Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 154 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
154
Dung lượng
10,79 MB
Nội dung
by Leslie Alan Bowtell, MEng, BEng, RPEQ Dissertation Submitted in Fulfilment of the requirements for the degree of Doctor of Philosophy at the University of Southern Queensland Faculty of Engineering and Surveying November 2010 i Certification of Thesis I certify that the ideas, experimental work, results, analyses, software and conclusions reported in this dissertation are entirely my own effort, except where otherwise acknowledged I also certify that the work is original and has not been previously submitted for any other award, except where otherwise acknowledged _ Signature of Candidate Date ENDORSEMENT Signature of Supervisor _ Date Signature of Supervisor _ Date ii Acknowledgments I wish to convey my most sincere thanks to my supervisor Dr Tony Ahfock for his help throughout this project He has provided excellent supervision, skilful guidance and tactful mentoring from the inception of this project right through to the compilation of this thesis He has made this a rewarding although sometimes challenging experience for which I am sincerely grateful to have had such a gifted and fervent mentor I wish also to thank USQ’s technical staff, in particular Mr Don Gelhaar for his assistance in the Laboratory, and for his kind words of encouragement It also goes without saying that without the continuous support and motivation received from my family, particularly my wife Shelley, that this dissertation would not have been possible Lastly but certainly not least I wish to thank my three children for the tolerance and patience that they have shown me over the last three years and for foregoing all the weekend activities for which I am now once again available iii Abstract i Certification of Thesis ii Acknowledgements iii Contents iv List of Tables ix List of Figures x List of Symbols xiii Publications xv Introduction 1.1 Justification for the Research Project 1.2 Aims and objectives 1.3 Outline of Dissertation 1.4 Summary of Outcomes Common Inverter Control Strategies 2.1 Inverter Control Strategies 2.2 Voltage versus Current Control 2.3 Inverter Switching Methodologies 2.4 2.5 2.3.1 Bipolar Switching 10 2.3.2 Unipolar Switching 11 System Control Loops 12 2.4.1 DC Bus Voltage Control 13 2.4.2 Maximum Power Tracker 15 Potential for Cost and Performance improvement 19 iv Literature Review and Project Plan 3.1 Review of Literature 3.2 20 20 3.1.1 DC Offset Control 20 3.1.2 Output Current Harmonic Distortion 24 Project Plan 28 Selection of Inverter Topology 4.1 Comparison of Bipolar and Unipolar Control 29 4.2 Bipolar Switching without Ripple Filter 31 4.3 The Ripple Filter 34 4.4 Filter Damping 38 4.5 Bipolar Switching with Ripple Filter 43 4.6 Expected Switching Loss Reduction with Unipolar Switching 46 4.7 Unipolar Switching without Ripple Filter 48 4.8 Unipolar Switching with Ripple Filter 51 4.9 Mixed Bipolar and Unipolar Switching 53 4.10 The Effect of Delay 57 4.11 The Effect of Delay on Bipolar Switching 60 4.12 Modelling of Switching Delay 61 4.13 Compensation for the Effect of Delay 63 4.14 Thermal Tests 66 4.15 Summary 68 v DC Bus Voltage Controller 5.1 Introduction 69 5.2 Maximum Power tracker 71 5.3 DC Bus Voltage Controller 73 5.4 Dynamic Analysis of the DC Bus Voltage Controller 76 DC Offset Control 6.1 6.2 6.3 6.4 6.5 Introduction 79 RLLC Sensor Based DC Offset Controller 80 6.2.1 Mathematical Model 81 6.2.2 Controller Design 85 6.2.3 87 Test Results Dual-Stage RC Sensor Based DC Offset Controller 90 6.3.1 Mathematical model 91 6.3.2 Controller design 94 6.3.3 Test Results 98 Dual-Stage RC Based Digital DC Offset Controller 100 6.4.1 Mathematical Model 103 6.4.2 Controller Design 104 6.4.3 Test Results 108 DC Offset and Bus Voltage Controller Interaction 111 vi Conclusions 7.1 DC Offset Control 116 7.2 Reduction in Current Distortion 117 7.3 Summary 120 References 121 Appendix A 126 A.1: System Overview 127 A.2: Illustration of Inverter Non-Unity Power Factor Operation 129 A.3: Zero Phase-Shift Filter 130 A.4: Effectiveness of Zero Phase-Shift Filter 131 A.5: Active and Reactive Components of khiref 132 A.6: Bipolar Current Controller 133 A.7: Unipolar Current Controller 134 A.8: Multi-Mode Controller Schematic 135 A.9: Mode Change-Over Circuit 137 A.10: Analogue PI Controller 138 Appendix B 139 B.1: 139 Switching Delay vii List of Tables Table 4.1: Filter Power Loss Comparison 41 Table 4.2: Unipolar Switching Logic 49 Table 4.3: Multi-mode Switching Logic 54 Table 4.4: Thermal Rise Temperature Tests 67 Table 6.1: DC Offset Controller Design Parameters 97 Table 6.2: DC Offset Currents at Various Inverter Output Levels viii 114 List of Figures Figure 1.1: Essential Components of a Grid-Connected Photovoltaic System Figure 2.1: Output Voltage from Unipolar Switched Inverter Figure 2.2: Output Voltage from Bipolar Switched Inverter Figure 2.3: Typical Unfiltered Output Current of a Current Controlled Inverter Figure 2.4: Current Controlled Grid Connected Full Bridge Inverter Figure 2.5: Inverter and Bus Voltage Control Loop 14 Figure 2.6: PV Array Characteristic at Given Insolation and Temperature 15 Figure 2.7: The Need for Maximum Power Tracking 16 Figure 2.8: Grid Connected PV System with Maximum Power Tracker 17 Figure 4.1: Inverter Components including LCL filter 30 Figure 4.2: Simplified Bipolar Inverter Control model 31 Figure 4.3: Hysteretic control (no ripple filter) 32 Figure 4.4: Simplified bipolar inverter circuit 32 Figure 4.5: Theoretical Bipolar operation 2.0A 33 Figure 4.6: Experimental Bipolar operation 2.0A 33 Figure 4.7: LCL Filter Components 34 Figure 4.8: Undamped filtered waveform 38 Figure 4.9: Filter Damping Options 39 Figure 4.10: Simulink Model of the LCL Filter 43 Figure 4.11: Theoretical and Experimental LCL Filter Effect 44 Figure 4.12(a): Damping Performance of Rp (simulated) 45 Figure 4.12(b): Damping Performance of Rr (simulated) 45 Figure 4.13: 48 Unipolar Switched Inverter Model ix Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 125 [42] Semikron Data Book part number 11 23 21 70 DM10,pp B6-117, 1999 [43] Semikron , “P3/300 Heatsink”, part number SEMIKRON_308055_P3_300, 2005 [44] F.Frohr, Electronic Control Engineering Made Easy, Siemens, Germany, pp.40-42, 1985 [45] F.H Raven, “Automatic Control Engineering”, McGraw-Hill Book Company, 1968 [46] R.Sharma, “Single-phase Transformerless Unipolar Switched Inverters for UtillityConnected Photovoltaic Applications”, Doctoral Thesis, University of Southern Queensland, Australia, 2007 [47] Semikron Power Electronics, “SKM 100 GB 123D”, pp B6-41, 1999 [48] LEM Components, “Isolated Current and Voltage transducers, Characteristics— Applications— Calculations,” 3rd edition, Publication CH 24101 E/US 2004 [49] Intersil, “X9 C103 digitally controlled potentiometer” FN8222.1September 19, 2005 [50] Motorola, Linear/Interface ICs Device Data Handboook, DL128/D, rev 4, section 2, pp.58-60, 1993 [51] M.Ordonez, J.E.Quaicoe, and M.T.Iqbal, “Advanced Boundary Control of Inverters Using the Natural Switching Surface:Normalized Geometrical Derivation”, Proc of PESC 2008, pp.4303-4043, June 2008 [52] Li, R.T.H, and Chung, H.S.H, “application of hybrid PWM and passive resonant snubber for grid-connected CSI,”Proc of IEEE Power Electronics Specialists Conference, pp837-843, 2008 Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Appendix A A.1: System Overview A.2: Illustration of Inverter Non-Unity Power Factor Operation A.3: Zero Phase-Shift Filter A.4: Effectiveness of Zero Phase-Shift Filter A.5: Active and Reactive Components of khiref A.6: Bipolar Current Controller A.7: Unipolar Current Controller A.8: Multi-Mode Controller Schematic A.9: Mode Change-Over Circuit A.10: Analogue PI Controller Page 126 Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 127 A.1: System Overview Figure A.1: System Overview Block Diagram This appendix provides a description of the hardware used to implement the inverter As shown in figure A.1 the software platform used was the Siemens CPU244XP programmable controller This industrial controller was chosen because of its compliance to European Community (CE) EMC Directive 89/336/EEC and noise immunity under EN61000 6—21, ease of programming and ease of interfacing with other hardware Software developed as part of this project consisted of the DC offset controller (chapter 6), the inverter current controller switching mode selector (chapter 4) and the maximum power tracker (chapter 5) While a reactive power controller was not developed, the inverter had reactive power injection capability (as illustrated by figure A.2) Apart from the programmable controller, figure A.1 represents other hardware modules which are described in detail in the following pages Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters A.2: Illustration of Inverter Non-Unity Power Factor Operation Figure A.2: Inverter Output Current Leading supply voltage by 81° Page 128 Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 129 A.3: Zero Phase-Shift Filter Figure A.3: Zero Phase-Shift Filter Circuit An AC signal synchronised with the AC supply voltage is needed for the generation of the reference current iref which, as shown in figure A.1, is the input to the current controller Reference current iref is the output of the zero-phase shift filter shown in figure A.3 A 240V/12V 50Hz miniature transformer is used to obtain a reference signal (approximately 5V rms) in phase with the supply voltage Because of the undesirable presence of harmonics, the signal is filtered As shown in figure A.3, the overall transfer function for the two stage filter is: where R = R1 = R2 and C = C1 + C2 have been chosen so that fo = 50Hz This implies that the filter has the desirable effect of practically zero phase-shift at 50Hz while having significant attenuation at higher harmonic frequencies Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 130 A.4: Zero Phase-shift Filter Effectiveness Figure A.4: Zero Phase-shift Filter Effect Figure A.4 shows that the output of the filter is significantly less distorted when compared to the raw AC signal A significant reduction in the total harmonic distortion (THD), and higher frequency harmonics as shown in the respective waveform spectra, was also achieved Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 131 A.5: Active and Reactive Components of khiref Figure A.5: Active and Reactive Component of khiref The 5V output (S) from the zero phase-shift filter circuit is used to generate the current reference signal khiref as shown in figure A.5 Digital potentiometer DP is used to generate the active component of khiref As described in chapter the digital potentiometer DP1 is adjusted according to the output of the DC bus voltage controller to maintain active power balance To create a signal for the reactive component of khiref , signal S from the zero phase-shift filter is phase shifted by 90o The 90o phase shifter is realised by components R1, C1, R2, C2 and differential amplifier DA1 The output of DA1 is of nominally fixed magnitude Digital potentiometer DP2, and the voltage divider made up of R3 and R4 and differential amplifier DA2 allows the 90 o phase shifted signal to be adjusted from to a maximum value of 4V leading or lagging Digital potentiometer DP2 is adjusted via software within the programmable controller The reactive component of khiref is maximum and lagging when DP2 is at the zero position When the output terminal of DP2 is in its middle position the reactive component of khiref is zero The reactive component of khiref is maximum and leading when DP2 is at its maximum position As described in chapters and 6, the summer circuit combines active and reactive power references with DC offset Control to produce the reference current signal khiref Power Quality and Efficiency Improvements for Transformerless Transformerless Grid Connected PV Inverters Page 132 A.6: Bipolar Current Controller Figure A.6:: Current Controller (bipolar) Figure A.6 shows the current controller used for the bipolar switching mode The inverter current signal khii and the reference signal khiref are compared by the comparator (LM339b) The comparator circuit incorporates an inbuilt inbuilt hysteresis band given by: Since kh was 1.25V/A, this corresponds to a nominal tolerance band of ±0.3A However, in practice, as can be seen for example in figure A.2, A.2, the tolerance band appears wider due to the effects of delay in controller circuit The output of the comparator goes high hig when khii goes lower than kh(iref – Itol/2) This results in transistors TA+ and TB- of the inverter being turned on and TA- and TB+ being turned off The output of the comparator goes goe low when khii goes higher than kh(iref + Itol / 2) This results in inverter transistors TA- and TB+ being turned on and TA+ and TB- being turned off Components R19, C3, inverting buffers N10 and N9, and AND gates A13 and A14 are used to provide the required blanking time when the inverter transistors are switching states While turn-off turn happens without intentional delay, turn-on turn on is delayed by an amount determined by the product produc of the resistance of R19 and capacitance of C3 Their values were chosen to give a blanking blanki time of 2.2 s Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 133 A.7: Unipolar Control Circuit +5V Vs R3 DP1 R1 Delay Compensation Differential Amplifier +5V DP1 +5V DP1 R4 Icomp R2 Figure A.7: Current Controller Circuit (Unipolar) Figure A.7 shows the current controller for unipolar switching The bottom section which is used to control inverter transistors TA+ and TA- is identical to the previously described bipolar controller shown in figure A.4 The top section is used to control inverter transistors TB+ and TB- The aim is to have TB+ on during the positive half cycle of the AC supply voltage and TB- on during the negative half cycle The output of the comparator (LM339a) is high during the positive half cycle and low during the negative half cycle This results in TB+ being on during the positive half cycle and TB- being on during the negative half cycle Components R7, C1, inverting buffer N1, and AND gates A1 and A5 are used to provide a blanking time of s when the transistors change states Power Quality and Efficiency Improvements for Transformerless Transformerless Grid Connected PV Inverters Page 134 A.8: Multi-Mode Mode Controller Schematic T T T T Figure A.8: Mode Control Circuit As elaborated in chapter the inverter is capable of operating in three modes That is in: bipolar mode, unipolar mode and multi-mode multi mode Mode control is carried out by the circuit in i figure A.8 The programmable controller outputs outputs an analogue signal Vbi which determines the mode of operation Comparator C1 compares Vbi with the AC supply voltage signal ksvs whereas comparator C2 compares –ksvs with Vbi If Vbi is made higher than the peak value of ksvs , then the outputs of the comparators are both low and constant Potentiometer P3 is adjusted to provide a positive voltage of about 1V at the inputs of comparators C3 and C4 Therefore when Vbi is greater than the peak value of kavs, the output of the non-inverting inverting buffer B1 is high whereas the output of non-inverting non buffer B2 is low This means that if Vbi is greater than the peak value of kavs purely bipolar operation results Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 135 If Vbi is made negative, then the outputs of comparators C1 and C2 are both high and constant This causes Vx to be equal to the positive supply rail voltage, resulting in the output of the non-inverting buffer B1 to be low and the output of non-inverting buffer B2 to be high This means that if Vbi is less than zero then purely unipolar operation results If Vbi falls between zero and the peak value of kavs then multi-mode operation is the result That is, as shown in figure A.8, for time interval Tbi , centred around the zero crossing of the AC supply voltage vs , operation is bipolar Operation is unipolar for the rest of the time Components R20, C4, R21 and C5 provide a short blanking time during transition from unipolar operation to bipolar operation and vice-versa The blanking time is achieved by allowing the outputs of B1 and B2 to change instantaneously from high to low, but delaying the reverse transition The values chosen for the RC circuit resulted in a blanking time of 1.2 s Power Quality and Efficiency Improvements for Transformerless Transformerless Grid Connected PV Inverters Page 136 A.9: Mode Changeover Circuit Figure A.9: Mode Changeover Circuit The output signals from the bipolar current controller controller (figure A.6), the unipolar current controller (figure A.7) and the mode control circuit circui (figure A.8) are combined in figure A.9 to generate signals for the gate drive circuit Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 137 A.10: Analogue PI Controller Figure A.10: Analogue PI Controller The analogue DC offset PI controllers (sections 6.2 and 6.3) were implemented using the circuit in figure A.10 Operational amplifier A1 is used to implement both the proportional and integral control terms The transfer function is given by: where: R = setting of VR1 τi = integration time constant = RC1 Operational amplifier A2 and components D2, C2, R3 and P1 prevent the compensating current signal (khic) from going above the value set by potentiometer P1 This value was set at 200mV Similarly operational amplifier A3 and components D1, C3, R4 and P2 prevent the compensating current signal (khic) from going below the value set by potentiometer P2 Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 138 With the system operating within limits set by P1 and P2 both D1 and D2 are reverse biased and the limiting circuits have no effect Now consider the situation when the output attempts to go above the limit set by P1 This attempt will have no effect on the output of A3 which remains saturated near the negative supply rail causing D1 to remain reverse biased The output of A2, however, quickly drops from its saturated value near the positive supply rail because of the relatively small value of capacitance C2 The value of the output of A2 will remain at exactly one diode voltage drop below zero as long as the voltage input from the DC offset sensor is above zero As soon as the input voltage from the DC offset sensor goes below zero D2 becomes reverse biased and integration resumes The scenario is similar when the bottom limit is reached Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page 139 B.1: Switching Delay B.1: Typical IGBT Switching Waveforms Showing Delays The inverter was implemented using Semikron®SKM100GB063D half bridge IGBT modules and the Semikron® SKHI22B isolated dual gate drive modules The choice of gate drive resistance was a compromise between switching speed, switching losses and EMI generation The gate drive resistances chosen were 68 for turn on and 27 for turn off Figure B.1 shows typical turn on and turn off delays Turn on delay shown could be reduced by approximately to microseconds depending on the physical parameters such as cable length to the solar array ... Single-phase Grid- connected Photovoltaic Inverters , IET Renewable Power and Generation,(submitted, Nov 2010) xiv Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters. .. significance Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters Page A single phase transformerless grid- connected photovoltaic system has been implemented and tested... Single-phase Grid- connected Photovoltaic Inverters , IET Renewable Power and Generation,(submitted, Nov 2010) Power Quality and Efficiency Improvements for Transformerless Grid Connected PV Inverters