6FM230D-X 12V 230Ah(20hr) The rechargeable batteries are lead-lead dioxide systems The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized Should the battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid General Features ● ● ● ● ● ● ● ● Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding Not restricted for air transport-complies with IATA/ICAO Special Provision A67 UL-recognized component Can be mounted in any orientation Computer designed lead, calcium tin alloy grid for high power density Long service life, float or cyclic applications Maintenance-free operation Low self discharge Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx Weight(Kg / lbs) 520 / 20.5 269 / 10.6 203 / 8.0 208 / 8.2 72.6 / 160.1 Performance Characteristics Nominal Voltage 12V Number of cell Design Life 10 years o o Nominal Capacity 77 F(25 C) 20 hour rate (11.5A, 10.8V) 230Ah 10 hour rate (21.0A, 10.8V) 210Ah hour rate (40.3A, 10.5V) 201.5Ah 150Ah hour rate (150A, 9.6V) Internal Resistance 2.8mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 1100A(5s) Max Discharge Current 77 F(25 C) Short Circuit Current 4300A Charge Methods: Constant Voltage Charge Cycle use Maximum charging current Temperature compensation Standby use Temperature compensation 77oF(25oC) 2.30-2.35VPC 63A -30mV/oC 2.23-2.27VPC -20mV/oC Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 10min 15min 30min 45min 1h 3h 5h 10h 20h 1.60V 523 395 232 180 150 68.5 41.0 21.8 1.65V 506 384 231 176 147 68.2 40.8 21.6 9.9 10.2 1.70V 475 373 230 174 145 67.8 40.6 21.4 1.75V 442 362 226 172 144 66.8 40.3 21.2 10.6 11.1 1.80V 413 350 223 170 142 66.5 40.0 21.0 11.5 Discharge Constant Power (Watts at 77oF25oC) End Point Volts/Cell 10min 15min 30min 45min 1h 1.60V 930 640 439 341 1.65V 905 630 436 339 1.70V 870 624 432 1.75V 825 610 429 2h 3h 5h 286 172 131 86.7 284 171 130 86.4 327 280 169 129 86.1 325 278 168 128 85.8 1.80V 770 600 425 322 275 166 126 85.4 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values page1 of www.vision-batt.com O Current Charged Volume Discharge characteristic (25 C) Voltage 6FM230D-X Charge characteristic curve Constant voltage charge characteristic (0.25CA,25 oC) (%) (XCA) (V) 12.0 12V230Ah Battery voltage(V) 140 66.8A 40.3A 9.6 21.0A 120 0.25 100 0.20 80 215A 150A 440A 0.15 20 30 10 60 10 20 0.10 20 0.05 0 h CHARGED VOLUME 14.0 CHARGE VOLTAGE 13.0 60 40 15.0 12.0 11.0 Discharge time (V/8V) (V/6V) (V/4V) (V/CELL) 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 9.2 6.9 4.6 2.3 13.2 8.8 6.6 4.4 2.2 CY CL ND B EU SE 12 14 16 18 20 Y US 12 14 16 18 Storage time: months 20 80 70 60 E 40 oC 30 oC 20 oC 50 10 20 30 40 50 Ambient temperature( oC) 40 60 10 Cycle service life in relation to depth of discharge Life characteristics of standby use 120 100 100 Capacity(%) Capacity(%) 10 90 120 80 60 Testing conditions: floating voltage: 2.27 to 2.30V/Cell ambient temperature: 25 oC(77 oF) 80 60 40 40 20 20 Life(year) 100% D.O.D 200 30% Depth of discharge 50% D.O.D 400 600 800 1000 1200 1400 1600 Number of cycles(cycles) Temperature effects on float life Temperature effects on capacity 120 15 100 C 0 C C 2.30V/Cell 10 Capacity (%) Life(years) 100 -10 110 S TA 13.8 Self-discharge characteristic Capacity(%) (V/12V) 10.4 Charging time (hours) Relationship between charging voltage and temperature 15.6 CHARGING CURRENT 80 60 1.0C 40 2.0C 20 10 20 30 40 50 -20 -10 o Temperature( C) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2000 MH25860 10 20 Temperature( oC) 30 40 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech Co., Ltd Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8) Page of 50 ... Volume Discharge characteristic (25 C) Voltage 6FM230D- X Charge characteristic curve Constant voltage charge characteristic (0.25CA,25 oC) (%) (XCA) (V) 12.0 12V230Ah Battery voltage(V) 140 66.8A... Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com Copy Right Shenzhen Center