1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Pasolink V4 Training Manual For Vietnam CT-IN NEC International Training, Ltd. Japan NECITR

332 2,6K 10
Tài liệu đã được kiểm tra trùng lặp

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 332
Dung lượng 12,27 MB

Nội dung

Pasolink V4 Training Manual For Vietnam CT-IN NEC International Training, Ltd Japan NECITR VSK-JUL/03-01 VSK- JUL/03- Introduction To Pasolink Family NEC International Training, Ltd Japan Application for Cellular Network Cellular/UMTS Backbone BTS STM-0 / PDH Approach BTS STM-1 Ring BTS BTS BTS BTS BTS Ethernet Application LAN to LAN Bridge PASOLINK/PASOLINK+ LANSW Ethernet LANSW Ethernet Router Internet Ethernet Application IP Network with low cost router Router Router PASOLINK/PASOLINK+ e/w WAN INTFC e/w WAN INTFC E1/ STM-1 E1/ STM-1 Router Router PASOLINK/PASOLINK+w/o WAN INTFC w/o WAN INTFC ETHER ETHER Ethernet Application IP(Private) and E1(Public) mixed Network Router PASOLINK w/o WAN INTFC Router w/o WAN INTFC ETHER ETHER E1 MUX PDH MUX Network MUX MUX E1 MUX PDH MUX Network MUX MUX Pasolink Family Pasolink Family (Front View) Pasolink V3 TRAFFIC OUT TRAFFIC IN IF IN/OUT CH1 ERR MON EOW RESET CALL CH1 CH2 CH3 CH4 ALM AUX ALM OW/DSC/ASC NMS/RA additional 9.6k with optional DSC card Voice Channels with optional ASC card 64k with optional Data card FUSE (1.5A) LA PORT OFF LAN INTF with optional PMC Pasolink V4 EOW IF IN/OUT RESET CALL PORT1 PORT2 WS/LAN ALM/AUX ALM PWR MAINT ODU IDU NMS/LAN FUSE (1.5A) RS232 TRAFFIC IN/OUT IDU LINE IN Option TRAFFIC IN/OUT MAINT ODU CH2 CH3 CH4 RS232 TRAFFIC IN/OUT 120 Ω PWR OW/DSC/ASC NMS/RA LINE IN LA PORT OFF additional 9.6k with optionalDSC card Voice Channels with optional ASC card 64k with optional Data card Cluster Alarms with optional card Option IF IN/OUT Option SC IN/OUT PNMT LCT EWO1 EOW2 LAN DSC/WS LAN CH1 CH2 CH3 NE2 ALM EOW RESET CALL PWR MAINT ODU IDU CH4 CH1 - CH8 IN/OUT NE1 Pasolink+ PDH x 64k CHs Option CH9 - CH16 WS IN/OUT V11 LAN PNMS ALM/AUX FUSE (1.5A) LINE IN OFF 2MB WS Option Note : Options are shown in red Pasolink Family Pasolink ODU Comparison Filtering Function T1 T2 T3 NECITR-YTC ART-SEP/02 V01 T4 T1 A T2 B T3 C T4 D E F G H Start T1 through T2 and Start T1 through T2 and Start T1 and End T3 End T3 through T4 End T3 through T4 Start T1 through T2 End T3 through T4 Start T1 End T3 Start T1 A A A A A A A B B B B B B B C C C C C C C D D D D D D D E E E E E E E F F F F F F F G G G G G G G H H H H H H H ON OFF Pasolink Network Management System 37 NETWORK CONFIGURATION NECITR-YTC ART-SEP/02 V01 IN THE NMS THE NETWORK IS FIRST DESIGNED AND CONFIGURED IN THE NETWORK CONFIG TOOL THIS CONFIGURATION FILE SHOULD BE LOADED TO THE PNMS FOR THE PNMS TO POLL AND MONITOR THE NETWORK WHEN NEW NE IS ADDED OR MODIFICATION TO THE EXISTING NETWORK IS CARRIED OUT A NEW CONFIGURATION FILE IS CREATED IN THIS CASE THE PNMS CONFIGURATION FILE SHOULD BE UPDATED TO REFLECT THE CHANGES MADE TO THE NETWORK CLICK THE NETWORK CONFIGURATION MENU IN THE PNMS MENU BAR SELECT EDIT FROM THE DROP DOWN MENU TO OPEN THE NETWORK CONFIG TOOL USE THIS TOOL TO CONFIGURE THE NETWORK (FOR DETAILS SEE THE NETWORK CONFIG TOOL MANUAL) CLICK THE NETWORK CONFIGURATION MENU IN THE PNMS MENU BAR SELECT UPDATE FROM THE DROP DOWN MENU TO OPEN THE UPDATE NETWORK CONFIGURATION WIZARD UPDATE NETWORK CONFIGURATION WIZARD IS USED TO UPDATE THE CONFIGURATION IN THE PNMS WHEN CHANGES TO THE NETWORK IS MADE IN THE NETWORK CONFIG TOOL Pasolink Network Management System 38 PNMS ERROR MESSAGES ERROR MESSAGE CAUSE NECITR-YTC ART-SEP/02 V01 TROUBLE SHOOTING DIALUP ENTRY [%S] NOT FOUND THE CONFIGURED DIALUP USED BY PNMS DOES NOT EXIST IN WINDOWS BT MAKE SURE THAT YOU HAVE CREATED THE DIALUP ENTRY IN THE WINDOWS ENVIRONMENT SOME *.DLL FILES ARE CORRUPTED OR MISSING CLOSING PNMS SOME *.DLL FILES USED BY THE PNMS ARE CORRUPTED OR CANNOT BE LOCATED RE-INSTALL THE PNMS SOFTWARE OR REPAIR THE CURRENT PNMS FAILED TO INITIALIZE PNMS THE PNMS ENCOUNTERED SOME FAILURE DURING STARTUP RESTART THE PNMS APPLICATION IF THE ERROR STILL EXISTS, RE-INSTALL OR REPAIR THE PNMS SOFTWARE LOGIN FAILURE, PLEASE CHECK USERNAME AND PASSWORD AND TRY AGAIN WRONG USER NAME OR PASSWORD ENTERED DURING LOGIN CHECK THE USER NAME AND PASSWORD AND TRY LOGIN AGAIN THE NEW AND CONFIRMED PASSWORDS DO NOT MATCH PLEASE TRY AGAIN THE NEW PASSWORD DOES NOT MATCH THE CONFIRMED PASSWORD THIS ERROR OCCURS WHEN CHANGING THE CURRENT PASSWORD CHECK THAT THE PASSWORDS ENTERED ON THE TWO FIELDS ARE THE SAME THE OLD PASSWORD DOES NOT MATCH WITH THE CURRENT PASSWORD, PLEASE TRY AGAIN WHEN CHANGING PASSWORD THE USER IS REQUIRED TO ENTER THE CURRENT PASSWORD USED IN THE OLD PASSWORD FIELD THIS ERROR APPEARS IF THE PASSWORD SUPPLIED IS INCORRECT MAKE SURE THAT THE PASSWORD ENTERED IN THE OLD PASSWORD FIELD MATCHED THE CURRENT PASSWORD STORE MAX IS OUT OF RANGE PLEASE USE NUMERIC VALUE FROM TO 90 THE NUMERIC VALUE ENTERED FOR STORE MAX IS OUT OF RANGE STORE MAX CAN HAVE A NUMERICAL VALUE FROM TO 90 MAKE SURE THE VALUE ENTERED IS WITHIN THIS RANGE NO “NAME” ENTERED PLEASE ENTER GROUP NAME THE ADDED GROUP DOES NOT HAVE A VALID NAME ENTER A VALID NAME FOR THE GROUP ILLEGAL CHARACTER USED “,” AN ILLEGAL CHARACTER WAS USED IN THE FIELD DO NOT USE SPECIAL CHARACTERS WIDTH IS OUT OF RANGE PLEASE USE NUMERIC VALUE FROM 100 TO 9999 THE NUMERIC VALUE ENTERED FOR WIDTH IS OUT OF RANGE WIDTH CAN HAVE A NUMERICAL VALUE FROM 100 TO 9999 MAKE SURE THE VALUE ENTERED IS WITHIN THIS RANGE LINE WIDTH IS OUT OF RANGE PLEASE USE NUMERIC VALUE FROM TO 20 THE NUMERIC VALUE ENTERED FOR LINE WIDTH IS OUT OF RANGE LINE WIDTH CAN HAVE A NUMERICAL VALUE FROM TO 20 MAKE SURE THE VALUE ENTERED IS WITHIN THIS RANGE FILE NOT FOUND THE FILE THAT WAS BEING UPLOADED WAS NOT FOUND IN THE PMC OR IN THE PNMS PC MAKE SURE THAT THE FILE BEING DOWNLOADED OR UPLOADED EXISTS OR IS NOT CORRUPTED DIALUP NAME IS INCORRECT THE DIALUP SUPPLIED TO THE PNMS DOES NOT EXIST OR IS INCORRECT MAKE SURE THAT THE DIALUP ENTRY SPECIFIED IS IN THE WINDOWS ENVIRONMENT DIALUP NAME ‘%S’ IS ALREADY IN USE PLEASE ENTER A NEW DIALUP NAME THE DIALUP SPECIFIED TO BE USED BY THE NEW GROUP IS ALREADY USED BY ANOTHER GROUP USE ANOTHER DIAL UP ENTRY ONE DIALUP ENTRY IS REQUIRED FOR EACH CPMC FILE ERROR : UNABLE TO READ FROM FILE UNABLE TO READ THE FILE BEING DOWNLOADED OR UPLOADED MAKE SURE THAT THE FILE BEING DOWNLOADED OR UPLOADED EXIST OR IS NOT CORRUPTED Pasolink Network Management System 39 Additional Training Materials NEC International Training, Ltd Japan ATPC Operation -65dBm +18dBm Transducer Transducer 43dB Variable Attenuator ODU ODU Attenuator (20dB) Attenuator (20dB) IDU IDU RX Threshold = -55dBm RX Level -50dBm +18dBm -5dBm ATPC Operation Stops ATPC Operation Starts TX Level ATPC Operation Stops -65dBm ATPC Operation Starts -55dBm 172 18 0 255 255 Sub Net Mask 255 255 255 192 Network Address Sub Net Add 10 Bits 18 1 1 0 0 0 0 0 0 0 0 0 0 0 First Host 171.18.0.1 1 1 0 0 0 0 0 0 0 0 1 1 0 Last Host 172.18.0.62 172 2nd Sub Net Default Sub Net Mask 172 1st Sub Net Network Address 18 65 First Host 171.18.0.65 1 1 0 0 0 0 0 0 0 0 1 1 1 Host 1 1 0 0 0 0 0 0 0 0 0 0 Last Host 172.18.0.126 Bits 3rd Sub Net 172 18 129 255 254 Network Address Bits 10 Bits Finally the available number of Subnets are 23 = First Host 171.18.0.129 Last Host 172.18.0.190 Host Bits 172 Available number of Hosts are 26 -2 = 62 4th Sub Net 255 1 1 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 1 1 1 Sub Net Address 18 193 1 1 0 0 0 0 0 0 0 1 0 0 First Host 171.18.0.193 1 1 0 0 0 0 0 0 0 1 1 1 Last Host 172.18.0.254 172.18.0.1 172.18.0.16 1st Sub Net 172.18.10.7 172.18.0.65 172.18.0.30 172.18.0.74 2nd Sub Net 172.18.0.129 3rd Sub Net 172.18.0.193 4th Sub Net 14 Subnetting 15 Subnetting 16 Mixed Configuration File Download pp_mib pp_Network Pasolink + Network System Pasolink (V3) pp_mib pp_Network Pasolink + Network Ppp System Paso-S 22 Connection Using Router (Pasolink) STATIC ROUTING TABLE 192.18.10.252 MAIN 192.18.1.9 PNMS 192.18.10.250 Pasolink V3 ERR MON TRAFFIC OUT TRAFFIC IN IF IN/OUT EOW RESET CALL CH1 CH2 CH3 CH1 CH4 CH2 CH3 ALM AUX ALM OW/DSC/ASC NMS/RA 192.18.1.10 Port IP Assignment 25 ODU FUSE (1.5A) RS232 TRAFFIC IN/OUT 120Ω MAINT PWR IDU CH4 LA PORT LINE IN OFF Performance / Events Data Management Event Log File Page n Page Page Day #1 PNMS Day #90 (300 Events) Events Status Change Alarm Occurrence Alarm Recovery Controls Parameter Change Link Performance ES SES UAS BBE OFS IDU (PM Card) Day #7 Page Day #1 Create One Event File per day, if the number of events per day is more than 300, will open another page under the same file Latest Event Log File If the link between IDU and the PNMS is broken the events occoured during the down time will not be available in the PNMS Day 20020911 Oldest 300 Day #1 Day 20020911 Day #90 Event Log File Event Log File Performance History is saved in the IDU daily (maximum of days) PNMS retreive this performance data at a preset time once per day Day 20020911 29 PM Card Performance Data Check using PNMT 30 USER PREVILAGES FOR PASOLINK PLUS SYSTEM Category ITEM Monitor SYSTEM ALARM BUZZER User Local Remote Admin O O O O O O CONNECT(Remote Login) PROVISIONING MTPC MTPC TX POWER O O O RX THRESHOLD LEVEL O O O ADDITIONAL ATT O O O ATPC MAXIMUM O O O ATPC MINIMUM O O O RX THRESHOLD LEVEL O O O ADDITIONAL ATT O O O TX POWER CONTROL on ALM ODU CPU ALM MODE O O O BER ALM HIGH BER(RADIO) THRESHOLD O O O THRESHLD(RADIO) RX SWITCH(RADIO) THRESHOLD O O O BER ALM E-BER(DMR) THRESHOLD O O O THRESHLD(DMR) SD(DMR) THRESHOLD O O O BER ALM E-BER(MUX) THRESHOLD O O O THRESHLD(MUX) SD(MUX) THRESHOLD O O O MAIN INTFC MAIN OUTPUT CONTROL O O O ALS O O O ALS DELAY TIME O O O SUB BASEBAND SUB INTFC O O O INTERFACE WS INTFC O O O WS LINE LENGTH O O O ASSIGNMENT O O O CHANNEL USAGE O O O ATPC OH ASSIGNMENT 31 V11-? DIRECTIONAL SETTING O O O O O O TX/RX FREQUENCY O O O TX SWITCH O O O TX MUTE O O O IF LOOPBACK O O O MAIN SIGNAL LOOPBACK-1 O O O MAIN SIGNAL LOOPBACK-2 O O O CW O O O ALS RESTART O O O ATPC MANUAL CONTROL O O O RX SWITCH O O O EQUIPMENT SETUP O O O NE NAME O O O MAINT MAINTENANCE EQUIPMENT SETUP O NOTE O O O O O O O O O O O O PMON Threshold O O O O Save to disk CTRL O RELAY CONFIGURATION O O O O Save to disk EVENT LOG O OUTPUT PMON O INPUT AUX I/O O O O O O O O O CONTROL DATE/TIME DOWNLOAD CONFIGURATION FILE O PROGRAM FILE O UPLOAD CONFIGURATION FILE O CPU RESET RESET O 32 O O PNMS #1 Hub 33 ... Measured Data 10 -11 10 -12 10 15 20 25 30 D/U (dB) 14 Pasolink V4 Training Manual NEC International Training, Ltd Japan PASOLINK (1+0) SYSTEMS NECITR-YTC ART-JUL/03-01 •2MB x 4, Fixed Bit Rate system...NECITR VSK-JUL/03-01 VSK- JUL/03- Introduction To Pasolink Family NEC International Training, Ltd Japan Application for Cellular Network Cellular/UMTS Backbone... Switch Modem - ODU-1 ODU-2 Switch ODU-2 Pasolink V4 Modem - Modem - V4 OUT DOOR UNIT Pasolink V4 NECITR-YTC ART-JUL/03-01 V4 OUT DOOR UNIT (7-38 GHz) NECITR-YTC ART-JUL/03-01 Low Freq RF IN/OUT

Ngày đăng: 28/10/2013, 03:15

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN