Shop manual máy đào HuynDai R250: An toan, cấu trúc, sơ đồ điện, thủy lực,
5-12GROUP 9 SELF-DIAGNOSTIC SYSTEMOUTLINEWhen any abnormality occurs in the NEW CAPO system caused by electric parts malfunction and byopen or short circuit, the CPU controller diagnoses the problem and sends the error codes to thecluster and also stores them in the memory. The current or recorded error codes are displayed at the error display mode selected by touchingSELECT switch 2 times while pressing BUZZER STOP switch. CURRENT ERROR DISPLAYCluster displays Co : Err and makes buzzer sound itself to warn the communication error whencommunication problem caused by wire-cut or malfunction of the CPU controller occurs.Cluster displays real time error codes received from CPU controller through communication. In caseof no problem it displays CHECKEr : 00.If there are more than 2 error codes, each one can be displayed by pressing and switchrespectively. Examples :1) Communication ErrorCo : Err & Buzzer sound2) No problemCHECKEr :3) 4 Error codes(03, 06, 10, 43) display CHECKEr :RECORDED ERROR DISPLAYThe recorded error can be displayed only when the key switch is at ON position.Examples : 5 Recorded error codes(03, 06, 10, 20, 32) displayTIMEEr :DELETE ALL RECORDED ERROR CODESSelect recorded error(TIMEEr) display and press engine and select switch at the same time for2 seconds or more. Cluster display changes to TIMEEr : 00, which shows that CPU controller deletedall the recorded error codes in the memory.1.2.3.4.0 00 30 3 0 6 1 04 3StartNo changePress0 3PressPressPressPressPress Press0 3 0 6 1 02 0StartPressPressPressPressPressPress3 2PressPressNo changePress 5-136. ERROR CODES TABLEError code No. DescriptionShort circuit in accel actuator systemPotentiometer circuit is shorted to Vcc(5V) or battery +Short circuit in pump EPPR valve systemShort circuit in boom down EPPR valve systemShort circuit in travel speed solenoid systemShort circuit in power boost solenoid systemShort circuit in max flow solenoid systemShort circuit in hour-meter systemAccel dial circuit is shorted to Vcc(5V) or battery +P1 pressure sensor circuit is shorted to power supply(24V) lineP2 pressure sensor circuit is shorted to power supply(24V) lineP3 pressure sensor circuit is shorted to power supply(24) lineBoom down pressure circuit is shorted to power supply(24V) lineAccel actuator circuit is open or shorted to groundPotentiometer circuit is open or shorted to groundPump EPPR valve circuit is open or shorted to groundBoom down EPPR valve circuit is open or shorted to groundTravel speed solenoid circuit is open or shorted to groundPower boost solenoid circuit is open or shorted to groundMax flow solenoid circuit is open or shorted to groundHour-meter circuit is open or shorted to groundAccel dial circuit is open or shorted to groundP1 pressure sensor circuit is open or shorted to groundP2 pressure sensor circuit is open or shorted to groundP3 pressure sensor circuit is open or shorted to groundBoom down pressure sensor circuit is open or shorted to groundEngine preheater circuit is open or shorted to groundTravel alarm buzzer circuit is open or shorted to groundAlternator circuit is open or shorted to groundController input voltage is below 18VController input voltage is over 38VCommunication error with clusterEngine speed sensor circuit is open or shorted to groundAnti-restart relay circuit is open or shorted to groundAccel actuator does not stop at a target positionThere is more than 500rpmdifference between target speed and actual speed12345671011121314151617181920212225262728293031323334353637383940 5-14Error code No. DescriptionHydraulic oil temperature sensor circuit is shorted to groundFuel level sensor circuit is shorted to groundCoolant temperature sensor circuit is shorted to groundBoom up pressure sensor circuit is shorted to power supply(24V) lineHydraulic oil temperature sensor circuit is open or shorted to battery +Fuel level sensor circuit is open or shorted to battery +Coolant temperature sensor circuit is open or shorted to battery +Boom up pressure sensor circuit is open or shorted to groundEngine preheater circuit is shorted to battery +Boom priority solenoid circuit is open or shorted to groundTravel alarm buzzer circuit is shorted to battery +Boom priority solenoid circuit is shorted to battery +414243444546474849515658 . target speed and actual speed1234567101112131415161718 192 0212225262728 293 03132333435363738 394 0 5-1 4Error code No. DescriptionHydraulic oil temperature. 5-1 2GROUP 9 SELF-DIAGNOSTIC SYSTEMOUTLINEWhen any abnormality occurs in the NEW CAPO