1. Trang chủ
  2. » Ngoại Ngữ

tài liệu phần mềm siêu âm

14 10 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 14
Dung lượng 1,57 MB

Nội dung

Acceleration for all 2D & 3D anatomical contrasts, 100% coverage on all anatomies. Body[r]

(1)

A li ti f f t i

Application of fast scanning

technique “compressed SENSE” on MR system Philips Ingenia 1.5T

Phan Anh Phuong; Nguyễn Công tiến; Nguyễn Văn Hòa; 

Lê Văn Tài; Trần Duy Hưng; Nguyễn Tuấn Dũng; Lê Xuân Thanh Radiology center in Bach Mai hospital

Advantages of MRI

• Powerful imaging modality for clinical • Noninvasive examination of the body • does not use ionizing radiation

• High soft‐tissue characterization with flexible image‐contrast  parameters

(2)

Disadvantages of MRI

• Has been relatively slow compared to other imaging modalities such  as CT

• Low speed, thus long examination times 

• Limit spatial resolution and volumetric coverage • sensitivity to respiratory motion

The goals in MRI

(3)

Compromises in MRI

The invention of fast MR Imaging strategies

• Fast Low Angle Shot (FLASH) • Fast Spin‐ Echo(FSE) Imaging • Echo‐Plana Imaging

• Since Late 1990s Parallel Imaging techniques were proposed

(4)

Parallel Imaging

MRI questions.com

(5)

0

20

 

times

JPEG VS RAW

1

0

The concept of compressed sensing, which was originally 

proposed in the early 2000s by Donoho and Candès

K - space transform in MRI

(6)

Only centre and periphery of K - Space

TF

TF

(7)

Compressed SENSE principle

The goal image Incoherent  subsampling

Wavelet transform Denoising by threshold

Compressed SENSE principle

Wavelet 

transform and 

denoised saparsity Incoherent

undersampling

Non‐liner iterative 

(8)

Philips Compressed SENSE

(2D, 3D, 4D, all anatomies, all MRI sequences)

= =

SENSE + Compressed Sensing

(2D, 3D, 4D, all anatomies) (3D, body area)

Conventional sequences VS compressed SENSE

43% 400 600 800 T2_TSE_SAG _0.8X0.8X4 mm_3.33S T1_TSE_SA G_0.8X0.8X 4mm_3.36S CS_T2_TSE_SAG _0.8X0.8X4mm _2.02S CS_T1SAG_T SE_0.8X0.8X 4mm_2.00S T2_AX_TSE_0.8X0 8X4mm_3.36S CS_T2_AX_TSE_0.8 X0.8X4mm_2.07S

10.45s 6.09s

200 400

(9)

CS_FLAIR_AX_FS_ 0.69x1.1_RE1.3_2.58S

CS_T2_TSE_AX_

0.6x0.75_1.42S_RE 1.5 TOF_CS SENSE_0.6x0.9_RE3_2.59S

7.39s 200 400 600 800 TIME NON_CS CS 32%

FLAIR AX_FS_0.69x1.1_3.50S T2_TSE_AX_0.6x0.75_2.31S TOF_SENSE_0.6x0.9_4.47S

11.08s

Application on Philips 1.5T Ingenia

(10)

Application on Philips 1.5T Ingenia

CS_T1 3D_TSE_FS Sag_1.1.1mm_3:18s(CS=5)

Application on Philips 1.5T Ingenia

(11)

` Increase resolution

T2_SAG_TSE_1x 1.35x4mm_59S

CS_T2_SAG_TSE_0.8x0.8X4mm_

59S_RE 1.6_FOV280mm

(12)

Up to 50% acceleration

Acceleration for all2D & 3D anatomical contrasts, 100% coverageon all anatomies

Body

Brain Spine MSK

Vascular

Cardiac Breast Whole body

compatible

• 2D and 3D sequences • Fat saturation

• Dark fluid • Dixon • T1, T2, PD

(13)

Drawback

• Cannot be used:

• EPI

• Multislice‐TSE with partial NSA is used( half scan) • Non‐Cartesian scans( multiVane )

• OMAR • spectroscopy

(14)

Compressed SENSE- conclusion

• Faster imaging, higher system throughput • Image quality improvement is possible • Applicable in all anatomical regions • Work with almost 2D, 3D sequences

• Easier for breath hold/ faster for dynamic imaging • New high end study become possible

• New high‐end study become possible

hinhanhykhoa.com

Ngày đăng: 03/03/2021, 17:07

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN

w