1. Trang chủ
  2. » Công Nghệ Thông Tin

Tài liệu Central Office Copper Cable pdf

60 382 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Central Office Copper Cable 2nd Edition COPPER CONNECTIVITY SOLUTIONS 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable iii w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Introduction .1 DS1 VDSL-Grade Transport System Cable 100 Ω Category 5e 24 AWG FTP Riser Cable .2 100 Ω 26 AWG FTP Riser Cable 4 DS1/DS1C/DS2 Transport System Cable 100 Ω Category 3 22 AWG Dual Shield FTP Riser Cable (600C Equiv.) .6 100 Ω Category 3 24 AWG FTP Tight Twist Riser Cable (1161A Equiv.) .8 100 Ω Category 3 24 AWG FTP Riser Cable .10 100 Ω Category 3 24 AWG Dual Shield FTP Riser Cable (1116A Equiv.) .12 100 Ω 26 AWG Dual Shield FTP Riser Cable (1249C Equiv.) .14 High Performance Switchboard Cable 100 Ω Category 5 24 AWG UTP Riser Cable 16 100 Ω Category 3 24 AWG FTP Riser Cable .18 100 Ω Category 3 24 AWG UTP Riser Cable 20 Enhanced Performance Switchboard Cable 100 Ω Category 3 22 AWG UTP Riser Cable 22 100 Ω Category 3 24 AWG UTP Riser Cable 24 100 Ω 26 AWG UTP Riser Cable (800A Equiv.) .26 90° C Enhanced Performance Switchboard Cable 100 Ω Category 3 22 AWG UTP Riser Cable 28 100 Ω Category 3 24 AWG UTP Riser Cable (1006A Equiv.) 30 100 Ω 26 AWG UTP Riser Cable (1000A Equiv.) .32 Standard Switchboard Cable 100 Ω 24 AWG UTP Riser Cable .34 85 Ω 24 AWG Dual Shield FTP Riser Cable (1107B Equiv.) .36 85 Ω 24 AWG FTP Riser Cable .38 Backbone Cable 100 Ω Category 5 24 AWG UTP Riser Cable 40 Horizontal and Backbone Cable 100 Ω Category 3 24 AWG UTP Riser Cable 42 100 Ω Category 3 24 AWG UTP Plenum Cable 44 80 Ω Category 1 24 AWG FTP Riser Cable .46 100 Ω Category 1 24 AWG UTP Riser Cable 48 100 Ω Category 1 24 AWG UTP Plenum Cable 50 Table of Contents 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable 1 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Central Office Cable Introduction ADC’s central office cables deliver the data bandwidth to eliminate throughput bottlenecks or downtime and improve customer satisfaction. The increased throughput potential translates to increased customer satisfaction. ADC combines innovative design and application engineering to deliver a cabling solution that exceeds your network’s physical layer requirements. Features and Benefits • Exceptional 85- and 100-Ohm series cables for both analog and digital services • Ideally suited for DS1, DS2, xDSL and all broadband services • Innovative and flexible designs • Non-plenum or plenum-rated, low-heat release cables • Shielded or unshielded • Meets or exceeds UL requirements • Cables available that meet or exceed Telcordia ® requirements • Superior-quality recognized through inclusion on service provider and original equipment manufacturer approved vendor lists (AVLs) • Available direct from the manufacturer or through distribution and cable assembly houses • Competitive lead times and low minimum order quantities • Superior customer service and technical support • Offers improved crosstalk and attenuation performance to deliver the bandwidth required for digital voice, data and video • Consistent product quality - No missing insulation, no excess adhesion - Tangle-free, kink-free - Jacket and insulation concentricity and cable roundness - Small outside diameter and cross-sectional area in bundles and cable - Streamlined engineering, production, and quality processes - In-process manufacturing quality inspections • Meets or exceeds industry requirements and environmental regulations - Heavy-metal free (i.e. cadmium, lead, mercury, etc) - Compliant to Directive 2002/95/EC Restriction of the use of certain Hazardous Substances (RoHS) and other known environmental regulations • Provides exceptional design and enhanced electrical and mechanical performance • Adheres to strict industry tolerance standards and customer specifications for use throughout major service