Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 40 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
40
Dung lượng
1,19 MB
Nội dung
[...]... control using draw control > High-power factor converter Power supply NFB Accessories MC Inverter FR -A500 Main unit ✕ B Inverter FR -A500 ✕ ✕ ✕ ✕ ✕ Elevation motor ✕ ✕ ✕ ✕ Mechanical brakes Feed roll Drive roll Travel motor IM IM IM IM IM FR -A500 FR -A500 FR -A500 FR -A500 FR -A500 B Fork motor Inverter FR -A500 Ratio setting Power supply B NFB MC G Thanks to the wide-range speed control, high-speed operation... setting Pull-off motor FR -A500 Vinyl bag Materials IM2 Reduction gears MC2 Pressure conveyor Airflow Duct Blower Motor Chill source (chiller) Heat source (heat pump or boiler) Heat exchanger Hot/cold water Air Air filter Reduction gears Reduction gears Wind-up motor Belt Extrusion motor IM1 Air IM PLG FRA500 Inverter Extruder Inverter IM3 Power NFB supply NFB FRA500 MC MC FRA500 Inverter MC NFB Frequency... with two mounting screws on the bottom of the inverter and at two places on the bottom of the FR-A5FN Mounting adapter attachment FR-A5AT This attachment allows FR -A500 series models to be mounted using the same holes as those used for FR-A200E series models, greatly facilitating the task of replacing earlier models 11K~15K, 30K~55K models in the 200V class, and 11K~15K models in the 400V do not require... has been designed to cope with the high frequency components generated by the inverter, and can cope with high frequencies and surges Power factor improvement AC reactor(FR-BAL) All models in the FR -A500 series from 0.4kW~55kW (200V,400V) are equipped with a terminal for connecting the FR-BEL DC reactor The FR-BEL is a compact, lightweight DC reactor which delivers greater efficiency in input power... pressed continuously for approximately 1.5 seconds, the current display switches to the initial power ON display Copying Parameters Parameter settings can be copied to another inverter (excluding non-FR -A500 series inverters) by using the FR-DU04 operation panel or the FR-PU04 parameter unit First, all of the parameters on the source inverter are read, the operation panel is connected to the target inverter,... supplies for the control panel and the parameter unit Please do no use them during communications via the RS-485 interface 13 3.75 (0.15) 40 (1.57) units: mm (inch) Terminal Connection Diagram Inverter FR -A500 NFB Motor MC R S T 3-phase AC power supply U PU connector (RS-485) IM V W (Note 8) R1 S1 Short bar (Note10) 24 VDC power supply and external transistor common Short bar (Note 3) Grounding Power factor... analog form Relay output FR-A5AR Outputs the inverter main unit's standard output signal at the relay contact Orientation control, PLG feedback control FR-A5AP Expansion analog output Built-in options (FR -A500 only) Applicable inverter A digital signal of BCD or binary code used for setting the inverter's frequency Common to all units In combination with a pulse encoder, can halt the main axis at the home... the size of a completely sealed housing plate Notes 1 When mounting, use mounting attachment FR-A5CN (sold separately) (for models 1.5K~55K) 2 The fin height is greater than the height of the FR-A200 series Model FR-A5CN01 FR-A5CN02 FR-A5CN03 FR-A5CN04 Compatible 200V class FR-A520-1.5~3.7K FR-A520-5.5K/7.5K FR-A520-11K FR-A520-15K~22K FR-A5CN mounting hardware** (option) Inside housing plate Inverter... Each phase should be wound at least 3 times (4T, 4 turns) in the same direction (The greater the number of turns, the more efficient.) 2 When the thickness of the wire prevents winding, use at least 4 in series and ensure that the current passes through each phase in the same direction 3 Can be used on the output side in the same way as the input side On the output side, the number of turns should be less... External box H H W D W D Reactors 1,2 190 320 165 H W 270 450 D 203 34 FR-HC High-power Factor Converters FR-RC Power Regenerating Converters I External Dimensions MC1 MC2 Reactor 1 (FR-HCL01) Inverter (FR -A500) High-power factor converter (FR-HC) External box (FR-HCB) Resistor R Reactor 2 (FR-HCL02) S T NFB MC R3 R2 R2 S S2 T T2 S2 MC S3 T3 T2 R3 R4 R4 P P S3 S4 S4 N N T3 T4 T4 RDY MRS RSO R Power Supply . Profibus DP CC-Link Modbus plus Device Net CE UL cUL VARIABLE FREQUENCY DRIVES A500 SERIES ADVANCED INTELLIGENT CONTROL A500. A4 01.10.13 6:40 PM Page 3 The Culmination of Mitsubishi’s Expertise Reaches. into the Realms of Advanced Technology Expanding the Potential of Inverters Announcing the FR -A500 Series, a new line of advanced inverters that combines Mitsubishi Electric’s original technology. aspects of advanced technology to equip this series with performance of the highest order. With their astonishing top-level specifications, this new series opens up an entirely new area of potential