Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 15 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
15
Dung lượng
57,78 KB
Nội dung
13.3 Internal Data Representation Before we understand how to use PLI library routines, it is first necessary to describe how a design is viewed internally in the simulator. Each module is viewed as a collection of object types. Object types are elements defined in Verilog, such as: • Module instances, module ports, module pin-to-pin paths, and intermodule paths • Top-level modules • Primitive instances, primitive terminals • Nets, registers, parameters, specparams • Integer, time, and real variables • Timing checks • Named events Each object type has a corresponding set that identifies all objects of that type in the module. Sets of all object types are interconnected. A conceptual internal representation of a module is shown in Figure 13-3 . Figure 13-3. Conceptual Internal Representation a Module Each set contains all elements of that object type in the module. All sets are interconnected. The connections between the sets are bidirectional. The entire internal representation can be traversed by using PLI library routines to obtain information about the module. PLI library routines are discussed later in the chapter. To illustrate the internal data representation, consider the example of a simple 2-to- 1 multiplexer whose gate level circuit is shown in Figure 13-4 . Figure 13-4. 2-to-1 Multiplexer The Verilog description of the circuit is shown in Example 13-1 . Example 13-1 Verilog Description of 2-to-1 Multiplexer module mux2_to_1(out, i0, i1, s); output out; //output port input i0, i1; //input ports input s; wire sbar, y1, y2; //internal nets //Gate Instantiations not n1(sbar, s); and a1(y1, i0, sbar); and a2(y2, i1, s); or o1(out, y1, y2); endmodule The internal data representation for the 2-to-1 multiplexer is shown in Figure 13-5 . Sets are shown for primitive instances, primitive instance terminals, module ports, and nets. Other object types are not present in this module. Figure 13-5. Internal Data Representation of 2-to-1 Multiplexer The example shown above does not contain register, integers, module instances, and other object types. If they are present in a module definition, they are also represented in terms of sets. This description is a conceptual view of the internal structures. The exact implementation of data structures is simulator dependent. [ Team LiB ] [ Team LiB ] 13.4 PLI Library Routines PLI library routines provide a standard interface to the internal data representation of the design. The user-defined C routines for user-defined system tasks are written by using PLI library routines. In the example in Section 13.2 , Linking and Invocation of PLI Tasks, $hello_verilog is the user-defined system task, hello_verilog is the user-defined C routine, and io_printf is a PLI library routine. There are two broad classes of PLI library routines: access routines and utility routines. (Note that vpi_ routines are a superset of access and utility routines and are not discussed in this book.) Access routines provide access to information about the internal data representation; they allow the user C routine to traverse the data structure and extract information about the design. Utility routines are mainly used for passing data across the Verilog/Programming Language Boundary and for miscellaneous housekeeping functions. Figure 13-6 shows the role of access and utility routines in PLI. Figure 13-6. Role of Access and Utility Routines A complete list of PLI library routines is provided in Appendix B , List of PLI Routines. The function and usage of each routine are also specified. 13.4.1 Access Routines Access routines are also popularly called acc routines. Access routines can do the following: • Read information about a particular object from the internal data representation • Write information about a particular object into the internal data representation We will discuss only reading of information from the design. Information about modifying internal design representation can be found in the Programming Language Interface (PLI) Manual. However, reading of information is adequate for most practical purposes. Access routines can read information about objects in the design. Objects can be one of the following types: • Module instances, module ports, module pin-to-pin paths, and intermodule paths • Top-level modules • Primitive instances, primitive terminals • Nets, registers, parameters, specparams • Integer, time, and real variables • Timing checks • Named events Mechanics of access routines Some observations about access routines are listed below. • Access routines always start with the prefix acc_. • A user-defined C routine that uses access routines must first initialize the environment by calling the routine acc_initialize(). When exiting, the user- defined C routine must call acc_close(). • If access routines are being used in a file, the header file acc_user.h must also be included. All access routine data types and constants are predefined in the file acc_user.h. • #include "acc_user.h" • Access routines use the concept of a handle to access an object. Handles are predefined data types that point to specific objects in the design. Any information about the object can be obtained once the object handle is obtained. This is similar to the concept of file handles for accessing files in C programs. An object handle identifier is declared with the keyword handle. handle top_handle; Types of access routines We discuss six types of access routines. • Handle routines. They return handles to objects in the design. The name of handle routines always starts with the prefix acc_handle_. • Next routines. They return the handle to the next object in the set of a given object type in a design. Next routines always start with the prefix acc_next_ and accept reference objects as arguments. • Value Change Link (VCL) routines. They allow the user system task to add and delete objects from the list of objects that are monitored for value changes. VCL routines always begin with the prefix acc_vcl_ and do not return a value. • Fetch routines. They can extract a variety of information about objects. Information such as full hierarchical path name, relative name, and other attributes can be obtained. Fetch routines always start with the prefix acc_fetch_. • Utility access routines. They perform miscellaneous operations related to access routines. For example, acc_initialize() and acc_close() are utility routines. • Modify routines. They can modify internal data structures. We do not discuss them in this book. Refer to the IEEE Standard Verilog Hardware Description Language document for details about modify routines. A complete list of access routines and their usage is provided in Appendix B , List of PLI Routines. Examples of access routines We will discuss two examples that illustrate the use of access routines. The first example is a user-defined system task to find names of all ports in a module and count the number of ports. The second example is a user-defined system task that monitors the changes in values of nets. Example 1: Get Module Port List Let us write a user-defined system task $get_ports to find complete hierarchical names of input, output, and inout ports in a module and to count the number of input, output, and inout ports. The user-defined system task will be invoked in Verilog as $get_ports("<hierarchical_module_name>"). The user-defined C routine get_ports, which implements the task $get_ports, is described in file get_ports.c. The file get_ports.c is shown in Example 13-3 . Example 13-2 PLI Routine to get Module Port List #include "acc_user.h" int get_ports() { handle mod, port; int input_ctr = 0; int output_ctr = 0; int inout_ctr = 0; acc_initialize(); mod = acc_handle_tfarg(1); /* get a handle to the module instance first argument in the system task argument list */ port = acc_handle_port(mod, 0); /* get the first port of the module */ while( port != null ) /* loop for all ports */ { if (acc_fetch_direction(port) == accInput) /* Input port */ { io_printf("Input Port %s \n", acc_fetch_fullname(port)); /* full hierarchical name */ input_ctr++; } else if (acc_fetch_direction(port) == accOutput) /* Output port */ { io_printf("Output Port %s \n", acc_fetch_fullname(port)); output_ctr++; } else if (acc_fetch_direction(port) == accInout) /* Inout port */ { io_printf("Inout Port %s \n", acc_fetch_fullname(port)); inout_ctr++; } port = acc_next_port(mod, port); /* go to the next port */ } io_printf("Input Ports = %d Output Ports = %d, Inout ports = %d\n\n", input_ctr, output_ctr, inout_ctr); acc_close(); } N otice that handle, fetch, next, and utility access routines are used to write the user C routine. Link the new task into the Verilog simulator as described in Section 13.2.1 , Linking PLI Tasks. To check the newly defined task, we will use it to find out the p ort list of the module mux2_to_1 described in Example 13-1. A top-level module that instantiates the 2-to-1 multiplexer and invokes the $get_ports task is shown below. module top; wire OUT; reg I0, I1, S; mux2_to_1 my_mux(OUT, I0, I1, S); /*Instantiate the 2-to-1 mux*/ initial begin $get_ports("top.my_mux"); /*invoke task $get_ports to get port list*/ end endmodule Invocation of $get_ports causes the user C routine $get_ports to be executed. The output of the simulation is shown below. Output Port top.my_mux.out Input Port top.my_mux.i0 Input Port top.my_mux.i1 Input Port top.my_mux.s Input Ports = 3 Output Ports = 1, Inout ports = 0 Example 2: Monitor Nets for Value Changes This example highlights the use of Value Change Link (VCL) routines. Instead of using the $monitor task provided with the Verilog simulator, let us define our own task to monitor specific nets in the design for value changes. The task $my_monitor("<net_name>"); is to be invoked to add a <net_name> to the monitoring list. The user-defined C routine my_monitor, which implements the user-defined system task, is shown in Example 13-3 . Example 13-3 PLI Routine to Monitor Nets for Value Changes #include "acc_user.h" char convert_to_char(); int display_net(); int my_monitor() { handle net; char *netname ; /*pointer to store names of nets*/ char *malloc(); acc_initialize(); /*initialize environment*/ net = acc_handle_tfarg(1); /*get a handle to the net to be monitored*/ /*Find hierarchical name of net and store it*/ netname = malloc(strlen(acc_fetch_fullname(net))); strcpy(netname, acc_fetch_fullname(net)); /* Call the VCL routine to add a signal to the monitoring list*/ /* Pass four arguments to acc_vcl_add task*/ /* 1st : handle to the monitored object (net) 2nd : Consumer C routine to call when the object value changes (display_net) 3rd : String to be passed to consumer C routine (netname) 4th : Predefined VCL flags: vcl_verilog_logic for logic monitoring vcl_verilog_strength for strength monitoring */ acc_vcl_add(net, display_net, netname, vcl_verilog_logic); acc_close(); } N otice that the net is added to the monitoring list with the routine acc_vcl_add. A consumer routine display_net is an argument to acc_vcl_add. Whenever the value of the net changes, the acc_vcl_add calls the consumer routine display_net and p asses a pointer to a data structure of the type p_vc_record. A consumer routine is a C routine that performs an action determined by the user whenever acc_vcl_add calls it. The p_vc_record is predefined in the acc_user.h file, as shown below. typedef struct t_vc_record{ int vc_reason; /*reason for value change*/ int vc_hightime; /*Higher 32 bits of 64-bit simulation time*/ int vc_lowtime; /*Lower 32 bits of 64-bit simulation time*/ char *user_data; /*String passed in 3rd argument of acc_vcl_add*/ union { /*New value of the monitored signal*/ unsigned char logic_value; double real_value; handle vector_handle; s_strengths strengths_s; } out_value; } *p_vc_record; The consumer routine display_net simply displays the time of change, name of net, and new value of the net. The consumer routine is written as shown in Example 13-4. Another routine, convert_to_char, is defined to convert the logic value constants to an ASCII character. Example 13-4 Consumer Routine for VCL Example /*Consumer routine. Called whenever any monitored net changes*/ display_net(vc_record) p _vc_record vc_record; /*Structure p_vc_record predefined in acc_user.h*/ { /*Print time, name, and new value of the changed net */ io_printf("%d New value of net %s is %c \n", vc_record->vc_lowtime, vc_record->user_data, convert_to_char(vc_record->out_value.logic_value)); } /*Miscellaneous routine to convert predefined character constant to ASCII character*/ char convert_to_char(logic_val) char logic_val; { char temp; switch(logic_val) { /*vcl0, vcl1, vclX and vclZ are predefined in acc_user.h*/ case vcl0: temp='0'; break; case vcl1: temp='1'; break; case vclX: temp='X'; break; case vclZ: temp='Z'; break; } return(temp); } Link the new task into the Verilog simulator as described in Section 13.2.1 , Linking PLI Tasks. To check the newly defined task, we will use it to monitor nets sbar and y1 when stimulus is applied to module mux2_to_1 described in Example 13-1 on page 281. A top-level module that instantiates the 2-to-1 multiplexer, applies stimulus, and invokes the $my_monitor task is shown below. module top; wire OUT; reg I0, I1, S; mux2_to_1 my_mux(OUT, I0, I1, S); //Instantiate the module mux2_to_1 initial //Add nets to the monitoring list begin $my_monitor("top.my_mux.sbar"); $my_monitor("top.my_mux.y1"); end initial //Apply Stimulus begin I0=1'b0; I1=1'b1; S = 1'b0; #5 I0=1'b1; I1=1'b1; S = 1'b1; #5 I0=1'b0; I1=1'b1; S = 1'bx; #5 I0=1'b1; I1=1'b1; S = 1'b1; end endmodule [...]... the newly defined task $my_stop_finish, a stimulus in which $my_stop_finish is called with all possible combinations of arguments is applied to the module mux2_to_1 described in Example 13-1 on page 281 A toplevel module that instantiates the 2-to-1 multiplexer, applies stimulus, and invokes the $my_stop_finish task is shown below module top; wire OUT; reg I0, I1, S; mux2_to_1 my_mux(OUT, I0, I1, S); . routines can do the following: • Read information about a particular object from the internal data representation • Write information about a particular object into the internal data representation. nets sbar and y1 when stimulus is applied to module mux2_to_1 described in Example 13-1 on page 281 . A top-level module that instantiates the 2-to-1 multiplexer, applies stimulus, and invokes. combinations of arguments is applied to the module mux2_to_1 described in Example 13-1 on page 281 . A top- level module that instantiates the 2-to-1 multiplexer, applies stimulus, and invokes