Issue1 - Draft 01/07/04 Form: E104 1of 2 SUBJECT TO CHANGE 23 ® D ESCRIPTION : H IGHBAND 25 C ATEGORY 6 M ODULE P ART #: 6468 2 600-00 P RODUCT D ESCRIPTION AND A PPLICATION The HIGHBAND 25 RANGE of modules provides a 24 pair high-density, high performance, cost competitive Category 6 data grade module, (the 25 th pair is not used) and a high-density cost competitive 25 pair Category 3 voice grade module to accept UTP & STP copper cables. It will supplement the existing HIGHBAND™ Range of modules. The upper and lower shell are moulded in PBT. The Category 6 shield is manufactured from tin plated mild steel. The module is designed for mounting on a backmount frame. Modules are terminated with the standard KRONE termination tools 6089 2 003-00 or 6417 2 055-01. Module may also be terminated with a 110 tool. A range of accessories is available for mounting, patching, labelling, numbering and disconnecting. T ECHNICAL S PECIFICATIONS Environment for use: Indoors or in dry enclosure rated IP54 or greater. Operating temperature range: -40°C to +80°C Maximum relative humidity: ≤ 93% non-condensing Wire range for solid & stranded copper conductors: 0.4-0.65 (26-22 AWG)* * A maximum of 2 equal, solid conductors only, of up to 0.5 conductor diameter can be terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any conductors >0.5 have been terminated, reversal to smaller conductors in no longer possible. Wire insulation diameter range (PE, PVC): Typically 0.7-1.4 Number of wire reterminations: Up to 200 Wire insertion force (0.5 conductor diameter): 6N Wire pull out force, radial (0.5 conductor diameter): 5N Wire pull out force, axial (0.5 conductor diameter): 35N Number of patching cycles, Modules: Up to 750 Patch plugs: Up to 200 Transmission & reliability: CAT 6 module: Meet & exceed Category 6 std. (ISO 11801 & TIA/EIA 568-B.2-1) CAT 3 module: Meet & exceed Category 3 std. (ISO 11801 & TIA/EIA 568-B.2) Change of contact interface resistance after reliability testing < 5mΩ Typical to ISO/IEC 11801 and TIA/EIA 568B per through connection. ie. 2 insulation displacement and 1 disconnection contact joint: Voltage/current rating at 25°C ambient: ≤ 150V AC at 2.5A max. Dielectric strength: ≥ 1.5kV AC Surge voltage strength (1.2/50 µsec wave shape): ≥ 2.5kV Surge current strength (8/20 µsec wave shape) Modules: ≥ 3kA Patch plugs: ≥ 0.5kA Insulation resistance: ≥ 50,000 MΩ at 500 VDC DC Resistance (CAT3) ≤ 0.3Ω to ASTM D4566 @20°C±3 Safety: UL 1863 Flammability rating of plastic housing: UL 94 V0 Issue1 - Draft 01/07/04 Form: E104 2of 2 SUBJECT TO CHANGE 23 ® G ENERAL D IMENSIONS A CCESSORIES  PATCH CORD 4 PAIR – RJ45 6451 2 700-XX  PATCH CORD 4 PAIR – 4 PAIR .6451 2 701-XX  PATCH CORD 1 PAIR 6451 2 702-XX  LABEL HOLDER 6462 2 408-00 O THER R ELATED P RODUCTS  HIGHBAND 25 CATEGORY 3 MODULE 6468 2 300-00  BMF KIT 300 PAIR 6450 1 101-00  BMF KIT 900 PAIR 6450 1 102-00  CABLE MANAGEMENT KIT 300 PAIR 6450 1 103-00  CABLE MANAGEMENT KIT 900 PAIR 6450 1 104-00  BACK MOUNT FRAME 12 WAY T=83 6450 2 155-00  CABLE MANAGEMENT KIT 300 PAIR 6450 1 103-00  CABLE RING SINGLE .6450 1 156-01  CABLE RING DUAL .6450 1 156-02  CABLE TROUGH .6450 2 157-00  COVER SINGLE 6450 2 158-01  COVER DUAL 6450 2 158-02 Date Approved By: . & reliability: CAT 6 module: Meet & exceed Category 6 std. (ISO 11801 & TIA/EIA 568 -B. 2-1 ) CAT 3 module: Meet & exceed Category 3 std. (ISO. PPLICATION The HIGHBAND 25 RANGE of modules provides a 24 pair high-density, high performance, cost competitive Category 6 data grade module, (the 25 th

Ngày đăng: 18/10/2013, 13:15

TỪ KHÓA LIÊN QUAN