7 power quality

33 379 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 33
Dung lượng 1,07 MB

Nội dung

Power Systems & Energy Course: Power Quality Issues with Large-Scale Renewable Plants Jason MacDowell Power Quality – Renewable Plant Perspective • Power quality is a two way street! • Plant effect on grid • Grid effect on plant • Interconnection requirements are typically imposed at the PCC (Point of Common Coupling) • Impacts at the PCC are a function of: • Diversity of the individual WTGs/PV arrays • Characteristics of the collector system • Characteristics of the transmission grid © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-2 Power Quality Basics Undervoltages: Notch – less than one cycle duration Dip – duration of a few cycles Sag – duration of seconds to minutes Interruption – reduction to zero for seconds to minutes Overvoltages: Spike – less than one cycle duration Swell – duration of cycles or more Waveform Distortion: Harmonics – steady-state distortion affecting every cycle integral multiples of operating frequency Interharmonics – non-integral multiples of operating frequency Noise – random high-frequency signals Frequency Shift – variations in frequency through time Flicker – cyclic or random variations in voltage magnitude Unbalance – phase asymmetry © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-3 Flicker Flicker is caused by repetitive variations in voltage – can be irritant to utility customers House Pumps Sump Pumps Air-Conditioning Equipment Domestic Refrigerators Oil Burners Arc Furnace Flashing Signs Arc-W elders Manual Spot-W elders Sews Group Elevators Single Elevator Heights Y-delta Changes on Elevator-MotorGenerator Sets X-Ray Equipment Reciprocating Pumps Compressors Automatic Spot-W elders % Voltage Fluctuation Border Line of Irritation Border Line of Visibility 1 10 Fluctuation per Hour 20 30 10 Fluctuation per Minute 20 30 60 10 15 Function per Second Measurement of flicker has been standardized by IEC, using “flickermeter” algorithm (IEC 61000-4-15) © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-4 Flicker in Wind Plant Applications • Sources of flicker: – – – – Wind turbulence, gusting Drive-train oscillations Blades passing tower Induction generator close-in inrush • Diversity reduces impact on a large wind plant • DFAG and full-conversion reduces impact • GE WTG voltage regulation capability virtually eliminates issue • For induction generators, dynamic compensation could be required to meet tight grid specs © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-5 Flicker in Large PV Plants • Cloud shadow passage potentially can cause significant voltage variation – Frequency of variations usually not sufficient to be technically considered “flicker” unless variations are very large – Very large voltage variations would be unacceptable for other reasons • Output of PV plants becomes smoother as plant rating increases – Finite size of cumulus clouds that cause the most intermittent shadowing – Output of very large plants approaches (1 - %overcast)*Pclear_sky • Plant level voltage regulation can readily mitigate voltage variation © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-6 Non-Repetitive Voltage Change • Some grid codes limit step voltage changes – Typically 1% - 2% for frequent events – Some codes relax limits to 3% for infrequent events • Causes: – – – – Capacitor/reactor bank switching Transformer energization Feeder switching Interconnecting HV cable switching • Solutions: – Limit size of individually switched banks (Qmax = DV x MVASC) – Controlled transformer energization – Resistor preinsertion – Point-on-wave switching – Compensation of HV cables © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-7 Voltage Transients Affecting Grid • Transients are sub-cycle overvoltages • In wind plant, usual cause is capacitor switching – Ringing oscillations, usually at several hundreds of Hz – Severity depends on point-on-wave of energization • Solutions – Synchronized switching -switch closes near voltage zero – Ideally, eliminates transient – Experience has been that switchgear must operate often to “keep in training” – Impedance preinsertion – Resistor preinsertion (breakers) – Lossy inductor (circuit switchers) © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-8 What are Harmonics? • Non-fundamental-frequency AC currents and voltages superimposed on the system – Frequencies are multiples of normal system frequency – Interharmonics are non-integral multiples • Results in repeated distortion of the sine wave • System impacts: – – – – Capacitor overload Excess heating Device misoperation Telecommunication interference © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-9 Harmonic Sources in Renewable Plants • Power converters (used in DFAG, full conversion, and controlled rotor resistance induction generators) • PV inverters • Generators • Dynamic compensation equipment – SVCs, STATCOMS • The grid! © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-10 The Grid as a Harmonic Source • Most grids have significant background distortion – Due to nonlinear loads, P-E devices, transformers – Greatest at 3rd, 5th, and 7th harmonic • Good data requires extended-duration monitoring • IEEE-519 sets “recommended practice” for utilities: 69 – 161 kV > 161 kV V THD 1.5% 2.5% 1.0% 1.5% 1.6 1.4 1.2 Voltage (%) Vh Measurements made on an actual utility system 0.8 0.6 0.4 0.2 10 11 12 13 14 15 Harmonic © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-19 Harmonics Injected by Grid Into Plant PCC  Zgrid IPCC VHarm IWTG Harmonics from the grid are a major portion of IPCC © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-20 Resonant Amplification of Grid Harmonics • Wind plant presents a series resonant circuit – Substation transformer + capacitor banks & cable charging – Can amplify grid distortion • Problems caused by excess harmonics in collector system – Capacitor overload – Component heating (WTG, transformers, cable) – Misoperation Vcoll Vh Icap I cap  Vh Z L  ZC Vcoll  Vh  Zc Z L  ZC A lightly damped resonance can cause severe voltage distortion on collector, and high currents in shunt capacitors © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-21 HARMONIC ANALYSIS © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-22 Harmonic Analysis Software Tools Steady-state phasor analysis – one frequency at a time • Time-domain modeling tools are not needed • Some time-domain tools also perform phasor analysis (e.g., EMTP, ATP) Capability to represent frequency-dependent characteristics of network components • XL = 2fL XC =-1/(2fC) • Long-line characteristics of cables and overhead lines • Frequency-dependent damping characteristics are extremely important Must handle a large number of configurations © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-23 Source Characteristics of WTGs/Inverters Modern PV inverters and wind turbines not look like an ideal harmonic current source • Internal filters are in shunt • VSC bridge appears like: – Ideal current source at low frequency (within controller bandwidth) – Ideal voltage source at high frequency (f >> controller bandwidth) – Complex transition of characteristics in between • Shunt impedance of machine Norton equivalent is the preferred representation • Source magnitude spectrum depends on operating point • Equivalent shunt source impedance is a complex function of frequency – does not conform to simple models Characteristics best determined by detailed time-domain simulation with controls modeled © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-24 WTG representation (Internal Distortion) • Doubly-fed asynchronous generator machine • Low distortion energy: – Converter operated with high switching frequency – Converter rating is a fraction of turbine rating • Small distortion filter within the turbine to absorb most of the distortion energy created by the converter Conceptual converter harmonic current distortion flows © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-25 WTG representation and field WTG measurements • Machine presents a shunt impedance to the grid that will absorb distortion currents • Most of measured distortion currents are due to external sources • Harmonic current measurements are severely affected by distortion of external sources Harmonic measurement point Conceptual external source harmonic current distortion flows © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-26 WTG representation – Norton Equivalent • Study assumptions based on physics of the system • Realistic system distortion estimation: – due to WTG – due to external sources (availability of Norton impedances) • Proper measurement interpretations © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-27 Grid Impedance at Harmonic Frequencies • Transmission grid impedance is important to both studies of: – Ambient distortion amplification in the renewable plant – Harmonic current injection by plant into grid • Grid impedance varies with: – – – – Load level Generation commitment Capacitor bank status Line outages Range of impedance for an example transmission bus © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-28 MITIGATING HARMONICS © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-29 Mitigating Grid Harmonic Amplification • Avoid resonances – Selection of transformer impedances and capacitor bank ratings – This option is limited by the wide range of tunings possible – Avoid certain operating configurations – E.g., start up WTGs on one feeder before switching in another feeder, on startup – Detune shunt capacitors – Add inductor in series with capacitor – Capacitor cannot resonate at a frequency higher than the frequency defined by the L-C combination – Typical to select L-C to resonant at 4.8th harmonic • Filter out harmonics – Complex design – Necessary if wind plant is an objectionable harmonic source © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-30 Harmonic Filter Topologies 10 10 10 Impedance Single-Tuned Filter 100 Zn 10 0.1 0.01 10 10 10 High-Pass Filters 100 10 fn Fre que ncy 10 100 10 fn Fre que ncy 10 10 Impedance Zn 10 100 10 © 2016act General Electric International, Inc All rightsbanks reserved Not distribution without permission Filters like shunt capacitor at forfundamental frequency 11-31 Practical Filter Design Considerations • Initial tuning tolerance – Tuning taps on inductors – Variable inductors • Operational variations – Temperature variations (capacitors) – Component failures (capacitors) – System frequency variation – Component aging Filter design must be sufficiently robust to meet design objectives for expected variations © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-32 Final Remarks • Modern WTG/PV converters tend to cause low distortion at PCC: – High frequency PWM converter switching – Distortion filter • Harmonic system studies should be based on realistic converter modeling guidelines • Wind/Solar plant equipment can create resonances (Shunt Caps), particularly to grid distortion If shunt capacitors are required, consider de-tuning • If filters are needed, design must be sufficiently robust to meet design objectives for expected variations © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11-33 [...]... without permission 11-12 Harmonic Performance Specifications IEEE 519 specifies the following limits for “dispersed generation”: Harmonic Order h < 11 12 - 17 18 - 23 23 - 35 35 - 50 Odd 2.0% 1.0% 0 .75 % 0.3% 0.15% Even 0.5% 0.25% 0.1 87% 0. 075 % 0.0 37% THD THD  2.5% 50  Ih 2 h2 • Voltage specifications might also be made (individual, and RSS) • Need to consider impact on wind plant equipment as well:... nonlinear loads, P-E devices, transformers – Greatest at 3rd, 5th, and 7th harmonic • Good data requires extended-duration monitoring • IEEE-519 sets “recommended practice” for utilities: 69 – 161 kV > 161 kV V THD 1.5% 2.5% 1.0% 1.5% 1.6 1.4 1.2 Voltage (%) Vh Measurements made on an actual utility system 1 0.8 0.6 0.4 0.2 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Harmonic © 2016 General Electric International,... amplification is reduced • In a realistic system, harmonic voltages and currents can be greatly amplified © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11- 17 Resonance Example 0.15 15 Per-unit harmonic voltage 0.1 Current amplification factor 10 Vf If 0.05 0 5 0 200 400 f 600 0 0 200 400 600 f Typical wind plant parameters, 1% harmonic current injection from...WTG/Inverter Harmonics • PV inverters, and power converters used in most WTGs use PWM technology – Harmonics are clustered around multiples of the switching frequency – High frequency; are easily filtered – Random phase superposition self-cancels... to external sources (availability of Norton impedances) • Proper measurement interpretations © 2016 General Electric International, Inc All rights reserved Not for distribution without permission 11- 27 Grid Impedance at Harmonic Frequencies • Transmission grid impedance is important to both studies of: – Ambient distortion amplification in the renewable plant – Harmonic current injection by plant into ... “dispersed generation”: Harmonic Order h < 11 12 - 17 18 - 23 23 - 35 35 - 50 Odd 2.0% 1.0% 0 .75 % 0.3% 0.15% Even 0.5% 0.25% 0.1 87% 0. 075 % 0.0 37% THD THD  2.5% 50  Ih h2 • Voltage specifications.. .Power Quality – Renewable Plant Perspective • Power quality is a two way street! • Plant effect on grid • Grid effect on plant... Electric International, Inc All rights reserved Not for distribution without permission 11-2 Power Quality Basics Undervoltages: Notch – less than one cycle duration Dip – duration of a few cycles

Ngày đăng: 19/12/2016, 12:53

Xem thêm

TỪ KHÓA LIÊN QUAN