1. Trang chủ
  2. » Luận Văn - Báo Cáo

Image Quality

34 167 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 34
Dung lượng 1,25 MB

Nội dung

CT Basic training : I.Q Image Quality GOLD LITE PTE LTD CT Basic training : I.Q Image Quality Image Quality Image Quality • Image quality is subjective • We can measure the quality of a system and express it in a technical way Image Quality GOLD LITE PTE LTD Image Quality CT Basic training : I.Q Image Quality Description High contrast resolution • The ability to see the smallest detail with more than 100H contrast differences • “x” mm = 10 / (2 x “y” lp/cm) (convert from ‘mm’ to ‘lp/cm’ or v.v.) • Influences on High contrast: – – – – L/R alignment vibration reconstruction filter focus size GOLD LITE PTE LTD Visual High Contrast CT Basic training : I.Q Image Quality Description Low contrast resolution • The ability to see the smallest contrast differences • “mm” x “%” = “low contrast factor” (on a contrast scale of 1000 H) 0.3% 0.1% 0.5% • Influences on Low contrast: – – – – – F/B alignment tube output (mA, kV, slice thickness) vibration reconstruction filter calibration GOLD LITE PTE LTD 1.0% Visual Low Contrast CT Basic training : I.Q Image Quality Description • • • • GOLD LITE PTE LTD Uniformity (Cupping / Capping) Linearity Slice thickness Partial Volume Effect CT Basic training : I.Q Uniformity (Cupping / Capping) • Measure all H-values on a profile in a water phantom Good: all values identical (+/- 2H) • CUPPING: Values on outside higher than in the middle • CAPPING: Values on outside lower than in the middle GOLD LITE PTE LTD CT Basic training : I.Q Linearity • Measure different materials with a known H-value • Plot the known and measured H-value Teflon Delrin Water LDPE Air OK GOLD LITE PTE LTD NOT OK = 970 H = 363 H = 0H = -103 H = -1000 H CT Basic training : I.Q Slice-thickness metal wire x-ray beam α front view side view side view (enlarged) reconstruction (enlarged) reconstruction • Make a scan through a phantom with a tilted metal wire • Measuring the length of the reconstructed wire • Angle α is known, the slice-thickness can be calculated GOLD LITE PTE LTD CT Basic training : I.Q Partial Volume Effect (1/2) pixel image = 2D voxel but the slice-thickness is the 3rd dimension • The H-value we see is the average of the contents of the ‘voxel’ GOLD LITE PTE LTD CT Basic training : I.Q Partial Volume Effect (2/2) If the voxel is homogenous : NO PROBLEM If the voxel is NOT homogenous : The displayed H-value is an average of more tissues Example: A small object cannot been seen Conclusion: If you want to see small objects: use thin slices GOLD LITE PTE LTD CT Basic training : I.Q Multiple Ring artifact (2/2) GOLD LITE PTE LTD CT Basic training : I.Q Streak artifact Caused by a sudden change in the data of channel - by defective detector - bad contact -? t k ac bl 900 GOLD LITE PTE LTD 896 RAW DATA PLOT channels views CT Basic training : I.Q Multiple Streak artifact (1/2) Caused by a many sudden changes in the data of channel - by defective detector - bad contact -? 900 GOLD LITE PTE LTD channels 896 RAW DATA PLOT views CT Basic training : I.Q Multiple Streak artifact (2/2) If the streaks can be connected by a circle, the streaks are caused by channel (Many changes during scan) GOLD LITE PTE LTD CT Basic training : I.Q Fan Streak artifact (1/2) This is a multiple streak artifact where all streaks originate from one point This appears when a complete view is damaged (lost) 900 GOLD LITE PTE LTD channels 896 RAW DATA PLOT views CT Basic training : I.Q Fan Streak artifact (2/2) GOLD LITE PTE LTD CT Basic training : I.Q Moiré pattern artifact This type of artifact can be caused by many fan-streak artifacts -or- interference from outside -or- ?? GOLD LITE PTE LTD CT Basic training : I.Q Multiple vibration artifact This artifact was caused by a spacer Making contact between DAS-assy and gantry-frame GOLD LITE PTE LTD CT Basic training : I.Q Reconstruction artifact GOLD LITE PTE LTD • All raw data is after reconstruction NOT OK • RTRU defect CT Basic training : I.Q Reconstruction artifact GOLD LITE PTE LTD • Bad contact • RTRU out + in = OK CT Basic training : I.Q Center Dot artifact GOLD LITE PTE LTD • Check with same parameters on a SS-phantom • Lower the “a-parameter” and perform air calibration CT Basic training : I.Q Mechanical artifact GOLD LITE PTE LTD • vibration artifacts • solved by adjusting the rotation belt tension CT Basic training : I.Q Black streak (1/2) GOLD LITE PTE LTD • What is the problem ? • black streak artifact (from where?) • from outside the head ! • how to follow-up ? • check scano ! (see next sheet) CT Basic training : I.Q Black streak (2/2) • • • GOLD LITE PTE LTD check scano ! slice is through the band ! inform the user of this problem !! CT Basic training : I.Q Finally • Some artifacts are ‘normal’ - Metal objects - Bone/soft-tissue , bone/air transitions can give problems during reconstruction and cause streak artifacts • This list is far from complete Please send images (+ description) on floppy or via email to us if you encounter interesting artifacts in the field GOLD LITE PTE LTD ... I.Q Image Quality Image Quality Image Quality • Image quality is subjective • We can measure the quality of a system and express it in a technical way Image Quality GOLD LITE PTE LTD Image Quality. .. LITE PTE LTD CT Basic training : I.Q Every step influences the ? ?image quality? ?? and can cause distortions From the HV Generator to the image printer GOLD LITE PTE LTD CT Basic training : I.Q Artifact... reconstruction filter focus size GOLD LITE PTE LTD Visual High Contrast CT Basic training : I.Q Image Quality Description Low contrast resolution • The ability to see the smallest contrast differences

Ngày đăng: 21/01/2016, 00:07

Xem thêm

TỪ KHÓA LIÊN QUAN