FX2 integration system construction guide

12 180 0
FX2 integration system construction guide

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

会社名入力 savic-net FX Integration System Construction Guide 日付入力 Copyright  2008 Yamatake Corporation All Rights Reserved Contents Current available communication protocols with FX2 Communication protocol checklist for each manufacture Selection guide of communication protocols Special remarks of BACnet system Case study of BACnet Special remarks of Modbus system Case study of Modbus Copyright  2008 Yamatake Corporation All Rights Reserved Current available communication protocols with FX2 OA network FX IBMS SM S Client PC Intranet Internet Alarm Management Maintenance Management Help Desk Facility Booking Billing BACnet IP FX BEMS FX BMS EDS SMS Building Wide IT Network Infrastructure (Ethernet, 100Mbps) FX SEC DSS SDS IDS BMS Network (Ethernet, 100Mbps) ACC SCS Infilex IP type (DDC) Infilex (DDC) BACnet IP Modbus TCP Modbus RTU Modbus Device CCTV System Fire Alarm System Lighting Public Address Car Park System System System Lift/Escalator System Sub systems LonTalk Modbus TCP Modbus RTU Copyright  2008 Yamatake Corporation All Rights Reserved Communication protocol checklist for each manufacture Equipments Manufactures BACnet IP Communication Protocols BACnet Modbus Modbus MS/TP TCP RTU LON OPC CNA' Quantum Carrier Chiller TRANE YORK VRV DAIKIN Lighting Panasonic 産電 Power LG産電 Schneider Monitoring CIRCUTOR GE Janitza Power Meter M-System Mitsubishi SATEC Schneider GE PLC Mitsubishi Edwards GST(China) Fire Alarm NOHMI Notifier Simplex Public Address TOA Car Park Lift / Escalator FA System TOP Server IBMS Installed Possible, but not installed Need to discuss Impossible Copyright  2008 Yamatake Corporation All Rights Reserved Selection guide of communication protocols A) Communication protocol that Yamatake has already installed to an actual project is our first priority B) Our priorities in order are as follows when you’re going to communicate with first manufactures or products for Yamatake C) Modbus BACnet IP LON Let us know if OPC Server / OPC Client is required for your projects BSC is still considering to use 3rd party software for OPC Copyright  2008 Yamatake Corporation All Rights Reserved Special remarks of BACnet system FX2 can only use BACnet IP Promote Modbus or LON instead of BACnet if other BACnet protocols like BACnet Ethernet, BACnet MS/TP, etc are required Get a Protocol Implementation Conformance Statement (PICS) of the product on the other end of the communication as soon as possible and confirm their BACnet communication specifications like the protocol revision, network type and object types, etc Get the object list on the other end of the communication for our system engineering For the Yamatake HOST system, note as below a Estimate one or more SCS for the exclusive use of BACnet processing when FX2 has trending function or time program for other manufacturer’s products b Estimate SCOL Management function (BSY45310Z0502) when FX2 has trending function for other manufacturer’s objects FX2 needs SCOL program (analog copy output) to convert SCS external data of manufacturer’s objects to dummy points Copyright  2008 Yamatake Corporation All Rights Reserved Case study of BACnet (NOHMI) ・Objects reading / writing ・Alarm event sending ・Device monitoring Client PC < System name > Integlex fire alarm system B-OWS (MIS) < Protocol revision > ANSI/ASHRAE 135-2004 < Information type and objects> Fire representative information (BV) BACnet IP Fir alarm status (BI) B-BC (SCS) B-BC Exhaust-gas protection equipments running status (MI) Exhaust-gas protection control status (MO) Device information (Device) Notification-Class < Function > Fire Alarm System Fire alarm monitoring Copyright  2008 Yamatake Corporation All Rights Reserved Case study of BACnet (TRANE) ・Objects reading / writing ・Alarm scan (every min.) ・Device monitoring Client PC < System name > Tracer Summit B-OWS (MIS) < Protocol revision > ANSI/ASHRAE 135-1995 < Objects > AI/AO BACnet IP BI/BO B-BC (SCS) B-AAC (BCU) Device < Function > On / Off Status monitoring Failure monitoring Chiller Plant Control System Analog measurement Analog setting Copyright  2008 Yamatake Corporation All Rights Reserved Case study of BACnet (DAIKIN) Client PC B-OWS (MIS) ・Objects reading / writing ・Alarm scan (every min.) ・Device monitoring BACnet IP B-ASC (BACnet Gateway) B-BC D-BACS < Protocol revision > ANSI/ASHRAE 135-2004 < Objects > Accumulator AI/AO/AV BI/BO/BV Device MI/MO Notification-Class < Function > (Exclusive SCS for BACnet) ・External data collection (for trending) ・Time program < System name > Status / alarm monitoring Time program Event program Analog measurement / setting Trending VRV System Copyright  2008 Yamatake Corporation All Rights Reserved Special remarks of Modbus system FX2 can only use Modbus RTU and Modbus TCP Modbus ASCII and Modbus Plus cannot be supported with FX2 Get Modbus communication specifications of the product on the other end of the communication as soon as possible and confirm the possibility of communication with FX2 Create a Modbus Device chart for the Modbus engineering at first FX2 logically uses a Modbus device as a NC-bus controller So one Modbus devices has 99 points in maximum Add one more Modbus device in case of using over 100 points per Modbus device The latest recommended Modbus Media Converter is MOXA MB3170 http://www.moxa.com/product/MGate_MB3170_3270.htm Copyright  2008 Yamatake Corporation All Rights Reserved 10 Case study of Modbus (Power Meter) Client PC < Function > MIS Metering Current Modbus TCP BACnet IP Voltage Power SCS with Modbus Modbus Gateway Power Factor Frequency etc Modbus RTU Power Meter Copyright  2008 Yamatake Corporation All Rights Reserved 11 Case study of Modbus (Panasonic) Client PC < System name > MIS FULL-2WAY system Modbus TCP < Function > Individual Load Control BACnet IP SCS with Modbus Modbus Gateway OPIU (Modbus_IFU) One OPIU can manage 256 circuits But maximum 99 points per controller for SCS makes a priority Group Control Pattern Control Modbus RTU Dimmer Load Control System Status Monitor Lighting Control System Copyright  2008 Yamatake Corporation All Rights Reserved 12 ... IP Modbus TCP Modbus RTU Modbus Device CCTV System Fire Alarm System Lighting Public Address Car Park System System System Lift/Escalator System Sub systems LonTalk Modbus TCP Modbus RTU Copyright... with FX2 Communication protocol checklist for each manufacture Selection guide of communication protocols Special remarks of BACnet system Case study of BACnet Special remarks of Modbus system. .. the communication for our system engineering For the Yamatake HOST system, note as below a Estimate one or more SCS for the exclusive use of BACnet processing when FX2 has trending function or

Ngày đăng: 08/08/2017, 03:34

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan