1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Hatco AWD

16 100 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 16
Dung lượng 250,64 KB

Nội dung

ATMOSPHERIC Hot Water Dispenser AWD-12 Series Installation & Operating Manual I&W #07.05.126.00 This manual contains important safety information concerning the maintenance, use and operation of this product Failure to follow the instructions contained in this manual may result in serious injury If you are unable to understand the contents of this manual, please bring it to the attention of your supervisor Do not operate this equipment unless you have read and understood the contents of this manual Downloaded from www.Manualslib.com manuals search engine Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio daño Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor No opere este equipo al menos que haya leído y comprendido el contenido de este manual CONTENTS Operation Start-Up Dispensing Hot Water .5 Error Codes .6 Programming the Dispenser Maintenance General Cleaning Dispenser Exterior Draining the Dispenser De-Liming the Dispenser .8 Resetting the High Temperature Safety Switch Hatco Limited Warranty 10 Authorized Parts Distributors Back Cover Important Owner Information .i Introduction i Important Safety Instructions .1 Model Descriptions All Models Specifications .2 Plug Configurations .2 Electrical Rating Chart Dimensions Statistics Installation Location Plumbing Electrical IMPORTANT OWNER INFORMATION Business Hours: Record the model number, serial number (identification decal located on the lower side of the unit), voltage and purchase date of your Atmospheric Hot Water Dispenser in the spaces below Please have this information available when calling Hatco for service assistance 8:00 a.m to 5:00 p.m Central Standard Time (Summer Hours: June to September – 8:00 a.m to 5:00 p.m C.D.T Monday through Thursday 8:00 a.m to 2:30 p.m C.D.T Friday) Telephone: (800) 558-0607; (414) 671-6350 Model No Fax: Serial No Voltage Date of Purchase (800) 690-2966 (Parts & Service) (414) 671-3976 (International) 24-Hour 7-Day Parts & Service Assistance available in the United States and Canada by calling (800) 558-0607 Additional information can be found by visiting our web site at www.hatcocorp.com INTRODUCTION Hatco Atmospheric Hot Water Dispensers are designed to deliver pre-measured quantities of hot water for food preparation or cleaning A 12 gallon (45 liter) stainless steel tank provides up to gallons (30 liters) of continuous, temperature controlled water ranging from 75°–195°F (24°–91°C) The tank may be emptied easily using the convenient bottom drain are factory-assembled and ready for installation This manual provides the installation, safety and operating instructions for the Atmospheric Hot Water Dispensers We recommend all installation, operating and safety instructions appearing in this manual be read prior to installation or operation of your Hatco Atmospheric Hot Water Dispenser Safety instructions that appear in this manual after and the words WARNING a warning symbol or CAUTION printed in bold face are very WARNING means there important is the possibility of serious injury or death CAUTION means there to yourself or others is the possibility of minor or moderate injury CAUTION without the symbol signifies the possibility of equipment or property damage only Hatco Atmospheric Hot Water Dispensers design features include an electronic temperature controller with a digital temperature display, On/Off switch, preset dispenser pushbuttons, including a manual dispense function Standard equipment includes a stainless steel base, a white granite powder coated body, 4" (10 cm) legs and a 6' (2 mm) electrical cord and plug All electric heating elements are metal sheathed and controlled by a submersed thermistor The units are protected with a hightemperature limit switch and low-water cutoff Hatco Atmospheric Hot Water Dispensers are a product of extensive research and field testing The materials used were selected for maximum durability, attractive appearance and optimum performance Every unit is thoroughly inspected and tested prior to shipment The unit electrical and plumbing connections Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine i IMPORTANT SAFETY INSTRUCTIONS IMPORTANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property WARNINGS CAUTIONS Locate the dispenser at the proper counter height, in an area that is convenient for use The location should be level to prevent the unit or its contents from accidentally falling, and strong enough to support the weight of the unit and water supplied Plug unit into a properly grounded electrical outlet of the correct voltage, size and plug configuration If the plug and receptacle not match, contact a qualified electrician to determine the proper voltage and size and install the proper electrical outlet To avoid any injury, turn the power switch off at the fuse disconnect switch/circuit breaker or unplug the unit from the power source and allow to cool completely before performing any maintenance or cleaning Unit is not weatherproof For safe and proper operation locate the unit indoors where the ambient air temperature is a minimum of 70°F (21°C) To avoid any injury, turn the power off to the unit and allow to cool before draining To assure proper operation and to avoid damage to the unit, the incoming water supply pressure must be at least 35 psi (241 kPa) and not exceed 80 psi (552 kPa) To avoid any injury or damage to the unit not pull unit by power cord To assure proper operation and to avoid damage to the unit, the incoming water supply temperature must not exceed 140°F (60°C) To prevent any injury, discontinue use if power cord is frayed or worn For proper plumbing installation conforming to local plumbing codes, consult a licensed plumbing contractor CAUTIONS Water dispensed is very HOT Use proper container for holding hot water The unit must be transported in an upright position If laid on its side, the water must be drained from the unit If service is required on this unit, contact your Authorized Hatco Service Agent, or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966 or international fax 414-671-3976 Do not use deionized water Deionized water will greatly shorten the life of the water heating elements and plumbing components Water Quality Requirements – Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of hardness per liter) must be treated and softened before being supplied to an Atmospheric Hot Water Dispenser Water containing over 3.0 GPG (.75 GPL) will decrease the efficiency and reduce the operating life of the unit This product has no “user” serviceable parts To avoid damage to the unit or injury to personnel, use only Authorized Hatco Service Agents and Genuine Hatco Parts when service is required Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used Some aftermarket or generic replacement parts not have the characteristics that will allow them to operate safely in Hatco equipment It is essential to use Hatco Replacement Parts when repairing Hatco equipment Failure to use Hatco Replacement Parts may subject operators of the equipment to hazardous electrical voltage, resulting in electrical shock or burn Do not overtighten plumbing connections Overtightening may cause leaks Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 MODEL DESCRIPTIONS ALL MODELS Hatco Atmospheric Hot Water Dispensers are equipped with an electronic temperature controller, an On/Off switch, a digital temperature display, preset dispensing push-buttons, including a manual dispense function Electric heating elements are metal sheathed and controlled by a submersed thermistor The units are protected with a high-temperature limit switch and low-water cut-off Standard equipment includes a stainless steel base, a white granite powder coated body, 4" (102 mm) legs, tank drain and a 6' (2 m) electrical cord and plug A 12 gallon (45 liter) stainless steel tank provides up to gallons (30 liters) of continuous, temperature controlled water ranging from 75°-195°F (24°-91°C) Figure Model AWD-12 SPECIFICATIONS PLUG CONFIGURATIONS Units are supplied from the factory with an electrical cord and plug installed Plugs are supplied according to the applications as shown in Figure WARNING Plug unit into a properly grounded electrical outlet of the correct voltage, size and plug configuration If the plug and receptacle not match, contact a qualified electrician to determine the proper voltage and size and install the proper electrical outlet NEMA 6-30P *NEMA L6-30P is a locking plug available as a factory installed option Figure Plug Configurations WARNING To avoid any injury or damage to the unit not pull unit by power cord WARNING To prevent any injury, discontinue use if power cord is frayed or worn Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine NEMA L6-30P* SPECIFICATIONS ELECTRICAL RATING CHART Model AWD-12 Voltage Kilowatts (kW) Phase Amps Plug Configuration Shipping Weight† 208 24.0 NEMA 6-30P* 80 lbs (36 kg) 240 20.8 NEMA 6-30P* 80 lbs (36 kg) * NEMA L6-30P is optional † Unit weight, filled to 12 gallon (45 liters) capacity is 180 lbs (82 kg) DIMENSIONS Model AWD-12 Width Depth Depth Height (A) (B) (C) (D) 13-3/8" 23-1/2" 27-1/2" 28-1/8" (340 mm) (597 mm) (699 mm) (714 mm) A B D C Figure Dimensions WATER TEMPERATURE RECOVERY TABLE Model kw Degrees of Rise 60°F AWD-12 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F 150°F 160°F 33 gph 29 gph 25 gph 22 gph 20 gph 18 gph 17 gph 15 gph 14 gph 13 gph 12 gph NOTE: gph is gallons per hour COLD-START HEAT-UP TIME Model AWD-12 kw Degrees of Rise 60°F 90°F 140°F 22 Minutes 33 Minutes 52 Minutes WATER TEMPERATURE RECOVERY TIME Model AWD-12 kw Degrees of Rise 60°F 90°F 140°F 15 Minutes* 22 Minutes* 35 Minutes* * Recovery times are after 9.75 gallons of water have been dispensed Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 INSTALLATION LOCATION CAUTION The unit must be transported in an upright position If laid on its side, the water must be drained from the unit Gate or Ball Valve WARNING To avoid any injury or damage to the unit not pull unit by power cord CAUTION Unit is not weatherproof For safe and proper operation locate the unit indoors where the ambient air temperature is a minimum of 70°F (21°C) Water Inlet CAUTION Locate the dispenser at the proper counter height, in an area that is convenient for use The location should be level to prevent the unit or its contents from accidentally falling, and strong enough to support the weight of the unit and water supplied Figure Plumbing for AWD-12 CAUTION To assure proper operation and to avoid damage to the unit, the incoming water supply temperature must not exceed 140°F (60°C) PLUMBING WARNING For proper plumbing installation conforming to local plumbing codes, consult a licensed plumbing contractor NOTE: If required, a ball valve or gate valve, line strainer, union(s) and vacuum breaker or other anti-siphon device must be supplied by plumber or installer CAUTION Water Quality Requirements – Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of hardness per liter) must be treated and softened before being supplied to an Atmospheric Hot Water Dispenser Water containing over 3.0 GPG (.75 GPL) will decrease the efficiency and reduce the operating life of the unit Tighten connections securely Turn on water supply and check for leaks A drain connection is located under the unit for manually draining the dispenser A male hose connector is included See MAINTENANCE for draining information CAUTION Do not overtighten plumbing connections Overtightening may cause leaks NOTE: A 3/4" (19 mm) flexible hose may be connected to the heater sump drain and run to an open sight drain See Figure The sump drain should not be permanently connected to the sanitary drain system Check local plumbing code for proper drain installation CAUTION Do not use deionized water Deionized water will greatly shorten the life of the water heating elements and plumbing components ELECTRICAL Connect a flexible water supply line to the inlet on the unit using 1/4" NPT adapter with flare connection (or by using optional 1/4" inlet tubing supplied by Hatco) See Figure WARNING Plug unit into a properly grounded electrical outlet of the correct voltage, size and plug configuration If the plug and receptacle not match, contact a qualified electrician to determine the proper voltage and size and install the proper electrical outlet NOTE: Water inlet and drain connections must be made with flexible hose CAUTION To assure proper operation and to avoid damage to the unit, the incoming water supply pressure must be at least 35 psi (241 kPa) and not exceed 80 psi (552 kPa) Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine OPERATION START-UP NOTE: Make sure manual drain lever is in the horizontal (closed) position See Figure Place power switch in the ON position The electronic display will light up to indicate power is supplied to the unit See Figure Auto Stop/Manual Dispense Button The display will show E3 indicating that the heating elements are not yet submersed (water should be filling the tank at this point) When the tank water level reaches the low water probe the display will show the current water temperature and a small red light will glow in the upper left-hand corner of the display indicating that the heating elements are energized Figure Control Panel Water will continue to fill the tank until the upper water probe has been satisfied and the heating elements will remain on until tank water reaches the programmed temperature setpoint When the display shows the desired water temperature, generally 195°F (91°C), the unit is ready to dispense water NOTE: A temperature setting higher than 195°F (91°C) may cause nuisance tripping of the high limit switch and is not recommended If temperature adjustments are required see PROGRAMMING THE DISPENSER To reset the high limit switch, see RESETTING THE