1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Calibration of CNC milling machine by direct metho

11 120 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 11
Dung lượng 631,15 KB

Nội dung

See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/252729837 Calibration of CNC milling machine by direct method Article in Proceedings of SPIE - The International Society for Optical Engineering · December 2008 DOI: 10.1117/12.807066 CITATION READS 254 2 authors, including: Wuyi Chen Beihang University (BUAA) 118 PUBLICATIONS 633 CITATIONS SEE PROFILE All content following this page was uploaded by Wuyi Chen on 21 May 2015 The user has requested enhancement of the downloaded file All in-text references underlined in blue are added to the original document and are linked to publications on ResearchGate, letting you access and read them immediately Calibration of CNC milling machine by direct method Abdul Wahid Khan*, Wuyi Chen ** School of Mechanical Engineering and Automation, Beihang University Beijing 100083, China ABSTRACT Calibration refers to the system of quantity value determination of instruments, equipments and test devices according to industrial requirement, based on metrological characteristics In present research critical parameter which affects the accuracy and product quality of a CNC milling machine, was investigated and quantified by using direct method These parameters consist of position dependent or position independent parameters, like linear displacement errors, angular errors of linear axes, straightness error of linear axes and squareness error between the axes Repeatability, lead screw and resolution error of the CNC milling machine were also quantified to provide additional information to the user, because in absence of this additional information a misconception persists causing a major contributor to the inaccuracy and quality of the product Parameters were measured and quantified by using a laser interferometer and artifacts as working standards under controlled environmental conditions on a manufacturing CNC milling machine Polynomial regression analyses were carried out for finding the coefficients to predict the errors at each and every desired position which is quite useful for compensation and enhancing the accuracy of a machine system Machine accuracy detailed chart was also made to assess and assure the accuracy, capability or for accuracy monitoring of the CNC milling machine Key words: Error characterization, Calibration, Laser interferometer, Measurement method, Quality control, Metrology INTRODUCTION Calibration is defined as set of operations which establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system, or values represented by a material measure or a reference material, and the corresponding values realized by standards [1] It determines the relation between the output of the machine tool, instrument or test device and the value of the input quantity, attribute or measurement standard Calibration is the only comprehensive indicator which depicts a detailed picture regarding accuracy of machine tools which is one of the most important indices to assess the quality and capability of machine tools Accuracy parameter significantly affects all criterion of machine performance including quick acting, energy efficiency, metal consumption, reliability and durability On basis of calibration results a qualification or capabilities are ascertained to permit the machine tool, for further processing of compatible accuracy requirement The results of calibration make possible either the assignment of values of measurand to the indications or the determination of corrections with respect to indications [2] Calibration of machine tools is important for both acceptance testing and error characterization and for compensation etc [3-7] Basically there are only three common methods reported [8] which are well known and in practice for calibration of machine tools The first method is direct or parametric method and quite popular for quantifying various error terms independently Second method is known as volumetric calibration method and able to quantify the error between actual and commanded motion at specific desired point in workspace of a machine tool It uses some sort of kinematic reference standards such as double ball bar, disk etc and mostly used for acceptance testing and for the periodic checks Third method is based on measuring an artifact or standard part, such as ball plate, cubic box, tetrahedron etc and known as artifact calibration method or hybrid calibration method This method is also applicable for acceptance testing and periodic checks The parametric method is the only well known method which is reliable and provide realistic information about elemental accuracy of machine tools and most popular and appreciated by the machine tool builders and the users for error characterization and error compensation So in current research authors implemented the parametric method on a CNC milling machine for error characterization in which 21 parametric position dependent and position independent errors of CNC milling machine were quantified and besides these the repeatability, resolution and lead screw errors were also assessed as an additional information Authors tried to pay attention to calibrate manufacturing machines which is rare attended before in manufacturing environment history * hanyiga@gmail.com ; **wychen@buaa.edu.cn 2008 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Applications, edited by Shenghua Ye, Guangjun Zhang, Jun Ni, Proc of SPIE Vol 7160 716010 · © 2009 SPIE · CCC code: 0277-786X/09/$18 · doi: 10.1117/12.807066 Proc of SPIE Vol 7160 716010-1 although calibration is very common in metrological machines and metrological machines calibrated periodically OVERVIEW OF MACHINE TOOLS ERRORS Errors in machine tools originate from various sources and causes degradation of machine tool accuracy whereas accuracy is the only main metrological characteristics of machine tools which can be defined as the closeness of the agreement between the results of a measurement and a true value of the measurand [1] As the closeness of agreement spread out the error enlarged and show the degradation of machine tool However degradation of accuracy means degradation of product quality For characterizing or improving the machine tool accuracy it is essential that one must familiar with the sources which seriously effect and originates errors 2.1 Errors and their sources in machine tools According to the nature of the machine tools errors can be divided into two main categories that are quasi-static and dynamic errors Quasi-static error which is the major sources of error in machine tools consists of geometric error, kinematic error, stiffness error and thermal error The quasi-static errors are considered as a major source of error and contribute as much as 70% of the total machine errors [9] Geometric error is introduced due to imperfection or imprecision of structural elements and components used in assemblies or subassembly level whereas kinematic error is introduced by the motion of the rigid bodies to reach the exact desired position Geometric and kinematic errors are considered as interrelated errors Stiffness error is introduced due to lack of stiffness of machine bodies or having some extent of elastic behavior under loading and unloading conditions Thermal errors are mainly the major cause of dimensional errors having a non linear behavior and due to its non linear behavior it is quite difficult to estimate exactly Dynamic errors originated from spindle motion, vibration affecting the machine structure and itself vibration in internal components of machine tools and controller errors fall in this category Besides these main errors there is some other errors including cutting force induced errors, tool wear errors and fixturing errors 2.2 Errors categorized on Position basis As quasi-static error contributes as a major source of error in a machine tool which can be minimized at its design stage and improvement of the system carried out through some preventive actions or compensation etc, so main concentration of the researcher is on this field in which errors can be quantified and avoided by taking preventive actions and improving the flaws at design stages and processing stage Abbaszadeh-Mir et al [10] classified the rigid body geometric errors in to two groups The first group was the position independent geometric errors which were also called link errors such as misalignments, angular offsets and position distance between rotary axes The second group was the position dependent geometric error parameters that varied with the position of the machine slides Position independent errors can be calculated by below given equation (1) E = 3(n − 2) (1) “E” represents the error and “n” represents the number of joints Whereas the total position dependent errors in a machine tool can be calculated by the formula given below E = 6n (2) “E” represents the error and “n” represents the number of joints TOPOLOGY OF CNC MILLING MACHINE AND ERRORS IDENTIFICATION A CNC milling machine as mentioned in figure-1 consists of three prismatic joints named as X, Y and Z slides oriented and move along the X, Y and Z global coordinate system respectively Y slide joins with the base of the CNC milling machine and X-slide which accommodates the workpiece rides on the Y-slide Z-slide directly joins with the base of Proc of SPIE Vol 7160 716010-2 CNC milling machine and move along the global Z-coordinate system while carrying the spindle motor which mounted on the Z-slide When the machine coordinate is set at reference zero position all slides reference coincide to zero and display X, Y and Z at zero position According to the equation (2) the machine has total 18 dependent errors whereas the total independent position errors which are calculated as per equation (1) are found Prismatic joints X, Y and Z slides fall in the category of rigid body system which has six degree of freedom in the space When a prismatic joint moves, it may have six degree of errors from aforesaid error causes 6-DOF errors in a prismatic joint are composed of the three along the axis X, Y, Z denoted by δ x , δ y , δ z and the three around the X, Y, Z axis called roll, pitch and yaw errors εx , εy , εz respectively It can be presented and observed by the coordinate frames by appointing the reference frame on the guide ways and appointing the moving frame on the slides The translational and rotational errors can be observed in the moving frame through the relative movement of reference frame elaborated in figure-2 and mentioned in Table-1 Fig Topology of CNC milling machine öz (x) Fig 6DOF errors in a prismatic joint Proc of SPIE Vol 7160 716010-3 Table-1 Error description in CNC milling machine S.No Error type Linear displacement errors Vertical straightness errors Horizontal straightness errors Roll angular errors Pitch angular errors Yaw angular errors Squareness errors Notation δx(x), δy(y), and δz(z) δy(x), δx(y), and δx(z) δz(x), δz(y), and δy(z) εx(x), εy(y), and εz(z) εy(x), εx(y), and εx(z) εz(x), εz(y), and εy(z) Sxy, Syz, Szx where, “δ” is the linear error, subscript is the error direction and the position coordinate is inside the parenthesis, “ε” is the angular error, subscript is the axis of rotation and the position coordinate is inside the parenthesis CALIBRATION THROUGH DIRECT METHOD Direct calibration method or error quantification is carried out at elemental basis and total positions dependent and position independent parameters can be measured and quantified individually This approach addresses the problem of computing deformation of machine members individually because the errors meterage of these parameters is usually impossible to analyze precisely by using some other techniques or methodology and quantification of elemental errors is the only possible solution which helps out to find the genuine major source, causes and their contribution in accuracy of machine tool In direct calibration technique, the structure of the machine is considered as a kinematical model and is then analyzed using the rigid body kinematics so each error can be measured through conventional or by using available modern equipment such as laser interferometer, its accessories and electronic level etc as described by Weck and Bibring [11] and by Sarotori and Zhang [12] Table-2 lists suitable methodology choice Similar measurement guide line and help are available in some standards documents like ASME B.89.1 and ISO10360 standards [13, 14] Direct method is considered quite useful for error elimination, minimization through adjustment or compensation The main advantage of this method is that it presents the direct verification and evidences of mechanical accuracy of a machine tool or its prismatic joints and considered as an authentic method to provide error diagnosis or compensation Table-2 Measuring methods for determining parametric errors of CMMs Errors Positional Errors Straightness error Pitch and yaw errors Roll Errors Squareness errors Measurement Equipment or Methodology Laser interferometer, Step gauge, and Gauge blocks, end bars, ball arrays Straightness interferometer, Mechanical and optical straight edge, Alignment telescope with target, Alignment laser Displacement indicator or sensors, taut wire etc Differential interferometer, Mechanical and Electronic level, Autocollimator, Measurement of positional error along lines with different Abbe’s offset Angular laser interferometer Electronic levels, Reference Flat, Measurement of straightness errors of two parallel lines Optical and Mechanical Squareness standard, Length standard inclined under defined angles Diagonal measurements Proc of SPIE Vol 7160 716010-4 CALIBRATION OF CNC MILLING MACHINE BY USING DIRECT METHOD Calibration of a CNC milling machine (model XK7132) was carried out by using direct calibration method in which 21 parametric errors were measured directly The CNC milling machine was equipped with a Fanuc controller The stroke ranges were X=500mm, Y= 300mm and Z=350mm with resolution of 1µm, position accuracy 10µm and repeatability 7µm For direct calibration a laser interferometer of Renishaw ML-10 along with optics and accessories was adopted as a work standard, which was featured with HeNe laser beam with nominal wave length 0.633 µm (in vacuum), and the long term wavelength stability was better than 0.1ppm EC-10 environmental compensation unit for air temperature and air humidity compensation, and interfacing card along with data logging and evaluating software were also used Experiment was carried out under controlled environmental conditions to minimize the effects of random errors and to get the reliable results since the measurement is sensitive by operating temperature and its gradient Material temperature sensors and air temperature sensor were mounted to avoid temperature effect on measurement process Three prismatic joints X, Y and Z slides of the machine were calibrated as shown in figure-3 and in figure-4 -I Fig Straightness measurement by using laser interferometer Fig Displacement error measurement through laser interferometer Proc of SPIE Vol 7160 716010-5 Laser interferometer was used as per standard operating procedure and available guide lines mentioned in the operating instruction manual Instrument was preheated according the instructions and tried to shorten the distance between laser head and laser interferometer so that measuring errors could be minimized Optics was aligned in good manners and measurement was taken when properly aligned and more than 95% signal strength was displayed on screen over the entire axis travel during the measurement because the better alignment prevented dead path and cosine errors To obtain accurate and precise results the laser interferometer results were corrected for air temperature, air humidity and air pressure to prevent thermal shock erroneous effect on wavelength of laser beam Linear displacement accuracy, straightness error and pitch and yaw errors were measured in X, Y, Z direction by using the Laser interferometer Five ascending and descending readings were taken by using sequential displacement method Remaining errors were measured by using artifacts such as squareness measured through standard granite square by using reversal method, see figure-5 Roll can be measured through electronic level For measuring the squareness error standard granite square in conjunction with sensors was used as Mechanical Square It was placed in an axial plane approximately aligned with two axial directions Squareness measurement was carried out by using reversal method as mentioned as in figure-3 The 21 parametric errors of CNC milling machine including displacement errors, straightness errors, angular errors and squareness errors were measured by the aforesaid methods and results are shown through graph in figure 6-12 Resolution of the CNC milling machine, repeatability and lead screw errors were also measured Resolution results were shown through figure-13 and lead screw error was exhibited through figure-14 α α Fig.5 Measurement by reversal method (Red dot show the measuring sensor and colored lines indicates the measurement sides) Displace me nt Vs Translational Error Displace me nt Vs Straightne ss Error along X-Axis 50 60 40 20 - 20 30 60 90 120 150 180 210 240 270 300 - 40 δ y( Y) 40 30 20 10 0 Displace me nt (mm) δ x( X) Error (micron) Error (micron) 80 40 80 120 160 200 240 280 Di spl acement ( mm) δ z( Z) Fig Displacement Vs Translational Error δ y( X) δ z( X) Fig.7 Displacement Vs Straightness Error X-direction Proc of SPIE Vol 7160 716010-6 Displace me nt Vs Straightne ss Error along Z-Axis 300 Error (micron) Error (micron) Dispalce me nt Vs Straightne ss Error along YAxis 200 100 0 20 40 60 80 100 120 140 160 180 200 Displace me nt (mm) δ x( Y) 30 60 90 120 150 180 210 240 δ y( Z) Fig.9 Displacement Vs Straightness Error Z direction Displace me nt Vs Angular Errors along Y-Axis Error (rad) 12 15 18 21 24 27 30 90 60 30 0 - 50 δ x( Z) Error (rad) δ z( Y) Displace me nt Vs Angular Errors along X-Axis - 50 Displace me nt (mm) Fig Displacement Vs Straightness Error Y-direction - 100 Displace me nt (mm) ε y(X) - - ε x(X) 30 60 90 ε x(Y) Fig 10 Displacement Vs Angular Error in X-direction 180 35 25 15 05 30 ε y(Y) ε z(Y) Fig.11 Displacement Vs Angular Error in Y-direction Displace me nt Vs Angular Errors along Z-Axis Error (rad) 150 Dispalce me nt (mm) ε z(X) - 05 - 120 60 90 120 150 180 210 240 Displace me nt (mm) ε x(Z) ε y(Z) ε z(Z) Fig.12 Displacement Vs Angular Error in Z-direction Proc of SPIE Vol 7160 716010-7 rim - All Data Plot: RESOLUTION X-O.O1 -0225-400.RTL ALL tATA PWI' 3.5 a 2.5 C IJ 0.5 11 Dta F1t -0Line'00' 0.002 0.003 0.004 0.005 0.007 0.006 T aii11i) Macbina Serial Nc at ion: Date1135 Feb 25 2008 ename: RESOLUTION X-0 irect ional Fig 13 Resolution results All Data Plot: PITCH-X-SCREW-1 8-06.RTL LJ FT Fiø1' 0 .1 2 .3 Plot Serial No: 10 f ta Machine: i Date:16:02 Feb 23 2008 By: 12 TJtt (nilliurt) 18 : Location: °i lenae PTICM-X-SCREWBid ireot ional Fig 14 Lead Screw errors MEASUREMENT RESULTS AND DISCUSSION Three prismatic joints X, Y and Z slides of the CNC milling machine was calibrated and quantified by using the laser interferometer along with its optics and standard accessories and by using standard artifacts The specification are already discussed in this paper however these joints were measured a little less to their effective ranges to get the true pictures of errors and to avoid the backlash etc X-prismatic joint was measured in the range of 300 mm; Y-Prismatic joint was measured in the range of 200mm whereas Z-Prismatic joint was measured up to 250 mm of its working range Measurements were taken under controlled environment and in a cold state temperature gradient compensation was also Proc of SPIE Vol 7160 716010-8 made in the observed results This machine was in use from last eight years and it was not calibrated so that its accuracy was a big question To ensure its accuracy and reliability calibration process was carried out for its error mapping Large errors were observed in the translation, horizontal and vertical straightness of each prismatic joint whereas the pitch, roll and yaw was observed very small Among the prismatic joints the mostly biggest errors were observed in horizontal straightness of X-Prismatic joint and similar vertical straightness observed high in Y-Prismatic joint due to joint excessive usage Detailed results against three prismatic joints and error mapping graphs were plotted to predict the errors at each and every desired position which is quite useful for compensation and enhancing the accuracy of a machine system Resolution of CNC milling machine, repeatability and lead screw errors were also measured to provide additional information to the user so that user must be well informed and aware about the machine tool accuracy Machine accuracy detailed chart was also made to assess and assure the accuracy, capability or for accuracy monitoring of the CNC milling machine to give the quick out look of errors in prismatic joints attached as Appendix-A at the end of this paper SUMMARY AND CONCLUSION In this paper an attempt has been made by the authors to calibrate the CNC milling machine by implementing the direct method for error quantification of 21 position dependent and position independent parameters This method was quite reliable, authentic and simple for measuring the parametric errors Direct measuring method is a well established methodology in which a laser interferometer mostly used as a metrology tool for measurement of positioning errors, straightness errors and squareness error with high accuracy and reliability The only disadvantage of this method was that it took a long time for the error measurement and error analysis But this disadvantage is nothing in comparison of its reliable and authenticated results on which adjustment and compensation of the machine based for maintaining its accuracy It is extremely helpful for the machine tool builders and the machine tool users Machine resolution was not the same as claimed by the manufacturer due to its controller lead and lag movement Repeatability was found unsatisfactory and error in lead screw was also observed which need compensation REFERENCES 10 11 12 13 14 International Vocabulary of Basic and General Terms in Metrology, BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, OIML, 1993 Placko Dominique, Metrology in Industry: The key for quality Edited by French college of Metrology pp.128, 2006, R Hocken, “Machine tool Accuracy,” Technol machine tools, l5 Lawrence Livermore National Laboratory, University of California, Report of the machine tool task force , UGRL-52960-5, pp 1-85 (1980) J Tlusty, “Testing of accuracy of machine tools”, Report No UGRL-52960-Supp 1, 1980 G Zhang et al "Error compensation of coordinate measuring machines,” Ann CIRP, 34(1), (1985) R Hocken et al “Three dimensional metrology” Ann CIRP 26(2), (1977) A Donmez et al., “A general methodology for machine tool accuracy enhancement by error compensation,” Prec Engg (4), (1986) G Zhang, R Ouyang, B Lu, R Hocken, R Veale, A Donmez, “ A displacement method for machine geometry calibration,” Ann CIRP 37(1), (1988) J B Bryan, Ann CIRP 39(2) 645-656, (1990) Y Abbaszadeh-Mir., J.R R Mayer, G Cloutier, C Fortin, "Theory and simulation for the identification of the link geometric errors for a five-axis machine tool using a telescoping magnetic ball bar," Int J Prod Res 40 (18), 4781-4791 (2002) M Weck, and H Bibring, Handbook of Machine tools: Metrological analysis and performance tests, Volume 4, John Willey and sons, 1984 S Sarotori, and G.X Zhang, “Geometric error measurement and compensation of machines” Ann CIRP 44(2), 599609 (1995) “Methods for Performance Evaluation of coordinate measuring machines,” ANSI / ASME B89.1.12M-1990 by the American Society of Mechanical Engineering, 1990 ISO 10360: 2000, Geometrical Product Specifications (GPS) Acceptance and reverification tests for coordinate measuring machines, an International organization for standardization, 2002 Proc of SPIE Vol 7160 716010-9 Appendix-A: CNC machine tool accuracy chart S.No Error type Linear displacement errors Vertical straightness errors Horizontal straightness errors Roll angular errors Pitch angular errors Yaw angular errors Squareness errors Repeatability Resolution Error 10 Lead screw pitch error Notation Quantified Max eror δx(x) δy(y) δz(z) δy(x) δx(y) δx(z) δz(x) δz(y) δy(z) εx(x) εy(y) εz(z) εy(x) εx(y) εx(z) εz(x) εz(y) εy(z) Sxy Syz Szx X slide Y slide Z slide X slide Y slide Z slide X , Y, and Z lead screw -10.5805 ~ -33.3935 µm -4.8702 ~ -12.0613 µm -0.0085 ~ -0.0683 µm 12.4833 ~ 44.9643 µm 21.504 ~ 44.7607 µm -2.1882 ~ -16.8187 µm 6.3403 ~ 19.1099 µm 85.9738 ~ 201.4288 µm 8.599 ~ 68.7925 µm -0.0471 ~ -0.01696 rad 0.016 ~ 0.0351 rad -0.0085 ~ -0.0683 rad -0.0761 ~ -0.1855 rad 0.5652 ~ 1.3997 rad 0.0437 ~ 0.03493 rad 0.0461 ~ 0.1662 rad -0.1273 ~ -0.3152 rad 0.0035 ~ 0.0587 rad -1.0369 degree -0.0055 degree -0.0055 degree 4.607 µm 18.156 µm 11.051 µm -0.1 ~3.4 µm 0.1 ~ µm -0.2 ~2 µm Proc of SPIE Vol 7160 716010-10 View publication stats ~ 4.322 µm ... Proc of SPIE Vol 7160 716010-4 CALIBRATION OF CNC MILLING MACHINE BY USING DIRECT METHOD Calibration of a CNC milling machine (model XK7132) was carried out by using direct calibration method... the base of the CNC milling machine and X-slide which accommodates the workpiece rides on the Y-slide Z-slide directly joins with the base of Proc of SPIE Vol 7160 716010-2 CNC milling machine. . .Calibration of CNC milling machine by direct method Abdul Wahid Khan*, Wuyi Chen ** School of Mechanical Engineering and Automation, Beihang University Beijing 100083, China ABSTRACT Calibration

Ngày đăng: 31/12/2018, 11:59

TỪ KHÓA LIÊN QUAN