provider networks around the world 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable 2 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 DS1 VDSL-Grade Transport System Cable 100 Ω Category 5e 24 AWG FTP Riser Cable Specifications CONSTRUCTION CHARACTERISTICS Conductors: 24 AWG solid tinned copper .51 mm (.0200”) Insulation: Polyethylene Insulation diameter: 0.97 mm (.038”) nominal Pairing: 39.4 twists/m (12 twists/ft) minimum Color-coding: Standard telephony, solid colors Shielding: Aluminum/polyester foil, face in, 25% overlap Drain wire: 24 AWG solid tinned copper Rip cord: Applied under jacket Inner jacket: Lead-free, flame retardant PVC Outer jacket: Lead-free, flame retardant PVC ELECTRICAL CHARACTERISTICS Conductor DC resistance @ 20º C (68° F) (maximum): 9.38 Ω/100 m (28.6 Ω/1000 ft) Resistance unbalance (maximum): 5% Mutual capacitance @ 1 kHz: 6.6 nF/100 m (20.0 pF/ft) Capacitance unbalance pair to ground (maximum): 262 pF/100 m (800 pF/1000 ft) Characteristic impedance: 100 ± 15 Ω Temperature rating: 75º C (167º F) Voltage rating: 300 VDC This cable is designed for terminating outside plant networks to digital switching and transmission equipment at the service provider’s central office, outdoor cabinets and at the customer’s premises. This design offers true TIA Category 5e performance to support digital subscriber line (xDSL) technologies, particularly VDSL and VDSL2. The quality, performance, size and flexibility of this cable makes it an excellent choice for terminating broadband equipment for deployment of digital video, data and voice. Compliances • UL Subject 444/CSA C22.2 No. 214 • (UL)-C(UL) Type CMR/CMG • NEC 800 Type CMR 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable 3 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 DS1 VDSL-Grade Transport System Cable 100 Ω Category 5e 24 AWG FTP Riser Cable Description Number of Pairs Unit Makeup Outer Diameter mm (inches) Weight kg/km (lbs/1000') Catalog Number* Category 5e 24 AWG FTP riser cable Jacket color: YY* Packaging: reel 25 2 / 8 / 15 13.0 mm (.51") 123 kg (183 lbs) B5ETRA-2524YYXX * To designate jacket color, replace YY as follows: BL = Blue, GY = Gray, WT = White To designate reel length, replace XX as follows: 02 = 304 m (1000') 04 = 609 m (2000') 05 = 762 m (2500') 06 = 914 m (3000') 10 = 1524 m (5000') O r d e r i n g I n f o r m a t i o n Frequency (MHz) Attenuation (dB/100 m) Maximum Return Loss (dB) Minimum PSNEXT (dB) Minimum PSELFEXT (dB) Minimum 0.772 1.9 19.4 64.0 63.0 1 2.0 20.0 62.3 60.8 4 4.1 23.0 53.3 48.8 8 5.8 24.5 48.8 42.7 10 6.5 25.0 47.3 40.8 16 8.2 25.0 44.2 36.7 20 9.3 25.0 42.8 34.8 25 10.4 24.3 41.3 32.8 31.25 11.7 23.6 39.9 30.9 62.5 17.0 21.5 35.4 24.9 100 22.0 20.1 32.3 20.8 DS1 VDSL-Grade Transport System Cable 100 Ω Category 5e 24 AWG FTP Riser Cable 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable 4 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Specifications CONSTRUCTION CHARACTERISTICS Conductors: 26 AWG solid tinned copper .40 mm (.0159”) Insulation: Polyethylene Insulation diameter: 0.76 mm (.030”) nominal Pairing: 39.4 twists/m (12 twists/ft) minimum Color-coding: Standard telephony, solid colors Shielding: Aluminum/polyester foil, face in, 25% overlap Drain wire: 24 AWG solid tinned copper Rip cord: Applied under jacket Inner jacket: Lead-free, flame retardant PVC Outer jacket: Lead-free, flame retardant PVC ELECTRICAL CHARACTERISTICS Conductor DC resistance @ 20º C (68° F) (maximum): 15.12 Ω/100 m (46.1 Ω/1000 ft) Resistance unbalance (maximum): 5% Mutual capacitance @ 1 kHz: 6.6 nF/100 m (20.0 pF/ft) Capacitance unbalance pair to ground (maximum): 262 pF/100 m (800 pF/1000 ft) Characteristic impedance: 100 ± 15 Ω Temperature rating: 75º C (167º F) Voltage rating: 300 VDC This cable is designed for terminating outside plant networks to digital switching and transmission equipment at the service provider‘s central office, outdoor cabinets and at the customer‘s premises. This design offers exceptional electrical performance to support digital subscriber line (xDSL) technologies, particularly VDSL and VDSL2. The quality, performance, size and flexibility of this cable makes it an excellent choice for terminating broadband equipment for deployment of digital video, data and voice. Compliances • UL Subject 444/CSA C22.2 No. 214 • (UL)-C(UL) Type CMR/CMG • NEC 800 Type CMR DS1 VDSL-Grade Transport System Cable 100 Ω 26 AWG FTP Riser Cable 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable 5 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Description Number of Pairs Unit Makeup Outer Diameter mm (inches) Weight kg/km (lbs/1000') Catalog Number* 26 AWG FTP riser cable Jacket color: gray Packaging: reel 25 2 / 8 / 15 10.5 mm (.41") 156 kg (105 lbs) B5ETRF-2526GYXX * To designate reel length, replace XX as follows: 02 = 304 m (1000') 04 = 609 m (2000') 05 = 762 m (2500') 06 = 914 m (3000') 10 = 1524 m (5000') O r d e r i n g I n f o r m a t i o n Frequency (MHz) Attenuation (dB/100 m) Maximum Return Loss (dB) Minimum PSNEXT (dB) Minimum PSELFEXT (dB) Minimum PSFEXT (dB) Typical 0.772 2.3 19.4 64.0 63.0 67.0 1 2.7 20.0 62.3 60.8 65.4 4 5.3 23.0 53.3 48.8 55.8 8 7.6 24.5 48.8 42.7 51.8 10 8.4 25.0 47.3 40.8 50.6 16 10.6 25.0 44.2 36.7 48.6 20 11.6 25.0 42.8 34.8 47.8 25 12.8 24.3 41.3 32.8 47.2 31.25 13.9 23.6 39.9 30.9 46.3 62.5 19.1 21.5 35.4 24.9 45.3 100 24.2 20.1 32.3 20.8 45.0 DS1 VDSL-Grade Transport System Cable 100 Ω 26 AWG FTP Riser Cable 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable 6 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 DS1/DS1C/DS2 Transport System Cable 100 Ω Category 3 22 AWG Dual Shield FTP Riser Cable (600C Equiv.) Specifications CONSTRUCTION CHARACTERISTICS Conductors: 22 AWG solid tinned copper Insulation: Polyolefin with a lead-free PVC skin Insulation diameter: 1.2 mm (.049”) nominal (2 pair and up) Pairing: 8.2 twists/m (2.5 twist/ft) minimum Shielding: Dual aluminum/polyester Drain wire: 22 AWG solid tinned copper Color-coding: Standard telephony, bandmarked Rip cord: Non-hygroscopic and non-wicking Jacket: Lead-free, flame retardant PVC Jacket thickness: .76 mm (.030”) nominal ELECTRICAL CHARACTERISTICS Conductor DC resistance @ 20º C (68° F) (maximum): 5.90 Ω/100 m (18.0 Ω/1000 ft) Resistance unbalance (maximum): 5% Mutual capacitance @ 1 kHz: 6.6 nF/100 m (20.0 pF/ft) Capacitance unbalance pair to ground (maximum): 262 pF/100 m (800 pF/1000 ft) Characteristic impedance: 100 ± 15 Ω Temperature rating: 75º C (167º F) Voltage rating: 300 VDC This cable is commonly used as digital transmission cable for DS1/T1, DS1C and DS2 frequencies. This design offers true TIA Category 3 electrical performance to support applications in which T1 speeds and low-loss shielded cable is required. Dual aluminum/polyester foil provides superior shielding performance to reduce signal interference. Compliances • UL Subject 444/CSA C22.2 No. 214 • (UL)-C(UL) Type CMR/CMG • ICEA S-90-661 • Two to four-pair, TIA/EIA-568-B.2 Category 3 Horizontal Cable • Over four-pair, TIA/EIA-568-B.2 Category 3 Backbone Cable • TIA/EIA 464-B DSX-1 Pulse Wave Shape Compliance at 650 feet • Telcordia ® GR-499 DSX-1 Pulse Wave Shape Compliance at 650 feet • Telcordia Technical Audit Report AU-885 Compliance Testing to GR-137-CORE; DS1 Waveform Compliance Testing at 650 feet [...]... C (167º F) 300 VDC 8/07 • 104264AE Central Office Copper Cable 100 Ω 26 AWG Dual Shield FTP Riser Cable (1249C Equiv.) www.adc.com • +1-952-938-8080 • 1-800-366-3891 14 DS1/DS1C/DS2 Transport System Cable 100 Ω 26 AWG Dual Shield FTP Riser Cable (1249C Equiv.) SRL (dB) Minimum NEXT (dB) Minimum PSNEXT (dB) Minimum 0.772 2.3 12.0 58.0 58.0 1 Central Office Copper Cable Frequency (MHz) Attenuation (dB/100... 