HIGH TEMPERATURE LIMIT SWITCH NOTE: If temperature adjustments are required see PROGRAMMING THE DISPENSER Figure Removing/Installing Shelf • The three buttons underneath the LED display dispense at pre-programmed quantities of 2QT, 3QT & 4QT as marked DISPENSING HOT WATER WARNING Water dispensed is very HOT Use proper container for holding hot water 2QT = quarts (1.9 liters) 3QT = quarts (2.8 liters) 4QT = quarts (3.8 liters) Place the proper water container for holding hot water on the shelf before dispensing NOTE: The dispense amounts can be adjusted if required See PROGRAMMING THE DISPENSER The shelf can be removed to dispense water into containers larger than the space between the dispenser and shelf Lift shelf up and off the mounting screwheads to remove shelf See Figure • The red button can be pressed any time after pressing one of the programmed dispense buttons to stop dispensing In addition, the red button can be pressed and held in to manually dispense water Water will continue to flow until the red button is released Dispensing is controlled by the four dispense buttons on the front of the unit See Figure 5 Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 OPERATION ERROR CODES There are four error codes that may show in the display: E1: Indicates that the display temperature is out of range or display temperature probe is malfunctioning '# E2: Indicates that the control temperature is out of range or control temperature probe is malfunctioning E3: Indicates that the low water probe has not been satisfied The heating elements are not yet submersed H2O: Indicates that the inlet water solenoid has been running continuously for an excessive period of time Check for problems with the water supply or internal water leak Adjustable from 75° - 195°F (82° - 91°C) in degree intervals Figure Setting Temperature Setpoint PROGRAMMING THE DISPENSER Changing Temperature Setpoint Turn the power switch to the OFF position and unplug the unit from the electrical outlet WARNING To avoid any injury, turn the power switch off at the fuse disconnect switch/circuit breaker or unplug the unit from the power source and allow to cool completely before performing any maintenance or cleaning Remove top red panel Move dipswitch to the left, (when facing the controls) to enter programming mode Dipswitch Panel A dipswitch panel is located on the back of the control board which is behind the front panel graphic overlay The switches have the following functions: Plug the unit into the proper electrical outlet and turn the power switch to ON The LED will display (temperature setpoint) This indicates the beginning of the programming sequence Press the RED manual dispense button and the display will now read the current temperature setpoint See Figure Switch is used to switch between operational (Run) mode and Programming mode Switch is used to change the temperature display from F° to C° Use the 2QT and 3QT buttons to adjust the temperature setpoint up or down Switch is used to select the type of operation, and must be switched to the right-hand position for the dispenser to operate When the desired setpoint is displayed, press the RED dispense button to save the change to memory Turn the power switch to OFF and unplug the unit from the electrical outlet Switch is not used Changing Temperature Display Turn the power switch to the OFF position and unplug the unit from the electrical outlet NOTE: If no buttons are pressed for a period of 15 seconds, the program will automatically jump to the end of the programming sequence, and the display will read END Remove top red panel Move dipswitch back to the operational (Run) mode Move dipswitch to the left, (when facing the controls) to change the display from Fahrenheit (F°) to Celsius (C°) Re-install top red panel Re-install top red panel Plug the unit into the proper electrical outlet and turn the power switch to ON Plug the unit into the proper electrical outlet and turn the power switch to ON Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine OPERATION Changing Dispense Time (Water quantity) Turn the power switch to the OFF position and unplug the unit from the electrical outlet Remove top red panel Move dipswitch to the left, (when facing the controls) to enter Programming mode Plug the unit into the proper electrical outlet and turn the power switch to ON The LED will display (temperature setpoint) This indicates the beginning of the programming sequence Adjustable from - 120 seconds in second intervals Press the RED manual dispense button to scroll to the desired dispenser button to be programmed See Figure Figure Setting Dispenser Time 2QT Dispenser Shown NOTE: Dispenser button = 2QT Dispenser button = 3QT Dispenser button = 4QT Use the 2QT and 3QT buttons to adjust the dispense time up or down When the desired dispense time is displayed, press the RED button to save the change to memory and to scroll to the next desired dispense button Repeat step or turn the power switch to OFF and unplug the unit from the electrical outlet Move dipswitch back to the operational (Run) mode Re-install top red panel 10.Plug the unit into the proper electrical outlet and turn the power switch to ON Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 MAINTENANCE GENERAL WARNING To avoid any injury, turn the power switch off at the fuse disconnect switch/circuit breaker or unplug the unit from the power source and allow to cool completely before performing any maintenance or cleaning De-liming Additive Fill Cup CLEANING DISPENSER EXTERIOR To preserve the finish of the Atmospheric Hot Water Dispenser, it is recommended that the exterior surfaces be wiped daily with a clean, damp cloth DRAINING THE DISPENSER It is recommended that the dispenser be drained prior to moving the unit and after performing the De-Liming the Dispenser Figure De-Liming the Unit WARNING To avoid any injury, turn the power off to the unit and allow to cool before draining NOTE: It is recommended that this procedure be performed when the dispenser will not be used for a period of time, such as at the end of the day Shut off the water supply to the unit With the unit at operating temperature of 195°F (91°C), turn the power switch OFF and drain gallons (11 liters) of water through the manual drain (see DRAINING THE DISPENSER) Turn the power switch to the OFF position and unplug the unit from the electrical outlet Connect drain hose to water outlet on underside of unit See Figure Replace the drained gallons (11 liters) with gallons (11 liters) of off-the-shelf vinegar Slowly pour the vinegar into the black fill cup on the upper side of the unit See Figure Place open end of drain hose in a bucket or open site drain, in a manner according to local plumbing codes Open the drain valve by placing the drain handle in the vertical position See Figure Turn the power switch ON and allow the unit to heat up to the operating temperature generally 195°F (91°C) Run the unit at this temperature for 1-2 hours After water is through draining, place the valve handle in the fully horizontal position to close the valve See Figure Dispense 1/2 quart (.4 liters) of solution through the dispensing port This exposes the port to the de-liming agent (Safely discard dispensed solution.) Turn on the water supply to the dispenser Plug the unit into the proper electrical outlet and turn the power switch to ON Turn power OFF to unit and allow de-liming agent to remain in unit for a minimum of hours (Preferably overnite.) DE-LIMING THE DISPENSER A mixture of off-the-shelf vinegar (5% vinegar solution) and water should be used to de-lime the Atmospheric Water Dispenser A minimum mixture of 25% off-the-shelf vinegar and 75% water is recommended to effectively de-lime the dispenser After the de-liming period, drain the solution from the tank (See DRAINING THE DISPENSER.) NOTE: The lime and mineral content of the supply water will determine how often this procedure must be performed Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine MAINTENANCE Refill the unit with water by following the START-UP procedure Continue to dispense water out of the unit until the discharge is clear and all de-liming solution has been removed and rinsed WARNING If service is required on this unit, contact your Authorized Hatco Service Agent, or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966 or international fax 414-671-3976 NOTE: Steps and may need to be repeated until all de-liming agent has been removed WARNING This product has no “user” serviceable parts To avoid damage to the unit or injury to personnel, use only Authorized Hatco Service Agents and Genuine Hatco Parts when service is required RESETTING THE HIGH TEMPERATURE SAFETY SWITCH The Atmospheric Water Dispenser is equipped with a manually resettable high limit safety switch that prevents the water temperature from getting dangerously high If the water inside the unit exceeds 200°F (93°C) the safety high limit switch will shut the unit off Setting the setpoint temperature over 195°F (91°C) may cause nuisance tripping of this safety switch Hatco does not recommend adjusting the setpoint temperature above 195°F (91°C) WARNING Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used Some aftermarket or generic replacement parts not have the characteristics that will allow them to operate