1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

PNOZ XV1P PILZ SAFETY MODULE CONTROLER

9 7 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P ` Safety gates ` Light beam devices Unit features ` Positive-guided relay outputs: – safety contacts (N/O), instantaneous – safety contact (N/O), delay-on de-energisation ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Reset button – Light barriers ` LED indicator for: – Switch status channel 1/2 – Supply voltage ` Plug-in connection terminals (either spring-loaded terminal or screw terminal) ` See order reference for unit types Gertemerkmale Gertebild Safety relay for monitoring E-STOP pushbuttons and safety gates ][Bildunterschrift Approvals Safety features The relay meets the following safety requirements: ` The circuit is redundant with built-in self-monitoring ` The safety function remains effective in the case of a component failure ` The correct opening and closing of the safety function relays is tested automatically in each on-off cycle ` The unit has an electronic fuse ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil Sicherheitseigenschaften Zusatz - Sicherung DC_PNOZ PNOZ XV1P Unit description ‹ The max category the safety contacts can achieve in accordance with EN 954-1 and EN ISO 13849-1 is stated in the technical details The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with ` E-STOP pushbuttons Bestimmung/Gertebeschreibung_Kategorie_PNOZ ‹ Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ ‹ Zulassungen Block diagram il tb a h s k c lo B d A1 A2 = = S11 Input 13 23 37 S12 S32 S21 S22 Input Input K3 K1 K4 Power Start Start S14 S33 S34 K2 Pilz GmbH & Co KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 14 24 38 NSG-D-2-308-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P Function description and, with a monitored reset, in the reset circuit too, – shorts between contacts in the input circuit ` Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects – earth faults in the reset and input circuit, – short circuits in the input circuit and, with a monitored reset, in the reset circuit too ` Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected ` Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects – earth faults in the reset and input circuit, – short circuits in the input circuit ][Funktionen_einkanalig ][Funktionen_zweikanalig_ohne_quer ][Funktionen_zweikanalig_mit_quer_ber ` Automatic start: Unit is active once the input circuit has been closed ` Monitored reset: Unit is active once the input circuit is closed and once the reset circuit is closed after the waiting period has elapsed (see technical details) ` Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors ][Funktionen_autoStart ][Funktionen_berStart_Wartezeit ][Funktionen_Kontaktvervielfachung Timing diagram rm g a itd e Z POWER Reset/Start Input Output safe Output safe del t1 Key ` Power: Supply voltage ` Reset/Start: Reset circuit S11-S14, S33-S34 ` Input: Input circuits S11-S12, S12S32, S21-S22 ` Output safe: Safety contacts, instantaneous 13-14, 23-24 t2 t3 t1 t2 t3 t4 t1 t2 t3 t5 t4 t1 ` Output safe del: Safety contacts, delayed 37-38 ` c: Automatic reset ` d: Monitored reset ` t1: Switch-on delay ` t2: Delay-on de-energisation t2 t3 ` t3: Delay time ` t4: Waiting period ` t5: Recovery time Wiring Please note: ` Information given in the “Technical details” must be followed ` Outputs 37-38 are delay-on de-energisation safety contacts ` To prevent contact welding, a fuse should be connected before the output contacts (see technical details) ` Calculation of the max cable runs lmax in the input circuit: ][Verdrahtung_Si_verz Imax = ` Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads Rlmax Rl / km Rlmax = max overall cable resistance (see technical details) Rl /km = cable resistance/km ` Use copper wire that can withstand 60/75 °C Pilz GmbH & Co KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-308-2009-09 -2 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P Preparing for operation Betriebsbereitschaft herstellen ` Supply voltage Supply voltage AC DC A1 L+ A2 L- ` Input circuit Input circuit E-STOP without detection of shorts across contacts Single-channel Dual-channel S11 S21 S12 S22 S32 S1 E-STOP with detection of shorts across contacts S12 Safety gate without detection of shorts across contacts S11 S21 S12 S22 S32 S11 S21 S12 S22 S32 S1 S1 Safety gate with detection of shorts across contacts S11 S21 S22 S12 S12 S1 S2 S32 Light beam device with detection of shorts across contacts via ESPE 24 V DC S21 S22 Pilz GmbH & Co KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de S12 S32 NSG-D-2-308-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P ` Reset circuit Reset circuit E-STOP wiring, safety gate Safety gate (dual-channel) Automatic reset S11 S14 S1 S11 S14 Monitored reset S2 S3 S33 S34 ` Feedback circuit Feedback circuit Contacts from external contactors Automatic reset Monitored reset S11 S14 13 (23) 14 (24) K5 S33 K6 K5 L1 N K6 S34 13 (23) 14 (24) S3 K5 K6 K5 L1 N K6 ` Key S1/S2 S3 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed Pilz GmbH & Co KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-308-2009-09 -4 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P Terminal configuration u g b n m le K ` The safety relay should be installed in a control cabinet with a protection type of at least IP54 ` Use the notch on the rear of the unit to attach it to a DIN rail ` Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g retaining bracket or an end angle) Montage_PNOZ_X Montage Dimensions * with spring-loaded terminals Abmessungen 121 (4.76") Installation 94 (3.70") 22,5 (0.88") * 101 (3.98") Pilz GmbH & Co KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-308-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P Notice This data sheet is only intended for use during configuration For installation and operation, please refer to the operating instructions supplied with the unit Service life graph Nennbetriebstrom (A) Nominal operating current (A) Courant coupé (A) Corriente nominal de servicio (A) Corrente di esercizio nominale (A) Nominale bedrijfsstroom (A) v rk u a d s n b e L 10 D GB F E I NL ][WICHTIG_PDB_alt 0.1 DC1: 24 V DC13: 24 V AC15: 230 V AC1: 230 V 10 100 D Schaltspielzahl x 103 GB Cycles x 103 F Nombre de manœuvres x 103 1000 10000 E Número de ciclos x 103 I Numero dei cicli di commutazione x 103 NL Aantal schakelingen x 103 ][Technische Daten PNOZ verzögert Technical details Electrical data Supply voltage Supply voltage UB DC Voltage tolerance Power consumption at UB DC Residual ripple DC Voltage and current at Input circuit DC: 24.0 V Reset circuit DC: 24.0 V Feedback loop DC: 24.0 V Number of output contacts Safety contacts (S) instantaneous: Safety contacts (N/O), delayed: Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V Safety contacts: DC1 at 24 V Safety contacts, delayed: AC1 at 240 V Safety contacts, delayed: DC1 at 24 V Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V Safety contacts: DC13 at 24 V (6 cycles/min) Safety contacts, delayed: AC15 at 230 V Safety contacts, delayed: DC13 at 24 V (6 cycles/min) Contact material 24 V -15 %/+10 % 3.5 W 20 % 35.0 mA 35.0 mA 3.5 mA Imin: 0.01 A , Imax: 5.0 A Pmax: 1250 VA Imin: 0.01 A , Imax: 5.0 A Pmax: 125 W Imin: 0.01 A , Imax: 5.0 A Pmax: 1250 VA Imin: 0.01 A , Imax: 5.0 A Pmax: 125 W Imax: 1.5 A Imax: 2.0 A Imax: 2.0 A Imax: 4.0 A AgSnO2 + 0.2 àm Au Pilz GmbH & Co KG, Felix-Wankel-Straòe 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-308-2009-09 -6 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV1P Electrical data External contact fuse protection (IK = kA) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: Safety contacts, delayed: Blow-out fuse, slow Safety contacts: Safety contacts, delayed: Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: Safety contacts, delayed: Max overall cable resistance Rlmax input circuits, reset circuits single-channel at UB DC dual-channel without detect of shorts across contacts at UB DC dual-channel with detect of shorts across contacts at UB DC Safety-related characteristic data PL in accordance with EN ISO 13849-1 Safety contacts, instantaneous Safety contacts, delayed

Ngày đăng: 29/09/2021, 22:58

Xem thêm:

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN