1. Trang chủ
  2. » Công Nghệ Thông Tin

The Essential Guide to Image Processing- P28 pot

30 308 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 30
Dung lượng 623,28 KB

Nội dung

822 CHAPTER 27 Computer-Assisted Microscopy 27.6.5.1 Deblurring Weinstein and Castleman pioneered the deblurring of optical section images using a simple method that involves subtracting adjacent plane images that have been blurred with an appropriate defocus psf [69],givenby f j ≈ g j Ϫ M  iϭ1  g jϪi ∗h Ϫi ϩ g jϩi ∗h i  ∗k 0 , (27.14) where f j is the specimen brightness distribution at focus level j, g j is the optical section image obtained at level j, h i is the blurring psf due to being out of focus by the amount i, k 0 is a heuristically designed highpass filter, and the ∗ represents the convolution operation. Thus one can partially remove the defocused structures by subtracting 2M adjacent plane images that have been blurred with the appropriate defocus psf and convolved with a suitable highpass filter k 0 . The filter, k 0 , and the number, M, of adjacent planes must be selected to give good results. While this technique cannot recover the specimen function exactly, it does improve optical section images at reasonable computational expense. It is often necessary to use only a small number, M, of adjacent planes to remove most of the defocused information. Figure 27.17 shows images from transmitted light microscopy and fluorescence microscopy that have been deblurred using optical sections above and below at a Z-interval of 1 ␮m. While this technique cannot recover the specimen function exactly, it does improve optical section images at reasonable computational expense. FIGURE 27.17 Deblurring. The top row shows images of FISH-labeled lymphocytes. The left three images are from an optical section stack taken one micron apart. The right image is the middle one deblurred. The in-plane dots are brighter, while the out-of-plane dots are removed. The bottom row shows transmitted images of May-Giemsa stained blood cells. The left three images are from an optical section stack taken one-half micron apart. The rightmost image is the middle one deblurred. 27.6 Applications in Clinical Cytogenetics 823 27.6.5.2 Image Fusion One effective way to combine a set of deblurred optical section images into a single 2D image containing the detail from each involves the use of the wavelet transform [8]. A linear transformation is defined by a set of basis functions. It represents an image by a set of coefficients that specify what mix of basis functions is required to reconstruct that image. Reconstruction is effected by summing the basis functions in proportions specified by the coefficients. The coefficients thus reflect how much each of the basis functions resembles a component of the original image. If a few of the basis functions match the components of the image, then their coefficients will be large and the other coefficients will be negligible, yielding a very compact representation. The coefficients that correspond to the desired components of the image can be increased in magnitude, prior to reconstruction, to enhance those components. 27.6.5.3 Wavelet Design A wavelet transform is a linear transformation in which the basis functions (except the first) are scaled and shifted versions of one function, called the “mother wavelet.” If the wavelet can be selected to resemble components of the image, then a compact represen- tation results. There is considerable flexibility in the design of basis functions. Thus it is often possible to design wavelet basis functions that are similar to the image compo- nents of interest. These components, then, are represented compactly in the transform by relatively few coefficients. These coefficients can be increased in amplitude, at the expense of the remaining components, to enhance the interesting content of the image. Fast algorithms exist for the computation of wavelet transforms. Mallat’s iter ative algorithm for implementing the one-dimensional discrete wavelet transform (DWT) [70, 71] is shown in Fig. 27.18. In the design of an orthonormal DWT, one begins with a “scaling ve ctor,” h 0 (k), of even length. The elements of the scaling vector must satisfy certain constraints imposed by invertibility. For example, the elements must f(i) g 1 (k) h 0 (Ϫk) ~ f 1 (k) f r (i) h 1 (Ϫk) h 0 (k) h 1 (k) ~ + FIGURE 27.18 Mallat’s (1D) DWT algorithm. The left half shows one step of decomposition, while the right half shows one step of reconstruction. The down and up arrows indicate downsampling and upsampling by a factor of two, respectively. For an orthonormal transform, the two filters on the right are the same as the two on the left. Further steps of decomposition and reconstruction are introduced at the open circle. 824 CHAPTER 27 Computer-Assisted Microscopy sum to √ 2, their squares must sum to unity, and the sum of the even-numbered elements must equal the sum of the odds [65].Fromh 0 (k) is generated a “wavelet vector” h 1 (k) ϭϮ (Ϫ1) k h 0 (Ϫk). (27.15) These two vectors are used as discrete convolution kernels in the system of Fig. 27.18 to implement the DWT. For example, all possible four-element orthonormal scaling vectors are specified by h 0 ϭ [ c 1 c 3 c 1 c 2 Ϫc 2 c 3 ] T , (27.16) where c 3 ϭ  1 Ϫ  c 2 1 ϩ c 2 2   c 2 1 ϩ c 2 2 , (27.17) and c 1 and c 2 are free choice parameters. All even-length orthonormal scaling vectors, and biorthogonal scaling vectors of any length, can be similarly parameterized. Mallat’s algorithm leads to the “cascade” algorithm of Daubechies [70, 71],whichisa simple method for constr ucting the basis functions that correspond to specified scaling and wavelet vectors. With these tools it is then simple to specify and design wavelet transforms with desired properties. Given parameterized scaling and wavelet vectors, first select the parameter values (e.g., c 1 and c 2 , above) and then use the cascade algorithm to construct the corresponding scaling function and basic wavelet. These show the form of the basis functions of that wavelet transform. Repeat the process using differentparameter values until the desired basis function shape is attained. Then use h 0 (k) and h 1 (k) in the 2D version of Mallat’s algorithm to implement the wavelet transform and its inverse. 27.6.5.4 Wavelet Fusion Image fusion is the technique of combining multiple images into one that preserves the interesting detail of each [72]. The wavelet transform affords a convenient way to fuse images. One simply takes, at each coefficient position, the coefficient value having maximum absolute amplitude and then reconstructs an image from all such maximum- amplitude coefficients. If the basis functions match the interesting components of the image, then the fused image will contain the interesting components collected up from all of the input images. The images can be combined in the transform domain by taking the maximum-amplitude coefficient at each coordinate. An inverse wavelet transform of the resulting coefficients then reconstructs the fused image. We found that deblurring prior to wavelet fusion significantly improves the measured sharpness of the processed images. An example of wavelet image fusion using transmitted light and fluorescence images is shown in Fig. 27.19. Optical section deblurring followed by image fusion produced an image in which all of the dots are visible for the fluorescence images. We use these techniques to improve the information content of images from thick samples. Specifically,thistechnique improves the dotinformationin acquired FISH images because it incorporates data from focal planes above and below. 27.7 Commercially Available Systems 825 27.7 COMMERCIALLY AVAILABLE SYSTEMS Computer-assisted microscopy systems can vary in price, sensitivity, and capability. The selection of a system depends upon the experimental applications for which itwill be used. Typically, the selection is based on requirements for image resolution, sensitivity, light conditions, image acquisition time, image storage requirements, and most importantly the postacquisition image processing and analysis required. Other considerations are the technical demands of assembling the component hardware and configuring software. Computerized imaging systems can be assembled from component parts or obtained from a supplier as a fully integrated system. Several companies offer fully integrated computerized microscopy systems and/or provide customized solutions for specialized systems. A brief listing of some of the commercially available systems is provided here. Applied Precision Inc. (Issaquah, WA) provides a computerized imaging instrument, the DeltaVision TM Restoration Microscopy System for applications such as 3D time course studies with live cell material. Applied Precision also offers the softWoRx TM Imaging Workstation for post-acquisition image processing such as deconvolution, 3D segmentation, and rendering. Universal Imaging Corp. (West Chester, PA) provides software, including the MetaMorph TM , MetaView TM , and MetaFluor TM systems, which can be customized for computerized microscopy applications in transmitted light, time FIGURE 27.19 Image fusion using transmitted light and fluorescence images. The top row shows FISH-labeled lymphocytes. The left three images are from a deblurred optical section stack taken one micron apart. The right image is the fusion of the three using the biorthogonal 2,2 wavelet transform. Notice that the fused image has all of the dots in focus. The bottom rows demonstrate a similar effect in transmitted light images. The deblurring process, followed by image fusion, enhances image detail. 826 CHAPTER 27 Computer-Assisted Microscopy lapse studies, and fluorescence microscopy. VayTek Inc. (Fairfield, Iowa) provides an integrated microscopy imaging system, the Proteus TM system, that can be custom con- figured to any microscopy system. VayTek’s proprietary software for deconvolution and 3D reconstruction, including MicroTome TM , VoxBlast TM , HazeBuster TM ,Vtrace TM , and Volume-Scan TM , can also be custom configured for most current microscopy systems. ChromaVision Medical Systems Inc. (San Juan, CA) provides an Automated Cellular Imaging System that allows celldetection based on color-,size-, andshape-basedmorpho- metric features. MetaSystems GmbH (Altlussheim, Germany) provides a computerized microscopy system based on Zeiss optics for scanning and imaging pathology slides, cyto- genetic slides for FISH, MFISH, and metaphase detection, oncology slides, and for rare cell detection, primarily from blood, bone marrow, or tissue section samples. Applied Imaging Corp. (Santa Clara, CA), now part of MetaSystems GmbH, Germany, provides fully automated scanning and image analysis systems. Their MDS TM system provides automated slide scanning using brightfield or fluorescent illumination to allow standard karyotyping, FISH,and comparative genomic hybridization, as well as rare cell detection. They also have the Oncopath TM and Ariol Sl-50 TM image analysis systems for oncology and clinical pathology applications. The field of automated imaging is also of great interest to pharmaceutical and biotechnology companies. Many are now developing high-throughput and high-content screening platforms for automated analysis of intracellular localization and dynamics of proteins and to view the effects of a drug on living cells more quickly. High- content imaging systems for cell-based assays have proliferated in the past year, examples include Cellomic’s ArrayScan system and KineticScan workstation (Cellomics, Inc., Pitts- burgh, PA); Amersham’s INCell Analyzer 1000 and 3000 (Amersham Biosciences Corp., Piscataway, NJ); Acumen Bioscience’s Explorer system (Melbourn, United Kingdom); CompuCyte’s iCyte imaging cytometer and LSC laser scanning cytometer (CompuCyte Corporation, Cambridge, MA); Atto Bioscience’s Pathway HT kinetic cell imaging sys- tem (Atto Bioscience Inc., Rockville, MD); Universal Imaging’s Discovery-1 system (Uni- versal Imaging Corporation, Dow ningtown, PA); and Q3DM’s (now part of Beckman Coulter, San Diego, CA), EIDAQ 100 High-Throughput Microscopy (HTM) system (recently discontinued). 27.8 CONCLUSIONS The rapid development of microscopy techniques over the last few decades has been accompanied by similar advances in the development of new fluorescent probes and improvements in automated microscope systems and software. Advanced applications such as deconvolution, FRET, and ion ratio imaging require sophisticated routines for controlling automated microscopes and peripheral devices such as filter wheels, shut- ters, automated stages, and cameras. Computer-assisted microscopy provides the ability to enhance the speed of microscope data acquisition and data analysis, thus relieving 27.8 Conclusions 827 humans of tedious tasks. Not only the cost efficiency is improved due to the correspond- ing reduction in labor costs and space but also errors associated with operator bias are eliminated. Researchers are not only relieved from tedious manual tasks but may also quickly examine thousands of cells, plates, and slides, as well as precisely determine some informative activity against a cell, and collect and mine massive amounts of data. The process is also repeatable and reproducible with a high degree of precision. We have described a specific configuration of a computerized fluorescence microscope with applications in clinical cytogenetics. Fe tal cell screening from maternal blood has the potential to revolutionize the future of prenatal genetic testing, making noninvasive testing available to all pregnant women. Its clinical realization will be practical only via an automated screening procedure because of the rare number of fetal cells available. Spe- cialized slides, based on the grid template, such as the subtelomeric FISH assay, require automated scanning methods to increase accuracy and efficiency of the screening pro- tocol. Similarly, automated techniques are necessary to allow the quantitative analysis for the measurement of the separation distance for detection of duplicated genes. Thick specimen imaging using deblurring methods allows the detection of cell structures that are distributed throughout the volume of the entire cell. Thus, there are sound reasons for pursuing the goal of automation in medical cytogenetics. Not only does automation increase laboratory throughput, it also decreases laboratories’ costs for performing tests. And as tests become more objective, the liability of laboratories also decreases. The mar- ket for comprehensive automated tests is vast in terms of both size (whether measured in test volume or dollars) and potential impact on people’s lives. The effective commercial use of computer-assisted microscopy and quantitative image analysis requires the careful integration of automated microscopy, high-quality image acquisition, and powerful analytical algorithms that can r ationally detect, count, and quantify areas of interest. Typically, the systems should provide walk-away scanning operation with automated slide loaders that can queue several (50 to 200) slides. Addi- tionally, the automated microscopy systems should have the capability to integrate with viewing stations to create a network for reviewing images, analyzing data, and gener- ating reports. There has been an increase in the commercialization of computerized microscopy and high-content imaging systems over that past five years. Clearly, future developments in this field will be of great interest to biotechnology. All signs indicate that superior optical instrumentation and software for cell research are on the development horizon. ACKNOWLEDGMENTS We would like to thank Vibeesh Bose, Hyohoon Choi, and Mehul Sampat for their assistance with the development and testing of the computerized microscopy system. The development of the automated microscopy system was partially supported by NIH SBIR Grant Nos. HD34719-02, HD38150-02, and GM60894-01. 828 CHAPTER 27 Computer-Assisted Microscopy REFERENCES [1] M. Bravo-Zanoguera, B. Massenbach, A. Kellner, and J. H. Price. High-performance a utofocus circuit for biological microscopy. Rev. Sci. Instrum., 69:3966–3977, 1998. [2] J. C. Oosterwijk, C. F. Knepfle, W. E. Mesker, H. Vrolijk, W. C. Sloos, H. Pattenier, I. Ravkin, G. J. van Ommen, H. H. Kanhai, and H. J. Tanke. Strategies for rare-event detection: an approach for automated fetal cell detection in maternal blood. Am. J. Hum. Genet., 63:1783–1792, 1998. [3] L. A. Kamenstsky, L. D. Kamenstsky, J. A. Fletcher, A. Kurose, and K. Sasaki. Methods for auto- matic multiparameter analysis of fluorescence in situ hybr idized specimens with a laser scanning cytometer. Cytometry, 27:117–125, 1997. [4] H. Netten, I. T. Young, L. J. van Vliet, H. J. Tanke, H. Vroljik, and W. R. Sloos. FISH and chips: automation of fluorescent dot counting in interphase cell nuclei. Cytometry, 28:1–10, 1997. [5] I. Ravkin and V. Temov. Automated microscopy system for detection and genetic characterization of fetal nucleated red blood cells on slides. Proc. Opt. Invest. Cells In Vitro In Vivo, 3260:180–191, 1998. [6] D. J. Stephens and V. J. Allan. Light microscopy techniques for live cell imaging. Science, 300:82–86, 2003. [7] T. Lehmann, J. Brendo, V. Metzler, G. Brook, and W. Nacimlento. Computer assisted quantifica- tion of axo-somatic buttons at the cell membrane of motorneurons. IEEE Trans. Biomed. Eng., 48:706–717, 2001. [8] J. Lu, D. M. Healy, and J. B. Weaver. Contrast enhancement of medical images using multiscale edge representation. Opt. Eng., 33:2151–2161, 1994. [9] J. S. Ploem, A. M. van Driel-Kulker, L. Goyarts-Veldstra, J. J. Ploem-Zaaijer, N. P. Ver woerd, and M. van der Zwan. Image analysis combined with quantitative cytochemistry. Histochemistry, 84:549–555, 1986. [10] E. M. Slayter and H. S. Slayter. Light and Electron Microscopy. Cambridge University Press, New York, NY, 1992. [11] I. T. Young. Quantitative microscopy. IEEE Eng. Med. Biol., 15:59–66, 1996. [12] J. D. Cortese. Microscopy paraphernalia: accessories and peripherals boost performance. The Scientist, 14(24):26, 2000. [13] E. Gratton and M. J. vandeVan. Laser sources for confocal microscopy. In J. B. Pawley, editor, Handbook of Biological Confocal Microscopy. Plenum, New York, 69–97, 1995. [14] Q. Wu. Autofocusing. In Q. Wu, F. A. Merchant, and K. R. Castleman, editors, Microscope Image Processing. Academic Press, Boston, MA, 441–467, 2008. [15] E. T. Johnson andL. J. Goforth. Metaphase spre ad detection andfocus usingclosed circuit television. J. Histochem. Cytochem., 22(7):536–545, 1974. [16] B. Dew, T. King, and D. Mighdoll. An automatic microscope system for differential leucocyte counting. J. Histochem. Cytochem., 22:685–696, 1974. [17] H. Harms and H. M. Aus. Comparison of digital focus criteria for a TV microscope system. Cytometry, 5:236–243, 1984. [18] F. C. Groen, I. T. Young, and G. Ligthart. A comparison of different focus functions for use in autofocus algorithms. Cytome try, 6(2):81–91, 1985. [19] F. R. Boddeke, L. J. van Vliet, H. Netten, and I. T. Young. Autofocusing in microscopy based on the OTF and sampling. Bioimaging, 2:193–203, 1994. References 829 [20] L. Firestone, K. Cook, K. Culp, N. Talsania, and K. Preston. Comparison of autofocus methods for automated microscopy. Cytometry, 12(3):195–206, 1991. [21] D. Vollath. Automatic focusing by correlative methods. J. Microsc., 147:279–288, 1987. [22] D. Vollath. The influence of scene parameters and of noise on the behavior of automatic focusing algorithms. J. Microsc., 152(2):133–146, 1988. [23] J. F. Brenner, B. S. Dew, J. B. Horton, T. King, P. W. Neurath, and W. D. Selles. An automated microscope for cy tologic research. J. Histochem. Cytochem., 24:100–111, 1976. [24] A. Erteza. Depth of convergence of a sharpness index autofocus system. Appl. Opt., 15:877–881, 1976. [25] A. Erteza. Sharpness index and its application to focus control. Appl. Opt., 16:2273–2278, 1977. [26] R. A. Muller and A. Buffington. Real time correction of atmospherically degraded telescope images through image sharpening. J. Opt. Soc. Am., 64:1200–1210, 1974. [27] J. H. Price and D. A. Gough. Comparison of phase-contrast and fluorescence digital autofocus for scanning microscopy. Cytometry, 16(4):283–297, 1994. [28] J. M. Geusebroek, F. Cornelissen, A. W. Smeulders, and H. Geerts. Robust autofocusing in microscopy. Cytometry, 39(1):1–9, 2000. [29] A. Santos, C. Ortiz de Solorzano, J. J. Vaquero, J. M. Pena, N. Malpica, and F. del Pozo. Evaluation of autofocus functions in molecular cytogenetic analysis. J. Microsc., 188(3):264–272, 1997. [30] J. C. Russ. The Image Processing Handbook. CRC Press, Boca Raton, FL, 1994. [31] K. R. Castleman, T. P. Riopka, and Q. Wu. FISH image analysis. IEEE Eng. Med. Biol., 15(1):67–75, 1996. [32] E. R. Doughert y and J. Astola. An Introduction to Nonlinear Image Processing. SPIE, Bellingham, WA, 1994. [33] J. Serra. Image Analysis and Mathematical Morphology. Academic Press, London, 1982. [34] K. R. Castleman. Digital image color compensation with unequal integration periods. Bioimaging, 2:160–162, 1994. [35] K. R. Castleman and I. T. Young. Fundamentals of microscopy. In Q. Wu, F. A. Merchant, and K. R. Castleman, editors, Microscope Image Processing. Academic Press, Boston, MA, 11–25, 2008. [36] Y. Wang, Q. Wu, and K. R. Castleman. Image enhancement. In Q. Wu, F. A. Merchant, and K. R. Castleman, editors, Microscope Image Processing. Academic Press, Boston, MA, 59–78, 2008. [37] W. E. Higgins, W. J. T. Spyra, E. L. Ritman, Y. Kim, and F. A. Spelman. Automatic extraction of the arterial tree from 3-D angiograms. IEEE Conf. Eng. Med. Biol., 2:563–564, 1989. [38] N. Niki, Y. Kawata, H. Satoh, and T. Kumazaki. 3D imaging of blood vessels using x-ray rotational angiographic system. IEEE Med. Imaging Conf., 3:1873–1877, 1993. [39] C. Molina, G. Prause, P. Radeva, and M. Sonka. 3-D catheter path reconstruction from biplane angiograms. SPIE, 3338:504–512, 1998. [40] A. Klein,T. K. Egglin, J. S. Pollak, F. Lee, and A. Amini. Identifying vascular features with orientation specific filters and b-spline snakes. IEEE Comput. Cardiol., 113–116, 1994. [41] A. K. Klein, F. Lee, and A. A. Amini. Quantitative coronary angiography with deformable spline models. IEEE Trans. Med. Imaging, 16:468–482, 1997. [42] D. Guo and P. Richardson. Automatic vessel extraction from angiogram images. IEEE Comput. Cardiol., 25:441–444, 1998. 830 CHAPTER 27 Computer-Assisted Microscopy [43] Y. Sato, S. Nakajima, N. Shiraga, H. Atsumi, S. Yoshida,T. Koller, G. Gerig, and R. Kikinis. 3D multi- scale line filter for segmentation and visialization of cur vilinear structures in medical images. IEEE Med. Image Anal., 2:143–168, 1998. [44] K. R. Castleman. Digital Image Processing. Prentice Hall, Englewood Cliffs, NJ, 1996. [45] T. Ridler and S. Calvard. Picture thresholding using an iterative selection method. IEEE Trans. Syst. Man Cybern., 8:629–632, 1978. [46] W. Tsai. Moment-preserving thresholding. Comput. Vis. Graph. Image Process., 29:377–393, 1985. [47] N. Otsu. A threshold selection method from gray-level histograms. IEEE Trans. Syst. Man Cybern., 9:62–66, 1979. [48] J. Kapur, P. Sahoo, and A. Wong. A new method for gray-level picture thresholding using the entropy of the histogram. Comput. Vis. Graph. Image Process., 29(3):273–285, 1985. [49] Q. Wu, and K. R. Castleman. Image segmentation. In Q. Wu, F. A. Merchant, and K. R. Castleman, editors, Microscope Image Processing. Academic Press, Boston, MA, 159–194, 2008. [50] A. C. Bovik, editor. The Handbook of Image and Video Processing, Chap. 4.8, 4.9, and 4.12. Elsevier Academic Press, 2005. [51] T. McInerney and D. Terzopoulos. Deformable models in medical image analysis: a survey. IEEE Med. Image Anal., 1:91–108, 1996. [52] C. Smets,G. Verbeeck, P. Suetens, and A. Oosterlinck. Aknowledge-based system for the delineation of blood vessels on subtra ction angiograms. Pattern Recognit. Lett., 8:113–121, 1988. [53] R. Nekovei and Y. Sun. Back-propagation network and its configuration for blood vessel detection in angiograms. IEEE Trans. Neural Netw., 6:64–72, 1995. [54] L. Dorst. Discrete Straight Lines: Parameters, Primitives and Properties. Delft University Press, Delft, The Netherlands, 1986. [55] T. Y. Young, and K. Fu. Handbook of Pattern Recognition and Image Processing. Academic Press, San Diego, CA, 1986. [56] A. K. Jain. Fundamentals of Digital Image Processing. Prentice-Hall, Englewood Cliffs, NJ, 1989. [57] H. Firth, P. A. Boyd, P. Chamberlain, I. Z. Mackenzie, R. H. Lindenbaum, and S. M. Hudson. Severe limb abnormalities after chorionic villus sampling at 56 to 66 days. Lancet, 1:762–763, 1991. [58] D. Ganshirt-Ahlert, M. Burschyk, H. P. Garr itsen, L. Helmer, P. Miny, J. Horst, H. P. Schneider, and W. Holzgreve. Magnetic cell sorting and the transferrin receptor as potential means of prenatal diagnosis from maternal blood. Am. J. Obstet. Gynecol., 166:1350–1355, 1992. [59] D. W. Bianchi,G. K. Zickwolf,M. C.Yih,A. F. Flint,O. H.Geifman, M. S. Erikson,and J. M.Williams. Erythroid-specific antibodies enhance detection of fetal nucleated erythrocytes in maternal blood. Prenat. Diagn., 13:293–300, 1993. [60] S. Elias, J. Price,M. Dockter, S. Wachtel,A. Tharapel, J. L. Simpson, and K.W. Klinger. First trimester prenatal diagnosis of trisomy 21 in fetal cells from maternal blood. Lancet, 340:1033, 1992. [61] F. A. Merchant, S. J. Aggarwal, K. R. Diller, K. A. Bartels, and A. C. Bovik. Three-dimensional distribution of damaged cells in cryopreserved pancreatic islets as determined by laser scanning confocal microscopy. J. Microsc., 169:329–338, 1993. [62] K. R. Castleman and B. S.White. Dot-Count proportion estimation in FISH specimens.Bioimaging, 3:88–93, 1995. [63] F. A. Merchant and K. R. Castleman. Strategies for automated fetal cell screening. Hum. Reprod. Update, 8(6):509–521, 2002. References 831 [64] S. J. Knight and J. Flint. Perfect endings: a review of subtelomeric probes and their use in clinical diagnosis. J. Me d. Genet., 37(6):401–409, 2000. [65] X. Hu, A. M. Burghes, P. N. Ray, M. W. Thompson, E. G. Murphy, and R. G. Worton. Partial gene duplication in Duchenne and Becker muscular dystrophies. J. Med. Genet., 25:369–376, 1988. [66] K. S. Chen, P. Manian, T. Koeuth, L. Potocki, Q. Zhao, A. C. Chinault, C. C. Lee, and J. R. Lupski. Homologous recombination of a flanking repeat gene cluster is a mechanism for a commom contiguous gene deletion syndrome. Nat. Genet., 17:154–163, 1997. [67] L. Potocki, K. Chen, S. Park, D. E. Osterholm, M. A. Withers, V. Kimonis, A. M. Summers, W. S. Meschino, K. Anyane-Yeboa, C. D. Kashork, L. G. Shaffer, and J. R. Lupski. Molecular mech- anism for duplication 17p11.2 - the homologous recombination reciprocal of the Smith-Magenis microdeletion. Nat. Genet., 24:84–87, 2000. [68] W. H. Press, W. T. Flannery, S. A. Teukolsky, and B. P. Vetterling. Numerical Recipes in C. Cambridge University Press, New York, 1992. [69] M. Weinstein and K. R. Castleman. Reconstructing 3-D specimens from 2-D section images. Proc. SPIE, 26:131–138, 1971. [70] S. Mallat. A theory for multiresolution signal decomposition: the wavelength representation. IEEE Trans. Pattern Anal. Mach. Intell., 11:674–693, 1989. [71] I. Daubechies. Orthonormal bases of compactly supported wavelets. Commun. Pure and Appl. Math., 41:909–996, 1988. [72] J. Aggarwal. Multisensor Fusion for Computer Vision. Springer-Verlag, New York, NY, 1993. [...]...CHAPTER Towards Video Processing Alan C Bovik The University of Texas at Austin 28 Hopefully the reader has found the Essential Guide to Image Processing to be a valuable resource for understanding the principles of digital image processing, ranging from the very basic to the more advanced The range of readers interested in the topic is quite broad, since image processing is vital to nearly every... relate to the significant increase in data volume The extra (temporal) dimension of video implies significant increases in required storage, bandwidth, and processing resources Naturally it is of high interest to find efficient algorithms that exploit some of the special characteristics of video, such as temporal redundancy, in video processing The companion book to this one, the Essential Guide to Video... still image processing methods for adaptation to video, and also requires the development of entirely new processing philosophies That aspect is motion 833 834 CHAPTER 28 Towards Video Processing Digital videos are taken from a real world containing 3D objects in motion These objects in motion project to images that are in motion, meaning that the image intensities and/or colors are in motion at the image. .. many approaches that derive from the essential principles of digital image processing (of still images) found in this Guide Indeed, it is best to become conversant in the techniques of digital image processing before embarking on the study of digital video processing However, there is one important aspect of video processing that significantly distinguishes it from still image processing, makes necessary... current book, the companion video Guide finishes with a series of interesting and essential applications including video surveillance, video analysis of faces, medical video processing, and video-speech analysis It is our hope that the reader will embark on the second leg of their voyage of discovery into one of the most exciting and timely technological topics of our age The first leg, digital image processing,... experience of images is not limited to the still images that are considered in this Guide Indeed, much of the richness of visual information is created by scene changes recorded as time-varying visual information Devices for sensors and recording moving images have been evolving very rapidly in terms of speed, accuracy, and sensitivity, and for nearly every type of available radiation These time-varying images,... 435–436 size of, 15–17 Image denoising, 210, 215, 242 Image differencing for change detection, 63–65 Image editing software, 34 Image fidelity, 553 watermarked, 606, 634 Image filtering, linear and nonlinear, 36 Image formation model in Fourier domain, 325f in spatial domain, 325f Image frequency and DFT, 115–121 granularity of, 115–118, 116f–118f orientation, 118–121, 119f–121f Image histogram, 44–47 cumulative... monitor, 184f Photoelectric effect, 783 Photographic grain noise, 159–160 Photographic images, multiscale denoising of, 241–260 Photometrics SenSysTM , 800 Photomultiplier tubes (PMTs), 744 Physical functions, analog images as, 179–180 Physiological biometrics, 677, 678t Piecewise-linear Markov maps, 619 Pixels, 8 polyphase interpolation of, 283, 284f quantized, 9, 11f POCS, see Projections onto convex... approach, 373, 378 Hierarchical Bayesian image restoration, 372–374 High-frequency sound waves, 2 Highpass filter, 229 for image sharpening, 286 Hilbert transform pairs, 563 Histogram approaches bimodal, 71, 72, 73f effects of multiplicative image scaling on, 51f, 52f multimodal, 74f Histogram equalization, 56–59, 58f, 59f digital, 57 Histogram flattening, 56 Histogram shaping, 59–60 Hit-miss filter, 309... explains the significant problems encountered in video processing, beginning with the essentials of video sampling, through motion estimation and tracking, common processing steps such as enhancement and interpolation, the extremely important topic of video compression, and on to more advanced topics such as video quality assessment, video networking, video security, and wireless video Like the current . coefficients. If the basis functions match the interesting components of the image, then the fused image will contain the interesting components collected up from all of the input images. The images can. 1993. CHAPTER 28 Towards Video Processing Alan C. Bovik The University of Texas at Austin Hopefully the reader has found the Essential Guide to Image Processing to be a valuable resource for understanding the. image, then their coefficients will be large and the other coefficients will be negligible, yielding a very compact representation. The coefficients that correspond to the desired components of the image

Ngày đăng: 01/07/2014, 10:44

TỪ KHÓA LIÊN QUAN