1. Trang chủ
  2. » Ngoại Ngữ

AS NZS 2293 2 1995 amdt 1 1998 emergency evacuation lighting

2 136 1

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Cấu trúc

  • AS/NZS 2293.2-1995 (Amdt 1) Emergency evacuation lighting for buildings - Inspection and maintenance

Nội dung

Title AS/NZS 2293.2-1995/Amdt 1-1998 Emergency evacuation lighting for buildings Inspection and maintenance Licensee Licensed to LUU MINH LUAN on 25 Feb 2002 Conditions of use This is a licensed electronic copy of a document where copyright is owned or managed by Standards Australia International Your licence is a single user licence and the document may not be stored, transferred or otherwise distributed on a network You may also make one paper copy of this document if required Web Check-up AS / NZS 2293.2/Amdt 1/1998-05-05 STANDARDS AUSTRALIA / STANDARDS NEW ZEALAND Amendment No to AS / NZS 2293.2:1995 Emergency evacuation lighting for buildings Part 2: Inspection and maintenance REVISED TEXT The 1995 edition of AS / NZS 2293.2 is amended as follows; the amendments should be inserted in the appropriate places Licensed to LUU MINH LUAN on 25 Feb 2002 Single user licence only Storage, distribution or use on network prohibited SUMMARY : This Amendment applies to Clauses 1.4.2, 3.1 and 3.4 Published on May 1998 Approved for publication in New Zealand on behalf of the Standards Council of New Zealand on 27 February 1998 AMDT No MAY 1998 AMDT No MAY 1998 AMDT No MAY 1998 Page Clause 1.4.2 In the last line, delete ‘inspecting’ and replace with ‘regulatory’ Page 10 Clause 3.1 Add a new sentence at the end of the second paragraph, as follows: Details of any corrective actions taken shall be recorded in accordance with Clause 1.4.2 Page 11 Clause 3.4 Delete the existing Clause and replace with the following: 3.4 BATTERY REPLACEMENT Whenever the batteries of emergency luminaires and exit signs are replaced for any reason, such replacements shall be made in accordance with the following: (a) Where more than one cell is utilized, the complete battery pack shall be replaced (b) Replacement batteries shall be of the same type and ampere-hour capacity (c) A discharge test shall be conducted in accordance with Clause 3.2.2 except that the test shall be continued for 1.33 times the required in-service duration ISBN 7337 1915 .. .AS / NZS 2293.2 /Amdt 1/1998-05-05 STANDARDS AUSTRALIA / STANDARDS NEW ZEALAND Amendment No to AS / NZS 2293.2:1995 Emergency evacuation lighting for buildings Part... the Standards Council of New Zealand on 27 February 1998 AMDT No MAY 1998 AMDT No MAY 1998 AMDT No MAY 1998 Page Clause 1.4.2 In the last line, delete ‘inspecting’ and replace with ‘regulatory’... for buildings Part 2: Inspection and maintenance REVISED TEXT The 1995 edition of AS / NZS 2293.2 is amended as follows; the amendments should be inserted in the appropriate places Licensed to

Ngày đăng: 08/08/2017, 04:32