Exergoeconomic multiobjective optimization of an externally fired gas turbine integrated with a biomass gasifier

12 319 0
Exergoeconomic multiobjective optimization of an externally fired gas turbine integrated with a biomass gasifier

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Applied Thermal Engineering 91 (2015) 848e859 Contents lists available at ScienceDirect Applied Thermal Engineering journal homepage: www.elsevier.com/locate/apthermeng Research paper Exergoeconomic multi-objective optimization of an externally fired gas turbine integrated with a biomass gasifier Shoaib Khanmohammadi*, Kazem Atashkari, Ramin Kouhikamali Department of Mechanical Engineering, Faculty of Engineering, University of Guilan, P.O Box 3576, Rasht, Iran h i g h l i g h t s  Apply a modified thermodynamic equilibrium modeling for a biomass gasifier  Apply a multi objective optimization technique based on a developed code in Matlab  Perform a sensitivity analysis to better understanding of decision variables change a r t i c l e i n f o a b s t r a c t Article history: Received June 2015 Accepted 27 August 2015 Available online September 2015 This study deals with thermodynamic and economic analysis of a combined gas turbine and Organic Rankine Cycle integrated with a biomass gasifier A modified model is used to increase the precision of the gasifier thermodynamic model Seven decision variables, namely, biomass gasification temperature (Tgasif), combustion temperature (Tcomb), gas turbine inlet temperature (T3), gas turbine isentropic efficiency (hGT), compressor isentropic efficiency (hcomp), compressor pressure ration (rp) and maximum ORC operating pressure (P3R), are selected as the main decision variables of the combined system The total cost rate and exergy efficiency of the system are chosen as the two main objective functions A group method of data handling (GMDH) type neural network and evolutionary algorithm (EAs) are used for modeling the effects of the seven decision variables on both objective functions The result of multiobjective optimization shows that the exergy efficiency of the system is 15.6%, which can be increase to 17.9% in the optimal state, regardless of the total cost rate of system as objective function In addition, in order to better illustrate the effects of decision variables change in three selected points of the Pareto curve, a sensitive analysis is performed © 2015 Elsevier Ltd All rights reserved Keywords: Externally fired gas turbine Gasification Multi-objective optimization Organic Rankine cycle Introduction The depletion of fossil fuels, environmental pollutions, greenhouse gas emissions, and global climate changes together with the potential of biomass to meet a part of energy demand have converted biomass as one of promising renewable energy source [1,2] The comprehensive energy policies adopted by governments have developed significant research in this area and have paved the way for utilizing such renewable energies In general, renewable energies can further reduce the environmental impacts and enhance energy security as well Biomass sources such as paper, agricultural products, forestry residues, stems, wood, and cane are examples of * Corresponding author Tel.: þ98 133 6690271 E-mail address: khshoaib@phd.guilan.ac.ir (S Khanmohammadi) http://dx.doi.org/10.1016/j.applthermaleng.2015.08.080 1359-4311/© 2015 Elsevier Ltd All rights reserved the renewable sources with low heating value for energy production Biomass is considered as renewable energy source because the carbon in biomass is regarded as part of the natural carbon cycle The recent studies on this issue mainly focus on a more efficient simulation this type of energy conversion and more accurate thermodynamic modeling of biomass gasification and biomass combustion Generally, the efficiency of power production using biomass is low For example, the efficiency in small and large systems is almost 15% and 30%, respectively [3] The use of biomass in gas turbines has its own problems The gas turbine is a highly sensitive mechanical device in which require extremely clean gas so biomass combustion product needs expensive filters in order to prevent fuel injector and routes from blocking and preventing turbine blades from different damages Also, the syngas produced with a low heating value by gasification process for use in a gas S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 Nomenclature A C_ CRF DHW ex HHV i LHV m m0 _ m n N ORC rp Area (m2) Cost rate ($/h) Capital recovery factor Domestic hot water heater Exergy (kJ/kg) Higher heating value (kJ/kg) Interest rate Lower heating value (kJ/kg) Number of moles required for firing per kmole of wood Number of mole required for complete combustion per mole of syngas Mass flow rate (kg/s) function year Annual function hour per component Organic Rankine cycle Pressure ratio Subscripts AP Air preheater C Carbon cc Combustion chamber ch Chemical comb Combustion turbine combustion chamber requires a large amount of air for combustion process, which this can expose compressor to surge [4] The above-mentioned problems could be resolved by using external combustion of biomass and a high temperature heat exchanger Datta et al [5] discussed energy and exergy analysis for an externally fired gas turbine including biomass gasification process for distributed power generation They used thermodynamic equilibrium modeling for simulation syngas production from biomass and carried out energy and exergy analysis The study of the effect of important parameters such as cold end temperature of heat exchanger and compressor pressure ratio were parts of their investigations They obtained thermal efficiency of system between 16% and 34% depending on design parameters variations Arnavat et al [6] considered a trigeneration system using biomass as a prime mover The system consisted of biomass gasification and use of syngas to drive an internal combustion engine and utilize waste heat to drive a double-effect absorption chiller In their study, five configurations for power generation, heating and cooling were considered in which each one of them had the same investment cost but with different power, heating and cooling output In another study Ahmadi et al [7] considered a novel multi generation biomass-based integrated energy system They performed a multiobjective optimization method to determine the best design parameters for the system A sensitivity analysis was conducted to show the effect of design parameters on exergy efficiency, total cost rate, and CO2 emission Soltani et al [8] performed a thermodynamic analysis of an externally fired gas turbine with biomass gasification They considered three cases based on the variations in compressor pressure ratio and temperature difference of the cold end of the heat exchanger to find the impact of parameter variations on three cases Their results indicated that gasifier and combustion chamber have the highest rate of irreversibility In another study, Soltani et al [9] carried out exergy analysis for a system with co-firing of natural gas and biomass Their analysis comp Cond, R Ev, R f G gasif GT h K LM Ph prod Pump, R R React T Tur, R w Z o 849 Compressor Organic condenser Organic evaporator Formation Gasifier Gasification Gas turbine Enthalpy (kJ/kg) Equilibrium constant Logarithm Physical Product Organic pump Universal gas constant (kJ/kg K) Reactant Temperature Organic turbine Amount of water per kmol of biomass Cost of component Reference state Greek symbols b Biomass exergy coefficient Operation and maintenance factor j Exergy efficiency included a review of the effects of compressor pressure ratio and compressor isentropic efficiency and the effects of mass ratio of natural gas to biomass flow rate for a system with 80 MW power output Soltani et al [10] also compared performance of two combined cycle configurations included co-firing of natural gas and biomass Their study included an assessment of the exergoeconomic of these two systems and the effects of various parameters on their performance Their analysis showed that the configuration with co-firing of natural gas and biomass show a better performance than the pure biomass configuration in terms of lower economic factors and lower cost of biomass The results show that energy and exergy efficiencies of the configuration with cofiring of natural gas and biomass were 2% and 4% higher than pure biomass Ahmadi et al [11] carried out an multi-objective optimization for a new multi-generation energy system including power, heating, cooling, hot water and hydrogen They merge the new environmental cost function with the thermoeconomic cost objective and introduce a useful thermoenvironomic function The results of multi objective optimization suggest the best values for the design parameters In other research, Ahmadi et al [12] presented an exergo-environmental analysis for an integrated organic Rankine cycle for tirgeneration purpose The results show that exergy efficiency and sustainability index increase with increasing compressor pressure ratio and gas turbine inlet temperature A review of the above studies indicates that most of the investigations examine the performance variations in different configurations of system Given that the results of the studies must finally result in the selection of the optimal cycle in terms of economic and thermodynamic performance, the optimization of the relevant systems is necessary both in terms of economic and thermodynamic considerations Regarding the lack of investigations in thermoeconomic and optimization of the previous studies, the present work concentrates firstly to develop models of thermodynamic and economics of an organic Rankine cycle and an externally fired gas turbine integrated with a biomass gasifier The second part of this work is to apply multi-objective optimization 850 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 procedure to find the optimum working conditions and to show sensitivity of the optimum performances in terms of decision variables The overall objectives of this study can be summarized as follows:  Applying a modified model of thermodynamic equilibrium for the gasification system  Exergy analysis of the proposed system to obtain the first objective function  Development of economic model of the system to obtain the second objective function  Multi objective optimization procedure using evolutionary genetic algorithm for producing Pareto front System modeling A schematic of combined gas turbine and Rankine cycle integrated with the syngas producer shown in Fig The system consists of a hot air driven gas turbine The gasifier in the system produces syngas using gasification of dry biomass The product of combustion exiting combustion chamber is at 1177 C as shown in Fig The products enter the ceramic heat exchanger to increase exiting air from the compressor This type of high temperature ceramic heat exchanger is capable of raising the air temperature up to 1350 C The airside can handle air at pressures from bar to 13 bar, which makes this exchanger ideal for using clean air to drive a gas turbine In the ceramic heat exchanger, exiting a part of the combustion products is removed to the evaporator of organic Rankine cycle The reminder of combustion products enters into another heat exchanger to produce domestic hot water Finally, products of combustion discharges into the ambient at 130 C Furthermore, the initial designing state of the system is listed in Table The thermodynamic properties of streams and system performance are evaluated with EES (Engineering Equation Solver) In addition, a code developed in Matlab software program using an evolutionary algorithm is used to perform multi-objective optimization method 2.1.1 Gasifier Thermodynamic equilibrium procedure has been used for modeling the process in the gasifier [39] The chemical reaction in the gas producer system is assumed as: CHx Oy Nz þ wH2 O þ mðO2 þ 3:76N2 Þ/x1 H2 þ x2 CO þ x3 CO2 þ x4 H2 O þ x5 CH4 þ x6 N2 (1) Here, CHxOyNz denotes the biomass chemical formula and w is the amount of water per kmol of biomass All coefficients x1 to x6 are obtained by performing atomic balance and using equilibrium constant equations The procedures are given as follows: x2 þ x3 þ x5 ¼ (2) 2x1 þ 2x4 þ 4x5 ¼ x þ 2w (3) x2 þ 2x3 þ x4 ¼ y þ w þ 2m (4) x6 ¼ z þ 3:76 Â 2m (5) To obtain the rest of equations two equilibrium equations are derived As it is expected that pyrolysis products before reaching reduction region are fired and prior to emitting from gasifier achieve equilibrium state, the reactions can be written as follows: C þ 2H2 /CH4 (6) CO þ H2 O/CO2 þ H2 (7) The above reactions are known as methanation reaction and gasewater shift reaction, which the equilibrium constants for them are given as follows: K1 ¼ K2 ¼ PCH4 x5 x21 (8) PCO2 PH2 x x ¼ PCO PH2 O x2 x4 (9) P2H2 ¼ 2.1 Thermodynamic model Finally, for the calculation of gasification temperature (Tgasif) the energy balance is applied as: Before proceeding to the development of each components thermodynamic model, the assumptions for the system are given as follow:         hf;biomass þ whf;H2 O ¼ x1 hf;H2 þ Dh þ x2 hf;CO þ Dh       þ x3 hf;CO2 þ Dh þ x4 hf;H2 O þ Dh       þ x5 hf ;CH4 þ Dh þ x6 hf;N2 þ Dh  The molar compositions of standard air are taken 79% nitrogen, 21% oxygen in 101.325-kPa and 25 C [10]  The biomass moisture content for the system under study is considered 16%  The gas turbine isentropic efficiency is 89% [13]  The isentropic compressor efficiency 87% [10]  The pressure drop in the combustor chamber is 0.5% of inlet pressure [13]  The isentropic efficiency of the turbine and pump with organic fluid is 85% and 70% respectively [10]  The pressure drop in hot and cold fluid of heat exchanger is 3% and 1.5% of inlet pressure respectively [13]  The ultimate analysis of dry biomass (wood) shows the compounds as: 50% carbon, 6% hydrogen, 44% oxygen [14]  The cost of biomass (wood) is considered $/GJ [15] and Dh is enthalpy difference value for the given state with reference state The wood chemical formula based on one carbon atom could be written in the form of CH1.44O0.66 [14] (11) (10)  where, hf ;i is the formation enthalpy in terms of kJ/kmol, and its value for all the chemical compositions is zero in the reference state  2.1.2 Combustion chamber A complete combustion process is assumed in the combustion chamber of the system As given by the following: x1 H2 þ x2 CO þ x3 CO2 þ x4 H2 O þ x5 CH4 þ x6 N2 þ m0 ðO2 þ 3:76N2 Þ/aCO2 þ bH2 O þ cO2 þ dN2 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 851 Fig A schematic of the modeled cycle with the external combustion of the syngas produced from wood biomass and organic Rankine cycle The coefficients x1 to x6 have already been calculated and m0 is the number of mole required for complete combustion per mole of syngas Applying atoms balance and using energy equation similar to equation (10) for the combustion chamber m0 is calculated X  hf ;j ¼ j¼react X     ni hf;i þ DhTcomb;i (12) j¼Prod LMTD is a logarithmic average of the temperature difference between the hot and cold feeds at each end of the double pipe exchanger The larger the LMTD, the more heat is transferred The use of the LMTD arises straightforwardly from the analysis of a heat exchanger with constant flow rate and fluid thermal properties For the ceramic heat exchanger LMTD can be express as: LMTDHE ¼ 2.1.3 Ceramic heat exchanger Considering energy balance equation between hot and cold stream, it is possible to achieve the following equation for the heat exchanger [40] _ air ðh3 À h2 Þ _ prod ðh5a À h6 Þ ¼ m m (13) It should be mentioned that heat loss to environment is neglected The concept of logarithmic mean temperature difference (LMTD) is used to determine the temperature deriving force for heat transfer in flow systems, most notably in heat exchangers The ðT6 À T2 Þ À ðT5 À T3 Þ   ln TT65 ÀT ÀT3 2.2 Exergy analysis Mass, energy and exergy balance for each component of the system are applied The following equation is used to obtain irreversibility in each component [16] X _ in exin ¼ m X _ out exout þ I_ m Parameter Value Unit Gasification temperature Combustion temperature Gas turbine inlet temperature Compressor pressure ratio 827 1177 877  Biomass flow rate Biomass moisture content ORC maximum pressure Air gasification mass flow rate Air combustion mass flow rate 0.8 16 1000 1.09 6.24   C C C e kg/s % kPa kg/s kg/s (15) out in The exergy of each stream is composed of two parts including chemical and physical one ex ¼ exph þ exch Table Initial performance parameter of the integrated system (14) (16) The physical exergy of each stream depends on its temperature and pressure and is given as follows: exph ¼ ðh À ho Þ À To ðs À so Þ (17) where o is reference state In addition, the chemical exergy of gas mixture could be obtained through the following equation [41]: exch ¼ X i xi exch o;i þ RT+ X i xi Lnxi (18) 852 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 here xi is molar fraction of ith component and exch is standard o;i exergy of ith pure material [17] To obtain the fuel chemical exergy, it is required to calculate the lower heating value of fuel and the coefficient b which is calculated as follows [5,8]: exbiomass ¼ bLHVwood Table Exergy destruction rate and exergy efficiency for different components Component Exergy destruction rate Exergy efficiency Compressor _ D ¼ Ex _ þW _ À Ex _ Ex C WC _ À Ex _ þ Ex _ 5a À Ex _ _ D;HE ¼ Ex Ex Heat exchanger _ b¼   1:044 þ 016 ZZHC À :34493 ZZOC þ :0531 ZZHC À 0:4124 ZZOC LHVðkJ=kgÞ ¼ HHV À hfg 9H M þ 100 100 jGT ¼ W_ GT _ _ ÀEx Ex _ _ _ _ Ex D;CC ¼ Ex4 þ Exb1 À Ex5 Combustion chamber _ _ jGT ¼ Ex5_ÀEx4 Exb1 _ _ _ _ Ex D;gasif ¼ Exbiomass þ Exair À Exb1 Gasifier (21) _ _ jgasif ¼ Ex5_ÀEx4 Exb1 _ D;DHW ¼ Ex _ À Ex _ þ Ex _ _ Ex W1 À ExW2 Domestic hot water Here ZC, ZH and ZO are the mass elements of carbon, hydrogen and oxygen in biomass For the wood with the given chemical formula and the above equation, higher heating value of the fuel 19,980 kJ/kg is obtained Also, the lower heating value of biomass can be calculated in the following equation and given that hfg ¼ 2258 kJ/kg [18]  Ex3 ÀEx2 _ _ _ _ Ex D;GT ¼ Ex3 À W GT À Ex4 Gas turbine (20) _ jHE ¼ Ex_ 5a ÀEx _ HHVðkJ=kgÞ ¼ 349:1C þ 1178:3H þ 100:5S À 103:4O À 15:1N À 21:1ASH _ _ Ex1 jcomp ¼ Ex2 À _ (19) Ex6 ÀEx7 _ _ _ _ D;pmp ¼ Ex Ex 1R À Ex2R þ W pmp Organic pump W pump _ D;eva ¼ Ex _ _ _ _ Ex 5b À Ex5c þ Ex2R À Ex3R Organic evaporator _ Working fluid selection The organic Rankine cycle (ORC) has the principles of the steam Rankine cycle, but uses organic fluid with lower boiling point to recover energy from a lower temperature heat sources The working fluids play an important role in the performance of organic cycle The organic fluid selection directly affects the efficiency of the system, operating parameters, environmental impacts, and economic factors There are several studies conducted by different working fluids (e.g Ammonia [19], R11 and R134a [20], and R152a [21]) depending on a low-grade temperature energy source, availability and material limitation Concerning the heat source temperature and the lower pressure of organic Rankine cycle (condenser pressure) five types of organic fluid selected for organic cycle Table shows some properties of these fluids and performance parameters of system for mentioned organic fluids Also, Fig show the TeS diagram for these four organic working fluids In addition, two bounds temperature for heat source temperature (Tmax) and cold temperature (Tmin) is illustrated in this figure As shown in Table the exergy efficiency of system for R123, show a higher value Furthermore, the higher value of critical temperature offers a distinct advantage over other working fluids R123 with a low life cycle in the atmosphere dose not contributes to the greenhouse gas effect responsible for global warming as GWP index indicate too In addition, the value of ozone depletion ratio for R123 is a reasonable value Following the International regulations (Kyoto and Montreal Protocols), and regards to the above mentioned characteristics of working fluids the R123 is used as organic working fluid in this study _ 3R ÀEx2R jpump ¼ Ex _ _ Ex5b ÀEx5c _ _ _ _ D;tur ¼ Ex Ex 3R À Ex4R þ W tur jtur ¼ (22) where H is the percent of hydrogen and M is the percent of moisture in biomass fuel In order to accurate evaluation of the system and obtain the parameters, which play critical roles in the performance, exergy loss calculation and exergy efficiency of each component is necessary Table shows exergy efficiencies and exergy losses in the components of the cycle under study _ _ jpump ¼ Ex2R_ ÀEx1R Organic turbine  _ _ W1 jDHW ¼ Ex_W2 ÀEx _ W_ tur _ 4R _ 3R ÀEx Ex _ _ _ _ _ Ex D;cond ¼ Ex4R À Ex1R þ ExC1 À ExC2 Organic condenser jtur ¼ _ 1R _ 4R ÀEx Ex _ C2 _ C1 ÀEx Ex Group method of data handling (GMDH) According to literature, there has been ample research conducted on optimization using evolutionary method tools for system identification Among these methodologies, the Group Method of Data Handling (GMDH) has proven itself as a self-organizing approach by which complicated models are generated based on the evolution of their performances In this paper, groups of 2500 data series are selected for the training and test purpose, from which 1500 are used for training while the remaining 1000 data are merely used for the model evaluation The obtained polynomial models are then used in a Pareto based multi-objective optimization approach to determine the best possible combination of exergy efficiency (j) and total cost rate (C_ ) of the system, known as the Pareto front total Optimization 5.1 The definition of objective functions Two objective functions in multi objective optimization considered in this work are exergy efficiency of the combined system (to be maximized) and the total cost rate of combined system (to be minimized) The objective functions in this study can be written as follows: j¼ _ _ _ Ex Q ;domestic þ Wnet;ORC þ Wnet;GT _ Ex (23) biomass C_ total ¼ Z_ total þ C_ biomass (24) Z_ total ¼ Z_ Comp þ Z_ GT þ Z_ AP þ Z_ CC þ Z_ DHW þ Z_ G þ Z_ Pump;R þ Z_ Ev;R þ Z_ Tur;R þ Z_ cond;R (25) S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 853 Table Thermodynamic properties and some characteristics of organic fluids [22,23] Working fluid Molecular weight Critical temperature (K) Critical pressure (MPa) GWPa ODPb Second law efficiency of system (%) Output work of ORC (kW) R123 R600 R245fa R11 R141b 152.93 58.12 134.05 137.37 116.95 456.83 425.13 427.2 425.12 479.96 3.66 3.8 3.64 4.408 4.46 120 725 950 4600 700 0.012 0.12 0.086 12.98 12.96 11.8 12.72 11.85 256.6 254.3 235 242.4 236 a b GWP: Global Warming Potential (GWP) for 100 years integration ODP: Ozone Depletion Potential, relative to R11 In addition, it is assumed that the cost of wood biomass and transportation are 40 $/ton 5.2 Decision variables Given the performance data of the modeled system and the design process of the system under study, seven variables influencing the system performance are taken into account based on previous investigator results [8e10] These parameters include biomass gasification temperature (Tgasif), combustion temperature (Tcomb), inlet gas turbine temperature (T3), gas turbine isentropic efficiency (hGT), compressor isentropic efficiency (hcomp) and compressor pressure ration (rp) and maximum organic Rankine cycle performance pressure (P3R) as decision variables Table shows reasonable variations interval for the above parameters Fig TeS diagram for organic working fluids 5.3 Evolutionary genetic algorithm Several varieties of methods are proposed to calculate purchase equipment cost in terms of design parameters Here, the functions used by Bejan et al [24], Ahmadi [25], Soltani et al [10] and Khanmohammadi et al [26] and the variations corresponding to local conditions and Iran interest rate are applied Z CRF4 Z_ K ¼ K N Â 3600 (26) Here ZK is the purchase cost of each component which is presented in the Appendix A, CRF is capital recovery factor, N is the annual function hour per component, and is operation and maintenance factor which is regarded usually as 1.06 [16] The capital recovery factor has a relationship with interest rate and operation years as follows: CRF ¼ ið1 þ iÞn ð1 À iÞn À (27) where i is interest rate and n is function year Table shows the required parameters for the calculations relevant to purchase equipment cost and economic factors Biomass fuel cost calculation is mainly dependent upon the type of raw material, and collection and processing methods For instance, forest waste has a higher purchase cost and a lower processing cost On the contrary, industrial and municipal waste has a much lower and even negative cost; but a higher processing cost Collection method and transportation distance of such material also affect the finished cost The overall fuel cost as a function of internal energy can be written as follows [27]:  biomass cost ¼ Genetic algorithm as a repetitive algorithm with random search strategy and biological evolution modeling attempts to find optimal solutions [28] The main feature of evolutionary algorithms is a population in which individuals are a series of design parameters and decision variables and the optimal solution is found among them [29] More detail about genetic algorithm and multi objective optimization can be found in Refs [30e33]    cost=ton 3:6 Â 1000 LHV (28) Results and discussion 6.1 The model validation Thermodynamic modeling of syngas production through biomass gasification is the most important part of the modeling of the system under study To validate the modified equilibrium thermodynamic model, the results were compared to those of other studies It should be noted that to make the results and modeling more accurate, the modified equilibrium thermodynamic model was used in this study, i.e by multiplying variable coefficients to equilibrium constants and minimizing the error root mean square of the model and the experimental results to enhance the accuracy of preceding models [34] It should be mentioned that a and b are two constants applied to equilibrium constants to enhance the model precision Table Economic factors Economic parameters Value Interest rate (%) Function year (Year) Operation and maintenance coefficient Hours of the system function annually (Hour) Biomass fuel higher heating value (kJ/kg) 12 20 1.06 8000 19,980 854 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 Table Decision variables and their reasonable range Table Parameter values resulting from exergy and energy analysis of the system Restriction Cause Parameters Values 950 K < Tgasif < 1150 K 1300 K < Tcomb < 1450 K 1250 K < T3 < 1350 K 0.78 < hcomp < 0.89 0.78 < hGT < 0.91 < rp < 11 800 < P3R < 1200 Thermodynamic limitation Metallurgical limitation Heat transfer limitation in heat exchanger Cost limitation Cost limitation Cost limitation Thermodynamic limitation _ net (kW) Net Power output, W Exergy efficiency of system, j (%) Energy efficiency of system, h (%) _ D;tot (kW) Total exergy destruction rate, Ex Heating load, Q_ (kW) 16.13 24.15 13,357 _ DWH (kg/s) Hot water mass flow rate, m 21.9 1961.3 2569 DWH 47.0% aK1 ¼ x5 x21 (29) bK2 ¼ x3 x1 x2 x4 (30) 29.8% The results indicate that in terms of the values a ¼ 2.89 and b ¼ 1, the model has a good consistency with previous works The 11.5% compositions are shown in Fig [35,36] 6.8% 1.3% 2.2% 0.6% 0.1% 0.3% 0.4% 6.2 The results of exergy and economic analysis The results of thermodynamic analysis are presented here Table shows the main output of the system for the initial performance parameters To find the locations where the main exergy destruction take place, for each component the exergy destruction rate is calculated Fig illustrates the percent of exergy destruction for the components of the studied system The results indicate that the maximum exergy destruction rate is related to gasifier, combustion chamber, organic Rankine cycle evaporator, and domestic hot water heat exchanger The main reason of exergy destruction in gasifier and combustion chamber is the presence of a high temperature difference between flows entering and exiting such components, which enhance the intensity of irreversibility in these components On the other hand, in organic Rankine cycle evaporator, as high temperature stream (combustion products) transfers its heat to organic working fluid, it could be said that high quality energy converts into low quality energy and this is the main reason of high rate of exergy destruction in such component Similarly, domestic hot water generator allocates a main part of the system exergy loss to itself 60 50 Fig The percent of exergy loss for each component of the cycle In addition, Table shows the exergy efficiency of each components of the cycle Fig show the exergy and energy efficiency for three modes of the system As it can be seen, the exergy and energy efficiency in the combined heat and power mode has the highest value because a larger part of primary energy converts to useful products In this case, the gas turbine output is 1669 kW; the ORC output is 292.3 kW and domestic water heater produces 2569 kW hot water It can be found that the energy efficiency in the combined heat and power mode is higher than exergy efficiency for the same case Since the exergy of produced hot water is lower than its energy for a determined mass flow rate and temperature, the energy efficiency is more than exergy efficiency in combined heat and power mode The results of the economic analysis of the system under study are shown in Table The cost of each component is compared to the equations of different references and is given in the Appendix A Present Study Experimantal (Alaudin Z.A.[36]) Percent (%) 40 30 Experimental (Jayah T.H.[37]) Zainal model [16] 20 10 Fig A comparison of the present study results with experimental results and previous research Table Exergy efficiency for each component of the cycle in: Tcomb ¼ 1177 (C ), rp ¼ 9, Tgasif ¼ 827 (C ), Moisture content ¼ 0.16, Biomass flow rate ¼ 0.8 kg/ s Component Exergy efficiency (%) Compressor Heat exchanger Gas turbine Combustion chamber Gasifier Domestic hot water Organic pump Organic evaporator Organic turbine Organic condenser 91.4 91.4 97 64.4 61.3 26.6 88.5 23.1 15 60.7 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 855 30 Energy efficiency (%) Exergy efficiency (%) 25 Effeciency (%) 20 15 10 GT GT+ORC GT+ORC+DWH Fig Comparison of energy and exergy efficiency for different types of system 6.3 Optimization results The optimization results of the system based on selected decision variables and objective functions are shown in the Fig This figure shows the optimal point for the system based on the objective functions defined in the equations (22) and (23) It can be seen that the final cost of the system increases steadily with an increase in the system exergy efficiency The results indicate that by an increase in efficiency from 14.5% to 16.5%, the final cost increases from 75 $/h to 77 $/h which is an optimal value However, higher increase in efficiency from 16.5% to 17.9% can exert a higher cost to the system As shown in Fig 6, although the design point C has a maximum efficiency of 17.9%, the system cost rate in this point will reach maximum value of 87 $/h However, design point A has the minimum design cost in which the system cost rate is 75 $/h Therefore, the design point C is the optimal design point when it is regarded as the only objective function of the system efficiency, and the point A is the optimal design point when the cost function is considered as the only objective of the system optimization In general, in multi-objective optimization and Pareto diagram, all points are considered as the optimal solutions of problem, and ultimately system designers and decision makers attempt to select a point as the optimal solution by considering some designing consideration Table presents the value of decision variables in the selected design points A, B and C In order to obtain a diagram through which it is possible to obtain the system cost in terms of exergy efficiency, the Pareto frontier diagram is depicted in Fig Fig The optimized points based on the defined objective functions Table The characteristics of the selected design points A, B, C Optimum point Tcomb (K) rp P3R (kPa) hcomp hGT Tgasif (K) GTIT (K) A B C 1449 1449 1449 800.5 800.5 1171 0.78 0.78 0.78 1114.6 1065.7 987.2 7.08 8.6 9.97 0.9 0.9 0.9 1266 1269.6 1266.4 To predict the system behavior and find a correlation between exergy efficiency and final cost of system a relation derived based on Pareto frontier diagram À817:7h3ex þ 1:464 Â 104 h2ex þ 1722hex þ 132:9 C_ tot ðhex Þ ¼ hex À 56:98h3ex þ 898:6h2ex À 3589hex þ 815:8 (31) As it shown in Fig 7, the optimized values for exergy efficiency on the Pareto frontier valid in the range between 14% and 18% and the equation (31) are valid for the same range Table The results of the economic analysis of the system under study in: Tcomb ¼ 1177 (C ), rp ¼ 9, Tgasif ¼ 827 (C ), Moisture content ¼ 0.16, Biomass flow rate ¼ 0.8 kg/s Component Cost ($) Cost rate ($/h) Biomass fuel (wood) ORC turbine ORC pump ORC condenser ORC evaporator Compressor Gas turbine Heat exchanger Combustion chamber Gasifier Domestic hot water ($/GJ) 341,175 3686 55,103 6969 219,468 164,414 305,161 33,390 332,593 6546 117 6.05 0.065 0.97 0.12 3.89 2.91 5.41 0.59 5.9 0.11 Fig The Pareto frontier diagram: the optimal approximations for the objective functions 856 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 6.4.2 Combustion temperature One of the most significant design parameters in this study is combustion temperature, which directly affects gas turbine performance and organic Rankine cycle Fig shows the behavior of objective functions with variations of this parameter Based on the behavior of the above diagram for the selected points, it could be inferred that an increase in the combustion temperature leads to an increase in the exergy efficiency of the studied system and has a positive economic impact on the system cost reduction With a close analysis of such variations, it could be seen that by an increment in the combustion temperature, the cost of hightemperature heat exchanger, which plays significant roles in the system cost, reduces significantly In addition, considering the cost function of the high temperature heat exchanger, it could be seen that the cost of heat exchanger reduces as combustion temperature increases due to the increased logarithm mean temperature difference Therefore, the system overall cost will be decreased It must be noted that even though increased combustion temperature improve both objective functions, metallurgical and physical Fig The impacts of gasification temperature variation from 950 K to 1150 K on the system objective functions in the optimized points A, B and C 6.4 Sensitivity analysis In order to better understand the system behavior and the impact of the decision variables on the thermodynamic and economic performance of studied system, in the optimal points A, B and C, sensitivity analysis is extracted on these variables 6.4.1 Gasification temperature The diagram in Fig indicates that by an increase in gasification temperature, the overall cost as well as the system exergy efficiency will be reduced As it can be seen from the results, in the design point C, with a decrement in the gasification temperature the exergy efficiency has no sensitive change while the system cost rate experiences a severe increment This fact reveals that by selecting the point C as the design point, changing the gasification temperature, as a parameter for enhancing efficiency is not cost-effective and therefore the points A and B show a more reasonable behavior from cost rate point of view Fig The effects of combustion temperature variation from 1300 K to 1450 K on the objective functions in the optimized points A, B, and C Fig 10 The effects of the parameters variation (a) the compressor isentropic efficiency from 0.78 to 0.89 (b) the gas turbine isentropic efficiency from 0.78 to 0.91 in the optimized points A, B and C on objective functions S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 857 limitations allows increase in combustion temperature to a limited extent [37] 6.4.3 Isentropic efficiency of compressor and gas turbine Fig 10 shows the effect of changes in the efficiency of isentropic compressor and turbine efficiencies on the objective functions An Increment in the compressor isentropic efficiency and gas turbine isentropic efficiency has a different effect on the objective functions Fig 10(a) shows that in the optimal points, more increase in isentropic efficiency leads to a higher cost and higher exergy efficiency for the system The results indicate that the higher isentropic efficiency of compressor means reduced work exerted on compressor, and in turn, an increase in the system exergy efficiency On the other hand, this effect can increase the final cost of compressor, and by keeping fuel cost and purchase equipments cost constant, the system total cost rate will be increased In addition, results indicate that an increase in isentropic efficiency of gas turbine can both positively affect the system total exergy efficiency and final cost rate of system Increased output working of the system due to an increase in isentropic efficiency is one main reason for the enhancement of the system thermodynamic performance Moreover, although increase in turbine isentropic efficiency from 87 to 91% leads to an increase in gas turbine purchase cost, decrease in fuel cost in output constant power can reduce total cost rate, which the results of the Fig 10(b) refers to this issue 6.4.4 Compressor pressure ratio The diagram in Fig 11 shows the impact of the compressor pressure ratio on two objective functions in the selected optimal points As it could be seen, for a higher-pressure ratios, exergy efficiency is high and the system overall cost increases It can be found that with an increment in the compressor pressure ratio the outlet compressor temperature will be increased which resulted in a reduction of heat transfer from hot stream (combustion products) to cold stream (air) Consequently, a slight reduction in heat exchanger purchase cost, and increase in the price of some installations such as compressor and gas turbine lead to the increase Fig 11 The effects of the compressor pressure ratio variation from to 11 on objective functions in the optimized points A, B and C Fig 12 The effects of the inlet gas turbine temperature variation from 1250 K to 1350 K on objective functions in the optimized points A, B and C of overall cost of system In addition, it could be inferred that in the design point C, by an increase in exergy efficiency, the total cost has a drastic increase 6.4.5 Gas turbine inlet temperature Fig 12 shows the effects of variation in gas turbine inlet temperature parameter on two objective functions The results indicate that an increase in this parameter can affect the system performance to a limited extent and improve both objective functions By a closer look at the gas turbine purchase cost equation, an increment in gas turbine inlet temperature can increase gas turbine purchase cost, however, it can significantly reduce high temperature heat exchanger purchase cost, which in turn decreases overall cost It must be noted that considering the limited variation range of this parameter in Fig 12 and the designing limitations of the desired cycle, the parameter cannot be regarded as an influencing parameter for efficiency increase Fig 13 The effects of the maximum pressure of the organic Rankine cycle variation from 800 kPa to 1200 kPa on objective functions in the optimized points A, B and C 858 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 6.4.6 Maximum pressure of organic Rankine cycle Two main variables influencing the organic Rankine cycle are the type of organic fluid and maximum organic fluid temperature The variation in the maximum organic Rankine cycle pressure, which follows the maximum cycle temperature, is shown in the Fig 13 Concerning the fact that the working fluid critical temperature is 456.8 K, the maximum pressure variations interval of organic Rankine cycle is considered from 800 kPa to 1200 kPa The results indicate that by an increment in the maximum pressure of organic Rankine cycle, the power output of organic Rankine cycle will be increased, which in turn, it increases the overall cycle efficiency Of course, it must be noted that by an increase in the cycle pressure, more work is consumed in pump However, a higher increase will be occurred in organic cycle turbine, and these can lead to an increase in working of the organic cycle On the other hand, an escalation in the maximum cycle pressure due to an increase in organic Rankine purchase cost and lack of variation in purchase cost of other components can lead to an increase in the overall system cost rate Appendix A Cost function for system elements [16,24,25,38] Air compressor : C11  ZCC ¼  The system efficiency based on the lower heating value of the wood in the initial designing state was 15.6%, which this efficiency could be improved to 17.9% in the optimal state, regardless of the cost objective function  The optimization results indicate that the final system cost could be reduced to 75 $/h, regardless of the exergy efficiency as an objective function  The system sensitivity analysis in the optimal points A, B and C shows that reduction in gasification temperature in the determined interval can positively affect efficiency, and can steadily increase the system costs  An increase in compressor isentropic efficiency in selected optimal points leads to a drastic increase in total cost of system as well as a mild increase in exergy efficiency of system Finally, it can be concluded that variegation each decision variables in reasonable range has different effects on exergy efficiency and total cost of system Selecting the optimal point and considering the effect of variation performance parameters in optimal point is one of important issue which should be considered in an energy system design Acknowledgement I would like to acknowledge National Iranian Gas Company (NIGC) for their helpful support (Gr No 930201)  _a C21 m C22 À 0:98 Âð1 þ expðC32 Tcomb À C24 ÞÞ Combustion chamber : C21 ¼ 46:08; C22 ¼ 0:995; C23 ¼ 0:018; C24 ¼ 26:4  Gas turbine : ZGT ¼    _g C31 m P ln ð1 þ expðC33 T3 À C34 ÞÞ C32 À hGT P3 C31 ¼ 479:34; C32 ¼ 0:92; C33 ¼ 0:036; C34 ¼ 54:4  Conclusion In the present study, a comprehensive thermodynamic and economic modeling for an externally fired combined system integrated with Syngas produced from biomass (wood) as a prime mover is presented The system exergy analysis results indicated that gasifier, combustion chamber and organic Rankine cycle have the maximum exergy destruction rate in the system under study In addition, organic turbine, organic evaporator and hot water generator for domestic use are the most ineffective components of a system with 15%, 23.1% and 26.6%exergy efficiency, respectively Other study results are as follows:  À Á C11 rp ln rp C12 À hsc   C12 ¼ 0:9 ¼ 71:1 $ kgsÀ1  ZC ¼ ZAP ¼ C41 Air preheater :  _ ðh5 À h6 Þ 0:6 m UDTLM U ¼ 6; C41 ¼ 4122 Gasifier : _ biomass Þ0:67 ZG ¼ 1600ð3600 Â m Domestic hot water heater : ORC evaporator : _ DHW ZDHW ¼ 0:3m ZEv;R ¼ 309:14ðAEv Þ0:85 ORC pump :  0:65 _ Pump ZPump;R ¼ 200 W ORC turbine : 0:75  _ tur ZTur;R ¼ 4750 W ORC condenser : ZCond;R ¼ 516:62ðACondnser Þ0:6 References [1] M.A Rosen, I Dincer, On exergy and environmental impact, Int J Energy Res 21 (1997) 643e654 [2] P Ahmadi, M.A Rosen, I Dincer, Greenhouse gas emission and exergoenvironmental analyses of a trigeneration energy system, Int J Greenh Gas Control (2011) 1540e1549 [3] Y Sanjay, O Singh, B Prasad, Energy and exergy analysis of steam cooled reheat gasesteam combined cycle, Appl Therm Eng 27 (2007) 2779e2790 [4] S.B Ferreira, P Pilidis, Comparison of externally fired and internal combustion gas turbines using biomass fuel, J Energy Resour Technol 123 (2001) 291e296 [5] A Datta, R Ganguly, L Sarkar, Energy and exergy analyses of an externally fired gas turbine (EFGT) cycle integrated with biomass gasifier for distributed power generation, Energy 35 (2010) 341e350 [6] M.P Arnavat, J.C Bruno, A Coronas, Modeling of trigeneration configurations based on biomass gasification and comparison of performance, Appl Energy 114 (2014) 845e856 [7] P Ahmadi, I Dincer, M.A Rosen, Thermoeconomic multi-objective optimization of a novel biomass-based integrated energy system, Energy 68 (2014) 958e970 [8] S Soltani, S Mahmoudi, M Yari, M.A Rosen, Thermodynamic analyses of an externally fired gas turbine combined cycle integrated with a biomass gasification plant, Energy Convers Manag 70 (2013) 107e115 S Khanmohammadi et al / Applied Thermal Engineering 91 (2015) 848e859 [9] S Soltani, S Mahmoudi, M Yari, M.A Rosen, Thermodynamic analyses of a biomass integrated fired combined cycle, Appl Therm Eng 59 (2013) 60e68 [10] S Soltani, S Mahmoudi, M Yari, T Morosuk, M.A Rosen, V Zare, A comparative exergoeconomic analysis of two biomass and co-firing combined power plants, Energy Convers Manag 76 (2013) 83e91 [11] P Ahmadi, I Dincer, M.A Rosen, Thermodynamic modeling and multiobjective evolutionary-based optimization of a new multigeneration energy system, Energy Convers Manag 76 (2013) 282e300 [12] P Ahmadi, I Dincer, M.A Rosen, Exergo-environmental analysis of an integrated organic Rankine cycle for trigeneration, Energy Convers Manag 64 (2012) 447e453 [13] S Khanmohammadi, A.R Azimian, S Khanmohammadi, Exergy and exergoeconomic evaluation of Isfahan steam power plant, Int J Exergy 12 (2013) 249e272 [14] V Zare, M Yari, S.M.S Mahmoudi, Proposal and analysis of a new combined cogeneration system based on the GT-MHR cycle, Desalination 286 (2012) 417e428 [15] Z Zainal, R Ali, C Lean, K Seetharamu, Prediction of performance of a downdraft gasifier using equilibrium modeling for different biomass materials, Energy Convers Manag 42 (2001) 1499e1515 [16] A.G Abuadala, Investigation of Sustainable Hydrogen Production from Steam Biomass Gasification (PhD thesis), Mechanical Engineering Department, University Ontario Institute Technology (UOIT), Oshawa, Canada, 2010 [17] T.J Kotas, The Exergy Method of Thermal Plant Analysis, Butterworth, London, 1985 [18] P Basu, Biomass Gasification and Pyrolysis: Practical Design and Theory, Academic Press, Burlington, 2010 [19] P Ahmadi, I Dincer, M.A Rosen, Energy and exergy analyses of hydrogen production via solar-boosted ocean thermal energy conversion and PEM electrolysis, Int J Hydrogen Energy 38 (2013) 1795e1805 [20] C Zhang, G Shu, H Tian, H Wei, X Liang, Comparative study of alternative ORC-based combined power systems to exploit high temperature waste heat, Energy Convers Manag 89 (2015) 541e554 [21] J Wolpert, S Riffat, Solar-powered Rankine system for domestic applications, Appl Therm Eng 16 (1996) 281e289 [22] T Handayani, A Harvey, J Dalton, D Reay, Selection of the optimum working fluids in organic Rankine cycles using TOPSIS, Chem Eng Trans 29 (2012) 139e144 [23] H Chen, D.Y Goswami, E.K Stefanakos, A review of thermodynamic cycles and working fluids for the conversion of low-grade heat, Renew Sustain Energy Rev 14 (2010) 3059e3067 [24] A Bejan, M.J Moran, Thermal Design and Optimization, John Wiley & Sons, 1996 [25] P Ahmadi, Modeling, Analysis and Optimization of Integrated Energy Systems for Multigeneration Purposes (PhD thesis), Mechanical Engineering Department, University Ontario Institute Technology (UOIT), Oshawa, Canada, 2013 [26] S Khanmohammadi, A.R Azimian, Exergoeconomic evaluation of a twopressure level fired combined-cycle power plant, J Energy Eng (2013), http://dx.doi.org/10.1061/(ASCE)EY.1943-7897.0000152 859 [27] Z Lian, K Chua, S Chou, A thermoeconomic analysis of biomass energy for trigeneration, Appl Energy 87 (2010) 84e95 [28] K Deb, A Pratap, S Agarwal, T Meyarivan, A fast and elitist multiobjective genetic algorithm: NSGA-II, Evol Comput IEEE Trans (2002) 182e197 [29] N Srinivas, K Deb, Multiobjective optimization using nondominated sorting in genetic algorithms, Evol Comput (1994) 221e248 [30] K Atashkari, N Nariman-Zadeh, A Pilechi, A Jamali, X Yao, Thermodynamic Pareto optimization of turbojet engines using multi-objective genetic algorithms, Int J Therm Sci 44 (2005) 1061e1071 [31] E Zitzler, K Deb, L Thiele, Comparison of multiobjective evolutionary algorithms: empirical results, Evol Comput (2000) 173e195 €lcü, A Khalkhali, A Jamali, Modelling [32] K Atashkari, N Nariman-Zadeh, N Go and multi-objective optimization of a variable valve-timing spark-ignition engine using polynomial neural networks and evolutionary algorithms, Energy Convers Manag 48 (2007) 1029e1041 [33] N Nariman-Zadeh, K Atashkari, A Jamali, A Pilechi, A Yao, Inverse modelling of multi-objective thermodynamically optimized turbojet engines using GMDH-type neural networks and evolutionary algorithms, Eng Optim 37 (2005) 437e462 [34] N.S Barman, S Ghosh, S De, Gasification of biomass in a fixed bed downdraft gasifiereA realistic model including tar, Bioresour Technol 107 (2012) 505e511 [35] Z.A Alauddin, Performance and Characteristic of a Biomass Gasifier System (PhD thesis), University of Wales, UK, 1996 [36] T Jayah, L Aye, L Fuller, T Stewart, Computer simulation of a downdraft wood gasifier for tea drying, Biomass Bioenergy 25 (2003) 459e469 [37] A Cihan, O Hacıhafızoglu, K Kahveci, Energyeexergy analysis and modernization suggestions for a combined-cycle power plant, Int J Energy Res 30 (2006) 115e126 [38] M.R Meigounpoory, P Ahmadi, A.R Ghaffarizadeh, S Khanmohammadi, Optimization of combined cycle power plant using sequential quadratic programming, in: Heat Transfer Summer Conference Collocated with the Fluids Engineering, Energy Sustainability, and 3rd Energy Nanotechnology Conferences, American Society of Mechanical Engineers, 2008, pp 109e114 [39] S Khanmohammadi, K Atashkari, R Kouhikamali, Performance assessment and multi-objective optimization of a trrigeneration system with a modified biomass gasification model, Modares Mech Eng 15 (9) 209e222 [40] S Khanmohammadi, P Ahmadi, K Atashkari, R Kouhikamali, Design and optimization of an integrated system to recover energy from a gas pressure reduction station Progress in Clean Energy Analysis and Modeling, vol pp 89e108 [41] P Ahmadi, I Dincer, Thermodynamic and exergoenvironmental analyses, and multi-objective optimization of a gas turbine power plant, Appl Therm Eng 31(14), 2529e2540

Ngày đăng: 01/08/2016, 09:30

Từ khóa liên quan

Mục lục

  • Exergoeconomic multi-objective optimization of an externally fired gas turbine integrated with a biomass gasifier

    • 1. Introduction

    • 2. System modeling

      • 2.1. Thermodynamic model

        • 2.1.1. Gasifier

        • 2.1.2. Combustion chamber

        • 2.1.3. Ceramic heat exchanger

        • 2.2. Exergy analysis

        • 3. Working fluid selection

        • 4. Group method of data handling (GMDH)

        • 5. Optimization

          • 5.1. The definition of objective functions

          • 5.2. Decision variables

          • 5.3. Evolutionary genetic algorithm

          • 6. Results and discussion

            • 6.1. The model validation

            • 6.2. The results of exergy and economic analysis

            • 6.3. Optimization results

            • 6.4. Sensitivity analysis

              • 6.4.1. Gasification temperature

              • 6.4.2. Combustion temperature

              • 6.4.3. Isentropic efficiency of compressor and gas turbine

              • 6.4.4. Compressor pressure ratio

              • 6.4.5. Gas turbine inlet temperature

              • 6.4.6. Maximum pressure of organic Rankine cycle

              • 7. Conclusion

Tài liệu cùng người dùng

Tài liệu liên quan