100 ± 15 Ω 60º C (140º F) 300 VDC 8/07 • 104264AE Central Office Copper Cable 100 Ω 26 AWG UTP Riser Cable (800A Equiv.) www.adc.com • +1-952-938-8080 • 1-800-366-3891 26 Enhanced Performance Switchboard Cable 100 Ω 26 AWG UTP Riser Cable (800A Equiv.) SRL (dB) Minimum NEXT (dB) Minimum PSNEXT (dB) Minimum 0.772 2.4 12.0 43.0 43.0 1 Central Office Copper Cable Frequency (MHz) Attenuation (dB/100 m) Maximum... 0.772 Central Office Copper Cable Frequency (MHz) Attenuation (dB/100 m) Maximum www.adc.com • +1-952-938-8080 • 1-800-366-3891 13 DS1/DS1C/DS2 Transport System Cable This cable is commonly used as digital transmission cable for DS1/T1, DS1C and DS2 frequencies in switching and transmission equipment The cable is designed for switching and transmission equipment cabling for telephone central offices,... DS1/DS1C/DS2 Transport System Cable 8/07 • 104264AE Central Office Copper Cable 100 Ω Category 3 24 AWG FTP Riser Cable This cable is commonly used as digital transmission cable for DS1/T1, DS1C and DS2 frequencies in switching and transmission equipment This design offers true TIA Category 3 electrical performance to support applications in which T1 speeds and low-loss shielded cable is required This product... pF/ft) 262 pF/100 m (800 pF/1000 ft) 100 ± 15 Ω 75º C (167º F) 300 VDC 8/07 • 104264AE Central Office Copper Cable 100 Ω Category 3 24 AWG FTP Tight Twist Riser Cable (1161A Equiv.) www.adc.com • +1-952-938-8080 • 1-800-366-3891  FTP DS1/DS1C/DS2 Transport System Cable 100 Ω Category 3 24 AWG FTP Tight Twist Riser Cable (1161A Equiv.) NEXT (dB) Typical PSNEXT (dB) Typical 1.9 12.0 58.0 58.0 1 2.2 12.0... binders around center pairs 100-Pair 25-Pr Unit 2 Unit 3 • 104264AE SRL (dB) Minimum 0.772 Central Office Copper Cable Frequency (MHz) Attenuation (dB/100 m) Typical Blue binders around center pairs +1-952-938-8080 • 1-800-366-3891 11 DS1/DS1C/DS2 Transport System Cable This cable is commonly used as digital transmission cable for DS1/T1, DS1C and DS2 frequencies in switching and transmission equipment This... 5% 6.6 nF/100 m (20.0 pF/ft) 262 pF/100 m (800 pF/1000 ft) 100 ± 15 Ω 75º C (167º F) 300 VDC 8/07 • 104264AE Central Office Copper Cable 100 Ω Category 5 24 AWG UTP Riser Cable www.adc.com • +1-952-938-8080 • 1-800-366-3891 16 High Performance Switchboard Cable 100 Ω Category 5 24 AWG UTP Riser Cable Return Loss (dB) Minimum NEXT (dB) Minimum PSNEXT (dB) Minimum 0.772 1.9 23.0 64.0 64.0 1 2.0 23.0 62.3... 5% 6.6 nF/100 m (20.0 pF/ft) 262 pF/100 m (800 pF/1000 ft) 100 ± 15 Ω 75º C (167º F) 300 VDC 8/07 • 104264AE Central Office Copper Cable 100 Ω Category 3 24 AWG FTP Riser Cable www.adc.com • +1-952-938-8080 • 1-800-366-3891 18 High Performance Switchboard Cable 100 Ω Category 3 24 AWG FTP Riser Cable SRL (dB) Minimum NEXT (dB) Minimum PSNEXT (dB) Minimum 0.772 1.9 12.0 43.0 43.0 1 2.2 12.0 41.3 41.3... FTP riser cable Jacket color: gray Packaging: reel * To designate reel length, replace XX as follows: 02 = 304 m (1000') 04 = 609 m (2000') 05 = 762 m (2500') 06 = 914 m (3000') Catalog Number* 10 = 1524 m (5000') 8/07 • 104264AE Central Office Copper Cable Frequency (MHz) Attenuation (dB/100 m) Typical www.adc.com • +1-952-938-8080 • 1-800-366-3891 19 High Performance Switchboard Cable This cable is... 5% 6.6 nF/100 m (20.0 pF/ft) 262 pF/100 m (800 pF/1000 ft) 100 ± 15 Ω 75º C (167º F) 300 VDC 8/07 • 104264AE Central Office Copper Cable 100 Ω Category 3 24 AWG UTP Riser Cable www.adc.com • +1-952-938-8080 • 1-800-366-3891 20 High Performance Switchboard Cable 100 Ω Category 3 24 AWG UTP Riser Cable SRL (dB) Minimum NEXT (dB) Minimum PSNEXT (dB) Minimum 0.772 1.9 12.0 43.0 43.0 1 2.2 12.0 41.3 41.3 . Central Office Copper Cable 2nd Edition COPPER CONNECTIVITY SOLUTIONS 8 / 0 7 • 1 0 4 2 6 4 A E Central Office Copper Cable iii w w w. 4 2 6 4 A E Central Office Copper Cable 1 w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Central Office Cable Introduction

Ngày đăng: 10/12/2013, 18:15

Xem thêm: Tài liệu Central Office Copper Cable pdf

TỪ KHÓA LIÊN QUAN

w