ISUP Supplementary Services Testing The ISUP supplementary test specification is found in ITU Q.785 [91 ]. The p urpose of the t ests is to ensure validation and compatibility of an SP's user-to-user signaling (UUS), closed user group (CUG), calling line identification (CLI), and connected line identification (COL) supplementary services according to ITU Q.730 [69 ]—to a reasonable, but not exhaustive degree. Tests for the other supplementary services have not been specified. The tests are split into four categories according to supplementary service. Table 16-4 shows the test categories and the tests therein. Table 16-4. Test Categories and Test Numbers in Q.785 Category Test Number(s) Total User-to-User Signaling (UUS)—implicit request 1.1.1.1.1–1.1.1.1.2, 1.1.1.2.1–1.1.1.2.2, 1.1.1.3.1–1.1.1.3.2 6 Closed User Group (CUG)—decentralized 2.1.1–2.1.8 9 Calling Line Identification (CLI) 3.1.1–3.1.2, 3.2.1–3.2.2, 3.3.1–3.3.2, 3.4.1– 3.4.2, 3.5.1–3.5.2, 3.6.1–3.6.4, 3.7.1–3.7.2 16 Connected Line Identification (COL) 6.1.1–6.1.2, 6.2.1–6.2.2, 6.3.1–6.3.2, 6.4.1– 6.4.2, 6.5.1–6.5.2, 6.6.1 – 6.6.2, 6.7.1–6.7.2, 6.8.1 15 Totals 46 The remainder of this section provides an explanation of three of these tests: 2.1.1, 3.1.1, and 6.1.1. These numbers refer to the test numbers allocated in Q.785. Test Configuration Only a single test configuration is used: the same one that is used in ISUP basic call control testing. The test configuration consists of SP A and SP B. SP A is the device under test DUT, while SP B is the Tester or an SP whose ISUP protocol has been verified. Links and bearers are provided between the two SPs. The test specification makes use of stimulus in relation to creating certain conditions. E xample 1: CUG Call with Out g oin g Access Allowed and Sent, Test 2.1.1 This test is to check that the DUT can correctly send the parameters that are necessary for a CUG call with outgoing access allowed. It is used for both validation and compatibility testing purposes. The DUT should generate an IAM that contains the optional CUG interlock code p arameter set to "interlock code included" and the forward call indicators p arameter with the CUG call indicator set to "CUG call, outgoing access allowed." It is up to the person(s) carrying out the testing how "invoke" should be used. A call should be established even if SP B is not connected to a network that supports the CUG service. Figure 16-24 shows the expected message sequence for this test. Figure 16-24. Expected Message Sequence for Test 2.1.1 Consider the test passed if the IAM contains the CUG interlock code parameter and forward call indicators with the contents specified previously, and if the call is successfully set up and cleared. E xample 2: CLIP—Network Provided and Sent, Test 3.1.1 This test is to verify that the DUT can correctly send an IAM with calling line identification presentation (CLIP) set in the calling party number parameter. It is used for both validation and compatibility testing purposes. The DUT should generate an IAM that contains the optional calling party number p arameter, with the fields presentation restriction indicator set to 00 (presentation allowed) and screening indicator set to 11 (network provided). Consider the test passed if the received IAM contains the calling party number p arameter with the contents specified previously, and the call is successfully set up and cleared. E xample 2: COL—Requested and Sent, Test 6.1.1 This test is to check that the DUT can correctly send an IAM with a request for COL. It is used for both validation and compatibility testing purposes. The DUT should generate an IAM containing the optional forward call indicators p arameter with the field connected line identification indicator set to 1 (requested). It is up to the person(s) carrying out the testing to decide how to provoke such an IAM. Consider the test passed if the IAM contains the forward call indicators parameter with the contents specified above, and the call is successfully setup and cleared. < Day Day Up > The SCCP test specification is found in ITU Q.786 [92 ]. The purpose of the tests is to ensure validation and compatibility of an SP's SCCP connectionless protocol according to ITU Q.711–716 [58 –63], with a degree of confidence. There are no tests covering management, segmentation, or connection-oriented procedures— these are listed in the specification for further study. This test specification can be considered inadequate for many purposes, leading some European operators to write their own in-house test specifications completely from scratch. The tests are split up into three categories. Table 16-5 shows the test categories and the tests that they contain. Table 16-5. Test Categories and Test Numbers in Q.786 Category Test Number(s) Total Messages from SCCP users Route not on GT 1.1.1.1.1.1–1.1.1.1.1.2, 1.1.1.1.2–1.1.1.1.6 7 Route on GT 1.1.1.2.1.1–1.1.1.2.1.2, 1.1.1.2.2–1.1.1.2.3, 1.1.1.2.4.1–1.1.1.2.4.2, 1.1.1.2.5–1.1.1.2.9 11 Messages from MTP Route on GT 1.1.2.1.1–1.1.2.1.9 9 Route not on GT 1.1.2.2.1.1–1.1.2.2.1.2, 1.1.2.2.2–1.1.2.2.3 4 Data transfer Data transfer with sequential delivery capability 1.2.1.1–1.2.1.2 2 Data transfer with syntax error 1.2.2 1 Message return 1.2.3 1 UDTS deliverable 1.2.3.1.1–1.2.3.1.2 2 UDTS undeliverable 1.2.3.2.1 1 Totals 38 The remainder of this section explains three of these tests: 1.1.1.1.1, 1.1.1.1.6, and 1.1.2.2.1.2. These numbers refer to the test numbers allocated in Q.786. Test Configuration Two test configurations(named 1 and 2) are used for SCCP testing. For the three tests presented in this section, only configuration 1 is used. Figure 16-25 shows configuration 1. Figure 16-25. The Test Configuration 1, Used for SCCP Testing E xample 1: Local DPC and SSN Included, DPC and SSN Available, GT and S SN Included and Sent, Test 1.1.1.1.1.1 This test is to check that the DUT SCCP can deliver user data to the correct SCCP user at the DUT when routing is not on Global Title (GT). It is used for validation testing purposes only. An SSN should be made available at the DUT. The DUT should request delivery of user data to a DUT SCCP user with a DPC and SSN of the DUT in the request. Figure 16-26 shows the primitive sequence for this test. Figure 16-26. Expected Message Sequence for Test 1.1.1.1.1.1 Consider the test passed if the DUT does not send a message to SPB B and the data is correctly delivered to the SCCP user at the DUT. E xample 2: Remote DPC and SSN Included, DPC and/or SSN Unavailable— R eturn Option Not Set, Test 1.1.1.1.6 This test checks that the DUT does not return user data sent from the DUT SCCP user when the return option is not set (and the route is not on GT). It is used for validation testing purposes only. The SCCP routing control data should be set such that the DPC of SP B is unavailable and/or SSN at SP B is unavailable. The DUT SCCP user should request delivery of user data to the remote DPC and the SSN at SP B. Figure 16-27 shows the primitive sequence for this test. Figure 16-27. Expected Message Sequence for Test 1.1.1.1.6 Consider the test passed if the DUT does not send a message to SPB B, and if the data is not returned to the SCCP user at the DUT. E xample 3: Local DPC and SSN, and SSN Available GT Not Included, SSN I ncluded, Test 1.1.2.2.1.2 This test is to check that the user data sent to the DUT SCCP user can be delivered to the correct DUT SCCP user when routing is not on GT. It is used for validation testing purposes only. An SSN should be made available at the DUT. The Tester should generate a Unitdata (UDT) message toward the DUT that is addressed with the SSN, no GT, and route on DPC+SSN. Figure 16-28 shows the primitive sequence for this test. Figure 16-28. Expected Message Sequence for Test 1.1.2.2.1.2 Consider the test passed if the DUT does not send an error message to SPB B and the data is delivered to the correct SCCP user at the DUT.  . and compatibility of an SP's SCCP connectionless protocol according to ITU Q .71 1 71 6 [58 63] , with a degree of confidence. There are no tests covering management, segmentation, or connection-oriented. DUT does not send a message to SPB B and the data is correctly delivered to the SCCP user at the DUT. E xample 2: Remote DPC and SSN Included, DPC and/ or SSN Unavailable— R eturn Option Not Set,. 3.5.1–3.5.2, 3.6.1–3.6.4, 3 .7. 1–3 .7. 2 16 Connected Line Identification (COL) 6.1.1–6.1.2, 6.2.1–6.2.2, 6.3.1–6.3.2, 6.4.1– 6.4.2, 6.5.1–6.5.2, 6.6.1 – 6.6.2, 6 .7. 1–6 .7. 2, 6.8.1 15 Totals

Ngày đăng: 02/07/2014, 09:20

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan