CG2-200 2V 200Ah(10hr) Gel battery shows some distinctive advantages over flooded battery or AGM battery, such as super thermal stability, high deep discharge capability, good recovery from deep discharge , even if the battery is left discharged for three days, it will recover to 100% of capacity With the above-mentioned advantages, the gel battery has long service life, specially suitable for motive power applications, such as golf trailer, sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with the AGM battery Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Raw material Lead dioxide Lead ABS ABS Rubber Copper General Features ● Nanometer SiO and H SO gelled electrolyte technology for efficiency gas recombination of up to 99% and freedom from electrolyte maintenance or water adding ● Not restricted for air transport-complies with IATA/ICAO Special Provision A67 ● UL-recognized component ● Can be mounted in any orientation ● Computer designed lead, calcium tin alloy grid for high power density ● Long service life, float or cyclic applications ● Maintenance-free operation ● Low self discharge ● Case and cover avaiable in both standard and flame restardant ABS Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx Weight(Kg / lbs) 173 / 6.81 111 / 4.37 330 / 13.0 364 / 14.3 15.2 / 33 Separator PVC Electrolyte Gelled acid Performance Characteristics Nominal Voltage 2V Number of cell Design Life 20 years Nominal Capacity 77oF(25oC) 10 hour rate (20.0A, 1.80V) 200Ah hour rate (35.2A, 1.75V) 176Ah hour rate (124A, 1.6V) 124Ah Internal Resistance ≤ 0.8mOhms Fully Charged battery 77oF(25oC) Self-Discharge 2% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC 440A(5s) Max Discharge Current 77oF(25oC) Charge Methods: Constant Voltage Charge 77oF(25oC) Cycle use Charge Voltage: 2.40-2.45VPC Maximum charging current 40A -5mV/ oC Temperature compensation Standby use 2.20-2.30VPC -3.3mV/ oC Temperature compensation * Weight deviation: ± 3% Discharge Constant Current (Amperes at 77oF25oC) End point 10min 15min 30min volts/cell 1.60V 420 344 200 1.65V 396 320 196 1.70V 372 304 192 1.75V 348 280 188 1.80V 324 256 180 1h 3h 5h 10h 20h 124 120 116 112 106 52.0 50.7 49.3 48.7 46.7 38.0 36.8 36.0 35.2 34.0 21.0 20.4 20.4 20.2 20.0 11.2 11.0 10.8 10.7 10.5 Discharge Constant Power (Watts at 77oF25oC) End point 10min 15min volts/cell 1.60V 719 583 1.65V 684 579 1.70V 667 554 1.75V 635 520 1.80V 601 492 Total height with removeable cover: 364 30min 1h 3h 5h 10h 20h 374 358 341 331 317 232 221 212 204 195 97.3 92.4 87.6 83.3 78.4 73.0 68.9 65.7 64.2 59.8 40.7 36.9 36.2 34.9 32.6 22.0 20.8 19.9 19.2 18.5 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values All data shall be changed without notice,Vision reserves the right to explain and update the information contained hereinto page1 of www.vision-batt.com CG2-200 O 0.17 2.40 100 0.14 2.20 35.2A 20A 200A 124A 80 60 40 1.60 0.05 1.40 12 16 20 24 Self-discharge characteristic 110 (V/CELL) 100 Capacity(%) (V/6V) (V/4V) Charging time (hours) Relationship between charging voltage and temperature (V/8V) 100%(0.1CAx10H) 50%(0.1CAx5H) Charge Charge Voltage(2.45V/Cell) Charge Current 0.1CA o Temperature25 C 1.80 0.08 Discharge time (V/12V) Discharge 2.00 0.11 0.02 20 )Ratio Voltage(V)/PerCell 420A 120 ChargeCurrent(CA) 48.7A Charging characteristic for Cycle use Charged Volume(%) Battery voltage(V) Discharge characteristic (25 C) 2V 200Ah 90 15.6 10.4 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 60 13.2 8.8 6.6 4.4 2.2 50 -10 10 20 30 40 50 80 70 40 60 Ambient temperature( oC) 12 15 18 21 Storage time: months 24 27 Cycle service life in relation to depth of discharge Capacity(%) Life characteristics of Standby use 50% Depth of discharge Number of cycles(cycles) Life(year) Temperature effects on capacity Capacity (%) Life(years) Temperature effects on float life Temperature( oC) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2008 MH25860 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech Co., Ltd Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1) Page of 30 .. .CG2- 200 O 0.17 2.40 100 0.14 2.20 35.2A 20A 200A 124A 80 60 40 1.60 0.05 1.40 12 16 20 24 Self-discharge characteristic... ISO9001 :2008 MH25860 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech Co., Ltd Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel:... characteristic for Cycle use Charged Volume(%) Battery voltage(V) Discharge characteristic (25 C) 2V 200Ah 90 15.6 10.4 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 60