  • SJ300/L300P SERIES SERVICE MANUAL (NBS611CX)

    • REVISION HISTORY Table

    • Table of contents

      • 1.Investigation of the inverter

        • 1.1 Specification label (Model name,Manufacturingnumber;MFG)

          • 1.1.1 Model name

          • 1.1.2 MFG number

        • 1.2 Inverter specificaution

          • 1.2.1 SJ300

          • 1.2.2 L300P

      • 2.TROUBLE SHOOTING

        • 2.1 Inverter trip contents,remedy,advice

        • 2.2 Option error

          • 2.2.1 Feed-back board (SJ-FB)

          • 2.2.2 Digital-input option board (SJ-DG)

          • 2.2.3 Device-Net option board (SJ-DN)

        • 2.3 Check of the trip monitor contens

        • 2.4 Check of the warning monitor contents

        • 2.5 Return to an initialization setup (Factory-shipment state)

      • 3.Debug Mode

        • 3.1 Monitor mode

        • 3.2 Function mode

        • 3.3 A setup of an inverter

        • 3.3.1 Setting procedure

        • 3.3.2 Initial cofiguration completion check pocedure

      • 4.The check of control power supply voltage and control signal

        • 4.1 Control power supply

        • 4.2 Control signal

      • 5.Maintenance and Inspection

        • 5.1 Maintenance and Inspection

          • 5.1.1 Daily inspection

          • 5.1.2 Cleaning

          • 5.1.3 Periodical inspection

        • 5.2 Dayly and annual maintenance

        • 5.3 Megger test

        • 5.4 Withstand voltage test

        • 5.5 How to check inverter and conveter portion

        • 5.6 Parts replacement

        • 5.7 Unit replacement

      • Appendix

        • Internal block diagram No. sheet

        • Internal block diagram

        • Circuit diagram

          • SJ300-004-007LF circuit Diagram

          • SJ300-015-055LF circuit diagram

          • SJ300-075,110LF/L300P-110,150LF circuit diagram

          • SJ300-150-220LF/L300P-185-300LF circuit diagram

          • SJ300-300LF/L300P-370LF circuit diagram

          • SJ300-370,450LF/L300P-450,550LF circuit diagram

          • SJ300-550LF/L300P-750LF circuit diagram

          • SJ300-007HF circuit diagram

          • SJ300-015-055HF circuit diagram

          • SJ300-075,110HF/L300P-110,150HF circuit diagram

          • SJ300-150-200HF/L300P-185-300HF circuit diagram

          • SJ300-300HF/L300P-370HF circuit diagram

          • SJ300-370-550HF/L300P-450-750HF circuit diagram

          • SJ300-750-1320HF/L300P-900-1320HF circuit diagram

        • Structure figure

          • SJ300-004LF/007LF,HF structure figure

          • SJ300-015-055LF structure figure

          • SJ300-075,110LF,HF/L300P110,150LF,HF structure figure

          • SJ300-150LF/L300P-185LF structure figure

          • SJ300-185LF/L300P-220LF structure figure

          • SJ300-220LF/L300P-300LF structure figure

          • SJ300-300LF/L300P-370LF structure figure

          • SJ300-370LF/L300P-450LF structure figure

          • SJ300-450LF/L300P-550LF structure figure

          • SJ300-550LF/L300P-750LF structure figure

          • SJ300-015-055HF structure figure

          • SJ300-150-220HF/L300P-185-300HF structure figure

          • SJ300-300HF/L300P-370HF structure figure

          • SJ300-370HF/L300P-450HF structure figure

          • SJ300-450HF/L300P-550HF structure figure

          • SJ300-550HF/L300P-750HF structure figure

          • SJ300-750,900HF/L300P-900,1100HF structure figure

          • SJ300-1100,1320HF/L300P-1320HF structure figure

        • Service parts list

          • 1.DC Bus capacitor

          • 8.Main circuit terminal

          • 13.IGBT Module

          • 14.Thyristor Module

          • 15.Diode Module

          • 19-2 Front cover

          • 19-3 Terminal cover

          • 19-5 Spacer cover

          • 19-6Cooling fan attachment board

          • 19-7 DC Bus capacitor attachment block

          • 19-11 Main body cover

          • 21 Cooling fan

          • 60 DC Bus capacitor PCB

          • 61 Logic PCB

          • 62 Control circuit terminals PCB

          • 63 R0-T0 PCB

          • 64 Main PCB (with Main body case)

          • 65 CT/Snubber PCB

          • 66 DM PCB

          • 67 Power source PCB

          • 68 OPE-S(R)

          • 69 Balance Resistor

          • 70 Snubber capacitor

          • 71 Snubber capacitor

          • 72 Snubber capacitor

          • 73 Snubber capacitor

          • 75 FFC

          • 76 Digital operator connection plug

          • 79 Snubber resistor

          • 80 Current Limiting resistor

          • 81 Wiring blind cover

          • 86 Thermistor

          • 95 Drive PCB

          • 96 GA PCB

          • etc.

Nội dung

HITACHI INVERTER SJ300 / L300P SERIES SERVICE MANUAL After reading this manual , keep it hand for future reference HITACHI NBS611CX Revision History Table No Revision Contents The Date of Issue Operation Manual No Japanese font was removed Nov 2000 NBS611BX The specification of the capacity 75-132kW and more was added Mar 2001 NBS611CX Table of contents Investigation of the inverter 1.1 Specification label(Model name , Manufacturing number ; MFG) 1.1.1 Model name ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1-1 1.1.2 MFG number ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1-1 1.2 Inverter specification 1.2.1 SJ300 ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1-2 1.2.2 L300P ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1-10 Trouble shooting 2.1 INV trip contents , remedy , advice ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2-1 2.2 Option error 2.2.1 Feed-back board (SJ-FB) ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2-3 2.2.2 Digital-input option board (SJ-DG)・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2-3 2.2.3 Device-Net option board (SJ-DN)・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2-3 2.3 Check of the trip monitor contents ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2-4 2.4 Confirmation of the warning monitor contents ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2-5 2.5 Return to an initialization setup (Factory-shipment state) ・・・・・・・・・・・・・・・・・・・・・・・ 2-6 Debug mode 3.1 Monitor mode ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3-1 3.2 Function mode・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3-2 3.3 Parameter settings for inverter ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3-3 The check of control power supply voltage and a control signal 4.1 Control power supply voltage ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4-1 4.2 Control signal ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4-1 Maintenance and Inspection 5.1 Maintenance and Inspection 5.1.1 Daily inspection ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-1 5.1.2 Cleaning ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-1 5.1.3 Periodical inspection ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-1 5.2 Daily and annual maintenance ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-2 5.3 Megger test ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-3 5.4 Withstand voltage test ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-3 5.5 How to check inverter , converter , BR and Thyristor portion ・・・・・・・・・・・・・・・・・・・・ 5-4 5.6 Parts replacement ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-5 5.7Unit replacement ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5-8 Appendix Circuit Diagram Internal block diagram Structure figure Investigation of the inverter 1.1 Specification label (Model name, Manufacturing number ; MFG) • There are specification label attached to the inverter as shown in Fig 1-1 Specification label Fig 1-1 Specification label location • Please confirm the model name and MFG number from the specification label as follows Model name Applicable motor Input ratings Output ratings MFG number Fig 1-2 contents of specification label 1.1.1 Model name SJ300-055 H F (R) R : with POT meter F : with digital operator L : φ 200V class H : φ 400V class Applicable motor (055 : 5.5kW) Model name 1.1.2 MFG number 94 A T12345 0001 Serial No (0001 ~ 9999) Year of production (9 : 1999) Production No REV No.(1 character or characters) Production year & month (94 : 1999 / April) 1-1 1.2 Inverter specification (Note1) 1.2.1 SJ300 Monitor Mode Display code d001 d002 d003 d004 SJ300 monitor or data range (digital operator) Function name Output frequency monitor Output current monitor Operation direction monitor PID feedback monitor 0.00-99.99/100.0-400.0(Hz) - 0.0-999.9(A) - F(forward)/o(stop)/r(reverse) - 0.00-99.99/100.0-999.9/1000 – 9999 / 1000-9999/ 100- 999 (10000-99900) - (Example) FW, terminal 7,2, 1: ON Terminal 8,6,5,4,3:OFF ON FW d005 Initial data Intelligent input terminal monitor - OFF d006 (Example) Terminal 12,11:ON AL, 15,14,13:OFF ON Intelligent output terminal monitor - OFF AL 15 14 13 12 0.00-99.99/100.0-999.9/1000 – 9999 / d007 Frequency conversion monitor 1000-3996 d012 torque monitor -300.-+300.% Output voltage d013 0.0-600.0 V monitor d014 Input electric power 0.0-999.9 kW monitor Accumulated time d016 monitor during 0.-9999./1000-9999/ 100- 999 h RUN d017 Power ON time 0.-9999./1000-9999/ 100- 999 h monitor d080 Number of trip time 0.-9999./1000-6553(10000-65530) (time) monitor d081 Trip monitor d082 Trip monitor d083 Trip monitor Trip Code, frequency(Hz), current(A), d084 Trip monitor voltage(V),RUN time(h) power ON time(h) d085 Trip monitor d086 Trip monitor d090 Warning monitor Warning code Output frequency 0.0, starting frequency-Max frequency F001 0.00 setting (2n d max r d max frequency)(Hz) st F002 acceleration time 0.01-99.99/100.0-999.9/1000 -3600.(s) 30.00 F202 2nd acceleration time 0.01-99.99/100.0-999.9/1000 -3600.(s) 30.00 F302 3rd acceleration time 0.01-99.99/100.0-999.9/1000 -3600.(s) 30.00 F003 1st deceleration time 0.01-99.99/100.0-999.9/1000 -3600.(s) 30.00 F203 2nd deceleration time 0.01-99.99/100.0-999.9/1000 -3600.(s) 30.00 F303 3rd deceleration time 0.01-99.99/100.0-999.9/1000 -3600.(s) 30.00 Operation direction F004 00(forward)/01(reverse) 00 selection (Note1) Change mode during run by selection of b031 (software lock selection) (Note2) Do not forget to press “STR” key when you change the display 1–2 Note Function Mode V/f characteristic Multistage speed,jogging frequency setting Analog input setting Base setting Code Function name A001 A002 Frequency setting selection Operation setting selection A003 Base frequency A203 A303 Base frequency, 2nd motor Base frequency, 3rd motor A004 A204 A304 A005 AT terminal selection A006 02 selection A011 SJ300 Setting range Initial data -FE/-FU/-F 01(terminal)/02(operator)/03(RS485)/04(option1)/05(option2) 01(terminal)/02(operator)/03(RS485)/04(option1)/05(option2) 01/01/02 01/01/02 30 - Maximum frequency(Hz) 50./60./60 30 – 2nd M aximum frequency (Hz) 30 - 3rd M aximum frequency (Hz) 50./60./60 50./60./60 Maximum frequency 30 – 400 (Hz) 50./60./60 Maximum frequency, 2nd motor Maximum frequency, 3rd motor 30 – 400 (Hz) 30 – 400 (Hz) 50./60./60 50./60./60 00( Changing of O and OI with AT terminal)/ 01(Changing of O and O2 with AT terminal) 00 start 00(single)/01(auxiliary speed of O, OI) [no reversible] / 02(auxiliary speed of O, OI [reversible] 0.00-99.99/100.0-400.0 (Hz) 0.00 A012 end 0.00-99.99/100.0-400.0 (Hz) 0.00 A013 A014 start rate end rate 0.-100.0 (%) 0.-100.0(%) 100 A015 start selection 00 (external starting frequency)/01(0Hz) 01 A016 O, OI, O2 sampling A019 Multi-speed selection 1.-30.(times) 00(binary : range is to 16 stage speed with terminals)/ 01(bit : range is to stage speed with terminals) A020 Multi-speed A220 A320 Multi-speed 0, 2nd motor Multi-speed 0, 3rd motor A021 A022 A023 00 00 0.00, starting frequency-maximum frequency(Hz) 0.00 0.00, starting frequency-2nd maximum frequency(Hz) 0.00, starting frequency-3rd maximum frequency(Hz) 0.00 0.00 Multi-speed1 0.00, starting frequency-maximum frequency(Hz) 0.00 Multi-speed2 Multi-speed3 0.00, starting frequency-maximum frequency(Hz) 0.00, starting frequency-maximum frequency(Hz) 0.00 0.00 A024 Multi-speed4 0.00, starting frequency-maximum frequency(Hz) 0.00 A025 A026 Multi-speed5 Multi-speed6 0.00, starting frequency-maximum frequency(Hz) 0.00, starting frequency-maximum frequency(Hz) 0.00 0.00 A027 Multi-speed7 0.00, starting frequency-maximum frequency(Hz) 0.00 A028 A029 Multi-speed8 Multi-speed9 0.00, starting frequency-maximum frequency(Hz) 0.00, starting frequency-maximum frequency(Hz) 0.00 0.00 A030 Multi-speed10 0.00, starting frequency-maximum frequency(Hz) 0.00 A031 A032 Multi-speed11 Multi-speed12 0.00, starting frequency-maximum frequency(Hz) 0.00, starting frequency-maximum frequency(Hz) 0.00 0.00 A033 Multi-speed13 0.00, starting frequency-maximum frequency(Hz) 0.00 A034 A035 Multi-speed14 Multi-speed15 0.00, starting frequency-maximum frequency(Hz) 0.00, starting frequency-maximum frequency(Hz) 0.00 0.00 A038 Jogging frequency 0.00, starting frequency-9.99(Hz) 1.00 A039 Jogging selection A041 Torque boost selection A241 Torque motor A042 A242 boost selection, 00(free-run on JG stop / invalid on running) / 01(stop decelerating on JG stop / invalid on running) / 02(DC braking on JG stop/invalid on running) / 03(free-run on JG stop/valid on running[JG after stop decelerating]) / 04 (stop decelerating on JG stop/valid on running) / 05 (DC braking on JG stop/valid on operating) 00 (manual torque boost) / 01 (automatic torque boost) 2nd 00 00 00 (manual torque boost) / 01 (automatic torque boost) 00 Manual torque boost Manual torque boost, 2nd motor 0.0-20.0(%) 0.0-20.0(%) 1.0 1.0 A342 Manual torque boost, 3rd motor 0.0-20.0(%) 1.0 A043 Manual torque boost point Manual torque boost point, 2nd motor 0.0-50.0(%) 5.0 0.0-50.0(%) 5.0 0.0-50.0(%) 5.0 A243 rd Direct current braking A343 Manual torque boost point, motor A044 1s t control A244 2nd control 00/(VC)/01(VP1.7power)/02(free V/f setting)/03(SLV)/ 04(0Hz-SLV)/05(V2) 00/(VC)/01(VP1.7power)/02(free V/f setting) /03(SLV)/04(0Hz-SLV) A344 3rd control 00/(VC)/01(VP1.7power) 00 A045 A051 Output voltage gain DC braking selection 20 - 100 00(invalid)/01(valid) 100 00 A052 DC braking frequency 0.00-60.00(Hz) 0.50 A053 A054 DC braking wait time DC braking power 0.0 - 5.0(s) - 100 ( %) 0.0 A055 DC braking time 0.0 - 60.0(s) 0.0 A056 A057 DC braking edge/level selection DC braking power (starting time) 00(edge action)/01(level action) - 100 ( %) 01 A058 DC braking time(starting time) A059 DC carrier frequency 0.00-60.0(s) 0.5-15(kHz) Derating (Note) < > indicate the setting range of 75 to 150kW 1- 00 00 0.0 5.0 Note Function Mode AVR PID control Upper and lower limiter,jump frequency Code 1s t frequency maximum limiter 2nd frequency maximum limiter 1s t frequency minimum limiter 2nd frequency minimum limiter Jump frequency1 Jump frequency Width Jump frequency2 Jump frequency Width Jump frequency3 Jump frequency Width Acceleration stop frequency Acceleration stop time PID selection PID-P gain PID-I gain PID-D gain PID scale PID feedback selection AVR selection A082 Motor voltage selection A085 A097 A098 A101 A102 A103 A104 A105 A111 A112 A113 A114 A131 Operation mode selection Energy-saving responseaccuracy adjustment Acceleration time2 Acceleration time2(2nd motor) Acceleration time2(3rd motor) Deceleration time2 Deceleration time2(2nd motor) Deceleration time2(3rd motor) 2nd stage adjustable selection 2nd stage adjustable selection(2nd motor) 2nd acceleration frequency 2nd acceleration frequency(2nd motor) 2nd deceleration frequency 2nd deceleration frequency (2nd motor) Acceleration pattern selection Deceleration pattern selection OI start OI end OI start rate OI end rate OI start selection O2 start O2 end O2 start rate O2 end rate Acceleration curve constant A132 Deceleration curve constant b001 Retry selection b002 Allowable under-voltage power failure time Retry wait time Instantaneous power failure/ under-voltage trip during stop Instantaneous power failure/ under-voltage retry time selection Open-phase selection Frequency setting to match Accel, Decel External frequency adjustment Operation mode/ adjustable function A086 Instantaneous power failure restart Function name A061 A261 A062 A262 A063 A064 A065 A066 A067 A068 A069 A070 A071 A072 A073 A074 A075 A076 A081 A092 A292 A392 A093 A293 A393 A094 A294 A095 A295 A096 A296 b003 b004 b005 b006 b007 SJ300 Setting range Initial data -FE/-FU/-F 0.00, 1s t frequency lower limitter - maximum frequency(Hz) 0.00, 2nd frequency lower limiter-2nd setting maximum frequency(Hz) 0.00, start frequency-maximum frequency(Hz) 0.00, start frequency-2nd setting maximum frequency(Hz) 0.00-99.99/100.0-400.0(Hz) 0.00-10.00(Hz) 0.00-99.99/100.0-400.0(Hz) 0.00-10.00(Hz) 0.00-99.99/100.0-400.0(Hz) 0.00-10.00(Hz) 0.00-99.99/100.0-400.0(Hz) 0.00-60.0(s) 00(invalid)/01(valid) 0.2-5.0 0.0-3600.(s) 0.00-100.0(s) 0.01-99.99(%) 00(feedback : OI)/01(feedback : O) 00(ON always)/01(OFF always)/02(OFF on decelerating) 0.00 0.00 0.00 0.00 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.0 00 1.0 1.0 0.00 1.00 00 00/00/02 (230/400)/ (230/460)/ (200/400) 00 200/215/220/230/240, 380/400/415/440/460/480 00(normal operation)/01(energy-saving operation)/02(Fuzzy) 0.0-100.0 50.0 0.01-99.99/100.0-999.9/1000.-3600.(s) 0.01-99.99/100.0-999.9/1000.-3600.(s) 0.01-99.99/100.0-999.9/1000.-3600.(s) 0.01-99.99/100.0-999.9/1000.-3600.(s) 0.01-99.99/100.0-999.9/1000.-3600.(s) 0.01-99.99/100.0-999.9/1000.-3600.(s) 00(change with 2CH terminal)/01(change with setting) 15.00 15.00 15.00 15.00 15.00 15.00 00 00(change with 2CH terminal)/01(change with setting) 00 0.00-99.99/100.0-400.0(Hz) 0.00 0.00-99.99/100.0-400.0(Hz) 0.00 0.00-99.99/100.0-400.0(Hz) 0.00 0.00-99.99/100.0-400.0(Hz) 0.00 00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve) 00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve) 0.00-99.99/100.0-400.0(Hz) 0.00-99.99/100.0-400.0(Hz) 0.-100 (%) 0.-100 (%) 00(external start frequency)/01(0Hz) -400. 100./-99.9-0.00-99.9/100.-400.(Hz) -400. 100./-99.9-0.00-99.9/100.-400.(Hz) -100 - 100 (%) -100 - 100 (%) 01(small swelling)-10(large swelling) 00 00 0.00 0.00 20 100 01 0.00 0.00 -100 100 02 01(small swelling-10(large swelling) 02 00(trip)/01(0Hz start)/02(start after equal frequency)/ 03(trip after equaling frequency and deceleration stop) 00 0.3-1.0(s) 1.0 0.3-100.(s) 00(invalid/01(valid)/02(invalid during stop and deceleration by stop command) 1.0 00(16 times)/01(free) 00 00(invalid)/01(valid) 0.00-99.99/100.0-400.0(Hz) 00 0.00 1- 00 Note Function mode Code Function name b012 Electronic thermal level 0.2*constant current-1.20*constant current(A) b212 Electronic thermal level (2nd motor) 0.2*constant current-1.20*constant current(A) b312 Electronic thermal level (3rd motor) 0.2*constant current-1.20*constant current(A) st Electronic thermal b013 b213 b313 b015 b016 b017 b018 b019 Free V/f setting Overload limit b020 Intelligent input terminal setting SJ300 Setting range electronic thermal characteristic selection 2nd electronic thermal characteristic selection 3rd electronic thermal characteristic selection Free electronic thermal frequency Free electronic thermal current Free electronic thermal frequency Free electronic thermal current Free electronic thermal frequency Free electronic thermal current Initial data -FE/-FU/-F Rated Current of inverter Rated Current of Inverter Rated current of inverter 00(reduced characteristic)/ 01(constant torque characteristic)/ 02(free setting) 00(reduced characteristic)/ 01(constant torque characteristic)/ 02(free setting) 00/(reduced characteristic)01(constant torque characteristic)/ 02(free setting) 01/01/00 0.-400.(Hz) 0.0-1000.(A) 0.0 0.-400.(Hz) 0.0-1000 (A) 0.0 0.-400.(Hz) 01/01/00 01/01/00 0.0-1000.(A) 0.0 01 b021 Overload restriction selection 00(invalid)/01(enabled on acceleration / constant speed)/ 02(enabled on constant speed)/03(enabled on acceleration / constant speed (speed increasing at regenerating mode)) b022 Overload restriction level 0.50* rated current-2.00* rated current(A) Rated current of Inverter x 1.50 b023 Overload restriction limit constant 0.10-30.00(s) 1.00 b024 Overload restriction selection b025 Overload restriction level b026 Overload restriction constant b031 Software lock mode selection b100 b101 b102 b103 b104 b105 b106 b107 b108 b109 b110 b111 b112 b113 Free V/f frequency Free V/f voltage Free V/f frequency Free V/f voltage Free V/f frequency Free V/f voltage Free V/f frequency Free V/f voltage Free V/f frequency Free V/f voltage Free V/f frequency Free V/f voltage Free V/f frequency Free V/f voltage C001 Intelligent input setting C002 Intelligent input setting C003 Intelligent input setting 00(invalid)/01(enabled on acceleration / constant speed)/ 02(enabled on constant speed)/03(enabled on acceleration / constant speed (speed increasing at regenerating mode)) 01 0.50*rated current-2.00*rated current(A) Rated current of inverter x1.50 0.10-30.00(s) 1.00 00(impossible to change the data except this item when SFT terminal is ON)/01(impossible to change the data except setting frequency item when SFT terminal is ON)/02(impossible to change the data except this item)/ 03(impossible to change the data except setting frequency item)/ 10(possible to change data on operating) 0.- Free V/f frequency2(Hz) 0.-800.0(V) 0.- Free V/f frequency3(Hz) 0.-800.0(V) 0.- Free V/f frequency4(Hz) 0.-800.0(V) 0.- Free V/f frequency5(Hz) 0.-800.0(V) 0.- Free V/f frequency6(Hz) 0.-800.0(V) 0.- Free V/f frequency7(Hz) 0.-800.0(V) 0.-400.(Hz) 0.-800.0(V) 01/(RV:Reverse is valid)/02(CF1:Multi-speed1)/ 03(CF2:Multi-speed2)/ 04(CF3:Multi-speed3)/ 05(CF4:Multi-speed4)/ 06(JG:Jogging)/ 07( DB:External DC braking)/ 08(SET:2nd control)/ 09(2CH:two-stage adjustable speed)/ 11( FRS:Free-run)/ 12( EXT:External trip)/ 13( USP:Unattended start protection)/ 14(CS:commercial change)/ 15(SFT:software lock)/ 16(AT:Analog input voltage/current select)/ 17(SET3:3 rd control)/ 18(RS:Reset inverter)/ 20(STA:3wire run)/ 01 0.0 0.0 0.0 0.0 0.0 0.0 0.0 18 16 06 21(STP:3wire keep)/ 22(F/R:3wire forward/reverse)/ 23(PID:PID selection valid/invalid)/ 24(PIDC:PID integrating reset)/ C004 Intelligent input setting 26( CAS:Control gain switch function)/ 27( UP:Remote control UP function)/ 11 28( DWN:Remote control DOWN function)/29( UDC:Remote control data clear)/ 31( OPE:Operating by operator select)/ 32(SF1:Multi-speed bit1)/ C005 Intelligent input setting 33(SF2:Multi-speed bit2)/ 34(SF3:Multi-speed bit3)/ 35(SF4:Multi-speed bit4)/ 09 C006 Intelligent input setting 36(SF5:Multi speed bit5)/ 37(SF6:Multi-speed bit6)/ 38(SF7:Multi-speed bit7)/ 39( OLR:Overload restriction change) / 40(TL:Torque limit select)/ 03/13/03 C007 Intelligent input setting C008 Intelligent input setting 41(TRQ1:Torque limit switch 1)/ 42(TRQ2:Torque limit switch 2)/ 43((PPI:P/PI switch)/ 44(BOK:Braking comformation)/ 45( ORT:Orientation)/ 46(LAC:LAD cancel)/ 47(PCLR:Position error clear)/ 48(STAT:Permission of pulse train)/ no(NO:No assign) (Note) < > indicate the setting range of 75 to 150kW 1- 02 01 Note Function mode Code C011 Input terminal setting intelligent C012 C013 C014 C015 C016 C017 C018 Intelligent output terminal setting C019 state terminal setting,Output level setting Output Initial data -FE/-FU/-F 00(NO)/01(NC) 00 00(NO)/01(NC) 00 00(NO)/01(NC) 00 00(NO)/01(NC) 00 00(NO)/01(NC) 00 00(NO)/01(NC) 00/01/00 00(NO)/01(NC) 00 00(NO)/01(NC) 00 00(NO)/01(NC) 00 00(RUN:running)/01(FA1:Frequency arrival type1 signal)/ 02(FA2:over setting frequency)/03( OL:Overload advance notice signal)/ 04( OD:Output deviation for PID control)/05( AL:Alarm signal)/ 06(FA3:Only setting frequency)/07( OTQ:Over-torque signal)/ 08( IP:On instantaneous stop)/09( UV:Under voltage)/ 10(TRQ:Torque limit)/11(RNT:RUN time over/12(ONT:ON time over)/ 13(THM:thermal caution)/19( BRK:Brake release signal)/ 20( BER:Brake error signal)/21( ZS:Zero speed detect signal)/ 22(DSE:Speed error over signal)/23( POK:Positioning completion signal) 24(FA4:Over frequency signal)/25(FA5:Only setting frequency)/ 26(OL2: Overload advance notice signal 2) (Intelligent output terminal 11-13 or 11-14 becomes AC0-AC2 or AC0-AC3 (Can:Alarm cord output) forcibly when alarm cord output is selected in C062) 00(Output frequency)/01(Output current) /02(Output torque)/ 03(Digital output frequency)/04(Output voltage)/ 05(Input electric power)/06(thermal load rate)/07(LAD frequency) 00(Output frequency)/01(Output current)/02(Output torque)/ 04(Output voltage)/05(Input electric power)/06(thermal load rate)/ 07(LAD frequency) 00(Output frequency)/01(Output current)/02(Output torque)/ 04(Output voltage)/05(Input electric power)/ 06(Thermal load rate)/07(LAD frequency) 00(NO)/01(NC) 00(NO)/01(NC) 00(NO)/01(NC) 00(NO)/01(NC) 00(NO)/01(NC) 00(NO)/01(NC) Intelligent output 11 setting C022 Intelligent output 12 setting C023 Intelligent output 13 setting C024 Intelligent output 14 setting C025 Intelligent output 15 setting C026 Alarm relay output C027 FM selection C028 AM selection C029 AMI selection C031 C032 C033 C034 C035 C036 C072 C073 C074 C075 C078 Intelligent output 11 a/b Intelligent output 12 a/b Intelligent output 13 a/b Intelligent output 14 a/b Intelligent output 15 a/b Alarm relay output a/b Overload advance notice signal output mode Overload advance notice level Frequency arrival setting for acceleration Arrival frequency setting for deceleration PID deviation setting level Frequency arrival setting for acceleration Arrival frequency setting for deceleration Over torque level setting (Forward-driving) Over torque level setting (Reverse-regenerating) Over torque level setting (Reverse-driving) Over torque level setting (Forward-regenerating) Thermal warning level setting Alarm code selection Zero speed detection level setting Data command Communicating transmission speed Communication code Communication bit Communication parity Communication stop bit Communication waiting time C081 O adjustment 0.-9999./1000-6553(10000-65530) C082 OI adjustment 0.-9999./1000-6553(10000-65530) C083 O2 adjustment 0.-9999./1000-6553(10000-65530) Setting on forwarding Setting on forwarding Setting on forwarding C085 C086 C087 Thermistor adjustment AM offset adjustment AMI adjustment 0.0 - 1000 0.0 - 10.0(V) - 255 105.0 0.0 80 C088 AMI offset adjustment - 20.0( mA) 4.0 C041 C042 C043 C044 C045 C046 C055 C056 C057 C058 C061 C062 C063 Communication function adjustment Intelligent input a/b (NO/NC) selection Intelligent input a/b (NO/NC) selection Intelligent input a/b (NO/NC) selection Intelligent input a/b (NO/NC) selection Intelligent input a/b (NO/NC) selection Intelligent input a/b (NO/NC) selection Intelligent input 7a/b (NO/NC) selection Intelligent input a/b (NO/NC) selection Input FW a/b (NO/NC) Selection SJ300 Setting range C021 C040 Analog meter setting Function name C070 C071 01 00 03 07 08 05 00 00 00 00 00 00 00 00 01 00(On accel And decel, constant speed)/01(Only constant speed) 01 0.0-2.0*rated current(A) Inverter rated current 0.00-99.99/100.0-400.0(Hz) 0.00 0.00-99.99/100.0-400.0(Hz) 0.00 0.0-100.0(%) 3.0 0.00-99.99/100.0-400.0(Hz) 0.00 0.00-99.99/100.0-400.0(Hz) 0.00 0.-200.(%) 100 0.-200.(%) 100 0.-200.(%) 100 0.-200.(%) 100 0.-100.(%) 80 00(Invalid)/01(3bit)/02(4bit) 00 0.00-99.99/100.(Hz) 0.00 02(operator)/03(RS485)/04(option1)/05(option2) 02(loop-back test) 03(2400bps)/04(4800bps)/05(9600bps)/06(19200bps) - 32 7(7bit)/8(8bit) 00(no parity name)/01(even parity)/02(odd parity) 1(bit)/2(bit) 0.-1000.(ms) 02 (Note) < > indicate the setting range of 75 to 150kW 1- 04 00 Note Function mode Function name SJ300 Setting range Initial data -FE/-FU/-F b034 b035 b036 b037 RUN time/Power ON time level 00 06 00 b040 Torque limit mode selection 0.-9999./1000-6553(10000-65530)hr 00(Reverse is valid)/01(Only forward)/02(Only reverse) 00(Start reduced voltage time small)-06(Start reduced voltage time large) 00(all display)/01(each function display)/02(User setting / main setting) 00(4 quadrant mode)/01(Terminal operation)/ 02(Analog input)/03(Option1)/04(Option2) 0.-200.(%)/no(Invalid) 150 0.-200.(%)/no(Invalid) 150 0.-200.(%)/no(Invalid) 150 0.-200.(%)/no(Invalid) 150 00(Invalid)/01(Valid) 00 00(Invalid)/01(Valid) 00 00(Invalid)/01(Valid) 00 0.0-1000.(V) 0.0 0.0-1000.(V) 0.0 0.01-99.99/100.0-999.9/1000.-3600.(s) 1.00 0.00-10.00(Hz) 0.00 - 255 - 255 0.10-9.99(Hz) 0.5-15.0(kHz) Derating enable, 00(Trip history clear)/01(Data initialization)/ 02(Trip history clear + data initialization) 00(Interior)/01(EC)/02(USA) 180 60 0.50 5.0 0.1-99.9 1.0 00(valid)/01(invalid) 00 Code b080 b081 b082 b083 Torque limit level setting (Forward-driving at quadrant mode) Torque limit level setting (Reverse-regenerating at quadrant mode) Torque limit level setting (Reverse-driving at quadrant mode) Torque limit level setting (Forward-regenerating at quadrant mode) Torque LAD-STOP selection Reverse run prevention selection Selection of non-stop function at instantaneous power failure Start voltage of non-stop function setting OV LAD-STOP level of nonstop function setting Deceleration time of nonstop function setting Deceleration frequency widt h of non-stop function setting AM adjustment FM adjustment Start frequency adjustment Carrier frequency setting b084 Initialize mode b085 b090 b091 Country code for initialization Frequency scalar conversion factor STOP key enable Resume on FRS cancellation mode BRD usage ratio Stop mode selection b092 Cooling fan control b095 b096 b098 b099 b120 b125 BRD selection BRD ON level Thermistor selection Thermistor error level Braking control selection Waiting time for releasing braking conformation Waiting time for acceleration Waiting time for stop Waiting time for signal conformation Releasing frequency b126 Releasing current C091 C101 Debug mode selection UP/DWN selection C102 Reset selection C103 Reset f frequency matching selection b041 b042 b043 b044 b045 b046 b050 b051 b052 The others Operation direction restrict Start reduced voltage Display selection b053 b054 b086 b087 b088 b121 b122 b123 b124 advance 00 00 01/02/00 00(0Hz start)/01(Start f-equaling) 00 0.0-100.0(%) 00(deceleration stop)/01(Free-run stop) 00(Always ON)/ 01(ON during run, After power ON, then for minutes on stop is implied.) 00(invalid)/01(valid)/02(valid) 330-380/660-760(V) 00(invalid)/01(Positive temperature coefficient enable)/02 (NTC enable) - 9999 ( ohm) 00(Invalid)/01(valid) 0.0 00 00 360/720 00 3000 00 0.00-5.00(s) 0.00 0.00-5.00(s) 0.00-5.00(s) 0.00 0.00 0.00-5.00(s) 0.00 0.00-99.99/100.0-400.0(Hz) 0.00 Rated current of inverter 00 00 0.00*rated current-2.00*rated current(A) 00(No display)/01(Display) 00(No frequency data)/01(Keep frequency data) 00(Trip cancel during ON)/01(Trip cancel during OFF)/ 02(Valid only during trip) notice 00 00 00(0Hz start)/01(Start f-equaling) 00 0.0-2.0*rated current(A) Inverter rated current C111 Overload level C121 O zero adjustment 0.-9999./1000-6553(10000-65530) C122 OI zero adjustment 0.-9999./1000-6553(10000-65530) C123 O2 zero adjustment 0.-9999./1000-6553(10000-65530) (Note) < > indicate the setting range of 75 to 150kW 1- Set on forwarding Set on forwarding Set on forwarding Note