Kspace strategies

12 12 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 12
Dung lượng 2,17 MB

Nội dung

Cardiac Function K-space Techniques Non-segmented K-space ECG Trigger Acquisition Window Acquisition Window TR Echoes Cardiac Phases a a a a a a a a a a a aa ||||||||||||| N Heartbeat Echo a a a a a a a a a a a aa ||||||||||||| N Heartbeat Echo • Single echo measured for each phase • Temporal resolution very good • Scan duration very long Segmented K-space ECG Trigger Acquisition Window Acquisition Window TR Echoes Cardiac Phases aaaaaaaaaa aaaaa aaaaaaaaaa aaaaa 1234512345 12345 1234512345 12345 Heartbeat Echoes 1-5 N N Heartbeat Echoes 6-10 • Multiple echoes measured for each phase • Short scan duration but poor temporal resolution Echo-shared, Segmented K-space ECG Trigger Acquisition Window Acquisition TR Echoes a a a a a a a a a a a a a a a a 3 Cardiac Phases • • • • N Multiple echoes measured for odd phases Central echo measured for even phases Even phases interpolated between odd phases Short scan duration and good temporal resolution Real-time Single-Shot K-space (multiple slices, multiple phases, free-breathing) R ECG Trigger Acquired temp res about 150ms slice #1 Effective temp res about 75ms slice #2 With iPAT temp res about 50ms slice #3 slice # m ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| phase #1 #2 #3 #n Real-time Single-shot K-space • Benefit: Can be used non-triggered and free-breathing with multiple slices • However: Less temporal and spatial resolution than Segmented Echo-shared Real-time Multiple slices Free breathing Lower resolution Segmented Echo-Shared Only slice sec breath-hold Higher resolution Realtime TrueFISP Cine • short-axis cine slices covering from base to apex of heart, with matrix 70*128 • Acquired in 14 heartbeats with triggering and breath-hold, but it could have been untriggered and free-breathing for very sick patients • Each slice was triggered on an R-wave and cine images were acquired in rapid succession during the Acquisition Window • In non-triggered mode, Number of Phases is used to define how long the scan will run Radial K-space Sampling • Radial K-space trajectory • Higher spatial and temporal resolution • No phase wrap at smaller FOV • Isotropic in-plane resolution • Less sensitive to motion • Radial streaks more pronounced near edge FOV Cartesian K-space Radial K-space Shared-Echo Radial K-space Sampling Phase Phase Phase etc = Measured = Shared Radial Real-Time TrueFISP Cine Improved resolution in real-time • Cartesian Real-Time Cine • Echo-sharing • 50 lines • 55 msec frame rate • 300mm x 300mm FOV • 2.3mm x 6.0mm res • Radial Real-Time Cine • Interleaved Echo-sharing • 50 lines • 55 msec frame rate • 300mm x 300mm FOV • 2.3mm x 2.3mm res Radial Real-Time TrueFISP Cine No phase wrap at smaller FOV Cartesian Real-time Cine Radial Real-time Cine 50x64, Shared temporal res 65 ms, Small 140mm FOV Radial Real-Time vs Radial Segmented Radial Real-time Free Breathing Radial Segmented Breath-hold

Ngày đăng: 13/08/2020, 09:33