tài liệu cataloge Mitsubishi pot

20 294 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 20
Dung lượng 3,06 MB

Nội dung

ELECTRONIC MULTI-MEASURING INSTRUMENT — Best solution for energy measurement — Mitsubishi Electric Corporation's Fukuyama Works, which produces these products, is certified as meeting the ISO 14001 environmental management system standard. — Best solution for energy measurement — Mitsubishi Electronic Multi-measuring instrument New-S series features high performance and crystal clear display, supporting your measuring and monitoring systems. Monitoring Display Output Communication Operation High accuracy monitoring functions by our dedicated ASIC Easy to read display functions Wide range of output functions from measuring data to alarm Communication functions to support open networks “High-tech, yet simple” operating functions Contents N Overview & Features N Specifications N Operating instructions N Outline dimensions/wiring diagrams N Safety precautions N Service network 1 5 7 15 18 L Upper/lower limit monitoring up to 4 items LHarmonics monitoring LMeasuring import/export active energy L4 items displayable LBacklight automatic off function LOutput functions for 6 items LPulse width settable LPulse output at 2 points (ME110NSR-4A2P) LAnalog output range settable LCC-Link communication LModBus communication LSimple settings L Simple operations Cost performance L Save space and reduce connection wires L Economically replaces the following instruments with one ME110NSR-4APH ME110NSR-4APH V indicator Active energy W indicator VT CT PF indicator W transducer V transducer PF transducer A transducer A indicator Visible display Bar graph : Power factor Upper Middle Lower : Current : Power : Voltage L The bar graph indicator makes it possible to read easily. L 4 measurement items appear on one display. 3 items in digital figures and 1 item by a bar graph. L Large size of digital figures. L Clear display with backlight. The backlight can be automatically turned off by setting. Cyclic display change L Display/phase automatically changes every 5 seconds. Display example Display for 5 seconds Display for 5 seconds Press for 2 seconds. Display for 5 seconds Display for 5 seconds DISPLAY Product line-up Model name ME110NSR ME110NSR-4A2P ME110NSR-4APH ME110NSR-C ME110NSR-MB Measurement elements A 3 DA 3 V 3 W, DW cosI var, Hz Wh, varh HI, HV Phase wire system Output / communication functions 3P3W/1P2W 1P3W 3P4W Analog output Pulse output Alarm output Communication (4 circuits) (4 circuits) (1 point) (1 point) (2 points) CC-Link ModBus First 3 digits can be set at your choice from 200 V to 550 kV. In our previous S series, the primary voltage was set at the factory before shipping. Now, the primary voltage can be set at your side. Additionally, the primary current can be set from 5 to 30 kA without the limit of total power load. Applicable to special VT Maximum 4 points of upper/lower limit monitoring ● 2 kinds of active energy & 4 kinds of reactive energy measurable · Active energy………Imported/exported · Reactive energy……Imported lag/lead, Exported lag/lead ● Pulse output at 2 points possible (ME110NSR-4A2P) · Output of same elements  2 points & different elements  1 point each Improved measurement of active/reactive energy ME110SR ME110SR-4APH ME110SR-4A2P ME110SR-C ME110SR-MB 0 1 0 4 4 ME110NSR ME110NSR-4APH ME110NSR-4A2P ME110NSR-C ME110NSR-MB 4 4 4 4 4 Previous S series Monitoring points New-S series Monitoring points Harmonics monitoring possible with one unit Harmonic voltage total distortion Harmonic current total effective value ● Display & output of measurement elements at a receiving point possible with one unit. · Simultaneous output of 4 circuit analog output, 1 point pulse output & 1 point alarm output (ME110NSR-4APH). ● Optional elements can be output regardless of the displayed elements. · For analog & pulse outputs, any selected elements can be output regardless of the displayed elements at LCD screen. ● 4 analog outputs & 2 point pulse outputs possible (ME110NSR-4A2P) Voltage upper alarm Voltage lower alarm Current upper alarm Current lower alarm pulse output Note : Only 3P3W/1P3W/1P2W spec, support this function. pulse output VT VT CT VT CT 6 point outputs cosø TD W TD V TD A TD WH A V W cos ø ×3 ×3 ME110NSR-4A2P ME110NSR imported active energy exported active energy CT VT CT System construction example MELSEC series MELSEC NET/10H Power receiving room Power company CC-Link Factory air conditioning lighting office automation equipments outlets cubicle cubicle Office CC-Link Electronic multi measuring instrument ME110NSR series Low voltage Air Circuit Breaker AE-SW series Energy measuring unit Eco MonitorPro MDU breaker ME110NSR PC VT CT RS485 (ModBus) RS485 / RS232 converter RS232 31 units max. RS485 interface / Modbus RTU PLC VT CT VT CT 5 ME110NSR ● Measurable elements: AC current, AC voltage, active/reactive power, power factor, frequency, active energy, reactive energy, voltage harmonics, current harmonics etc. ● Output functions suitable for power monitoring: Analog 4 circuits, pulse 1 point and alarm 1 point (Analog 4 circuits, pulse 2 points also available) ■Specifications Model name Phase wire system Back up Auxiliary power Weight Enclosure Operating temperature Operating humidity Storage temperature Standard including max, and min. value including max value counting value ● +10 –15 Note ✽1 Remarks : Phase voltage measurable (1N, 2N, 3N) : 1. Accuracy of current, active/reactive power is at standard max scale value. 2. When used for 1P2W, accuracy of active power, active power demand & reactive power can exceed 0.5 due to the influence of power factor. 3. When input voltage falls to 11V, voltage related elements are displayed as follows : (Current is measured even when there is no voltage input) · Voltage, active/reactive power : “0” is displayed. · Power factor : “1” is displayed. · Frequency, current/voltage harmonics : “ _ _ _ _ ” is displayed. (For 3P4W, “ _ _ _ _ ” is displayed when they fall to 80V (@ rated voltage 110V) or 160V (@ rated voltage 220V).) A, DA, V, W, DW, cosø, var, Hz, HI, HV A, DA, V, W, DW, cosø, var, Hz ±1.0% Voltage circuit : 0.1VA/phase(@110VAC), 0.2VA/phase(@220VAC) Current circuit : 0.1VA/phase 11VA(@110VAC), 14VA(@220VAC) 6W(@100VDC) Stored In EEPROM (nonvolatile memory) : setting value, max/min value, active/reactive energy AC100-240V % 50-60Hz/DC75-140V Thermoplastic self-extinguish (UL94V0) -5~50°C (Average operating temperature : below 35°C) 85% RH max (no condensation) -20~60°C EN 61010-1/2001, EN61000-6-4/2001, EN61000-6-2/2001 ME110NSR-4APH Auto scale display by setting primary voltage/current, active/reactive power scale, power scale single/double deflection ME110NSR-4A2PME110NSR ●×3(1, 2, 3) ●×3(1, 2, 3) ●×3(12, 23, 31) ● ● – ● ● ●×3(1, 2, 3) ●×3(1, 2, 3) ●×3(12, 23, 31) ● ● – ● ● AC 5A ●×3(1, 2, 3) ●×3(1, 2, 3) ●×3(12, 23, 31) ● ● – ● ● ● (THD, h1···h13) (THD, h1···h13) ● (THD, h1···h13) (THD, h1···h13) ● (THD, h1···h13) (THD, h1···h13) ●×5(1, 2, 3, N, AVG) ●×5(1, 2, 3, N, AVG) ●×4(12, 23, 31, AVG) ✽1 ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×5(1, 2, 3, N, AVG) ●×5(1, 2, 3, N, AVG) ●×4(12, 23, 31, AVG) ✽1 ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×5(1, 2, 3, N, AVG) ●×5(1, 2, 3, N, AVG) ●×4(12, 23, 31, AVG) ✽1 ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) 0.5kg0.5kg0.5kg 0.5kg0.5kg0.5kg – – – (4 circuits) (2 points) – (4 circuits) (1 point) (1 point) Instantaneous value (0.5%) Demand (0.5%) Instantaneous value (0.5%) Demand (0.5%) Rated voltage Rated current Scale setting Settable standard maximum scale Input circuit Auxiliary power Upper limit setting Lower limit setting Setting accuracy Analog output Pulse output Alarm output Current Measuring elements (accuracy) Ratings Maximum scale Alarm setting Loading Output functions Power How to order Model name ME110NSR-4A2P Number of units 5 units English version ENGLISH Phase wire system 3P4W 3P3W (1P2W, 1P3W) ME Multi-measuring instrument Multi-measuring instrument ●Current scale 1P2W : Max scale = 0.5kW×VT ratio×CT ratio 1P3W : Max scale = 1kW×CT ratio 3P3W : Max scale = 1kW×VT ratio×CT ratio 3P4W : Max scale = Specific power×VT ratio×CT ratio ●Reactive power scale : active power scale×1/2 ●Power factor scale : LEAD0.5~1~LAG0.5 ●Frequency scale : 45Hz~55Hz or 55Hz~65Hz 3P3W/1P2W 150V(110V) Direct 300V(220V) Direct 300V(220V) 600V(440V) 1500V(1100V) 3000V(2200V) 4500V(3300V) 9000V(6600V) 750kV(550kV) 300V(220V) Direct only 1P3W ✽Instrument rated voltage with VT is fixed at 110V. ✽Primary voltage should be set with VT. 3P4W · Direct 100/150V(63.5/110V) 150/300V(110/190V) 300/600V(220/380V) 300/600V(240/415V) 300/600V(254/440V) · With VT 63.5/110V 100/173V 110/190V 115/199V 120/208V 110/220V 50-60Hz (Only 220V for 1P3W) 63.5/110~254/440V 50-60Hz 110/220V 50-60Hz (Only 220V for 1P3W) 63.5/110~254/440V 50-60Hz 110/220V 50-60Hz (Only 220V for 1P3W) 63.5/110~254/440V 50-60Hz 3P4W 1P2W/1P3W/3P3W (Common use) 3P4W 1P2W/1P3W/3P3W (Common use) 3P4W 1P2W/1P3W/3P3W (Common use) ●Voltage scale Voltage (0.5%) Apparent power (0.5%) Reactive power (0.5%) Power factor (2.0%) Frequency (0.5%) Active energy (1.0%) Reactive energy (2.0%) Current harmonics (2.5%) Voltage harmonics (2.5%) Range : 4-20mA, Load resistance : 600Ωmax Relay contact 35VDC, 0.2A Semiconductor relay contact 35VDC, 0.1A Analog output Alarm output Pulse output 6 ME110NSR (With communication) Note ✽1 Remarks : Phase voltage measurable (1N, 2N, 3N) : 1. Accuracy of current, active/reactive power is at standard max scale value. 2. When used for 1P2W, accuracy of active power, active power demand & reactive power can exceed 0.5 due to the influence of power factor. 3. When input voltage falls to 11V, voltage related elements are displayed as follows : (Current is measured even when there is no voltage input) · Voltage, active/reactive power : “0” is displayed. · Power factor : “1” is displayed. · Frequency, current/voltage harmonics : “ _ _ _ _ ” is displayed. (For 3P4W, “ _ _ _ _ ” is displayed when they fall to 80V (@ rated voltage110V) or 160V (@ rated voltage 220V).) How to order Model name ME110NSR-C Number of units 5 units English version ENGLISH Phase wire system 3P3W ● Measurement data transmission, as well as measurement and display of various elements : AC current , AC voltage, active/reactive power, power factor, frequency, active/reactive energy, voltage harmonics, current harmonics etc. ● Easy construction of network systems: CC-Link, Modbus communication ■Specifications Back up Auxiliary power Weight Enclosure Operating temperature Operating humidity Storage temperature Standard A, DA, V, W, DW, cosø, var, Hz, HI, HV A, DA, V, W, DW, cosø, var, Hz ±1.0% Voltage circuit : 0.1VA/phase(@110VAC), 0.2VA/phase(@220VAC) Current circuit : 0.1VA/phase 11VA(@110VAC), 14VA(@220VAC) 6W(@100VDC) Thermoplastic self-extinguish (UL94V0) -5~50°C (Average operating temperature : below 35°C) 85% RH max (no condensation) -20~60°C EN 61010-1/2001, EN61000-6-4/2001, EN61000-6-2/2001 Auto scale display by setting primary voltage/current, active/reactive power scale, power scale single/double deflection ME110NSR-C ME110NSR-MB ●×3(1, 2, 3) ●×3(1, 2, 3) ●×3(12, 23, 31) ● ● – ● ● ●×3(1, 2, 3) ●×3(1, 2, 3) ●×3(12, 23, 31) ● ● – ● ● AC 5A ●×5(1, 2, 3, N, AVG) ●×5(1, 2, 3, N, AVG) ●×4(12, 23, 31, AVG) ✽1 ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×5(1, 2, 3, N, AVG) ●×5(1, 2, 3, N, AVG) ●×4(12, 23, 31, AVG) ✽1 ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) ●×4(∑, 1, 2, 3) 0.5kg 0.5kg CC-Link communication Broadcast polling system 10M/5M/2.5M/625k/156kbps Bus format 50m (10Mbps)~1200m (156kbps) Max 42 units (Remote device station) RS485 (ModBus) communication ModBus RTU 2400,4800,9600,19200,38400bps Multi-dropped connection 1000m Max 31 untis ●Current scale 1P2W : Max scale = 0.5kW×VT ratio×CT ratio 1P3W : Max scale = 1kW×CT ratio 3P3W : Max scale = 1kW×VT ratio×CT ratio 3P4W : Max scale = Specific power×VT ratio×CT ratio ●Reactive power scale : active power scale×1/2 ●Power factor scale : LEAD0.5~1~LAG0.5 ●Frequency scale : 45Hz~55Hz or 55Hz~65Hz 3P3W/1P2W 150V(110V) Direct 300V(220V) Direct 300V(220V) 600V(440V) 1500V(1100V) 3000V(2200V) 4500V(3300V) 9000V(6600V) 750kV(550kV) 300V(220V) Direct only 1P3W ✽Instrument rated voltage with VT is fixed at 110V. 3P4W · Direct 100/150V(63.5/110V) 150/300V(110/190V) 300/600V(220/380V) 300/600V(240/415V) 300/600V(254/440V) · With VT 63.5/110V 100/173V 110/190V 115/199V 120/208V 110/220V 50-60Hz (Only 220V for 1P3W) 63.5/110~254/440V 50-60Hz 110/220V 50-60Hz (Only 220V for 1P3W) 63.5/110~254/440V 50-60Hz 3P4W 3P4W 1P2W/1P3W/3P3W (Common use) 1P2W/1P3W/3P3W (Common use) ●Voltage scale 0.5kg 0.5kg Multi-measuring instrument Model name Phase wire system Instantaneous value (0.5%) Demand (0.5%) Instantaneous value (0.5%) Demand (0.5%) Rated voltage Rated current Current Measuring elements (accuracy) Ratings Power Voltage (0.5%) Apparent power (0.5%) Reactive power (0.5%) Power factor (2.0%) Frequency (0.5%) Active energy (1.0%) Reactive energy (2.0%) Current harmonics (2.5%) Voltage harmonics (2.5%) Settable standard maximum scale Upper limit setting Lower limit setting Setting accuracy Maximum scale Alarm setting Communication Scale setting Input circuit Auxiliary power Communication Communication system Transmission speed Transmission path format Communication distance Number of units connected Loading ● (THD, h1···h13) (THD, h1···h13) ● (THD, h1···h13) (THD, h1···h13) ✽Primary voltage should be set with VT. +10 –15 Stored In EEPROM (nonvolatile memory) : setting value, max/min value, active/reactive energy AC100-240V % 50-60Hz/DC75-140V including max, and min. value including max value counting value ● 7 ■Settings (1P2W, 1P3W, 3P3W) ■Display and key functions Operating instructions ME110NSR DISPLAYPHASE MAX/MINRESET SET Digital display Measured values displayed in digital. Units Units of measuring value displayed : A, kA, V, kV, W, kW, MW, var, kvar, Mvar, cosø, Hz, kWh, kvarh, % Digital status Phase status, 123N, Max/Min, demand etc. displayed. Bar graph status or shows the item displayed on the bar graph. Indicated with , when the item is the same as a digital displayed item, otherwise indicated with . Multiplying factor Indicates the multiplying factor for calculating energy. Setup mode status Turns on at setup mode and setting value confirmation mode. Index indicator LAG status Scale at bar graph Upper/ lower limit alarm indicator Flickers at the limit setting value. Harmonics Turns on when harmonics displayed. Metering status Flickers when measuring incoming active energy. Also flickers at setting mode. Upper/ lower limit alarm status Turns on when the value exceeds the upper /lower limit. Over scale input Turns on when measuring values exceed the maximum scale. Under scale input Turns on when measuring values fall below the minimum scale. LEAD status ●Functions of operation buttons ●Setting items and flow Functions Buttons FunctionsOperations Special functionsBasic functions Buttons SET / MAX/MIN PHASE DISPLAY To measure, the primary voltage and current etc. need to be set at the setting mode. Shift from the operation mode to the set-up mode and setup necessary items. Factory default values apply for non-set items. Set up setting items such as primary voltage or primary current, and choose and indicate setting items. Change settings and bar graph display. Change display from Max/Min to instantaneous value. Chance phases. Change display. Press for 2 sec. Press for 2 sec. Press for 2 sec. Press for 2 sec. Press for 1 sec. DISPLAY PHASE & & RESET or Manual display change Cyclic display change Manual phase change Cyclic phase change Zoom display of Wh, varh values (last 3 digits) Reset all the Max/Min values. Fast forward or fast return values when setting. Reset Wh, varh values to zero by holding down the buttons for 2 sec. SET & RESET & PHASE 1 IN Phase wire system Display pattern Primary voltage Primary current Interval for active power demand LCD contrast Back light brightness Back light auto off Maximum scale for current Maximum scale for active power Active power scale deflection Maximum scale for reactive power Active energy measurement settings Indicator value 1 Alarm item ModBus address ModBus baud rates Alarm value Indicator item 2 Indicator value 2 Indicator item 3 Indicator value 3 Indicator item 4 Indicator value 4 Active power unit W/kW/MW Reactive power unit Harmonics Analog output 1 Analog output 2 Analog output 3 Analog output 4 Pulse output Alarm output test Alarm cancel method Alarm delay time Operation mode Action Shift to the End screen Select “CANCEL” Cancel the settings Skip remaining setting items Select a set value Go back to the previous setting item Select the menu number to set or “End” Shift from the operation mode to the set-up mode Key operation + or or or Arrow in figure Set-up mode or set value confirmation mode End display Cancel display Set-up menu 1 Set-up menu 2 Set-up menu 3 Set-up menu 4 ✽2 ✽2 ✽2 ✽2 ✽2 ✽2 ✽2 ✽2 ✽2 Set-up menu 5 Set-up menu 6 Set-up menu 8Set-up menu 7 (Example of set-up mode) (Example of set value confirmation mode) In the set-up mode “ ” is lit. Cancel the settings. Save the settings. Shift from the operation mode to the set value confirmation mode Shift to the next setting item Save the settings, and go back to the operation mode Press them simultaneously for 2 seconds Press for 2 seconds Press several times Press Press Press Press Press Press Press for 1 second Press several times ✽2 ✽2 ✽2 CC-Link station number CC-Link baud rates CC-Link module reset ModBus module reset ✽2 ✽2 ✽2 ✽1 ✽1 ✽1 ✽1: They may not display by the content of the set-up item. ✽2: They may not display by the model. ModBus parity ✽2 ModBus stop bit ✽2 (ME110SR-C) (ME110SR-MB) + + SET SET SET SET SET SET SET + – – – RESET DISPLAY Interval for demand current Model code Indicator item 1 8 ●Setting procedure Display the setting screen with , and setup the items with / . Settings can be registered for each setup menu number. Display the screen with and register with . Underlined values are factory defaults. SET SETEnd Set-up menu q Phase wire system wDisplay pattern ePrimary voltage DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY SET Three phase 3-wire Single phase 3-wire(1N2 display) Single phase 3-wire(1N3 display) Single phase 2-wire 3P3 N12 1P3 31N 1P3 1P2 : : : : :Displayable at this display setting. :Set at the set-up menu 3. : Select “P00” and setup display order and display position. 110V direct 220V direct 220V 440V 690V 1100V 1.1kV 2200V 2.2kV 3300V 3.3kV 6600V 6.6kV 11kV 13.2kV 13.8kV 15kV 16.5kV 22kV 24kV 33kV 66kV 77kV 110kV 132kV 154kV 187kV 220kV 275kV 380kV 500kV 550kV SP P01 P02 P03 P04 P05 P06 P07 P08 P09 P10 P11 P12 P00 A Display pattern DA V W DW cosø var Hz Whvarh Wh exported active energy varh special HI HV Set the set-up menu number to “1”. HI : Current harmonics, HV : Voltage harmonics, DA : Demand current, DW : Active power demand w Set the display pattern. q Set the phase wire system. e Set the primary voltage. tInterval for active power demand yInterval for demand current Set-up menu 0sec. 10sec. 20sec. 30sec. 40sec. 50sec. 1min. 2min. 3min. 4min. 5min. 6min. 7min. 8min. 9min. 10min. 15min. 20min. 25min. 30min. 0sec. 10sec. 20sec. 30sec. 40sec. 50sec. 1min. 2min. 3min. 4min. 5min. 6min. 7min. 8min. 9min. 10min. 15min. 20min. 25min. 30min. DISPLAY DISPLAY SET SET rPrimary current DISPLAY SET 5A 6A 7.5A 8A 10A 12A 15A 20A 25A 30A 40A 50A 60A 75A 80A 100A 120A 150A 200A 250A 300A 400A 500A 600A 750A 800A 1000A 1kA 1200A 1.2kA 1500A 1.5kA 1600A 1.6kA 2000A 2kA 2500A 2.5kA 3000A 3kA 4000A 4kA 5000A 5kA 6000A 6kA 7500A 7.5kA 8000A 8kA 10kA 12kA 20kA 25kA 30kA r Set the primary current. t Set the interval for active power demand. y Set the interval for demand current. ●Set-up Menu 1 (Phase wire system, display pattern, primary voltage/current, demand interval) , , , , , , , , · For 1P3W, primary voltage is fixed at 220V direct. · “SP” is a special primary voltage. · First 3 digits can be set from 220V to 55kV. · This screen also appears for display patterns without active power demand display. · If the active power demand is not necessary, press the button. · This screen also appears for display patterns without demand current display. · If the demand current is not necessary, press the button. ■Set other set-up menus ■Complete the setting Display screen with / , and register with . Complete the setting or set other set-up menus. Select the next set-up menu number with / . min min DEMAND DEMAND End SET SET SET 9 Set-up menu qMaximum scale for current wMaximum scale for active power e Active power scale deflection DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY SET SET , Set the set-up menu number to “3”. q Set the maximum scale for current. tMaximum scale for reactive power y Reactive power unit Set-up menu u Active energy measurement settings iHarmonics rActive power unit YES : Harmonics measured value displayed. no : Harmonics not measured. , , , , , , , , , i Set the measurement of harmonics. ■Set other set-up menus ■Complete the setting Complete the setting or set other set-up menus. WkW kWMW Combination Wh varh lag lead Imported active energy Exported active energy lag Imported Exported lead : imported active energy, : exported active energy, : varh lead, : varh lag LEAD LAG Combination Combination Combination Combination <Single deflection> Operating instructions ●Set-up Menu 3 (Bar graph, exported active energy, harmonics etc) · Maximum scale is set in the range of 40% to 120% of the rated current. t Set the maximum scale for reactive power. · The setting method is the same as that of w Maximum scale for active power. u Set the display settings for activce/reactive energy. · Combination of imported/exported and lag/lead can be selected. Combination in the diagram is the standard use. y Set the reactive power unit (var, kvar, Mvar). · The setting method is the same as that of r Active power unit. w Set the maximum scale of active power and active power demand. · Maximum scale is set in the range of 40% to 120% of the rated full load power. e Set the single/double/special double deflection of active power and active power demand. r Set the active power unit (W, kW, MW). Max scale: 1,000W~10,000W Max scale: 1,000kW~10,000W · When and are pressed, the scale value of bar graph blinks with single/double/special double deflection. · When special double deflection is selected, the minimum scale value can be set between -20% to -100% of the rated total load power. <Double deflection> <Special double deflection> HARMONICS Select the next set-up menu number with / . varh h LEAD LAG varh h LAG varh h LEAD LAG varh h LAG Display screen with / , and register with . End SET [...]... Service network Country / Region Company Address Telephone P.T.SAHABAT INDONESIA JL Muara Karang Selatan Blok A/Utara No.1 kav NO.11 P.O Box 5045/Jakarta/11050 Jakarta Indonesia + 62-(0)21-6621780 Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD 2 Fl Dong Seo Game Channel Bldg., 1F 660-11 Deungchon-Dong, Kanguseo-Ku, Seoul, 157-030 Korea + 82-2-3668-6567 Philippines EDISON ELECTRIC INTEGRATED, INC . ELECTRONIC MULTI-MEASURING INSTRUMENT — Best solution for energy measurement — Mitsubishi Electric Corporation's Fukuyama Works, which produces these products, is certified. ISO 14001 environmental management system standard. — Best solution for energy measurement — Mitsubishi Electronic Multi-measuring instrument New-S series features high performance and crystal. Company Address Telephone Indonesia Korea Philippines Taiwan Thailand Vietnam P.T.SAHABAT INDONESIA. MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD. EDISON ELECTRIC INTEGRATED, INC. Setsuyo Enterprise

Ngày đăng: 22/07/2014, 19:20

TỪ KHÓA LIÊN QUAN

w