safely in Hatco equipment It is essential to use Hatco Replacement Parts when repairing Hatco equipment Failure to use Hatco Replacement Parts may subject operators of the equipment to hazardous electrical voltage, resulting in electrical shock or burn To reset the safety high limit switch follow these steps: Turn the power switch OFF, unplug the unit from the power source and allow to cool completely before proceeding The high limit switch cannot be reset until the water temperature drops below 150° (66°C) Remove the front shelf and the six screws that hold the front panel in place, then remove the front panel The high limit safety switch is located on the water tank, near the left heating element (when facing controls) and the bottom of the tank To reset, press in the small red button on the switch until it clicks Reinstall the front panel and shelf NOTE: If the high limit safety continues to trip verify the setpoint is 195°F (91°C) or lower If the temperature setpoint is above 195°F (91°C) adjust the setpoint down to an acceptable level See PROGRAMMING THE DISPENSER for adjustment instructions Contact an Authorized Service Agent if the high limit safety continues to trip and the temperature setpoint is 195°F (91°C) or below Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 HATCO LIMITED WARRANTY THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing, SUCH WARRANTIES DO NOT COVER: Coated incandescent light bulbs, fluorescent lights, lamp warmer heat bulbs, glass components, Product failure in booster tank, fin tube heat exchanger, or other water heating equipment, caused by liming, sediment buildup, chemical attack or freezing, Product misuse, tampering or misapplication, improper installation or application of improper voltage PRODUCT WARRANTY Hatco warrants the products that it manufactures (the “Products”) to be free from defects in materials and workmanship, under normal use and service, for a period of one (1) year from the date of purchase when installed and maintained in accordance with Hatco’s written instructions or 18 months from the date of shipment from Hatco Buyer must establish the product’s purchase date by returning Hatco’s Warranty Registration Card or by other means satisfactory to Hatco in its sole discretion Hatco warrants the following Product components to be free from defects in materials and workmanship from the date of purchase (subject to the foregoing conditions) for the period(s) of time and on the conditions listed below: LIMITATION OF REMEDIES AND DAMAGES Hatco’s liability and Buyer’s exclusive remedy hereunder will be limited solely, at Hatco’s option, to repair or replacement by a Hatcoauthorized service agency (other than where Buyer is located outside of the United States, Canada, United Kingdom or Australia in which case Hatco’s liability and Buyer’s exclusive remedy hereunder will be limited solely to replacement of part under warranty) with respect to any claim made within the applicable warranty period referred to above Hatco reserves the right to accept or reject any such claim in whole or in part Hatco will not accept the return of any Product without prior written approval from Hatco, and all such approved returns shall be made at Buyer’s sole expense HATCO WILL NOT BE LIABLE, UNDER ANY CIRCUMSTANCES, FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR COSTS OR LOST PROFITS RESULTING FROM THE USE OF OR INABILITY TO USE THE PRODUCTS OR FROM THE PRODUCTS BEING INCORPORATED IN OR BECOMING A COMPONENT OF ANY OTHER PRODUCT OR GOODS a) One (1) Year Parts and Labor PLUS One (1) Additional Year Parts-Only Warranty: Toaster Elements (metal sheathed) Drawer Warmer Elements (metal sheathed) Drawer Warmer Drawer Rollers and Slides Food Warmer Elements (metal sheathed) Display Warmer Elements (metal sheathed air heating) Holding Cabinet Elements (metal sheathed air eating) b) One (1) Year Parts and Labor PLUS Four (4) Years Parts-Only Warranty on pro-rated terms that Hatco will explain at Buyer’s request: 3CS and FR Tanks c) One (1) Year Parts and Labor PLUS Nine (9) Years Parts-Only Warranty on: Electric Booster Heater Tanks Gas Booster Heater Tanks Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine 10 NOTES 11 Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 NOTES Form No AWDM-0704 Downloaded from www.Manualslib.com manuals search engine 12 NOTES 13 Downloaded from www.Manualslib.com manuals search engine Form No AWDM-0704 HATCO AUTHORIZED PARTS DISTRIBUTORS ALABAMA IOWA NEW YORK (continued) TENNESSEE Jones McLeod Appl Svc Birmingham 205-251-0159 Electric Motor Service Co Davenport 319-323-1823 Alpro Service Co Brooklyn Camp Electric Memphis ARIZONA Goodwin Tucker Group Des Moines 515-262-8308 Appliance Installation Buffalo 716-884-7425 KENTUCKY Northern Parts Dist Plattsburgh 518-563-3200 J.B Brady, Inc Syracuse Armstrong Repair Service Houston 713-666-7100 315-422-9271 NORTH CAROLINA Commercial Kitchen Repair Co San Antonio 210-735-2811 Authorized Appliance Charlotte 704-377-4501 San Antonio Rest Equip San Antonio 210-532-1660 OHIO UTAH Akron/Canton Comm Svc Inc Akron 330-753-6635 GCS Service Salt Lake City Certified Service Center Cincinnati 513-772-6600 VIRGINIA Auth Comm Food Equip Phoenix 602-234-2443 Byassee Equipment Co Phoenix 602-252-0402 GCS Service Louisville CALIFORNIA LOUISIANA 502-367-1788 714-379-7100 Chandlers Parts & Service Baton Rouge 225-272-6620 Chapman Appl Service San Diego 619-298-7106 Bana Comm Parts, Inc Shreveport 318-631-6550 P & D Appliance S San Francisco MARYLAND Industrial Electric Huntington Beach 650-635-1900 718-386-2515 901-527-7543 TEXAS Stove Parts Supply Fort Worth 817-831-0381 801-487-3653 COLORADO Electric Motor Service Baltimore 410-467-8080 Hawkins Commercial Appliance Englewood 303-781-5548 GCS Service Silver Spring DELAWARE MASSACHUSETTS Food Equipment Service Wilmington 302-996-9363 Ace Service Co., Inc Needham 781-449-4220 FLORIDA MICHIGAN Electrical Appl Repair Service Independence 216-459-8700 Whaley Foodservice Repair Jacksonville 904-725-7800 Restaurant Appl Service Seattle 206-524-8200 Commercial Kitchen Service Bay City 517-893-4561 E A Wichman Co Toledo WISCONSIN Universal Restaurant Services Miami 305-593-5488 Bildons Appliance Service Detroit 248-478-3320 OKLAHOMA A.S.C., Inc Madison 608-246-3160 Hagar Rest Service, Inc Oklahoma City 405-235-2184 A.S.C., Inc Milwaukee 414-543-6460 Nass Service Co., Inc Orlando 407-425-2681 B.G.S.I Pompano Beach 954-971-0456 Comm Appliance Service Tampa 813-663-0313 GEORGIA Adcox Service Co Atlanta 404-361-8010 Southeastern Rest Svc Norcross 770-446-6177 301-585-7550 Midwest Food Equip Service Grandville 616-261-2000 Commercial Parts and Service Columbus 614-221-0057 GCS Service Columbus MINNESOTA Krueger, Inc Oklahoma City GCS Service Minneapolis OREGON 612-546-4221 503-231-7171 BRITISH COLUMBIA 503-624-0890 Key Food Equipment Service Vancouver 604-433-4484 816-920-5999 Commercial Kitchen Services St Louis 314-890-0700 PENNSYLVANIA ONTARIO FAST Comm Appl Service Philadelphia 215-288-4800 R.G Henderson Ltd Toronto 416-422-5580 Choquette CKS Ottawa 613-739-8458 GCS Service Pittsburgh Anderson Electric Omaha K & D Service Co Harrisburg Midwest Elec Appl Service Elmhurst 630-279-8000 Cone’s Repair Service Moline 309-797-5323 INDIANA GCS Service Indianapolis 402-341-1414 NEVADA Burney’s Commercial Las Vegas 702-736-0006 Eichenauer Elec Service Decatur 217-429-4229 CANADA Ron’s Service, Inc Portland NEBRASKA 708-865-7278 405-528-8883 GCS Service Kansas City Burney’s Comm Service, Inc Honolulu 808-848-1466 Parts Town Lombard 703-866-3600 WASHINGTON MISSOURI HAWAII ILLINOIS 419-385-9121 757-855-4097 Daubers Springfield Bressie Electric Co Portland Kaemmerlen Parts & Service St Louis 314-535-2222 Food Equip Parts & Service Honolulu 808-847-4871 614-476-3225 Daubers Norfolk Hi Tech Commercial Service N Las Vegas 702-649-4616 NEW JERSEY 412-787-1970 717-236-9039 Elmer Schultz Services Philadelphia 215-627-5401 Electric Repair Co Reading 610-376-5444 QUÉBEC Choquette CKS Montreal 514-722-2000 Choquette CKS Québec City 418-681-3944 RHODE ISLAND Marshall Electric Co Providence 401-331-1163 Jay Hill Repair Fairfield 973-575-9145 SOUTH CAROLINA Service Plus Flanders 973-691-6300 Whaley Foodservice Repair W Columbia 803-791-4420 NEW YORK 317-545-9655 Acme American Repairs, Inc Brooklyn 718-456-6544 HATCO CORPORATION P.O Box 340500, Milwaukee, WI 53234-0500 U.S.A (800) 558-0607 (414) 671-6350 Parts & Service Fax (800) 690-2966 Int’l Fax (414) 671-3976 www.hatcocorp.com Printed in U.S.A July 2004 Downloaded from www.Manualslib.com manuals search engine Part No 07.04.356.00 Form No AWDM-0704 ... that will allow them to operate safely in Hatco equipment It is essential to use Hatco Replacement Parts when repairing Hatco equipment Failure to use Hatco Replacement Parts may subject operators... that will allow them to operate safely in Hatco equipment It is essential to use Hatco Replacement Parts when repairing Hatco equipment Failure to use Hatco Replacement Parts may subject operators... to the unit or injury to personnel, use only Authorized Hatco Service Agents and Genuine Hatco Parts when service is required Genuine Hatco Replacement Parts are specified to operate safely in

Ngày đăng: 13/03/2019, 19:32

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN