIGSI V6.xx or higher, open the old DIGSI project, and confirm to upgrade it When asked for a related IEC project, browse to the IEC project created in step and select the project SCD file Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 Detailed guideline: Step 1: Open your previous DIGSI version, for example V5.00, and open the project you want to upgrade to V6.xx or higher In this example, the project is called 110kVBerlin In the Project tree, right-click the Project name and select Export… Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 As data format, select SCD – Substation Configuration Description and enter a file name In the example, the file is called 110kVBerlin_V500.scd Confirm the dialog by clicking Export and close DIGSI afterwards Step 2: Install DIGSI V6.xx or higher and import all required DDDs (used in the old DIGSI project plus new V6.xx or higher DDDs) Step 3: Open the IEC 61850 System Configurator V5.01 It was automatically installed together with DIGSI Now, select to open a project Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 Step 4: Navigate to the SCD file exported in Step 1, select it, and confirm the dialog with Open When you are asked if you want to create a new IEC 61850 System Configurator project, confirm with Yes Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 In the upcoming dialog, select a path and project name for your new IEC 61850 System Configurator project rd Note: Siemens recommends saving everything (IEC project, DIGSI project, Party project) under one parent folder In the example, the project was called 110kVBerlinIECEngineering, and located under the common folder 110kVBerlin After the successful creation of the project and import of the old SCD file, you find your IEC 61850 devices under IEDs Close the IEC 61850 System Configurator now Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 Step 5: Start DIGSI V6.xx or higher and open the old DIGSI project you want to upgrade DIGSI recognizes that the project was created with a previous DIGSI version and asks if you want to upgrade now Click OK Note: DIGSI will not overwrite your old project but rename the new project automatically to e.g _V06.xx Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 Step 6: Now, you have to establish an assignment between the new DIGSI and IEC 61850 System Configurator projects Click OK Navigate to the IEC 61850 System Configurator project created in Step In the example, it was 110kVBerlinIECEngineering Confirm the assignment by clicking Save The data of the IEC 61850 System Configurator project is imported Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved  Upgrade Guideline for DIGSI V6.xx or higher 2015-12-07 Now, you can see the IEC 61850 station in the project tree To check the assignment to the IEC 61850 System Configurator project, right-click the station and select Properties from the context menu Your DIGSI project has been successfully upgraded to V6.xx or higher and is now ready to use Siemens Aktiengesellschaft Copyrights  Siemens AG  2015 All Rights Reserved 

Ngày đăng: 08/12/2021, 14:12

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN