1. Trang chủ
  2. » Tất cả

ReadmeFAILenUS

8 8 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Cấu trúc

  • Industrial softwareSIMATIC Safety V14 readme

  • Legal information

  • Table of contents

  • 1 Security information

  • 2 Notes on use

  • 3 Editing devices and networks

    • 3.1 General notes on devices and networks

  • 4 Programming PLC

    • 4.1 General Notes on PLC Programming and on Acceptance

Nội dung

1 _ Security information _ Notes on use SIMATIC Industrial software SIMATIC Safety V14 readme Readme 09/2016 A5E32923676-AE _ Editing devices and networks _ Programming PLC Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol These notices shown below are graded according to the degree of danger DANGER indicates that death or severe personal injury will result if proper precautions are not taken WARNING indicates that death or severe personal injury may result if proper precautions are not taken CAUTION indicates that minor personal injury can result if proper precautions are not taken NOTICE indicates that property damage can result if proper precautions are not taken If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used, these must be recommended or approved by Siemens Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems The permissible ambient conditions must be complied with The information in the relevant documentation must be observed Trademarks All names identified by ® are registered trademarks of Siemens AG The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described Since variance cannot be precluded entirely, we cannot guarantee full consistency However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY A5E32923676-AE Ⓟ 09/2016 Subject to change Copyright © Siemens AG 2011 - 2016 All rights reserved Table of contents Security information Notes on use Editing devices and networks 3.1 General notes on devices and networks Programming PLC 4.1 General Notes on PLC Programming and on Acceptance .7 SIMATIC Safety V14 readme Readme, 09/2016, A5E32923676-AE Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept Siemens’ products and solutions only form one element of such a concept Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g use of firewalls and network segmentation) in place Additionally, Siemens’ guidance on appropriate security measures should be taken into account For more information about industrial security, please visit (http://www.siemens.com/industrialsecurity) Siemens’ products and solutions undergo continuous development to make them more secure Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under (http://www.siemens.com/industrialsecurity) SIMATIC Safety V14 readme Readme, 09/2016, A5E32923676-AE Notes on use Content Notes that could not be taken into account in the online help and the manual The manual as PDF file The "SIMATIC Safety - Configuring and Programming" manual was stored in the installation folder of STEP Professional or STEP Basic in the "Manuals" subfolder during installation of the STEP Safety optional package SIMATIC Safety V14 readme Readme, 09/2016, A5E32923676-AE Editing devices and networks 3.1 General notes on devices and networks Roaming User Profiles not supported You cannot use STEP Safety in a roaming user profile The software has only limited functionality under these circumstances Contact your domain administrator if you have a roaming user profile Installation of HSPs Make that all HSPs required in the project are installed before you work with the project Configuring phase shifting for the F-OB Assign phase shift parameters for an F-OB using the following formula: Phase shift < Max_Cyc - Cyclic interrupt time Assigning F-destination addresses to fail-safe modules with SIMATIC Safety When using an F-CPU S7-300/400, it is not possible to assign F-destination addresses to the fail-safe modules behind an IE/PB Link SIMATIC Safety V14 readme Readme, 09/2016, A5E32923676-AE Programming PLC 4.1 General Notes on PLC Programming and on Acceptance Content Notes that could not be taken into account in the online help and the manual What you need to observe with regard to the installation of STEP Safety? After the installation of STEP Safety, your safety program will be shown as inconsistent in the Safety Administration Editor Initiate compilation of the safety program You will obtain a consistent safety program as a result The collective F-signature of your safety program remains unchanged Online functions ● It is not possible to open F-blocks via the Lifelist with STEP Safety You have to have the corresponding project opened offline in order to use all of the online functions for F-blocks ● Use the Safety Administration Editor for the offline-online comparison if you wish to view the checksums of F-blocks Upgrading to STEP Safety V14 ● After upgrading a project that contains S7-300/400 F-CPUs, we recommend executing the command "Compile > Software (rebuild all blocks)" ● The name of the F-I/O is a component of the name of the associated F-I/O DB In earlier versions of STEP Safety, it was not always ensured that this component was identical to the name of the F-I/O This is corrected with the upgrade to STEP Safety V14 This does not change the functionality or the collective signature of your safety program However, since the names of the F-I/O DBs have changed, you should generate an upto-date safety summary after the upgrade and add it to your acceptance documents SIMATIC Safety V14 readme Readme, 09/2016, A5E32923676-AE Programming PLC 4.1 General Notes on PLC Programming and on Acceptance Supplement to the "Know-how protection" and "Reuse of F-blocks" sections S7-1200/1500 F-CPUs The following special features apply to STEP Safety V14: ● You cannot create a type in the project library or in a global library from a know-howprotected F-block Solution: Use the master copies or projects as delivery form ● When you call other user-defined blocks in a know-how protected F-block, use the option to sort the know-how protected F-block and the user-defined block it contains as group (folder) in the project tree The following rules apply: – The called blocks must be multi-instances – The called blocks should be know-how-protected If you wish to continue to use the know-how-protected blocks, store the group (folder) as master copy If you wish to continue to use the know-how-protected blocks in another F-CPU, also store the group (folder) as master copy Supplement to the "MOVE: Move value (STEP Safety V14)" section In the basic state, the instruction box contains an output (OUT1) The number of outputs can be expanded The inserted outputs are numbered in ascending order on the box During execution, the content of the operand at the IN input is transferred to all available outputs The instruction box cannot be expanded if operands with F-compliant PLC data types (UDT) are transferred Supplement to the "CTD: Count down (STEP Safety V14)" and CTUD: Count up and down (STEP Safety V14)" sections If you use the CTD or CTUD instruction with version 1.1 in a know-how-protected block, you must open the block by entering the password before compiling in order to change the version of the CTD or CTUD instruction to a version other than V1.1 The same applies if you want to change the version of the CTD or CTUD instruction from a version other than V1.1 to version V1.1 Compiling the safety program The collective F-signature is determined in STEP Safety V14 when you compile the safety program and shown in the Safety Administration Editor under "Code signature" The collective F-signature is valid but the safety program can still be inconsistent This is the case when the hardware configuration is not up-to-date (compiled) Compile the hardware configuration to obtain a consistent safety program The collective F-signature does not change as a result SIMATIC Safety V14 readme Readme, 09/2016, A5E32923676-AE

Ngày đăng: 04/01/2019, 12:20

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN