1. Trang chủ
  2. » Ngoại Ngữ

Process Engineering for Pollution Control and Waste Minimization_8 pot

26 401 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 26
Dung lượng 898,73 KB

Nội dung

cells in a rectangular reaction tank. A high-voltage electrode coated with poly- ethylene is wound on the perforated baffle plate separating the extraction and stripping cell. When a high-voltage electrostatic field is applied to the reaction tank, the aqueous drops in the organic continuous phase disintegrate into numer- ous smaller droplets under the action of the electrostatic field. This provides a great deal of surface area for separation. The extractant dissolved in the continu- ous organic phase acts as a shuttle to transport metal ions from the extraction cell to the stripping cell. A summary of opportunities for membrane technologies in the treatment of mining and mineral process streams was presented by Awadalla and Kumar (4). This study indicated a variety of applications including acid mine drainage (AMD), treatment of flotation water, copper smelting and refining wastewater, mill wastewater, removal of ammonium and nitrate ions, membranes in the aluminum industry, treatment of groundwater, treatment of uranium wastewater, treatment of dilute gold cyanide solutions, recovery of zinc from pond water, rare earth (RE) concentration, and separation of selenium from barren solution. AMD contains pollutants such as iron, manganese, calcium, magnesium, and sulfate ions. Although lime neutralization is considered the “best available technology economically achievable,” it is no longer considered environmentally acceptable because of the low-level contamination of heavy metals which cannot be removed. Alternatively, almost complete removal of dissolved solids can be achieved by the use of ion exchange, distillation, and reverse osmosis (RO) to produce high-quality water which can be used by municipalities or industry. The use of RO is best implemented as a supplement to neutralization processes. The RO concentrate stream is neutralized and clarified prior to discharge or recycled. Coupled RO/ion exchange can be used when high concentration of calcium sulfate and/or iron fouling is a problem. For the case of water reuse in which completely demineralized water is not essential, a charged ultrafiltration process using negatively charged noncellulosic membranes was utilized. For the case of AMD for coal conversion processes, high-ultrafiltration recovery with high removal of calcium sulfate and iron and good flux are required. Recovery of up to 97% is achievable by introducing an interstage settling step. Commer- cially available charged ultrafiltration membranes by PSAL (millipore type of noncellulosic skin on cellulosic backing) were used in this study. Cost for treatment using UF with interstage settling are $1.33/1000 gal of AMD, including membrane replacement cost, pumping cost, and lime cost. In order to avoid problems with recycling wastewater from flotation mills which contain the breakdown products of collector-frother reagents, the water must be purified before recycling to the mining operation. The traditional method for treatment of flotation water involves lime precipitation, ozonation, adsorption on activated carbon, and biological treatment (4). Biological treatment requires excessive holdup and is dependent on the climate, the presence of toxic heavy Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. metals, and sensitive control of the microorganisms. Reverse osmosis has been used for the recovery of flotation reagents. Commercial RO membranes have been used to remove 95% of organic carbon, calcium, and magnesium from the flotation feed stream. Scrubber blowdown from a primary copper smelting plant and acid process- ing water from a selenium-tellurium plant have been treated using negatively charged noncellulosic ultrafiltration membranes (4) . Removal of over 85% of As and Se from the acid processing water was made possible when the pH was adjusted to 10 and the solids were settled prior to ultrafiltration. Scrubber blowdown was effectively treated without pH adjustment to a pH of 4.5. Arsenic- containing wastewater was also pretreated with UF and polished using RO. This method produced a permeate stream containing less than 50 ppb arsenic. Alkaline solutions of NaCN are used to leach gold-containing ores, produc- ing dilute gold cyanide solutions (4). The two conventional methods of recovering gold from these solutions include the Merill-Crowc process of cementation using zinc powder and adsorption using activated carbon. Concentrated gold solutions are formed by elution. Reverse osmosis has been investigated as a means to concentrate the dilute gold solutions. In the case of metal finishing operations using gold and cyanide solutions, FilmTec FT-30 membranes have been used to provide rejections in the range of 91–99% for free and combined cyanides (with copper and zinc). Membrane performance was strongly pH dependent. Reverse osmosis has also been used for silver and copper cyanide concentration (Os- monics, Inc). This study utilized a nitrogen-containing aromatic condensation polymer. Experiments indicated that the feed could be concentrated three times with 70% removal of permeate, resulting in low gold content in the permeate. Nanofiltration (NF) and RO have been used for removal of ammonium and nitrate ions from synthetic and actual mine effluents (5). In mine and mill water, ammonium and nitrate ions are generated from the degradation of cyanide from gold mill effluents and ammonium nitrate-fuel oil (ANFO) blasting agents in mines. Nitrogen-containing reagents are also used in ore processing and extrac- tive metallurgy. The results of experiments using NF and RO membranes were reported for testing and actual mill effluent. The results of the testing were that good removal of ammonium (>99%) and nitrate ions (>97%) were achieved using RO, while NF was less effective. Lower effectiveness of the NF membrane was believed to be caused by ammonium being present in the sulfate form and not the larger ammonium iron sulfate complex which does not form because there is no iron in the mining effluent. No scaling or fouling problems were observed in these studies. Cross-flow membrane technolgies have also been applied to mineral sus- pensions (6). In this study, using microporous filtration (0.1-µm membranes) suspensions of CaCO 3 were investigated using an intermittent cleaning approach in order to increase the permeate flux. Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. A thorough review of membrane technology for applications to industrial wastewater treatment has been made by Caetano (7). In this review, E. Drioli provides a broad overview in the areas of desalination, gas separation, pervapora- tion, membrane bioreactors, enzyme membrane reactors, and hybrid systems based on pervaporation and distillation. In the more general area of environmental applications, significant work has been done on the treatment of streams containing metals. There has been a great deal of interest in the use of ion-exchange membranes in this area. Sengupta (8) has investigated electromembrane partitioning as a means for heavy metal decontamination. This is a unique and rather interesting new approach for the in-situ removal of metals from contaminated soils. A low-level direct current (DC), less than 1 V/cm, is applied to the soil while a composite ion-exchange membrane is wrapped around the cathode. Upon imposition of the DC potential, the cations move toward the cathode, where they are captured by the composite membrane. By the design of the ion-exchange membrane, the nonselective ions should pass freely through the membrane. The membrane utilized for this work is a thin sheet prepared by grinding a cross- linked polymer ion exchanger and suspending the ion exchanger in a PTFE porous matrix. These membranes are 90% ion exchanger, 10% PTFE, and are microporous with >40% voids with a pore size distribution below 0.5 µm. One potential problem with this process is that periodically these membranes must be removed and chemically regenerated with strong (3–5%) mineral acid solution. Electrodialytic decontamination of soil polluted with heavy metals has been investigated using ion-exchange membranes by Hansen et al. (9). The process for removal of metal ions from soils using electric current and passive membranes is known as electrokinetic soil remediation. This method involves the use of passive membranes to separate the polluted soil from the electrodes. There are several shortcomings to this approach, including addition of acid counterions into the soil, return of heavy metals back into the soil, and heavy-metal precipitation at the H + and OH – front. By introduction of ion-exchange membranes into the electro- kinetic soil remediation process, an electrodialytic soil remediation process results. The ion-exchange membranes are oriented in certain directions. This orientation, with pairs of anion- and cation-exchange membranes placed on both sides of the polluted soil, eliminates all three of the problems mentioned above. This configuration also provides two compartments containing liquid solutions and the heavy metals, which can be withdrawn as needed. In this situation, heavy-metal ions pass through the cation-exchange membrane in the direction of the cathode and are prevented from passing through the anion-exchange mem- brane and never reach the cathode. They end up in the compartment between the two ion-exchange membranes. Li et al. (10) have investigated the use of a cation-selective membrane for removal of heavy metals from soils. An improvement in the traditional elec- Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. troremediation approach is described. In this work a cation membrane is placed around the cathode to prevent hydroxyl species moving toward the anode. This prevents precipitation of metals in the soil, and the metals precipitate in the column of water around the cathode. Membranes are also used for removal of metals for industrial applications (11). Bulk liquid membranes are used for facilitated transport of silver using a rotating film pertraction device. In this process two aqueous solutions are separated by an organic liquid. The membrane liquid is in contact with the donor and acceptor liquids adhering to the surfaces of the rotating disks. Transport of the solvent involves extraction from one solution and stripping in the other. This paper describes the recovery of silver from nitrate solutions using the rotating film pertraction method using tri-isobutylphosphine sulfide (TIBPS) in n-octane as the liquid membrane. Aqueous silver nitrate was the donor phase and the acceptor phase was aqueous ammonia. The results of the study indicated that because of low rates of transport of other metals, including copper, zinc, and nickel, rotating film pertraction can be used effectively to separate silver from solution. Yang et al. (2) describe a unique metal extraction method using two sets of hydrophobic microporous hollow fiber membranes for separation of metals in solution. One set of hollow fibers carries an acidic organic extractant (LIX 84, anti-2-hydroxy-5-nonylacetophenone oxime) in a diluent. The other set of hollow fibers carries a basic organic extractant (TOA, tri-n-octylamine). The aqueous, metal-containing stream is carried on the shell side of the membrane system. Cations, including copper, zinc, and nickel, are transported into the acidic extractant. Anions, including chromium(VI), mercury, and cadmium, are ex- tracted into the basic stream. Palladium has also been separated from silver in a nitric acid solution using liquid surfactant membranes (12). The organic carrier used in these studies is LIX 860, which is a β-hydroxyoxime. The liquid surfactant membrane is Span 80, a commercially available surfactant, and the solvent is n-heptane. The aqueous donor phase contains silver and palladium and is acidified using nitric acid. The receiving phase contains thiourea and is tested in hydrochloric, perchloric, nitric, and sulfuric acids. Under optimal conditions, palladium was separated from silver recovered in entirety. Another liquid membrane, investigated by Fu et al. (13), is trioctylamine (TOA) as a mobile carrier in kerosene. Precious metals, including gold, palladium, platinum, iridium, and ruthenium in hydrochloric acid, were ex- tracted using this membrane system. The metals were extracted into perchlorate and nitric acid solutions. An inert PTFE polymer 80 µm thick, 74% porous, and 0.45 µm in average pore diameter was used as a support for the liquid membrane. Low-pressure reverse osmosis (RO) was used by Ujang and Anderson (14) for separation of mono- and divalent ions. Sulfonated polysulfone membranes are Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. used as a low-pressure reverse osmosis process for separation of mono- and divalent zinc ions. It was observed that the higher the operating pressure, the greater was the permeate flux for both species. At lower operating pressure, higher permeate fluxes were observed using divalent ions. Metal removal of divalent ions was greater for divalent ions than for monovalent ions for all concentrations. 2 ADSORPTION MATERIALS AND PROCESSES Recovery of gold from cyanide has been evaluated using many different ad- sorbent materials. Petersen and Van Deventer (15) investigated the competitive role of gold and organics on adsorption by a variety of adsorbents, including activated carbon, ion-exchange resin, ion-exchange fibers, and membranes. A variety of adsorbents were investigated, including coconut shell activated carbon, macroporous ion-exchange resin, ion-exchange membrane, and ion-exchange fibers (polypropylene-based strong-base and weak-base fibers). Adsorbents were evaluated after being exposed to the organic compound, sodium ethyl xanthate, for 6 h. The absorbents were challenged with a variety of organic compounds, including ethanol, sodium ethyl xanthate, potassium amyl xanthate, and phenol. The two mechanisms investigated to explain the reduced adsorption of gold in the presence of the organics were (a) blockage of the carbon pores by the organic, and (b) competition between gold cyanide and organics for the active sites on the carbon surface. The results of the study indicated that both the rate of adsorption and the equilibrium loading were affected by the organic on the adsorption of gold cyanide onto activated carbon. The resin particles were only effected by the rate of adsorption, while the membranes and fibers experienced both kinetic and equilibrium changes. The results of this study indicated that the long-chain organics (xanthates) have a higher degree of inhibition of mass transfer of gold cyanide compared to the low-molecular-weight substance (ethanol). The aromatic substances did not affect the performance of the fibers or membrane. This is because the small pore diameters did not permit the large aromatics to penetrate. The results indicated that the second mechanism, a competitive effect between gold cyanide and the organic compounds, was responsible for the results observed for the gold-equilibrated absorbents. Klein et al. (16) have investigated polymeric resins as adsorbents for industrial applications. The motivation for investigation of polymeric resins versus activated carbon is their ease of regeneration. Activated carbon systems are typically regenerated using steam or thermal methods, while polymeric resins can be regenerated using simple solvents such as aliphatic alcohols. The resins used were methylene-bridged styrene divinylbenzene-based co-polymer (Dow Chemical, Midland, MI). Some of the characteristics of these polymeric resins which may be controlled are hydrophobicity, pore size, and surface area. These Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. resins were challenged with benzoic acid and chlorobenzene, and adsorption isotherms and bed regeneration curves were generated. The results of this study indicated that with only few bed volumes (15–25), using methanol as regenerant, 90–95% of the adsorbed solute could be recovered. The polymeric resins main- tained good adsorptive capacity after repeated cycling. 3 ION-EXCHANGE MATERIALS AND PROCESSES Applications of ion exchange to leaching solutions of an Algerian gold ore have been investigated by Akretche et al. (17). In the cyanide medium, the gold and other metals such as silver, copper, and iron attach to the anion-exchange resin. These metals are later eluted with acid thiourea to yield a concentrated solution which is treated by cementation or an electrolytic method. This work describes the use of electrodialysis of copper(I), which is normally not feasible due to the presence of formamidine disulfide. This is accomplished when the solutions are obtained by elution of cuprocyanides by thiourea. 4 CONCLUSIONS There have been great strides in the development of new technologies for pollution control in the mining industry during the past five years, many in the development of new materials and processes. Many of these developments are in the areas of membranes, adsorbents, and ion exchange. In the area of membranes, a great of work has been done using liquid membranes. These are generally supported synthetic membrane systems with a variety of liquids to facilitate transport. Electroremediation and electrodialytic membrane approaches have also seen a great deal of attention. Activated carbon-based and other organic ab- sorbents have been used for treatment of mining wastes. Polymeric resins have also been used as adsorbents for industrial applications. Anionic ion-exchange resins have also been used for treatment of leaching solutions. REFERENCES 1. W. L. McCabe, J. C. Smith, and P. Harriott, Unit Operations of Chemical Engineer- ing, 5th Edition, New York: McGraw-Hill, 1993. 2. Z. F. Yang, A. K. Guha, and K. Sirkar, Ind. Eng. Chem. Res., vol. 35, pp. 1383–1394, 1996. 3. F. Valenzuela, C. Basualto, C. Tapia, and J. Sapag, J. Membrane Sci., vol. 155, pp. 163–168, 1999. 4. F. T. Awadalla and A. Kumar, Separation Sci. Technol., vol. 29, no. 10, pp. 1231– 1249, 1994. 5. F. T. Awadalla, C. Striez, and K. Lamb, Separation Sci. Technol., vol. 29, no. 4, pp. 483–495, 1994. Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. 6. D. Si-Hassen, A. Ould-Dris, M. Y. Jaffrin, and Y. K. Benkahla, J. Membrane Sci.,vol. 118, pp. 185–188, 1996. 7. A. Caetano (ed.), Membrane Technology: Applications to Industrial Wastewater Treatment. Dordrecht, The Netherlands: Kluwer, 1995. 8. S. Sengupta and A. K. Sengupta, Hazardous and Industrial Wastes—Proceedings of the Mid-Atlantic Industrial Waste Conference Proceedings of the 1997 29th Mid- Atlantic Industrial and Hazardous Waste Conference, July 13–16, 1997, Blacksburg, VA, Lancaster, PA: Technomic Publishing Co. Inc., pp. 174–182. 9. H. K. Hansen, L. M. Ottosen, S. Laursen, and A. Villumsen, Separation Sci. Technol., vol. 32, no. 15, pp. 2425–2444, 1997. 10. Z. Li, J. Yu, and I. Neretnieks, Environ. Sci. Technol., vol. 32, pp. 394–397, 1998. 11. L. Boyadzhiev and K. Dimitrov, J. Membrane Sci., vol. 68, p. 137–143, 1994. 12. T. Kakoi, M. Goto, and F. Nakashioo, Separation Sci. Technol., vol. 32, no. 8, pp. 1415–1432, 1997. 13. J. Fu, S. Nakamura, and K. Akiba. Separation Sci. Technol., vol. 32, no. 8, pp. 1433– 1445, 1997. 14. Z. Ujang and G. K. Anderson, Water Sci. Technol., vol. 38, no. 4–5, pp. 521–528, 1998. 15. F. W. Petersen and J. S. J. Van Deventer, Separation Sci. Technol., vol. 32, no. 13, pp. 2087–2103, 1997. 16. J. Klein, G. M. Gusler, and Y. Cohen, Removal of Organics from Aqueous Systems: Dynamic Sorption/Regeneration Studies with Polymeric Resins. In Novel Absorbents and Their Environmental Applications, Y. Cohen and R. W. Peters (eds.), AIChE Symp. Ser., vol. 91, pp. 72–78. 17. D. E. Akretche, A. Gherrou, and H. Kerdjoudj, Hydrometallurgy, vol. 46, pp. 287– 301, 1997. Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. 12 Monitoring In-Situ Electrochemical Sensors Joseph Wang New Mexico State University, Las Cruces, New Mexico 1 INTRODUCTION Electroanalytical methods are concerned with the interplay between electricity and chemistry, namely, the measurements of electrical quantities such as current or potential, and their relationship to chemical parameters. Electroanalytical chemistry can play a major role in pollution control and prevention. In particular, electrochemical sensors and detectors are very attractive for on-site and in-situ monitoring of priority pollutants. Such devices are highly sensitive, selective toward electroactive species, fast, accurate, compact, portable, and inexpensive. Several electrochemical devices, such as oxygen or pH electrodes, have been widely used for years for environmental analysis. Recent advances in electro- chemical sensor technology have expanded the scope of electrochemical devices toward a wide range of organic and inorganic contaminants. The present chapter reviews recent efforts at the author’s laboratory, aimed at in-situ monitoring of priority pollutants. Continuous monitoring, effected in the natural environment, offers a rapid return of the chemical information (with a proper alarm in case of a sudden discharge), avoids costs and errors associated with the collection of discrete samples, while maintaining the sample integrity. The use of remote sensors thus has significant technical and cost benefits over Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. traditional sampling and analysis. Our latest developments of remote electro- chemical probes will be covered in the following sections. 2 REMOTELY DEPLOYED ELECTROCHEMICAL SENSORS Remotely deployable submersible sensors capable of monitoring contaminants in both time and location are advantageous in a variety of applications. These range from shipboard marine surveys, downhole monitoring of groundwater contami- nation, to real-time analysis of industrial streams. The development of sub- mersible electrochemical probes requires proper attention to various challenges, including the effect of sample pH, ionic strength, dissolved oxygen, or natural convection, specificity and sensitivity, surface fouling, in-situ calibration, and miniaturization. By addressing these and other obstacles, we were able to develop remote sensors for a wide range of inorganic and organic contaminants. 2.1 Remote Monitoring of Metal Contaminants Metal pollution has received enormous attention due to its detrimental impact on the environment. The need for continuous monitoring of trace metals in a variety of matrices has led to the development of submersible sensors based on electro- chemical stripping analysis (1,2). Stripping analysis has been established as a powerful technique for determining toxic metals in environmental samples (3,4). The remarkable sensitivity of stripping analysis is attributed to its unique “built- in” preconcentration step, during which the target metals are electroplated onto the surface. Both electrolytic and nonelectrolytic (adsorptive) accumulation schemes have thus been employed to achieve sub-parts-per-billion detection limits. The analytical current signal (i), obtained during the subsequent stripping (potential scanning) step is proportional to the metal concentration (C) and accumulation time (t acc ): i = KC t acc (1) Remote metal monitoring has been realized by eliminating the needs for mercury surfaces, oxygen removal, forced convection, or supporting electrolyte (which previously prevented the direct immersion of stripping electrodes into sample streams). This was accomplished through the development of nonmercury electrodes, judicious coupling of potentiometric stripping operation, and the use of advanced ultramicroelectrode technology (1). Compatibility with field opera- tions was achieved by connecting the three-electrode housing [including a gold fiber working electrode, in the polyvinyl chloride (PVC) tube], via environmen- tally sealed three-pin connectors, to a 25-m-long shielded cable. Convenient and simultaneous quantitation of several trace metal levels (e.g., Pb, Cu, Ag, Hg) has Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. thus been realized in connection to measurement frequencies of 20–30/h (based on deposition periods of 1–2 min). The in-situ monitoring capability of the remote metal sensor was demon- strated in studies of the distribution of labile copper in San Diego Bay (CA) (5). For this purpose, the probe was floating on the side of a small U.S. Navy vessel. The resulting map of copper distribution reflected the metal discharge and circulation pattern in the bay. We are currently collaborating with Prof. Daniele’s group in using the remote probes for assessing the distribution of metal contam- inants in the canals and lagoon of Venice, Italy (6). The extension of remote stripping electrodes to additional metals that cannot be electroplated relies on the adaptation of adsorptive stripping protocol for a submersible operation (7). Such procedures rely on the formation and adsorptive accumulation of complexes of the target metals. Accordingly, remote adsorptive stripping sensors require a new probe design based on an internal solution chemistry. Such a renewable-reagent adsorptive stripping sensor relies on the continuous delivery of the ligand, its complexation reaction with the metal “collected” in a semipermeable microdialysis sampling tube, and transport of the complex to the working electrode compartment. Such dialysis sampling also offers extension of the linear range and protection against surface fouling (due to its dilution and filtration actions). The new flow-probe format was employed for monitoring trace metals such as nickel, uranium, or chromium. As desired for effective in-situ monitoring, such adsorptive stripping probes have the capability to detect rapidly fluctuations in the analyte concentration continuously. Such ability is indicated from Figure 1, which displays the response of a chromium probe (8) upon switching from the 5- to 25 µg/l chromium solutions. Such behavior is attributed to the reversibility of the accumulation/stripping cycle, with the stripping and subsequent 10-s “clean- ing” steps completely removing the accumulated complex. In addition, the FIGURE 1 Response of the remote chromium(VI) probe to alternate expo- sures to (a) “low” (5 µg/l) and (b) “high” (25 µg/l) chromium(VI) levels. Accumulation for 30 s at –0.9 V; square-wave voltammetric stripping scan. Copyright 2002 by Marcel Dekker, Inc. All Rights Reserved. [...]... waste types defined at level zero and develop process flow diagrams for each waste type A process flow diagram is an overview of the process that generates the waste Process flow diagrams provide a summary of the processes and activities that result in the generation of waste These diagrams are used to decompose each waste type into specific waste streams For example, a waste type may be sanitary waste, ... Waste Type 2 Stream 1 Mission Level Map Element … Type N Waste Waste Waste Stream Defined For each Waste Type Waste Type 2 Stream 3 Waste Type 2 Stream 2 Waste Type 2 Stream 4 Waste Type 2 Stream 5 Process Flow Process flow defined for each Level Two Waste stream Map Element Possible Sol'tns 1 For each process flow define waste minimization or pollution prevention actions defined Level Three Map Element... sanitary waste, and waste streams within that type may be food waste, paper, and glass At level two, process diagrams are developed for each waste steam within a waste type These diagrams depict the process flow at a greater level of detail In addition to these waste stream process diagrams, new or modified procedures, processes, or technologies are identified which may reduce or eliminate the waste stream... carefully and completely identify the constituents of the waste and to quantify the volumes, since that information will form the foundation for the succeeding process flow diagrams In this case, we will examine the dumpster waste in greater detail There are a number of waste streams to be considered As a normal part of the roadmapping process, it is important to prioritize these waste streams for action... materials and energy to the system, identifying the operations that use the materials and energy, and identifying system outflows, including all the products of the operations including wastes and pollutants The wastes are accrued into a number of broad waste types This is a critical step since it will form, in many cases, the foundation for all subsequent analysis The waste types must be comprehensive and. .. describe the processes that produce each waste stream An adjunct to the process flow map element is the definition of procedure, process, or technology options for treating the object The likely impact of each option is then described Technical risk, schedule risk, cost, and health and safety impacts are assessed For high-priority or complex waste streams the options identified in the process flow... generally more useful for devising pollution prevention and waste minimization strategies and choosing among technological alternatives As an example, we will construct a map based on waste type and follow a specific waste type—sanitary waste through the succeeding map elements Janet Watson constructed the complete ESO sanitary roadmap, from which this was abstracted 3.1.2 Level One or Waste Stream Definition... Construct waste type process flow diagram Define waste streams Define issues and constraints Prioritize waste streams Since we have chosen to follow the development of roadmap elements through the sanitary waste type, we first construct a sanitary waste process flow diagram This diagram is constructed using the same principles that are used in all process flow diagrams: the inflows of materials and energy... eliminating waste generation and pollutant release by the year 2010 The purpose of the roadmap was to identify: Areas in which waste minimization and pollution prevention would have the greatest impact Options for preventing pollution or minimizing waste in those areas Costs, technical risk, time, and return on investment associated with implementing those options The most cost-effective strategies for reaching... examine a subset of the paper waste stream—mail—in detail 3.1.3 Level Two or Waste Stream Process Definition Construct waste stream process flow diagram Identify intervention points Identify prevention options The process flow diagram for the “mail” waste stream is constructed like the previous process flow diagrams However, at this level the operations are diagramed explicitly and in some detail rather . zero and develop process flow diagrams for each waste type. A process flow diagram is an overview of the process that generates the waste. Process flow diagrams provide a summary of the processes. and activities that result in the generation of waste. These diagrams are used to decompose each waste type into specific waste streams. For example, a waste type may be sanitary waste, and waste. Mulchandani, P. Mulchandani, and W. Chen, Electroanalysis, vol. 11, pp. 86 6 86 9, 1999. 14. J. Wang, G. Cepria, and Q. Chen, Electroanalysis, vol. 8, pp. 124–127, 1996. 15. J. Wang, Q. Chen, and

Ngày đăng: 20/06/2014, 03:20

TỪ KHÓA LIÊN QUAN